Records from 2016 to 2024. Most recent: inspection, 2 May 2024.
Inspection history · 22
2 May 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7901882
24 January 2024
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7853599
10 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7764904
22 February 2023
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7640487
20 February 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7643817
20 February 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7658450
15 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7533908
9 February 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7393056
24 December 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7391896
17 August 2021
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7288250
30 April 2021
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7246947
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108513
14 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6953004
30 April 2020
Administrative Inspection · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6946042
1 November 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6886974
16 May 2019
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6685402
5 April 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6386377
26 March 2018
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6378839
1 March 2018
Administrative Inspection · Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6364304
1 August 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6228698
18 May 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5880421
10 May 2016
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5874278
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 2 May 2024
Resolved
No MF radio installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 May 2024
Resolution: MF radio installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 May 2024
Resolved
Amp meter not working for gen set.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 May 2024
Resolution: Meter replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessels shaft was leaking excessively requiring shaft packing.
46 CFR 182.200 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2023
Resolved 16 August 2023
Resolution: Provided video of shaft seals. Shafts are water Lubricated/cool and will leak slgihly while not u/w.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 August 2023
Resolved
An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600); (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system; (3) Contain an independent power source; and (4) Alarm on low power. Vessel did not have interconnect fire detection.
46 CFR 181.450 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2023
Resolved 3 May 2024
Resolution: System installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires and exposed receptacle box in FWD engine bulkhead. Replace/remove
46 CFR 183.200 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2023
Resolved 16 August 2023
Resolution: Provided pictures of correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 August 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. STBD exhaust pipe missing lagging.
46 CFR 177.970
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2023
Resolved 16 August 2023
Resolution: Provided pictures of correction.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 10 August 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] escape hatch not properly marked on top side in mess deck.
46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2023
Resolved 16 August 2023
Resolution: Provided pictures of correction.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 August 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. STBD generator missing guard.
46 CFR 177.960
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2023
Resolved 16 August 2023
Resolution: Provided pictures of correction.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 February 2023
Resolved
Vessel may be required to be taken out of service due to damage to hull plating or structural members; vessel suffered damage in the starboard side of the forepeak due to colliding with an offshore platform and is to be drydocked to determine extent of damage and necessary repair. Vessel is to conduct repairs to the satisfaction of the attending MI prior to movement and/or return to service.
46 CFR 176.600 (d)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 March 2023
Resolution: Repair complete and all welds liquid dye penetrant tested.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 August 2022
Resolved
Electrical equipment and circuts which are a necessary part of any vital system to safe navigation or the vessel will be given special considereation and shall ve subject to certain additional requirements. Vessel's E-lighting did not automatically actuate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2022
Resolution: Video Evidence
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 15 August 2022
Resolved
Suitable covers, guards, or rails shall be installed in any or all exposed and hazardous places such as gears, machinery, etc. Exhaust lagging worn on starboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 15 August 2022
Resolution: Video Evidence
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 April 2018
Resolved
Bilge Alarm was inoperable on the bridge.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 April 2018
Resolved 5 April 2018
Resolution: Proved correct operation of bilge high level alarm.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 April 2018
Resolved
Remote fuel shutoff was not labeled.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 5 April 2018
Resolution: Emergency fuel shutoff was properly marked.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 5 April 2018
Resolved
Fuel tank sight glass was broken off from the valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 5 April 2018
Resolution: Vessel rep provided evidence of newly installed sight glass.
Engineering › Fuel Oil Service System › Ventilation
Issued 5 April 2018
Resolved
Flame screen of #2 fuel vent was corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 5 April 2018
Resolution: Vessel rep replaced flame sceen.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 August 2017
Resolved
Provide updated charts on vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 2 August 2017
Resolution: Verified that updated charts were placed on the vessel.
Communications › Audible Communications › Horn/Whistle
Issued 1 August 2017
Resolved
Prove operation of the ship's whistle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 2 August 2017
Resolution: Verified proper operation of the ship's whistle.
Engineering › Steering Gear System › Hydraulic Hose
Issued 18 May 2016
Resolved
Secure leaks from hydraulic hoses leading to steering pump switches under bridge console.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 19 May 2016
Resolution: Replaced hydraulic hoses to steering gear under bridge console.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 May 2016
Resolved
Provide adequate guards on rotating machinery on port and starboard generators.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 19 May 2016
Resolution: Machinery guards installed to fully encompass rotating machinery.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 May 2016
Resolved
Install emergency lighting fixture in berthing space on main deck.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 18 May 2016
Resolution: Third party electrician installed emergency light prior to MI departure from vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2016
Resolved
Provide metallic wire supports for electrical wire cables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 18 May 2016
Resolution: Metallic wire supports were installed prior to MI departure from vessel.