Records from 2016 to 2021. Most recent: inspection, 19 May 2021.
Documentation record
Registered dimensions (L × B × D)46.3 ft × 14.0 ft × 4.4 ft
Registered tonnagegross 21 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderF O DEAN BOATYARD · WINGATE, MD, UNITED STATES · built 1977
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSTAMFORD, CT
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
19 May 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7201297
30 October 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7088479
22 June 2020
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6965196
19 October 2019
Type not recorded
No type recorded · Station Eatons Neck · USCG Northeast District (CGD-NE) · Activity 6838284
19 October 2019
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6839513
19 October 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6841472
11 September 2019
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6781374
17 April 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6663290
20 March 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6655219
2 April 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6382933
1 August 2017
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6227517
27 July 2017
In-Service Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6222090
16 May 2017
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6149927
1 February 2017
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6081191
21 June 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5921163
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 June 2020
Resolved
Vessel is required a valid FCC Station license. Vessel could not provide at time of inspection.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 23 June 2020
Resolution: Vessel rep provided emailed picture with current FCC Station license,
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 June 2020
Resolved
MMSI is required to be programmed in VHF radio. It is missing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 23 June 2020
Resolution: Vessel rep emailed picutre with correct MMSI programmed in radio.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 June 2020
Resolved
Vessel is required Employee Assistance Program (EAP) instructions posted visible to crew. EAP placard missing.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2020
Resolved 18 August 2020
Resolution: provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 June 2020
Resolved
Vessel is required to have current proof of enrollment on employees. Current enrollment onboard is outdated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2020
Resolved 23 June 2020
Resolution: Vessel rep emailed document with current enrollment.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 June 2020
Resolved
Life Float is required to have an operational float light. Current light was not in working condition. 705 written because vessel can still operate without LF in warm water. Vessel restricted to warm water ops (due date updated to 10/31/2020 when Cold Water comes into effect).
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 July 2020
Resolved 30 October 2020
Resolution: New Life Float has been installed. The proper marking and equipment have been installed for operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 June 2020
Resolved
Passenger count ashore procedures required. Vessel does not have a plan in place to account for the amount of passenger on charters.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 23 June 2020
Resolution: Vessel rep provided plan for passenger count information ashore.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 June 2020
Resolved
Life Float lifeline holders in good working order. Two holders on outside of float ripped in half. 705 written because vessel can still operate without LF in warm water. Vessel restricted to warm water ops (due date updated to 10/31/2020 when Cold Water comes into effect).
Action required: 705 - Other - as specified
Due 22 July 2020
Resolved 30 October 2020
Resolution: New float corrected this def as lifeline holders are installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 June 2020
Resolved
Life Float required to have working retro tape. Current tape is worn, missing and faded. 705 written because vessel can still operate without LF in warm water. Vessel restricted to warm water ops (due date updated to 10/31/2020 when Cold Water comes into effect).
Action required: 705 - Other - as specified
Due 22 July 2020
Resolved 30 October 2020
Resolution: New Life Float corrected this as retro tape is installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 October 2019
Resolved
Vessel is not authorized to operate as a recreational vessel. Vessel was found operating as a recreational vessel with 19 persons on board. Vessel captain did not hold a license as a master of inspected vessel. Vessel is not to be operated without a master with appropriate credential.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2019
Resolved 19 October 2019
Resolution: Vessel owner provided documentation of a properly credentialed master to conduct vessel operations.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 September 2019
Resolved
Replace upper bearing support for rudder post.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2019
Resolved 19 October 2019
Resolution: Vessel repaired upper bearing support. Performed operation test of rudder and found the operation satifactory.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 March 2017
Resolved
Unable to vessel underway due to low tide. Conduct U/W drills PTCP.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2017
Resolved 6 June 2017
Resolution: Conducted Sea Trials, ALL SAT
Documentation › Certificates/Documents › FCC SSL
Issued 29 March 2017
Resolved
Provide current FCC Station License and Safety certificate on board.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2017
Resolved 6 June 2017
Resolution: Verified current FCC Station License, ALL SAT
Operations/Management › Vessel Activity › Other
Issued 29 March 2017
Resolved
Dry-dock and fastener pull due 30 Apr 2017. Vessel can't operate after this date.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2017
Resolved 6 June 2017
Resolution: Verified Drydock and fastener pull were conducted to the satisfaction of an attending Coast Guard Marine Inspector, ALL SAT