MAURY USCG vessel records Sign in
← All vessels

SWIFT ARROW

SWIFT ARROW is a 1977 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1981, most recently in May 2026, along with 50 deficiencies.

Records from 1981 to 2026. Most recent: inspection, 19 May 2026.

Built
1977
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
369021000
Maury page id
psix-49476

Inspections, by type

…with no type recorded14
Years with a record 42 calendar years (1981–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 25 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT, INC. · LOREAUVILLE, LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT ANGELES, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAFKMMSI 369021000 · active · compulsorily equipped · granted 19 May 2021, expires 24 July 2031
WBC8721MMSI not assigned · expired · compulsorily equipped · granted 9 October 1996, cancelled 24 February 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 78

19 May 2026 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8376625
12 May 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8371933
21 January 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8064237
30 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7904205
28 March 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7884888
23 March 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7658048
18 April 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7422437
22 March 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7435206
18 March 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7158624
20 May 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6956805
21 April 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6942113
3 January 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6882448
8 April 2019 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6658123
11 April 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6390328
3 April 2018 Damage Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6384642
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360536
9 November 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6037577
27 April 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5844604
22 October 2015 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5748509
2 February 2012 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4237949
6 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202745
5 January 2010 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3658544
1 April 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3448292
7 May 2008 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3199326
16 April 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3184060
18 January 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2857878
13 July 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2711615
11 January 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2565367
18 January 2005 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2278709
7 July 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2124887
17 July 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1851476
5 July 2002 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1639465
5 July 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1399665
23 January 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1057565
9 March 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365622
27 January 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376030
11 March 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1455679
2 June 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 3844
16 March 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378342
9 February 1998 Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1455558
21 March 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368131
12 March 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 886291
6 March 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396463
26 January 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374473
15 March 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357062
19 August 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 706048
18 August 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 369694
31 March 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1407278
17 March 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366998
22 February 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 139044
12 January 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362905
13 July 1993 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 846106
12 May 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1143584
6 April 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 837483
24 March 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1149037
14 April 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1264772
31 March 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 940163
6 November 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 936704
20 December 1990 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 919672
12 July 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 929838
17 May 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1246146
14 December 1989 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1215173
17 October 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1194253
17 November 1988 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1210371
5 August 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039729
15 July 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032550
27 April 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039846
29 December 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1007593
16 November 1987 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1022313
27 July 1987 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1022424
13 January 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1314402
27 June 1986 Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305403
27 March 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305121
28 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977636
13 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972426
6 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964657
21 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273143
16 January 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970569

Deficiency record · 50

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2022 Resolved
Noted fuel leaking from supply piping/hose at the tank connection. Repair piping system to stop leaks.
Action required: 10 - Deficiency Rectified
Due 22 April 2022
Resolved 22 April 2022
Resolution: Loose fittings tightened, hose replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2019 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arrestors. Flame screens were painted over.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2019
Resolved 10 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2019 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). portable bilge pump suction and discharge were reversed and would not reach lowest point in bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2019
Resolved 10 April 2019
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 February 2012 Resolved
Install proper water light lanyard. Lanyard was about 10 feet long. 46 CFR 180.71(d)(2)
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 27 February 2012
Resolution: Received picture that lanyard has been shortened to approx 5 feet. All sat
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 February 2012 Resolved
Provide lifejackets for each person onboard. Limited to 23 persons until corrected. 46 CFR 180.71
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 27 February 2012
Resolution: Received picture of 10 adult type 1 stenciled lifejackets. May operate in accordance with COI. All sat
Electrical › Electrical Distribution System (service) › Cable
Issued 2 February 2012 Resolved
Secure wiring with metal brackets and chafing gear. 46 CFR 183.340(b)2(4)
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 27 February 2012
Resolution: Received picture that metal brackets with chafing gear has been installed. All sat
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 April 2008 Resolved
Replace waterlight on lifefloat.
Due 23 April 2008
Resolved 7 May 2008
Resolution: Conducted deficiency check on this date. Waterlight was replaced.
Lifesaving › Lifefloat › Float-free Link
Issued 16 April 2008 Resolved
Provide proper installation of painter and weak link or research rafting both life floats onto one weight appropriate weak link.
Due 23 April 2008
Resolved 7 May 2008
Resolution: Conducted deficiency check on this date. Lifefloats were secured satisfactorily with independent painter/weak link apparatuses.
Engineering › Steering Gear System › Rudder Stock
Issued 13 July 2006 Resolved
Aft side of port rudder tube approx 3" below packing gland pitted. Grind and weld.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2006
Resolved 13 July 2006
Resolution: Ground out and welded corroded area.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 July 2006 Resolved
Total of 4 approx 1/2" threaded holes located in fwd engine room bulkhead, 3 ft outboard of centerline, two on each side port and stbd. Plugs holes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 July 2006
Resolved 13 July 2006
Resolution: Installed plugs.
Lifesaving › Rigid Liferafts › Markings
Issued 17 July 2003 Resolved
The life floats were not properly marked with passenger capacity.
Due 18 July 2003
Resolved 17 July 2003
Lifesaving
Issued 11 March 1999 Resolved
Found class A 121mhz EPIRB in use. Replace existing EPIRB with CAT I 406 mhz EPIRB in accordance with 46 CFR 180.64 prior to traveling more than 3nmfrom shore while carrying passengers.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Fire Fighting
Issued 11 March 1999 Resolved
Belt driven attached fire pump leaked in engineroom and did not provide pressure to hose. Demonstrate proper operation of power driven fire pump.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Navigation
Issued 6 March 1996 Resolved
PROPERLY SECURE OVERHEAD STEERING CABLES IN LAZARETTE/STEERING VOID.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 6 March 1996 Resolved
INSTALL BULB IN PORT FIXTURE AND INSTALL TWO PROTECTIVE LENSES FOR BOTH OVERHEAD LIGHTING FIXTURES IN FORWARD ELECTRICAL VOID.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Accommodation/Occupational Safety
Issued 18 August 1994 Resolved
ON 18AUG94, THE MASTER, PAUL POLLO, OF THE MOTOR VESSEL HAPAI OWNED BY P & R WATER TAXI, A U.S. DOCUMENTED OCEANGOING SHIP GREATER THAN 40 FEET IN LENGTH, WAS NOT MAINTING A WRITTEN RECORD OF GARBAGE DISCHARGE OR DISPOSAL OPERATIONS.
Condition: Unknown
Due 18 August 1994
Resolved 19 August 1994
Construction/Loadline
Issued 17 March 1994 Resolved
PROVIDE SUCTION STRAINER FOR PORTABLE BILGE PUMP IAW 46 CFR 182.25-5.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Navigation
Issued 17 March 1994 Resolved
PROVIDE CURRENT NAVIGATION CHARTS.
Condition: Unknown
Due 17 March 1994
Resolved 17 March 1994
Documentation
Issued 17 March 1994 Resolved
PROVIDE PROOF OF VALID FCC OPERATORS LICENSE.
Condition: Unknown
Due 17 March 1994
Resolved 17 March 1994
Construction/Loadline
Issued 17 March 1994 Resolved
PROVE PROPER OPERATION OF VESSEL BILGE PUMPS. VESSEL IS PROHIBITED FROM CARRYING PASSENGERS UNTIL OPERATION OF THE BILGE SYSTEM IS PROVED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Accommodation/Occupational Safety
Issued 17 March 1994 Resolved
INSTALL A SAFETY RAIL FOR ELECTRIC COOKING EQUIPMENT (TWO BURNER RANGE) IAW46 CFR 183.10-45(B)(3). COOKING EQUIPMENT IS NOT TO BE USED UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 17 March 1994
Resolved 17 March 1994
Navigation
Issued 12 January 1994 Resolved
PRIOR TO CARRYING PASSENGER FOR HIRE, PROVE PROPER OPERATION OF THE VESSELSSTEERING SYSTEM AND MAIN ENGINES. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 January 1994
Resolved 18 January 1994
Documentation
Issued 24 March 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 24 March 1993 Resolved
Cap all of the ends to the loose wiring located behind the switchboard on the bridge.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Engineering
Issued 24 March 1993 Resolved
Install heat shields on the port and starboard Racor filters located in themachinery space.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 31 March 1992 Resolved
PROVIDE GUARD FOR BELT AND PULLEY SYSTEM OF RAW WATER PUMP ON DIESEL GENERATOR.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Engineering
Issued 31 March 1992 Resolved
PROVIDE GUARD FOR BELT AND PULLEY SYSTEM OF BILGE/FIRE PUMP ON STARBOARD PROPULSION ENGINE.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Electrical
Issued 31 March 1992 Resolved
SUBMIT NEW ELECTRICAL DIAGRAM TO MSO HONOLULU FOR APPROVAL
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Lifesaving
Issued 31 March 1992 Resolved
PROVIDE BATTERY FOR EPIRB.
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Documentation
Issued 31 March 1992 Resolved
PROVIDE SAFETY RADIOTELEPHONY CERTIFICATE WITH VESSEL NAME CHANGE.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Fire Fighting
Issued 31 March 1992 Resolved
PROVIDE ON BOARD OPERABLE HAND FIRE PUMP.
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Engineering
Issued 20 December 1990 Resolved
REPAIR EXHAUST LEAKING ON BOTH PORT & STBD MDE EXHAUST PIPING_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Accommodation/Occupational Safety
Issued 20 December 1990 Resolved
REPAIR BOTH PORT & STBD ENGINE ROOM VENT COVERS AND PROVE ITS OPERATION
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Accommodation/Occupational Safety
Issued 20 December 1990 Resolved
INSTALL INSECT SCREENING TO FRESH WATER VENT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Lifesaving
Issued 20 December 1990 Resolved
REPAIR OR REPLACE EPIRB
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Unknown
Issued 20 December 1990 Resolved
REPLACE 18 LIGHTS TO 18 PFD'S
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Engineering
Issued 20 December 1990 Resolved
RELAG BOTH MDE EXHAUST PIPING FWD OF COOLING INJECTION.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Electrical
Issued 20 December 1990 Resolved
CLEAN AND REFASTEN ACC BATTERY TERMINALS
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Electrical
Issued 20 December 1990 Resolved
REMOVE ROMEX WIRING TO BILGE PUMP AND INSTALL MARINE GRADE WIRING_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Construction/Loadline
Issued 20 December 1990 Resolved
REWELD BULKWARK ON PORT BOW IN WAY OF VESSELS NAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Lifesaving
Issued 20 December 1990 Resolved
PROVIDE COAST GUARD APPROVED FLOAT FREELINK FOR LIFEFLOAT.
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Lifesaving
Issued 14 December 1989 Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Lifesaving
Issued 14 December 1989 Resolved
RENEW 1 APFD WATERTIGHT BATTERY.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Construction/Loadline
Issued 15 July 1988 Resolved
INSTALL CAPTIVE CHAINS TO BOTH WEATHER DECK HATCHES PRIOR TO VESSEL OPERATIONS.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Documentation
Issued 15 July 1988 Resolved
CONDUCT STABILIITY TEST IN THE PRESENCE OF A CG MARINE INSPECTOR. DO NOT OPERATE VESSEL BEYOND 50 NAUTICAL MILES FROM SHORE UNTIL THIS STABILITY TEST IS COMPLETED TO THE SATISFACTION OF THE [name withheld], AL.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Documentation
Issued 27 July 1987 Resolved
REDOCUMENT VESSEL TO COASTWISE REGISTRY OR SURRENDER CERTIFICATE OF INSPEC-TION.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Construction/Loadline
Issued 27 March 1986 Resolved
REPAIR THE CRACKED TACK WELD ON THE TRANSVERSE FRAME UNDER THE PASSENGER AREA.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Documentation
Issued 27 March 1986 Resolved
PROVIDE THE VESSSEL WITH A CURRENT CERTIFICATE OF DOCUMENTATION SHOWING THE CHANGE OF VESSEL NAME AND OWNERSHIP.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Documentation
Issued 27 March 1986 Resolved
PROVIDE THE VESSEL WITH A CURRENT FCC RADIO STATION LICENCE.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Engineering
Issued 27 March 1986 Resolved
REMOVE OR REPAIR THE INOPERATIVE MAIN ENGINE RPM GAUGES ON THE BRIDGE CONSOLE.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986

Ownership record