Records in 1999. Most recent: inspection, 20 December 1999.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Navigation
Issued 5 May 1999
Resolved
Provide operating instructions for steering on bridge and aft steering.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Fire Fighting
Issued 5 May 1999
Resolved
Repair or replace with new pipe, two soft patches on the stbd side main deck fire main.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 5 May 1999
Resolved
Conduct and log visual inspection of survival appliances every week.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Navigation
Issued 5 May 1999
Resolved
Provide charts, coast pilot, rules to the road (nav rules), code of signalson board for U.S. ports that the vessel will be transiting.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Accommodation/Occupational Safety
Issued 5 May 1999
Resolved
Provide a watch list for the crew.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Navigation
Issued 5 May 1999
Resolved
Provide maneuvering fact sheet for vessel on the bridge.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Engineering
Issued 5 May 1999
Resolved
Provide Oil Transfer Proceedures on board and use them while conducting fuel operations.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Electrical
Issued 5 May 1999
Resolved
Provide light covers on lights located in mutiple areas of the ship.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Engineering
Issued 5 May 1999
Resolved
Provide a proper working OWS. Sensor/alarm was not operating correctly. _x001C_Vessel shall retain all oil slops onboard until repaired
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Fire Fighting
Issued 5 May 1999
Resolved
Provide Class report that the vessel is allowed to use 2 ballest pumps (which are located in the engine room, same compartment) as their main and emergency fire pumps.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 5 May 1999
Resolved
Provide a No Discharge of Oil sticker/placard in the engine room.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Fire Fighting
Issued 5 May 1999
Resolved
Provide proper life lines on each firemans outfit.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Navigation
Issued 5 May 1999
Resolved
Conduct and log general alarm test weekly.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Navigation
Issued 5 May 1999
Resolved
Conduct and log quarterly emergency steering drills.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999