Records from 1985 to 2006. Most recent: inspection, 27 June 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
27 June 2006
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2693510
30 August 2005
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2480894
25 May 2005
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2361724
7 January 2005
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2270698
14 May 2004
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2047980
27 January 2004
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1994586
23 April 2003
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1779264
26 June 2002
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1637384
3 June 2002
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1626311
15 March 2002
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1597490
11 July 2001
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1076569
25 April 2001
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1437927
19 April 2000
Hull Examination · Re-Inspection · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1386778
30 September 1999
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1118352
18 June 1999
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1384172
4 October 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 8239
14 July 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 68129
1 July 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 76281
15 April 1998
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1388540
16 April 1997
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1441211
27 April 1996
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1435753
15 June 1995
Inclining Experiment · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1187036
9 June 1995
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1185344
2 May 1995
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 868292
1 May 1995
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1349686
6 April 1995
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1153013
8 June 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1321619
26 May 1994
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 861129
11 May 1994
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1387532
14 April 1993
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1366814
14 April 1993
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1370615
27 May 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 955843
5 May 1992
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 954938
19 April 1991
Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 905309
20 April 1990
Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1217622
17 October 1989
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1346729
6 May 1989
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1042330
4 May 1988
Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1200223
2 September 1987
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1002251
16 June 1987
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1312589
21 May 1987
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1335737
30 May 1986
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 990657
6 May 1986
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1006676
29 April 1986
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 993515
19 June 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1289115
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 25 May 2005
Resolved
Provide proof of current FCC station license.
Due 25 June 2005
Resolved 30 August 2005
Resolution: Rcvd fax copy.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 January 2004
Resolved
Re-torque all engine mounts bolts/fasteners on both main engines & double nut center mount bolt. LEGACY COMPONENT DESC: Bedplate
Condition: Unknown
Due 7 February 2004
Resolved 10 February 2004
Resolution: All foundations bolts re-torgue, allsat. Added locking/double nuts to foundation bolts, sat.
Construction/Loadline › Hull
Issued 27 January 2004
Resolved
Repair delamination aft portside corner lazarrette area, forward bow area (Gel Coat), & two STBD side 1" discharges off the hullside. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Due 7 February 2004
Resolved 10 February 2004
Resolution: All done... sat.
Accommodation/Occupational Safety › Messroom › Location
Issued 23 April 2003
Resolved
Secure for sea the Fridge Freezer & Hotplate recently place onboard.
Condition: Improper Installation
Due 23 April 2003
Resolved 23 April 2003
Resolution: Secured.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 23 April 2003
Resolved
Apply matte black to Port & STBD navigation lights.
Condition: Improper Installation
Due 23 April 2003
Resolved 23 April 2003
Resolution: Done next painting period.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 April 2003
Resolved
Missing a CG approved First Aid Kit.
Condition: Placed in Improper Service
Due 23 April 2003
Resolved 23 April 2003
Resolution: Purchase CG Approved First aid Kits.
Lifesaving › Lifejacket/PFD (General)
Issued 3 June 2002
Resolved
Provide 6 Additional Adult PFD's for total of 44 prior to carrying more than 38 persons. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Resolved 26 June 2002
Communications › Audible Communications
Issued 3 June 2002
Resolved
Provide appropriate ships bell for signaling. LEGACY COMPONENT DESC: Bell
Due 3 July 2002
Resolved 26 June 2002
Engineering › Bilge Water Management System
Issued 3 June 2002
Resolved
Provide a sea valve on the electric bilge pump overboard line in the sewage space forward of engine space. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 3 July 2002
Resolved 26 June 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 June 2002
Resolved
Prove operation of the generator-shutdown upon activation of engine room fixed fire system. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Due 3 July 2002
Resolved 26 June 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 3 June 2002
Resolved
Provide heat shields (bowls) on generator and starboard engine Racor fuel filters in accordance with manufacturer's specifications. LEGACY COMPONENT DESC: Filter/Strainer
Condition: Unknown
Due 3 July 2002
Resolved 26 June 2002
Engineering › Steering Gear System
Issued 3 June 2002
Resolved
Repair/replace starboard rudder pillar bearing. LEGACY COMPONENT DESC: Rudder Bearing
Condition: Unknown
Due 3 July 2002
Resolved 26 June 2002
Lifesaving › Lifejacket/PFD (General)
Issued 3 June 2002
Resolved
Separate child/adult life preservers and mark location and number. LEGACY COMPONENT DESC: Storage
Due 3 July 2002
Resolved 26 June 2002
Construction/Loadline
Issued 25 April 2001
Resolved
SECURE E/R BILGE SUCTION LINE AT MANIFOLD
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 25 April 2001
Resolved
REPLACE 7 ADULT AND 2 CHILD TYPE 1 PFD'S. ADULTS REDUCED TO 37, CHILDREN TO3 UNTIL DEFECTIVE PFD'S REPLACED.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Navigation
Issued 25 April 2001
Resolved
PROVE OPERATION OF ANCHOR LIGHT
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Fire Fighting
Issued 25 April 2001
Resolved
SERVICE FIXED FIRE EXTINGUISHING SYSTEM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 25 April 2001
Resolved
REPLACE EPIRB BATTERY PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Engineering
Issued 25 April 2001
Resolved
REPAIR PORT FO REMOTE SHUT-OFF VALVE PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Fire Fighting
Issued 25 April 2001
Resolved
PROVIDE FIREHOSE (5/8") AND NOZZLE, PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Documentation
Issued 25 April 2001
Resolved
DEVELOP AND MAINTAIN CREW TRAINING LOGBOOK
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Navigation
Issued 25 April 2001
Resolved
REPAIR AFT DECK PA SPEAKER
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 25 April 2001
Resolved
CONDUCT UNDERWAY DRILLS WITH NEW CREW
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 25 April 2001
Resolved
PROVIDE 2 PORTABLE LIGHTS
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 19 April 2000
Resolved
TOTAL PERSONS LIMITED TO 25 AFTER 22APR00 UNTIL ANNUAL LIFERAFT SERVICE IS CONDUCTED.
Condition: Unknown
Due 19 April 2000
Resolved 2 May 2000
Lifesaving
Issued 19 April 2000
Resolved
PASSENGERS REDUCED TO 25, TOTAL PERSONS LIMITED TO 27, CHILDREN LIMITED TO 3 UNTIL 17 ADULT AND 3 CHILD LIFEJACKETS ARE REPLACED.
Condition: Unknown
Due 19 April 2000
Resolved 2 May 2000
Fire Fighting
Issued 19 April 2000
Resolved
PERFORM ANNUAL SERVICE ON FIXED FIRE SYSTEM, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 April 2000
Resolved 2 May 2000
Electrical
Issued 18 June 1999
Resolved
Properly terminate dead-end wires under control station.
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Lifesaving
Issued 18 June 1999
Resolved
Replace 11 man lifefloat.
Condition: Unknown
Due 19 June 1999
Resolved 24 June 1999
Fire Fighting
Issued 18 June 1999
Resolved
Istall fixed fire extinguishing system for engine space.
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Construction/Loadline
Issued 18 June 1999
Resolved
Install bilge high
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Accommodation/Occupational Safety
Issued 18 June 1999
Resolved
Show proper operation of marine sanitation device.
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Lifesaving
Issued 18 June 1999
Resolved
Obtain 1 portable flashlight for engine space.
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Engineering
Issued 18 June 1999
Resolved
Properly secure MDE and Generator fuel filters. _x001C_
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Lifesaving
Issued 18 June 1999
Resolved
Install machinery guards on port and starboard MDEs.
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Lifesaving
Issued 18 June 1999
Resolved
Properly stow and mark location of life preservers.
Condition: Unknown
Due 19 June 1999
Resolved 24 June 1999
Lifesaving
Issued 18 June 1999
Resolved
Obtain 6 orange day smokes.
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Navigation
Issued 18 June 1999
Resolved
Show proper operation of horn.
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Deck/Cargo
Issued 18 June 1999
Resolved
Show proper operation of anchor windlass.
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Navigation
Issued 18 June 1999
Resolved
Shpow proper operation of sternlight and raise height for adequate visibility.
Condition: Unknown
Due 19 June 1999
Resolved 24 June 1999
Lifesaving
Issued 15 April 1998
Resolved
Install vessel railing in accordance with 46 CFR 177.900.
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Lifesaving
Issued 15 April 1998
Resolved
Replace damaged heat ducting throughout vessel.
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Navigation
Issued 15 April 1998
Resolved
Repair improper steering connection.
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Accommodation/Occupational Safety
Issued 9 June 1995
Resolved
Provide 42 inch deck rail height and a suitable mesh below the top rail in accordance with 46 CFR 177.35.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Accommodation/Occupational Safety
Issued 1 May 1995
Resolved
Provide written proposal to [name withheld] to increase rail height to meet requirements of 46 CFR 177.35-1(c).
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Navigation
Issued 6 April 1995
Resolved
PROVIDE DEVIATION TABLE FOR MAGNETIC COMPASS.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Lifesaving
Issued 6 April 1995
Resolved
STENCIL LIFEFLOAT CARRYING CAPACITY ON FORWARD LIFEFLOAT IAW _x001C_ 46 CFR 180.20-5(a).
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Construction/Loadline
Issued 6 April 1995
Resolved
PROVIDE WATERTIGHT HATCH COVER FOR CENTER ENGINE SPACE HATCH AND CAPTIVE CHAINS FOR OUTBOARD ENGINE SPACE HATCHES IAW 46 CFR 171.124(a).
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Electrical
Issued 6 April 1995
Resolved
REWRAP WIRE CONNECTOR IN FORWARD CABIN.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Accommodation/Occupational Safety
Issued 6 April 1995
Resolved
PROVIDE WRITTEN PROPOSAL TO OCMI TO INCREASE RAIL HEIGHT REQUIREMENT IAW _x001C_ 46 CFR 177.35-1(c).
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Lifesaving
Issued 26 May 1994
Resolved
Mark lifefloats with person capacity.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Lifesaving
Issued 26 May 1994
Resolved
Remove other vessel's name from lifefloat.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Lifesaving
Issued 26 May 1994
Resolved
Label all lifejacket storage areas with size and number of lifejackets.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Lifesaving
Issued 26 May 1994
Resolved
Provide manufacturers data plate on lifefloat.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Electrical
Issued 11 May 1994
Resolved
PROVE SATISFACTORY OPERATION OF AUXILLIARY GENERATOR.
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Navigation
Issued 11 May 1994
Resolved
REPAIR BRACKET FOR HYDRAULIC STEERING LINES IN LAZARETTE.
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Construction/Loadline
Issued 11 May 1994
Resolved
COMPLETE BONDING OF THRU-HULL FITTINGS.
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Electrical
Issued 11 May 1994
Resolved
CLEAN UP LOOSE WIRING IN ENGINE ROOM AND PILOT HOUSE.
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Electrical
Issued 19 April 1991
Resolved
PROVIDE ONE LINE ELECTRICAL DIAGRAM AND INSTALLATION PLANS FOR THE GENERATOR. INSTALL VOLTAGE, AMP, AND FREQUENCY GUAGES/METERS. GENERATOR NOT TO BE USED UNTIL SYSTEM HAS BEEN APPROVED.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 19 April 1991
Resolved
PROVIDE ADDITIONAL REFLECTIVE TAPE ON SIX ADULT AND ONE CHILD LIFE PRESERVERS BEFORE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Documentation
Issued 19 April 1991
Resolved
SUBMIT DECKHAND QUALIFICATION PLOAN TO MSO ANCHORAGE FOR REVIEW.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Accommodation/Occupational Safety
Issued 19 April 1991
Resolved
PROVIDE GUARDS FOR EACH MAIN ENGINE PULLIES AND BELTS.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Accommodation/Occupational Safety
Issued 19 April 1991
Resolved
DOUBLE HOSE CLAMP ALL FUEL AND ADDITIONAL GENERATOR SEA VALVE HOSE CONNECTION. PROVIDE BOWL FOR RACOR FILTER FOR THE GENERATOR.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Deck/Cargo
Issued 19 April 1991
Resolved
REPAIR WINDLESS FOR THE ANCHOR.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 20 April 1990
Resolved
PROVIDE A PAINTER FOR THE LIFE FLOAT.
Condition: Unknown
Due 20 April 1990
Resolved 20 April 1990
Documentation
Issued 6 May 1989
Resolved
PROVIDE ONBOARD VESSEL CURRENT DOCUMENT
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Fire Fighting
Issued 6 May 1989
Resolved
PROVIDE A B-II FIRE EXTINGUISHER FOR THE GALLEY AREA
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Engineering
Issued 29 April 1986
Resolved
PROVE PROPER OPERATION OF MAIN ENGINES
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Engineering
Issued 29 April 1986
Resolved
PROVE PROPER OPERATION OF BILGE PUMP
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Navigation
Issued 29 April 1986
Resolved
PROVE PROPER OPERATION OF EPIRB AND STENCIL SAME WITH VESSEL NAME
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Lifesaving
Issued 29 April 1986
Resolved
MAKE PERMANENT REPAIR TO TEAR IN 15 MAN LIFE FLOAT AND RE-STENCIL SAME WITH VESSEL NAME.
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Lifesaving
Issued 29 April 1986
Resolved
PROVIDE A PROPERLY MARKED FLOAT FREE WEAK LINK FOR THE 15 MAN LIFE FLOAT AND PROPERLY INSTALL WITH WATER LIGHT.
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986