MAURY USCG vessel records
← All vessels

KINGPIN

Built
1977
Last inspected
11 June 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 June 2025
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ4139
Flag
UNITED STATES
Maury page id
psix-49469

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.1 ft × 6.0 ft
Registered tonnagegross 36 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYANK BOAT WORKS · TUCKAHOE, NJ, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCORTEZ, FL
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 11 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 81 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

11 June 2025 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8161873
15 May 2025 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8136735
25 February 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8084616
13 January 2025 Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8063081
4 June 2024 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7926766
4 October 2023 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7802159
6 October 2022 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7571884
16 August 2021 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7276031
17 June 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7232471
14 September 2020 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7057646
3 June 2020 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7004902
8 May 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6950503
29 April 2019 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6671041
10 January 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6604016
8 December 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6310984
27 September 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6270234
3 May 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6137787

Deficiency record · 81

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2025 Resolved
46 CFR 182.455(b)(4) Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. MI observed the port side remote fuel shutoff valve was inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2025
Resolved 5 September 2025
Resolution: Reach rod was replaced. Valves is able to be remotely operated.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 4 September 2025 Resolved
46 CFR 180.137(b) The float free line on an inflatable buoyant apparatus must be secured to the painter at one end and to the vessel on the other end. MI observed the float free link and hydrostatic release installed improperly such that the apparatus would not float free.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2025
Resolved 5 September 2025
Resolution: Hydrostatic release was properly configured.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 September 2025 Resolved
46 CFR 181.420 A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. MI observed that while the main engines did shut down upon activation of the system, the engines were able to restart without the override switch being activated. Owner/Operator shall provide a report from a qualified technician attesting to the satisfactory operation of the system upon repair.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2025
Resolved 6 September 2025
Resolution: Received report from [name withheld] attesting to satisfactory operation of system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 September 2025 Resolved
46 CFR 181.500(b) A portable fire extinguisher located in the vessel’s operating station must be rated 10-B:C. MI observed the extinguisher in the operating station was 1-A and therefore undersized.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2025
Resolved 5 September 2025
Resolution: Fire extinguisher was replaced.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 September 2025 Resolved
46 CFR 176.810(d) At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. During inspection the required crew were not available to conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2025
Resolved 5 September 2025
Resolution: Conducted satisfactory drill.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 4 September 2025 Resolved
46 CFR 176.808(g) At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. During inspection the required crew were not available to conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2025
Resolved 5 September 2025
Resolution: Conducted satisfactory drill.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 4 September 2025 Resolved
46 CFR 185.420(d) Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill log book was not made available to the MI during the inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2025
Resolved 5 September 2025
Resolution: Drill log was created.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2025 Resolved
46 CFR 180.70(c) At least one life ring buoy must be fitted with a lifeline. The lifeline connected to the ring buoy was frayed, compromising the integrity and strength of the line, and line was attached to ring buoy with a clip that was stuck in the open position.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2025
Resolved 5 September 2025
Resolution: Line and clip were replaced.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 4 September 2025 Resolved
46 CFR 184.710 A vessel must carry either a first-aid kit or a kit with equivalent contents and instructions. MI observed the first aid kit on board was expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2025
Resolved 5 September 2025
Resolution: First aid kit was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 September 2025 Resolved
46 CFR 183.420 All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed the anchor light’s arc of visibility was impeded by a deck light installed on top of the pilothouse. Vessel is restricted to operations during daytime with 3 NM of visibility only.
Action required: 705 - Other - as specified
Resolved 5 September 2025
Resolution: Deck light was adjusted so that it was not blocking anchor light.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 September 2025 Resolved
46 CFR 181.450 The vessel is required to have an interconnected detection and alarm system installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 8 October 2025
Resolution: Received video of system working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2025 Resolved
46 CFR 177.35-15 Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 5 September 2025
Resolution: Machinery guard was installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2025 Resolved
46 CFR 111.01-1 Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. MI observed the following electrical hazards. 1. Dead end wires on the overhead of the pilothouse 2. Generator harness with butt connectors that are exposed and in need of heat shrink. 3. A battery in the machinery space bilge that is not connected to anything.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 5 September 2025
Resolution: Dead end wires removed, connectors were heat shrunk, and battery was removed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 September 2025 Resolved
46 CFR 176.810(b)(1)(ii) The owner, operator, person-in-charge, or a designated member of the crew must conduct monthly inspections of portable fire extinguishers required by NFPA 10. There were no monthly inspections logged by the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 6 September 2025
Resolution: Received picture of inspectiono log.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 4 September 2025 Resolved
46 CFR 185.510(a) The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 5 September 2025
Resolution: Emergency instructions were created and posted at operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 September 2025 Resolved
46 CFR 183.430 Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 5 September 2025
Resolution: Portable lights were onboard.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 4 September 2025 Resolved
46 CFR 176.306 The stability letter must be poster under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. There was no stability letter posted on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 5 September 2025
Resolution: Stability letter was posted.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 September 2025 Resolved
46 CFR 176.302 The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible. There was no COI posted on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 8 October 2025
Resolution: Received picture of COI posted on vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 4 September 2025 Resolved
46 CFR 16.401(b) An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. There was no record of training on the EAP program available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 2 October 2025
Resolution: Picture of recorded EAP training was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 4 September 2025 Resolved
46 CFR 180.210 (b) A vessel of not more than 19.8 meters (65 feet) in length is not required to carry a rescue boat unless: The cognizant OCMI determines that the vessel is designed, arranged, or involved in operations so that the vessel itself cannot serve as an adequate rescue craft. Vessel's rescue ladder does not meet the specific guidelines as per Sector St. Petersburg's Work Instruction MPS-WI-SECSP, Rescue Platforms as an Alternative to Rescue Boats on Small Passenger Vessels. Specifically, MI's observed that the rescue ladder was not equipped with an appropriate platform landing of at least 36 X 36 inches. Ammended on 14OCT25 to: The cognizant OCMI has determined that the vessel is designed, arranged, or involved in operations such that it cannot serve as an adequate rescue craft. During a demonstration of helpless person recovery, the Marine Inspector observed that the recovery method was unsatisfactory. The vessel shall propose procedures and demonstrate a safe and effective method for recovering a helpless person from the water. This deficiency was amended on October 14th, 2025 as explained within letter 16710/25-176. Action is required by November 13th, 2025. This deficiency was amended on November 14th, to code 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2025
Resolved 24 November 2025
Resolution: Witnessed satisfactory man overboard recovery using sling and pole arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 June 2025 Resolved
Each vessel operating on a coastwise route in warm water must be provided with life floats to acommodate 100% of toal number of persons onboard. Vessel only has 1 life float accommodating 22 people. Passenger count is limited to 20 until a second life float is onboard. Total persons allowed is now 22. 46 CFR 180.204 705(c)
Action required: 705 - Other - as specified
Resolved 5 September 2025
Resolution: Vessel elected to purchase a 25 person IBA which meets the 67% requirement of being on oceans route in warm water. Carrying IBA exceeds the life float requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 June 2025 Resolved
Each vessel operating on a coastwise route in warm water must be provided with life floats to acommodate 100% of toal number of persons onboard. Life raft was still in the box on the pier. Evidence of the raft properly stowed, and equipped on the vessel must be provided prior to carring passengers. 46 CFR 180.204
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2025
Resolved 10 June 2025
Resolution: Photos showing the life float properly mounted on the vessel were provided.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 May 2025 Resolved
A visual and audible alarm at the operating station must be in place. The E/R and steering compartment high water alarms are not working. Must be fixed prior to passengers. 46 CFR 182.530 701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2025
Resolved 10 June 2025
Resolution: Received video of operational high level alarms.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 February 2025 Resolved
The master shall conduct sufficient drills and give sufficient instructions ensure that all crew members are familiar with their duties during emergencies. Upon arriving to new to home port, vessel master and crew shall obtain new to zone inspection and successfully run abandon ship, man overboard, and fire fighting drills in the presence of attending Coast Guard Marine Inspector prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: Observed satisfactory drills.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 January 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. Vessel is overdue for the required dry dock inspection required by 46 CFR 176.600 and is restricted to carrying passengers until a drydock is completed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2025
Resolution: Drydock complete
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Inspector observed battery connections to terminals held in place by alligator clips and no cover intact. Operator to fix.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. witnessed batteries installed with proper connections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2024 Resolved
All observed unsafe practices, fire hazards, and other hazardous situations must be corected. All required guards and protective decies must be in satisfactory condition. Vessel missing machinery guards on main diesel engines and generator.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I witnessed installation of machinery guards.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 June 2024 Resolved
Electric equipment must be maintained to protect from electrical hazards. Vessel had exposed wires and A/C drain water leaking onto electrical components. Operator to repair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. witnessed new A/C drain hoser installed and routed to avoid electrical equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2024 Resolved
A vessel of at least 26 feet a visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned space. Vessels visual bilge alarm and pump indicators weren't operable. Operator to repair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I witnessed testing and operation of 03 bilge high level alarms and the operation of the automatic bilge pump and indicator light.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 June 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel could not provide satisfactory proof of random drug test program for all crew members. Operator to enroll crew in program.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I ensured all crew were enrolled in DAPI program and had received a pre-employment drug test.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 June 2024 Resolved
Electric equipment must be maintained to protect from electrical hazards. Vessel had exposed wires on bridge. Operator to remove or cover exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I witnessed all loose or bare wires on the bridge secured or removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 June 2024 Resolved
At every vessel inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected. Vessel had batteries, empty containers, dead end wires, pipe wrench and lighters adrift. Operator to secure gear in appropriate places.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. inspected bilges and found all hazards removed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 June 2024 Resolved
Provisions must be made for closing all supply ducts, supplies or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Engine room was not made vapor tight. Operator to correct.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. ensured engine room was made vapor tight.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 June 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the Int'l and Inland Navigation rules. Anchor light is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I witnessed operation of new anchor light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Engine mount bolt sheared, to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I inspected affected engine mount and found it to have been repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 June 2024 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Operator to install fixed mechanical plug.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I observed a bolt installed in the strainer bowl.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 June 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not have installed interconnected fire detection system; operator to rectify.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. witnessed installation and operation of interconnected smoke detection system.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 June 2024 Resolved
The operator shall have each hydrostatic release unit in compliance with the servicing and usage requirements. Inflatable buoyant apparatus hydrostatic release expired. Operator to replace with new release unit.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I observed installation of new hydrostatic release unit.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 June 2024 Resolved
Each life float and buoyant apparatus must be stowed as required and secured to the painter at one end and to the vessel on the other end. release mechanism was mounted upside down and note secured to IBA mounting bracket. Operater to mount release mechanism upright and secure to painter and vessel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed IBA release mechanism installed per manufacturers specifications.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 June 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2-1/2 gallon) buckets, with an attached lanyard satisfactory to cognizant OCMI, placed so as to be easily available during an emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Marine Inspector noted only two buckets present, without lanyards, and not labeled. Operator to procure the third bucket, fit with lanyards, and labeled.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed required fire buckets with lanyards.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 June 2024 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI. Vessel is certificated to have three portable fire extinguishers. Marine inspector noted extinguisher in forward salon area was not adequately charged. Operator to replace with charged extinguisher or recharge existing extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed installation of new fire extinguisher.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine inspector noted vessel's bilges full of oil and cleaning agents. Operator to remove standing liquid and dry the bilges.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed bilges free of oil and cleaning agents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine Inspector observed bilge suction pickups with excessive debris nearby. Operator to remove debris to prevent clogging.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed bilges free of debris near bilge suction pickups.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 June 2024 Resolved
A hatch exposed to the weather must be watertight, a hatch cover must have securing devices. Marine inspector noted the chain locker hatch cover on the main deck incapable of being secured. Install necessary hardware to secure the hatch.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. inspected 02 latches installed on forward hatch.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 June 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Marine Inspector noted the vessel's EPIRB registered to the wrong vessel. Operator to register EPIRB to correct named vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 22 October 2024
Resolution: Proof of registration provided to satisfaction of inspector.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 June 2024 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each Emergency Position Indicating Radio Beacon (EPIRB). Operator to label EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 22 October 2024
Resolution: Proof of name provided to satisfaction of inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Marine Inspector noted life jackets and ring buoy marked with vessel's old name. Operator to mark the life jackets and ring buoy appropriately.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 28 August 2024
Resolution: COD updated with new vessel name. Name matches life jackets and ring buoy.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 5 June 2024 Resolved
Placards containing instructions for donning and use of life jackets aboard vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Marine inspector noted no instructions on vessel. Operator to mount placard for model of life jacket found on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed a donning placard in place on the bulkhead.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 June 2024 Resolved
Each vessel must be equippred with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Marine inspector noted no portable light at the operating station. Operator to procure and install portable light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed a second portable light brought onto the vessel for use at operating station or engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Marine Inspector noted the vessel's fuel shutoff valves not marked with direction of operation. Operator to label shutoffs.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed fuel shutoffs labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 5 June 2024 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for size of the vessel. Marine inspector noted a cleat for mooring missing on bow of vessel. Operator to affix a cleat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed insatallation of a forward cleat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine inspector observed the engine room lights inoperable. Operator to repair the light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed the repair of engine room lights.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
All electrical equipment must be permanently grounded to the hull on a vessel. Marine inspector observed the starboard raw water pump not grounded. Operator to install grounding strap.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed installation of a grounding wire.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024 Resolved
Electric equipment must be maintained to protect from electrical hazards. Vessel has loose wires in engine room and starboard bow light. Operator to remove or cover exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed loose wires removed.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 5 June 2024 Resolved
A vessel must comply with applicable design, equipment, personnel, procedures, and record requirements of 33 CER parts 151. Marine Inspector observed the Waste Management Plan with the name of another vessel. Operator to Ensure Garbage Management plan is updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed the mounting of a garbage management plan placard on the bulkhead for the current vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine Inspector observed a drain in the engine room dripping water onto the mounting plate for the starboard engine. Operator to route drain to bilge away from machinery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 6 February 2025
Resolution: Drain piping re-routed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to inspect of all machinery essential to the routine operation of the vessel. Marine Inspector noted missing starboard engine turbo filter cover. Operator to replace cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. witnessed installation of turbo cover.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 June 2024 Resolved
Provisions must be made closing eli supply ducts, supplies or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Operator to make engine room vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. inspected engine room and found to be reasonably vapor tight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 June 2024 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction. Marine Inspector observed a broken railing on the bow. Operator to secure railing to the deck; no passengers allowed on the bow until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 10 June 2024
Resolution: M.I. observed the railing repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 5 June 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC—licensed technician once every five years and be issued a Communications Act Safety Radiotelephony Certificate. Marine inspector observed no radiotelephony certificate on board. Operator needs to receive required FCC inspection and obtain the certificate prior to operating beyond 3NM.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 5 September 2024
Resolution: Proof of new radiotelphony certificate provided and uploaded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2023 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the [name withheld] bracket in Pilot House. Install fire extinguisher in approved bracket in Pilot House. 46 CFR 181.30-10(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2023
Resolution: O/O provided photo / video evidence of required fire extinguisher bracket mounted at operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 October 2023 Resolved
FRP vessel op'ing on limited coastwise route in cold water must have life float for 100% of persons onboard. Inflatable Buoyant Apparatus (IBA) absent. Replace and properly stow the IBA currently out for servicing. 46 CFR 180.205(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2023
Resolution: O/O provided photo and video of IBA returned from service facility, w/ current inspection / service decal and stowed / arranged onboard.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 October 2023 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB installed to automatically float free and activate. Vessel EPIRB's hydrostatic release was expired. Vessel will restrict operations to w/in 3 miles of land or replace and properly mark new EPIRB hydrostatic release to operate in accrd w/ COI. 46 CFR 180.64
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: O/O provided photo / video evidence of new EPIRB HRU marked with date and installed in EPIRB bracket.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 October 2023 Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. ENG Rm ventilation cover missing fastener for fire damper. Replace missing fastener. 46 CFR 181.20-35(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2023
Resolution: O/O provided photo evidence of E/R vent intake cover mounted and in operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 October 2023 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Missing stbd fwd engine mounting bracket missing nut. Replace nut. 46 CFR 182-05-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2023
Resolution: O/O provided photo and video of MDE mounting nut being replaced and secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2023 Resolved
The vessel owner or operator must pay the annual vessel inspection fee each year on or before the vessel's user fee anniversary date, unless the fee has been prepaid under 46 CFR 2.10-105. Vessel has not paid user fee's. Vessel rep will provide proof of payment. 46 CFR 2.10-101(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2023
Resolution: O/O provided acceptable proof of User Fee payment.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 October 2022 Resolved
The fuel shutoff valve shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Vessel is missing a reach rod to assist in the accessibility of the fuel shut off valves from the weather deck.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 October 2022
Resolved 4 October 2023
Resolution: Observed Fuel shut-off valves operating.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 6 October 2022 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. The vessel's liferaft is missing a hydrostatic release.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2022
Resolved 4 October 2023
Resolution: Survival craft stowed / arranged with HRU in place.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2022 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The ring buoy is not marked.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 October 2022
Resolved 4 October 2023
Resolution: Life ring inspected sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2022 Resolved
Each ring life buoy must be marked with Type II retro reflective material approved in 46 CFR 164.018. The reflective tape on the ring buoy is worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2022
Resolved 4 October 2023
Resolution: Life ring inspected sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2022 Resolved
Each ring life buoy on a vessel must be stowed in a way that it can be rapidly cast loose. The ring buoy was not properly stowed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 October 2022
Resolved 4 October 2023
Resolution: Life ring stowed properly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 October 2022 Resolved
For sternlights and masthead lights and at 22.5 degrees abaft the beam for sidelights, the minimum required intensities shall be maintained over the arc of the horizon up to 5 degrees within the limits of the sectors prescribed in Rule 21. Vessel's stern light and masthead light are inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2022
Resolved 4 October 2023
Resolution: Nav lights tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 September 2020 Resolved
Prove proper operation of MDE to the satisfaction of an attending MI. Vessel may not carry passengers for hire until underway tests and emergency drills are completed in the presence of an attending MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2021
Resolution: MI witnessed operation of machinery and emergency drills.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 September 2020 Resolved
Provide flares for vessel prior to operating with passengers for hire.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2021
Resolution: MI witnessed the flares onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 May 2020 Resolved
Vessel failed to meet requiremnets in 46 CFR 176.500 and complete annual inspection within the inspection window
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2020
Resolved 3 June 2020
Resolution: Completed annual inspection IAW 46 CFR 176.500(b)(1). re-activated vessel in vessel details.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 January 2019 Resolved
Provide log book for drills, training and EPIRB tests. 46CFR185.520(f), 185.524(d), 188.728
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 10 July 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 January 2019 Resolved
Provide copy of FCC Station License. 47CFR80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 10 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 January 2019 Resolved
Provide light list, coast pilot and tide tables. 46CFR184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 10 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 January 2019 Resolved
Replace battery in ring buoy light. 46CFR180.71(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 10 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 January 2019 Resolved
Re-label ring life buoy with vessel name. 46CFR604(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2019
Resolved 10 July 2019
Lifesaving › Hand Flares › Expired
Issued 8 December 2017 Resolved
Replace 6 expired flares.
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 8 December 2017
Resolution: Corrected on the spot.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.