MAURY USCG vessel records Sign in
← All vessels

PETRODVORETS

PETRODVORETS is a 1998 tank ship. The Coast Guard has recorded 29 inspections since 1999, most recently in June 2016, along with 5 deficiencies and 6 operational controls.

Records from 1999 to 2016. Most recent: inspection, 19 June 2016.

Built
1998
Last inspected
19 June 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9186596 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
494821
Flag
LIBERIA
—
Maury page id
psix-494821

Inspections, by type

…with no type recorded11
Years with a record 15 calendar years (1999–2016)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it59731 - Convention (Subpart B), Gross Ton
31480 - Convention (Subpart B), Net Ton
123402 - Displacement, Metric Ton
105691 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

19 June 2016 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5909404
7 February 2012 PI Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4239651
7 February 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4240531
4 January 2012 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4218282
17 December 2011 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4208713
16 August 2011 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4117975
16 December 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3911974
10 December 2010 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3908423
12 November 2010 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3885148
12 October 2010 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3865084
13 September 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3849066
4 February 2010 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3672927
5 December 2009 Ballast Water Examination · ISPS II Exam · PII Safety Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3641944
21 February 2009 COE-Dockside
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3416564
16 November 2008 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3364042
9 November 2008 Type not recorded
No type recorded · USCGC BONITO (WPB 87341) · USCG Northeast District (CGD-NE) · Activity 3362263
2 June 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3225473
11 March 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2885675
3 April 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2612555
27 January 2006 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2574839
10 January 2006 COC-TVE Annual · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2563875
4 January 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2268799
3 September 2004 ISPS II Exam · COC-TVE Renew
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2185595
2 September 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1895096
24 August 2002 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1665930
12 May 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 290086
22 May 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 277976
28 March 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 276188
15 June 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 429820

Deficiency record · 5

Engineering › Steering Gear System › Pump
Issued 6 January 2012 Resolved
VSL's #01 steering pump is not operational from bridge, only from steering gear room. Part order will take approx. 30 days. To the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 January 2012
Resolution: RCVD Class report giving VSL a condition to sail until parts can be ordered for #01 Steering Gear pump.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 17 December 2011 Resolved
0735 - Personal Equipment - fire-fighting - Fire-fighting personnel, consisting of at least two persons with fire-fighting equipment shall be immediately available at all times during helocopter operations. The vessel only had one person in fire-fighting equipment when the helocopter landed on the vessel. SOLAS (2009 Consol) II-2/18.8.3
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 December 2011
Resolved 17 December 2011
Resolution: 10 C
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 15 December 2011 Resolved
0611 - Lifeboat Inventory - Cargo Ships shall carry one or more lifeboats complying with the requirements of section 4.6 of the code. The vessel's life boats were found with expired water in the water tanks, expired water packages were found, and no accurate inventory of the remaining water packages was aboard. The remaining water packages were found to be good. SOLAS (2001) III/31.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2011
Resolved 17 December 2011
Resolution: 10 C The vessel changed the water in the water tanks (50 Ltrs), removed the expired water packages and took inventory of the remaining water packages (96 Ltrs). Each lifeboat now has the required 105 Ltrs of water.
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 December 2010 Resolved
Vessel required to be equipped with two independent radar systems. S-Band radar inoperable. 33 CFR 164.37
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 17 December 2010
Resolution: Received tech report stating S-Band radar now operating. See scanned tech report for more info.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 4 November 2010 Resolved
Vessel’s audible alarm out on deck for the overfill alarm (98%) is inoperable. Vessel is allowed to load in the U.S. to 95% but if the vessel wishes to continue to 98% capacity the condition must be followed that the person in charge of the transfer operations is in the cargo control room monitoring loading conditions and is able to hear and see the high (95%) and overfill (98%) alarms .
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 10 December 2010
Resolution: Received class report attesting to proper operation of overfill alarms.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.