MAURY USCG vessel records
← All vessels

CAPT DAVID I LYON

Built
Not recorded
Last inspected
15 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 July 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9123037
WDH6815
494514
Flag
UNITED STATES
Maury page id
psix-494514

Documentation record

Registered dimensions (L × B × D)565.5 ft × 83.0 ft × 44.3 ft
Registered tonnagegross 16,856 / net 8,672
ITC dimensions (L × B × D)565.5 ft × 83.0 ft × 44.3 ft
ITC tonnagegross 16,856 / net 8,672
BuilderSTOCZNIA SZCZECINSKA NOWA SP, POLAND
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Endorsements, as the file codes themreg
DocumentationValid · issued 3 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16856 - Convention (Subpart B), Gross Ton
8672 - Convention (Subpart B), Net Ton
22878 - Dead Weight, Ton
30835 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 49 inspections, each with its date, unit and type; 77 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 49

15 July 2026 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8438549
14 July 2026 Explosive Handling Operation-Military
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8439354
26 May 2026 MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8355165
26 May 2026 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8380593
16 June 2025 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8160555
11 June 2025 ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8156680
9 June 2025 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8151779
12 May 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8165549
28 October 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7991073
29 August 2024 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7992303
25 June 2024 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7942536
16 May 2024 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7909267
30 April 2024 Re-Inspection · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 7887873
26 February 2024 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Activities Europe · Activity 7874253
8 January 2024 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7844618
8 January 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7846960
15 November 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7825030
28 June 2023 MTSA/ISPS Verification · Administrative Inspection · ISM Oversight · ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7725315
2 May 2023 Examination of Repairs · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7679249
24 April 2023 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7676552
26 March 2023 Explosive Handling Operation-Military
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7655739
24 March 2023 Deficiency Check · ACP Additional Oversight – Risk Assessment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7657727
23 March 2023 Explosive Handling Operation-Military
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7655725
21 March 2023 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7654687
21 October 2022 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7584611
13 June 2022 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7490887
5 June 2022 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection · Annual Survey · ACP Additional Oversight – Risk Assessment
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7469342
5 January 2022 Damage Survey · Underwater Inspection in lieu of Drydock
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7376285
16 September 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7340092
13 September 2021 Explosive Handling Operation-Military
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7311500
13 September 2021 Explosive Handling Operation-Military
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7311549
9 September 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7308247
7 September 2021 ISM Oversight · Administrative Inspection · Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7306808
28 July 2021 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7270183
17 June 2021 Liferaft Servicing
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7227736
19 October 2020 Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7073009
8 July 2020 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7000374
8 June 2020 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6970727
17 June 2019 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6712633
15 April 2019 ACP COI Oversight · MTSA/ISPS Verification · Re-Inspection · ACP Drydock Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6663030
10 April 2019 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6658671
21 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6545487
16 May 2018 Annual Inspection · MTSA/ISPS Verification · Deficiency Check · ACP Annual Oversight · Ballast Water Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6415646
6 July 2017 Annual Inspection · Administrative Inspection · ACP Handover Survey · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6215707
13 June 2017 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6206132
21 October 2016 Underwater Inspection in lieu of Drydock
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6026807
23 September 2016 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6007344
23 August 2016 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5980487
1 June 2016 MARPOL Annex V Examination · Deficiency Check · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5893451

Deficiency record · 77

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 May 2026 Resolved
SATISAFCTORY MEANS (IN THE FORM OF GUARD RAILS, LIFELINES)SHALL BE PROVIDED FOR THE PREOTECTION OF THE CREW IN GETTING TO AND FROM THEIR QUARTERS, THE MACHINERY SPACE AND ALL OTHER PARTS USED IN THE NECESSARY WORK OF THE SHIP. MI FOUND MULTIPLE HAND RAILS ON FORWARD PORT SIDE CARGO DECK WASTED, SHEERED, AND BROKEN. REPAIR TO SATISFACTION OF CLASS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2026
Resolved 3 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2025 Resolved
A life jacket complying with the requirements of 2.2.1 of the code shall be provided for every person on board the ship. Numerous lifejackets do not meet the requirements of the code as they are not properly marked with a SOLAS approval. (SOLAS 2024 cons. III/2.1)
Action required: 702 - Prior to embarking on international voyage
Due 25 June 2025
Resolved 24 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 June 2025 Resolved
The machinery, associated piping, and fittings shall be of design and construction adequate for the service for which it is intended. The #3 generator has a moderate fuel leak of unknown origin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 24 June 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 25 June 2024 Resolved
Whenever a vessel is deprived of the service of a member of its complement, and the master or person in charge is unable to find appropriate credentialed personnel to man the vessel. A report of sailing short must be filed with the OCMI having cognizance for inspection in the area in which the vessel is operating, or the OCMI within whose jurisdiction the voyage is completed. Vessel's master made a sailing short notification for the position of an Oiler from Saipan to Guam.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 July 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2024 Resolved
Fixed fire-extinguishing systems shall be installed having due regard to the fire growth potential of the protected spaces; and fire-extinguishing appliances shall be readily available. Upon testing of the hypermist zone above the #2 Gen the nozzles above the lube oil purifiers and #3 gen discharged. Repair to as designed condition.
Action required: 10 - Deficiency Rectified
Due 30 April 2024
Resolved 30 April 2024
Resolution: Replaced damaged orings at solenoids, tested all 8 zones satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2024 Resolved
Fixed fire-extinguishing systems shall be installed having due regard to the fire growth potential of the protected spaces; and fire-extinguishing appliances shall be readily available. Upon inspection of the CO2 room, the main maintenance stop valve for the CO2 system was found closed and locked, the chief engineer was the only one with the key.
Action required: 10 - Deficiency Rectified
Due 30 April 2024
Resolved 30 April 2024
Resolution: Chief engineer unlocked and opened the valve.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2024 Resolved
Fixed fire-extinguishing systems shall be installed having due regard to the fire growth potential of the protected spaces; and fire-extinguishing appliances shall be readily available. The hypermist nozzle above the FWD lube oil purifier was not discharging a mist, instead a trickle. Repair to original design operation.
Action required: 10 - Deficiency Rectified
Due 30 April 2024
Resolved 30 April 2024
Resolution: Engineers removed all 42 nozzles, cleaned and flushed the piping system, tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 April 2024 Resolved
The safety of passengers, crew and ship from electrical hazards will be ensured. An outlet on the main deck with an extension providing power to a storage container was found broken exposing wires and not intrinsically safe.
Action required: 10 - Deficiency Rectified
Due 30 April 2024
Resolved 30 April 2024
Resolution: Outlet was replaced new.
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance Dangerous Goods
Issued 8 January 2024 Resolved
THE ADMINISTRATION SHALL PROVIDE THE SHIP WITH AN APPROPRIATE DOCUMENT AS EVIDENCE OF COMPLIANCE OF CONSTRUCTION AND EQUIPMENT WITH THE REQUIREMENTS OF THIS REGULATION. VESSEL FOUND NOT IN COMPLIANCE WITH DOCUMENT OF COMPLIANCE FOR DANGEROUS GOODS. CLASS 1 EXPLOSIVES FOUND IN NOT PERMITTED HOLDS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2024
Resolution: Received a copy of the revised DOC dated 16JAN2024, reference uploaded document.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 8 January 2024 Resolved
EACH HAZMAT EMPLOYEE SHALL BE PROVIDED GENERAL AWARENESS/FAMILIARIZATION TRAINING AS REQUIRED BY 46 CFR PART 172. THE [name withheld] OFFICER WERE DETERMINED NOT IN COMPLIANCE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2024
Resolution: Received copies of crewmember HAZMAT training completion certificates.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 8 January 2024 Resolved
THE COMPANY SHOULD ENSURE THAT ALL PERSONNEL INVOLVED IN THE COMPANY'S SAFETY MANAGEMENT SYSTEM HAVE AN ADEQUATE UNDERSTANDING OF RELEVANT RULES, REGULATIONS, CODES AND GUIDELINES. FOUND OBJECTIVE EVIDENCE THE VESSEL WAS NOT FOLLOWING SMS AFTER FINDING 1.9 MILLION NET TONS OF EXPLOSIVES BEING HELD IN A NON AUTHORIZED LOCATION FOR MULTIPLE YEARS AND PERSONNEL INVOLVED IN THE HANDLING OF DANGERGOUS GOODS WITHOUT REQUIRED TRAINING. THE OPERATOR IS REQUIRED TO CONDUCT AN EXTERNAL SMS AUDIT TO ENSURE VESSEL AND COMPANY ARE IN COMPLIANCE IN ACCORDANCE WITH APPLICABLE REGULATIONS AND CODE. 74 SOLAS(20) CH IX REG 3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024
Resolved 19 January 2024
Resolution: Company conducted a Root Cause Analysis providing objective evidence which outlined the circumstance, unrelated to the company, which led to an administrative on the Document of Compliance when issued. Requirement for external audit is rescinded.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 January 2024 Resolved
NO MORE THAN 19 LITERS (FIVE GALLONS) OF FLAMMABLE LIQUIDS MAY BE STOWED IN ANY MACHINERY SPACE. THE FLAMMABLE LIQUIDS MUST BE IN CONTAINERS OF 3.8 LITER (ONE GALLON) OR LESS. SEVERAL FLAMMABLE LIQUID CONTAINERS WERE FOUND ADJACENT TO RACK NEAR THE MAIN ENGINE.
Action required: 10 - Deficiency Rectified
Due 8 January 2024
Resolved 8 January 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 August 2023 Resolved
Temp sensor for #3 cargo hold ACDH with faults from damage - needs technical support for correction
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2023
Resolution: Temp sensor corrected by CHENG
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 August 2023 Resolved
Free-fall lifeboat windows faded & not visible, requires correction or replacement for operator visibility.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 August 2023 Resolved
The construction of all doors and door frames in ``A'' class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. fire doors (x3) noted no latch or missing keyholes in fire-rated boundaries - requires correction.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 August 2023 Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. CO2 cylinders were found with cracked flexible hoses (protective outer sleeve, inner metal sheath intact) - located outside ECR - recommend new hoses be placed on order for install within the next year
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 2 August 2023 Resolved
Fire control plan - In all ships general arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the various fire sections enclosed by ``A'' class divisions, the sections enclosed by ``B'' class divisions together with particulars of the fire detection and fire alarm systems, the sprinkler installation, the fire-extinguishing appliances, means of access to different compartments, decks, etc. and the ventilating system. Multiple versions were found onboard with the stowage of gear not IAW most recent version. New copies of the most recent version are to be provided onboard to be verified by RO - 30 day w/ verification of gear stowage as approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 24 March 2023 Resolved
The medical certificate provided for in regulation I/9, paragraph 3 shall include the following information as a minimum: Expiry date of certificate: (day/month/year). STCW medical was expired for one of required Oilers onboard. STCW A-1/9.7.3.10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 March 2023
Resolution: Mariner attended a physical exam and submitted CG-719K to the NMC.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 24 March 2023 Resolved
The capacity in which the holder of a certificate is authorized to serve shall be identified in the form of endorsement in terms identical to those used in the applicable safe manning requirements of the Administration. One of required AB’s onboard did not have AB-Deck and National AB endorsement on their credential. STCW I/9
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 28 March 2023
Resolution: Mariner was discharged from the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2023 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Starboard main deck light at frame 96 has broken housing, port side main deck light at bay 06 has a broken mount. 74 SOLAS (97) II-1/40
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 5 June 2023
Resolution: Accepted DNV report of correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. GMDSS battery terminal clamps on fly bridge are deteriorated and required renewal. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 27 March 2023
Resolution: Battery terminal clamps were replaced with new onboard spares.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 24 March 2023 Resolved
The safety management system should include procedures ensuring that non-conformities, accidents, and hazardous situation are provided to the Company, investigated and analyzed with the objective of improving safety and pollution prevention. Non-conformity report for broken stay wire associated with cargo crane no. 2 was reported by the ship on 30NOV2022. Crew later became aware the stay wire caused additional damage to the crane block and hook and replacement of this assembly was required. Captain could not provide records of the subsequent issues and notification to Class Society. ISM Part A/9
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 5 June 2023
Resolution: Accepted DNV report.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 March 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Port Jacobs ladder has improper splice on both sides at the eye connection to the shackle. 74 SOLAS (97) III/19
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 5 June 2023
Resolution: Accepted DNV report of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 March 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Port pilot ladder has frayed grab lines and has reached maximum step renewals. Replace pilot ladder. 74 SOLAS (97) III/19
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 28 March 2023
Resolution: New pilot ladders approved by IMO/USCG were bought and installed aboard the ship.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 March 2023 Resolved
The master, owner, operator, agent, or person in charge of a vessel subject to this subpart and this section must submit a ballast water report to the National Ballast Information Clearinghouse (NBIC) by electronic ballast water report format using methods specified at NBIC’s Web site. NBIC returned submitted report due to use of outdated form and missing information. Resubmit missing information utilizing current form on NBIC website.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 March 2023
Resolution: BWR resubmitted to the NBIC on 3/28/23.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Atomized oil pressure leak found on air compressor #1. 74 SOLAS (97) I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Crew removed piping, replaced gasket and tested under pressure.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. A class boundary penetrated above the fish box (reefer) temperature sensor. 74 SOLAS (20) I/11
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 5 June 2023
Resolution: Accepted DNV report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Oil leaks were noted at the control air for the MDE's. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2023
Resolved 27 March 2023
Resolution: Crew tightened fittings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Patches were found on the freshwater maintenance line to the MDE L/O separator. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 5 June 2023
Resolution: Accepted DNV report of correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Multiple leaks were noted on the condensate return line for the aux boiler. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2023
Resolution: Vessel unlagged the return line and replaced 03 gaskets which repaired the leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. A mechanical coupling from the EDG to its radiator had a backed out securing bolt. 74 SOLAS (20) I/11
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2023
Resolved 27 March 2023
Resolution: Crew resecured the bolt and torqued it to the manufactures specifications.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 24 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Fire alarm call box found heavily damaged on the lower level of the engine room on the port side. 74 SOLAS (20) I/II
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2023
Resolved 27 March 2023
Resolution: Crew removed the damaged call box and replaced with a spare. Tested system satisfactorially.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 June 2022 Resolved
Machinery spaces of category A containing internal combustion machinery shall be provided with a pressure water-spraying system complying with the provisions of regulation 10, & shall be periodically examined and subjected to such tests as the Administration may require. During periodic examination inspectors noted 4 fault alarms (2 from 2021, and 2 from May 23) on the High pressure water mist system. System has been recently serviced by Survitec on May 25 with Class intermediates completed the week after and no discrepancies noted. Complete satisfactory repairs as per OEM. 74 SOLAS (1997) II-2/7.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2022
Resolution: Resolved via DNV attendance following OEM repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship remain fit to proceed to sea. Inspector noted incinerator room ventilation exhaust duct/mesh with extensive corrosion and wastage. 74 SOLAS (2020) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2022
Resolution: Insulation found to be repaired by crew.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Water, pipes, tanks
Issued 14 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship remain fit to proceed to sea. Cargo hold bilge pump discharge piping is corroded, holed and actively leaking at approximately 3 foot section leading to holding tank 32. 74 SOLAS (2020) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2022
Resolution: Discharge piping repaired and verified by RO.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Water, pipes, tanks
Issued 14 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship remain fit to proceed to sea. Inspector noticed pinhole leak on ballast system salt water suction piping located lower level engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 3 July 2022
Resolution: Extended by RO
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 June 2022 Resolved
Electrical installations shall be such that electrical services essential for the safety will be ensured under various emergency conditions. Inspector noticed ground fault on newly installed emergency lighting. Emergency circuit breaker #5 is currently tagged out affecting the life raft lighting on deck 1 & 3. 74 SOLAS (2004) 11-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2022
Resolution: Ground fault resolved and verified by RO
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship remain fit to proceed to sea. Inspector noticed the following items: 1-Emergency Fire pump casing and foundation hardware found in a deteriorated condition. 2-High suction sea chest steam line connection hardware found in deteriorated condition. 74 SOLAS (2020) I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 3 July 2022
Resolution: High suction sea chest steam line connection repairs extended.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 21 September 2021 Resolved
No welding, burning, cutting, or riveting operations involving the use of fire, flame, spark, or arc-producing equipment should be carried out in any space other than machinery spaces and workshops where fire-extinguishing arrangements are available, except in an emergency and, if in port, with authorization of the port authority. Crew conducts hot work and other on the open main deck area with class 1 cargo aboard. Bench with oxy-acetelyne torch and bench grinder all identified as in use in this area. 74 SOLAS (cons.)VII/3 IMDG Part 7.8.6.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2021
Resolution: Revised hot work procedures and objective evidence of crew training were provided to the CG.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 21 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Five of six onboard mooring winches found with significant deterioration of the break bands. 74 SOLAS (cons.) 1/11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 21 September 2021 Resolved
All ships shall have ship-specific plans and procedures for the recovery of persons from the water . The plans and procedures shall identify the equipment intended to be used for recovery purposes and measures to be taken to minimize the risk to shipboard personnel involved in recovery operations. During rescue boat drill multiple crew members were noted leaning over and working adjacent to the side of the ship with all chain guards removed with no life jackets or fall protection. Additionally, the embarkation area for the rescue boat is obscured by an embarkation ladder which the crew has to climb on top of and over to enter the rescue boat. 74 SOLAS (cons) III/17-1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2021
Resolution: Vessel developed/implemented new Man Overboard Procedures and provided objective evidence of crew training. CG Witnessed drill.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2021 Resolved
Class 1 (explosives) may not be stowed within a horizontal distance of 6 m (20 feet) from any source of heat and any possible sources of ignition. (Potential or possible sources of ignition means, but is not limited to, open fires, machinery exhausts, galley uptakes, electrical outlets and electrical equipment including those on refrigerated or heated cargo transport units unless they are of a type designed to operate in a hazardous environment.) Multiple deck lights, including emergency lighting, found within close proximity of all Dangerous Goods cargo holds had loose wires, broken seals, or were not installed properly. Vessel crewmembers could not provide objective evidence the deck lighting or emergency lighting met explosion protection of electrical equipment standards listed on the vessel's Dangerous Goods Document of Compliance. 74 SOLAS (2) CH VII/3, IMDG 7.1.4.4.4, 49 CFR 176.138(b)
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 24 September 2021
Resolution: DNV issued Condition of Authority against DOC. CA required and verified tag-out of all electrical within 6m of Class 1 cargo and prohibited additional loading of class 1 deck cargo.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2021 Resolved
Class 1 (explosives) may not be stowed within a horizontal distance of 6 m (20 feet) from any source of heat and any possible sources of ignition. (Potential or possible sources of ignition means, but is not limited to, open fires, machinery exhausts, galley uptakes, electrical outlets and electrical equipment including those on refrigerated or heated cargo transport units unless they are of a type designed to operate in a hazardous environment.) Multiple open switches, loose wire connectors, and cable splices were found in the Dangerous Goods cargo area of the vessel, immediately adjacent to containerized Class 1.1 and 1.2 Explosives. 74 SOLAS (20) CH. VII/3, IMDG 7.1.4.4.4, 49 CFR 176.138(b)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2021
Resolution: DNV issued Condition of Authority against DOC. CA required and verified tag-out of all electrical within 6m of Class 1 cargo and prohibited additional loading of class 1 deck cargo. Temporary repairs carried out to on deck electrical issues noted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 15 September 2021 Resolved
Ventilators in position 1 or 2 to spaces below freeboard decks or decks of enclosed superstructures shall have coamings of steel or other equivalent material, substantially constructed and efficiently connected to the deck. Multiple areas of full thickness deterioration of steel found in the following locations on the main deck:kick-pipe in the #2 crane breezeway, #3 DB ballast sounding pipe (fiberglass wrapped patch), and a forepeak supply vent. ILLC Reg.19(1)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2021
Resolution: DNV issued Condition of Authority against ILLC. CA required and verified various permanent and temporary repairs made for watertight/weathertight integrity on the main deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 15 September 2021 Resolved
Ventilator openings shall be provided with watertight closing appliances of steel or equivalent material. Significant deterioration of weathertight closure device gasket channels found at following locations: hold 4 aft exhaust, hold 3 supply, forward pipe tunnel access door, and hold 1 supply. The vessel had numerous dogs, closure devices, and handles on weathertight ventilation closure covers leading to cargo holds and other spaces, which were either deteriorated, missing, or misaligned. Additionally, approximately 10 of these closures had severely deteriorated knife edges and gasket channels. ILLC Reg. 19(4)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2021
Resolution: DNV issued Condition of Authority against ILLC. CA required and verified various permanent and temporary repairs made for weathertight integrity to ventilation closures on the main deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 September 2021 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. The means for securing these doors weathertight shall consist of gaskets and clamping devices or other equivalent means and shall be permanently attached to the bulkhead or to the doors themselves, and the doors shall be so arranged that they can be operated from both sides of the bulkhead. Vessels 01 superstructure weathertight doors, port and stbd, found with deteriorated lower gasket channels. ILLC Reg. 12(1)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2021
Resolution: USCG witnessed completion of weld repairs made to the 01 door. DNV verified correction and documented issued in nattative report section of 1649404.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 September 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the number and nature of deficiencies found, objective evidence exists that the vessels safety management system is not being implemented properly. An external ISM audit shall be conducted prior to departure. 74SOLAS(20)Ch.IX/3.1 ISM Part A/10.1
Action required: 30 - Ship detained
Resolved 21 September 2021
Resolution: USCG attended ISM Audit conducted by DNV. See MSO activity for details and Audit report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Firescreen doors 702 and 501A do not close tightly when initiated from the wheelehouse. 74SOLAS(97) Ch.II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2021
Resolved 24 September 2021
Resolution: USCG Witnessed adjustments made to the fire screen doors that ensured proper closing. DNV documented issue and verified correction in narrative section of report 1649404.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 September 2021 Resolved
The company should establish procedures, plans, and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship, and protection of the environment. The various tasks should be defined and assigned to qualified personnel. The vessel does not have procedures, plans, or instructions to ensure weather tight enclosures and emergency lighting are maintained properly. Vessel shall implement and make appropriate changes to their Safety and Quality Management System to rectify missing procedures, plans, and instructions. 74SOLAS(20) Ch.IX/3.1 ISM Part A/7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 28 September 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 September 2021 Resolved
Fire drills should be planned in such a way that due consideration is given to regular practice in the various emergencies that may occur depending on the type of ship and the cargo. Each fire drill shall include; checking the operation of fire dampers. No objective evidence was provided to indicate the crew had ever conducted fire drills which included the removal of the 16 installed dehumidifier lines entering and existing cargo holds 1-4 through the fire dampers. Crew stated that ducting has been in place since 2019 without removal. 74SOLAS(97)Ch.III/18.3.11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 23 September 2021
Resolution: Reviewed ships procedure for cargo hold fire drills and witnessed a partial drill.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Discovered broken fire main pipe bracket located at the forward port corner of the superstructure on the 01 deck. 74SOLAS(20)Ch.I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 28 September 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 15 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The fixed communication (sound powered phone) located in the steering space is inoperable in the event of a steering casualty. 74SOLAS(20)CH.I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 28 September 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 September 2021 Resolved
Bulkheads at exposed ends of enclosed superstructures shall be of efficient construction and shall be to the satisfaction of the administration. Unapproved patch identified on the after end of the engine room ventilation trunk on the 02 deck centerline. ILLC Reg.11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 28 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 15 September 2021 Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve cap in the place. Marine inspector found oxygen and oxyacetylene bottles stored along the port side outboard guard rail at frame 125. 46CFR147.60(b)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 27 January 2022
Resolution: Verified bottles were stored in designated locations and properly secured.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 15 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The current machinery automation test procedures mentioned in the Gap Report are not DNV or USCG approved. 74SOLAS(20)Ch.1/11(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 28 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2021 Resolved
Electrical installations shall be such that the safety of the passengers, crew, and ship from electrical hazards will be ensured. Marine Inspector found a broken emergency lighting support bracket on the aft deck#2, as well as improper electrical installations, severely waster junction box, and multiple dead end wires near center pipe tunnel access aft of cargo hold #4. 74SOLAS(97)CH. II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 28 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2021 Resolved
The carriage of dangerous goods in packaged form shall be in compliance with the relevant provisions of the IMDG code. Goods of class 1 shall not be stowed within a horizontal distance of 6m from potential souces of ignition. Dehumidifiers do not appear to meet the electrical equipment standards listed on vessel's Dangerous Goods Document of Compliance. 74SOLAS(20)CH.VII/3 IMDG 7.1.4.4.4 49CFR176.138(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 28 September 2021
Resolution: Dehudifier system tagged out as part of CA 1649404 due to its current proxmity to Class 1 cargo. Determination for continued use expected from DNV.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 15 September 2021 Resolved
Rescue boats shall be stowed in a state of continued readiness for launching in not more than 5 mins. Vessels rescue boat aft harbor pin was painted in place, the painter was disconnected, and the frapping line was jammed into the engine mount. Launching took 20 mins. 74 SOLAS (97 cons.) III/14.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2021
Resolution: Vessel conducted follow up MOB/rescue boat drills satisfactorially.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 September 2018 Resolved
Vsl is broadcasting incorrect Name
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 October 2020
Resolution: Cleared deficiency at request of NAVCEN. FEACT verified compliance during recent annual inspection.
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 19 July 2017 Resolved
Fire and pollution hazard: Excessive fuel oil in the bilges and bilge well of ship service machinery which constitute safety and fire hazards. Complete cleaning to sat of [name withheld] may verify completion on behalf of USCG.
Condition: Improper/Lack of Maintenance
Due 30 August 2017
Resolved 3 August 2017
Resolution: To satisfaction of class
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 6 July 2017 Resolved
Fire Hazard: Fire door leading to galley from E/R unable to provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkhead. Complete repair to satisfaction of the [name withheld] may verify completion on behalf of USCG.
Condition: Improper/Lack of Maintenance
Due 30 August 2017
Resolved 3 August 2017
Resolution: To satisfacation of class
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 6 July 2017 Resolved
Fire Hazard: Closures for space protected by fixed smothering systems: Ensure ventilation trunk closure is gas tight for the cargo holes protected by the fixed firefighting system. Complete repair to satisfaction of the [name withheld] may verify completion on behalf of USCG.
Due 30 August 2017
Resolved 3 August 2017
Resolution: To satisfaction of class
Construction/Loadline › Penetrations › Gasket
Issued 6 July 2017 Resolved
Trunks and hatches, ullage openings: Ensure the trunk hatch located a the bow are weather tight. Complete repair to satisfaction of the [name withheld] may verify completion on behalf of USCG.
Due 30 August 2017
Resolved 3 August 2017
Resolution: To satisfaction of class
Deck/Cargo › Cargo Stowage › General
Issued 6 July 2017 Resolved
Potential source of ignition means but is not limited to, open fire, machinery exhaust, galley uptake, electrical outlets and electrical equipment including those on refrigerated or heating cargo transport units unless they are of “certified type*” Ensure air conditioning equipment to include dehumidifiers are intrinsically safe.
Due 4 October 2017
Resolved 4 October 2017
Resolution: Item identified during re-flag and address by CVC as not being pertinent to vessel since all related electrical have been isolated. IMDG cert issued by class.
Deck/Cargo › Cargo Stowage › General
Issued 6 July 2017 Resolved
“All hatches and cargo ports opening into a compartment in which Class I material are stowed must be kept closed except during loading and unloading of compartment. After loading, hatches must be securely closed.” Make repair/modification to ensure compliance with requirement.
Condition: Design Flaw
Due 5 October 2017
Resolved 5 October 2017
Resolution: Item discussed and allowed to be installed as is per CVC ([name withheld]).
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 12 July 2016 Resolved
Vessel must complete the ACP enrollment process commenced in 2014.
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 5 June 2018
Resolution: USCG verified ACP enrollment status. Updated MEMO from CVC into MISLE regarding ACP enrollment.
Lifesaving › Lifeboat › Propeller
Issued 12 July 2016 Resolved
Repair cracked / broken propeller guard on the free-fall lifeboat.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 14 July 2016
Documentation › Certificates/Documents › Permit, Other
Issued 12 July 2016 Resolved
Update existing Continuous Synopsis Record sequence to ensure on-board record of the history of the ship is accurate.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 25 August 2016
Resolution: E-mail between CSR desk and managing office stating corrections made.
Construction/Loadline › Structures › Scuttle
Issued 12 July 2016 Resolved
Permanently repair paint locker hatch.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 13 July 2016
Resolution: Hatch coambing and pipe penetration were replaced. Welds were visually inspected by CGMI. vessel to notify class of repair.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 12 July 2016 Resolved
Repair starboard bow life-raft embarkation light. Properly label as such.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 13 July 2016
Resolution: CGMI confirmed proper operation
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 12 July 2016 Resolved
Install life-raft embarkation light and ladder connection on the port side bow and properly label as such.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 23 August 2016
Resolution: Provided e-mail with picture of newly installed ladder attachment points and E-Light
Construction/Loadline › Structures › Door
Issued 12 July 2016 Resolved
Remove super-foam located in the bow-thruster space.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 14 July 2016
Resolution: Corrected.
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 July 2016 Resolved
Temporarily repair hatch coaming to #2 hold forward, starboard side in crane-block #1.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 13 July 2016
Resolution: Permanent repair made
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 July 2016 Resolved
Permanently repair hatch coaming to #2 hold forward, starboard side in the crane-block #1 to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 23 August 2016
Resolution: Permanent repair made to hatch, new pipe penetration fitted. Class has been informed of the repair.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 July 2016 Resolved
Repair Class A Fire Screen Door exiting main galley, port side, and ensure proper closure.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 14 July 2016
Resolution: Corrected.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 12 July 2016 Resolved
Repair Class B Fire Screen Door exiting steward’s passageway, port side, and ensure proper closure.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 14 July 2016
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 July 2016 Resolved
Repair cracked life-rail, frame 140, starboard side.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 13 July 2016
Resolution: Rail was replaced and painted, inspected by CGMI

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.