← All vessels
SWIFT ARROW
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northwest District (CGD-NW) · Other hulls named SWIFT ARROW
SWIFT ARROW is a 1977 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1981, most recently in May 2026, along with 50 deficiencies.
Records from 1981 to 2026. Most recent: inspection, 19 May 2026.
- Built
- 1977
- Last inspected
- 19 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 50 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
588779
WAFK
49476
Flag
UNITED STATES
369021000
Maury page id
psix-49476
Inspections, by type
…with no type recorded14
Years with a record
42 calendar years (1981–2026)
The 78 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 25 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT, INC. · LOREAUVILLE, LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT ANGELES, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WAFKMMSI 369021000 · active · compulsorily equipped · granted 19 May 2021, expires 24 July 2031
WBC8721MMSI not assigned · expired · compulsorily equipped · granted 9 October 1996, cancelled 24 February 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 78
19 May 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8376625
12 May 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8371933
21 January 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8064237
30 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7904205
28 March 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7884888
23 March 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7658048
18 April 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7422437
22 March 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7435206
18 March 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7158624
20 May 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6956805
21 April 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6942113
3 January 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6882448
8 April 2019
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6658123
11 April 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6390328
3 April 2018
Damage Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6384642
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360536
9 November 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6037577
27 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5844604
22 October 2015
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5748509
2 February 2012
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4237949
6 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202745
5 January 2010
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3658544
1 April 2009
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3448292
7 May 2008
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3199326
16 April 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3184060
18 January 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2857878
13 July 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2711615
11 January 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2565367
18 January 2005
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2278709
7 July 2004
Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2124887
17 July 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1851476
5 July 2002
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1639465
5 July 2001
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1399665
23 January 2001
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1057565
9 March 2000
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365622
27 January 2000
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376030
11 March 1999
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1455679
2 June 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 3844
16 March 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378342
9 February 1998
Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1455558
21 March 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368131
12 March 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 886291
6 March 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396463
26 January 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374473
15 March 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357062
19 August 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 706048
18 August 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 369694
31 March 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1407278
17 March 1994
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366998
22 February 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 139044
12 January 1994
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362905
13 July 1993
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 846106
12 May 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1143584
6 April 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 837483
24 March 1993
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1149037
14 April 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1264772
31 March 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 940163
6 November 1991
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 936704
20 December 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 919672
12 July 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 929838
17 May 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1246146
14 December 1989
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1215173
17 October 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1194253
17 November 1988
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1210371
5 August 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039729
15 July 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032550
27 April 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039846
29 December 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1007593
16 November 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1022313
27 July 1987
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1022424
13 January 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1314402
27 June 1986
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305403
27 March 1986
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305121
28 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977636
13 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972426
6 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964657
21 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273143
16 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970569
Deficiency record · 50
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2022
Resolved
Noted fuel leaking from supply piping/hose at the tank connection. Repair piping system to stop leaks.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2019
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arrestors. Flame screens were painted over.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2019
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). portable bilge pump suction and discharge were reversed and would not reach lowest point in bilge.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 February 2012
Resolved
Install proper water light lanyard. Lanyard was about 10 feet long. 46 CFR 180.71(d)(2)
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 February 2012
Resolved
Provide lifejackets for each person onboard. Limited to 23 persons until corrected. 46 CFR 180.71
Electrical › Electrical Distribution System (service) › Cable
Issued 2 February 2012
Resolved
Secure wiring with metal brackets and chafing gear. 46 CFR 183.340(b)2(4)
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 April 2008
Resolved
Replace waterlight on lifefloat.
Lifesaving › Lifefloat › Float-free Link
Issued 16 April 2008
Resolved
Provide proper installation of painter and weak link or research rafting both life floats onto one weight appropriate weak link.
Engineering › Steering Gear System › Rudder Stock
Issued 13 July 2006
Resolved
Aft side of port rudder tube approx 3" below packing gland pitted. Grind and weld.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 July 2006
Resolved
Total of 4 approx 1/2" threaded holes located in fwd engine room bulkhead, 3 ft outboard of centerline, two on each side port and stbd. Plugs holes.
Lifesaving › Rigid Liferafts › Markings
Issued 17 July 2003
Resolved
The life floats were not properly marked with passenger capacity.
Lifesaving
Issued 11 March 1999
Resolved
Found class A 121mhz EPIRB in use. Replace existing EPIRB with CAT I 406 mhz EPIRB in accordance with 46 CFR 180.64 prior to traveling more than 3nmfrom shore while carrying passengers.
Fire Fighting
Issued 11 March 1999
Resolved
Belt driven attached fire pump leaked in engineroom and did not provide pressure to hose. Demonstrate proper operation of power driven fire pump.
Navigation
Issued 6 March 1996
Resolved
PROPERLY SECURE OVERHEAD STEERING CABLES IN LAZARETTE/STEERING VOID.
Electrical
Issued 6 March 1996
Resolved
INSTALL BULB IN PORT FIXTURE AND INSTALL TWO PROTECTIVE LENSES FOR BOTH OVERHEAD LIGHTING FIXTURES IN FORWARD ELECTRICAL VOID.
Accommodation/Occupational Safety
Issued 18 August 1994
Resolved
ON 18AUG94, THE MASTER, PAUL POLLO, OF THE MOTOR VESSEL HAPAI OWNED BY P & R WATER TAXI, A U.S. DOCUMENTED OCEANGOING SHIP GREATER THAN 40 FEET IN LENGTH, WAS NOT MAINTING A WRITTEN RECORD OF GARBAGE DISCHARGE OR DISPOSAL OPERATIONS.
Construction/Loadline
Issued 17 March 1994
Resolved
PROVIDE SUCTION STRAINER FOR PORTABLE BILGE PUMP IAW 46 CFR 182.25-5.
Navigation
Issued 17 March 1994
Resolved
PROVIDE CURRENT NAVIGATION CHARTS.
Documentation
Issued 17 March 1994
Resolved
PROVIDE PROOF OF VALID FCC OPERATORS LICENSE.
Construction/Loadline
Issued 17 March 1994
Resolved
PROVE PROPER OPERATION OF VESSEL BILGE PUMPS. VESSEL IS PROHIBITED FROM CARRYING PASSENGERS UNTIL OPERATION OF THE BILGE SYSTEM IS PROVED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Accommodation/Occupational Safety
Issued 17 March 1994
Resolved
INSTALL A SAFETY RAIL FOR ELECTRIC COOKING EQUIPMENT (TWO BURNER RANGE) IAW46 CFR 183.10-45(B)(3). COOKING EQUIPMENT IS NOT TO BE USED UNTIL THIS ITEM IS CORRECTED.
Navigation
Issued 12 January 1994
Resolved
PRIOR TO CARRYING PASSENGER FOR HIRE, PROVE PROPER OPERATION OF THE VESSELSSTEERING SYSTEM AND MAIN ENGINES. _x001C_ _x001C_ _x001C_
Documentation
Issued 24 March 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical
Issued 24 March 1993
Resolved
Cap all of the ends to the loose wiring located behind the switchboard on the bridge.
Engineering
Issued 24 March 1993
Resolved
Install heat shields on the port and starboard Racor filters located in themachinery space.
Electrical
Issued 31 March 1992
Resolved
PROVIDE GUARD FOR BELT AND PULLEY SYSTEM OF RAW WATER PUMP ON DIESEL GENERATOR.
Engineering
Issued 31 March 1992
Resolved
PROVIDE GUARD FOR BELT AND PULLEY SYSTEM OF BILGE/FIRE PUMP ON STARBOARD PROPULSION ENGINE.
Electrical
Issued 31 March 1992
Resolved
SUBMIT NEW ELECTRICAL DIAGRAM TO MSO HONOLULU FOR APPROVAL
Lifesaving
Issued 31 March 1992
Resolved
PROVIDE BATTERY FOR EPIRB.
Documentation
Issued 31 March 1992
Resolved
PROVIDE SAFETY RADIOTELEPHONY CERTIFICATE WITH VESSEL NAME CHANGE.
Fire Fighting
Issued 31 March 1992
Resolved
PROVIDE ON BOARD OPERABLE HAND FIRE PUMP.
Engineering
Issued 20 December 1990
Resolved
REPAIR EXHAUST LEAKING ON BOTH PORT & STBD MDE EXHAUST PIPING_x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 20 December 1990
Resolved
REPAIR BOTH PORT & STBD ENGINE ROOM VENT COVERS AND PROVE ITS OPERATION
Accommodation/Occupational Safety
Issued 20 December 1990
Resolved
INSTALL INSECT SCREENING TO FRESH WATER VENT_x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 20 December 1990
Resolved
REPAIR OR REPLACE EPIRB
Unknown
Issued 20 December 1990
Resolved
REPLACE 18 LIGHTS TO 18 PFD'S
Engineering
Issued 20 December 1990
Resolved
RELAG BOTH MDE EXHAUST PIPING FWD OF COOLING INJECTION.
Electrical
Issued 20 December 1990
Resolved
CLEAN AND REFASTEN ACC BATTERY TERMINALS
Electrical
Issued 20 December 1990
Resolved
REMOVE ROMEX WIRING TO BILGE PUMP AND INSTALL MARINE GRADE WIRING_x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 20 December 1990
Resolved
REWELD BULKWARK ON PORT BOW IN WAY OF VESSELS NAME._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 20 December 1990
Resolved
PROVIDE COAST GUARD APPROVED FLOAT FREELINK FOR LIFEFLOAT.
Lifesaving
Issued 14 December 1989
Resolved
RENEW EPIRB BATTERY.
Lifesaving
Issued 14 December 1989
Resolved
RENEW 1 APFD WATERTIGHT BATTERY.
Construction/Loadline
Issued 15 July 1988
Resolved
INSTALL CAPTIVE CHAINS TO BOTH WEATHER DECK HATCHES PRIOR TO VESSEL OPERATIONS.
Documentation
Issued 15 July 1988
Resolved
CONDUCT STABILIITY TEST IN THE PRESENCE OF A CG MARINE INSPECTOR. DO NOT OPERATE VESSEL BEYOND 50 NAUTICAL MILES FROM SHORE UNTIL THIS STABILITY TEST IS COMPLETED TO THE SATISFACTION OF THE [name withheld], AL.
Documentation
Issued 27 July 1987
Resolved
REDOCUMENT VESSEL TO COASTWISE REGISTRY OR SURRENDER CERTIFICATE OF INSPEC-TION.
Construction/Loadline
Issued 27 March 1986
Resolved
REPAIR THE CRACKED TACK WELD ON THE TRANSVERSE FRAME UNDER THE PASSENGER AREA.
Documentation
Issued 27 March 1986
Resolved
PROVIDE THE VESSSEL WITH A CURRENT CERTIFICATE OF DOCUMENTATION SHOWING THE CHANGE OF VESSEL NAME AND OWNERSHIP.
Documentation
Issued 27 March 1986
Resolved
PROVIDE THE VESSEL WITH A CURRENT FCC RADIO STATION LICENCE.
Engineering
Issued 27 March 1986
Resolved
REMOVE OR REPAIR THE INOPERATIVE MAIN ENGINE RPM GAUGES ON THE BRIDGE CONSOLE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.