Records from 1981 to 2018. Most recent: inspection, 26 February 2018.
Inspection history · 50
26 February 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6362104
15 February 2017
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6089231
3 December 2015
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5774853
17 November 2015
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5762857
8 February 2012
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4241955
24 November 2010
COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3898087
24 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3702109
30 March 2009
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3443044
10 November 2008
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3360647
10 November 2008
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3362315
4 March 2008
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3158025
1 February 2008
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3140116
24 January 2008
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3135492
11 January 2007
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2854104
9 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2599192
8 March 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2598703
3 January 2006
Examination of Repairs · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2529873
24 October 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772186
5 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 119621
20 October 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 118517
20 October 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 196887
12 October 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406797
8 November 1999
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458691
5 October 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390837
25 September 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368455
2 October 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418027
8 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764734
12 March 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 190669
12 January 1996
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446286
17 November 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428559
28 August 1995
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 759815
22 July 1995
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 190670
6 October 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367188
21 December 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448497
28 October 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395878
20 October 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415775
12 November 1991
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244255
6 November 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218603
12 September 1989
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200518
13 May 1989
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342527
4 November 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204541
8 December 1987
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1002440
7 November 1986
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323771
15 October 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990469
26 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977678
29 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975832
15 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283323
17 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963522
19 January 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971968
19 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274043
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 February 2017
No resolution recorded
Conduct Drills in presence of USCG Marine Inspector, IAW 46CFR131.530,535 Prior to Sail
Action required: 17 - Rectify deficiencies prior to departure
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 15 February 2017
Resolved
Fix E-lighting in engine room, in emergency escape hatch IAW 46CFR131.525 Prior to Sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2017
Resolution: Vessel provided renewed e-lights in engine room.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 15 February 2017
Resolved
Remove all oil in bilge of machinery room IAW 33CFR151.10 Prior to sail and prior to 01MAR17.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2017
Resolved 13 March 2017
Resolution: Vessel removed oil from bilge.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 15 February 2017
Resolved
Replace expired orange smoke distressed signal IAW 46CFR180.68 Prior to sailing on routes beyond Lakes, Bays, and sounds.
Action required: 705 - Other - as specified
Resolved 13 March 2017
Resolution: Vessel provided serviceable distres signals.
Fire Fighting › Fire Pumps › Pressure
Issued 15 February 2017
No resolution recorded
Provide operation of fire monitor and minimum of 4 CG approved life buoys w/15 fathoms of line attached to each IAQ 33CFR143 Prior to operation as stand by vessel.
Action required: 705 - Other - as specified
Communications › Audible Communications › Horn/Whistle
Issued 15 February 2017
Resolved
Provide sat operation of ships horn IAW 33CFR83.33 Prior to Sail
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2017
Resolution: Vessel provided renewed equipment for ship horn, tested sat.
Navigation › Piloting/Steering › Marine Charts
Issued 15 February 2017
No resolution recorded
Provide up to date nav charts IAW 46CFR130.330 Prior to Sail.
Action required: 17 - Rectify deficiencies prior to departure
Documentation › Logs/Records › Logbook (official)
Issued 15 February 2017
No resolution recorded
Provide vessel log for matters that must be logged IAW 46CFR131.620 to the satisfaction of the attending USCG inspector.
Action required: 705 - Other - as specified
Lifesaving › Lifefloat › Retroreflective Material
Issued 15 February 2017
Resolved
Provide retroreflective material of approved type to life float. IAW 46CFR164.018 Prior to Sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2017
Resolution: Vessel provided approved retro-reflective tape to life float.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 17 November 2015
Resolved
Double nut Port and Starboard shaft
Action required: 705 - Other - as specified
Due 17 November 2015
Resolved 17 November 2015
Resolution: Installed double nuts
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 17 November 2015
Resolved
Double clamp MDE water coupling
Action required: 705 - Other - as specified
Due 17 November 2015
Resolved 17 November 2015
Resolution: Double clamps installed
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 17 November 2015
Resolved
Adjust overspeed on Both SSOG's
Action required: 705 - Other - as specified
Due 17 November 2015
Resolved 17 November 2015
Electrical › Electric Generation Source (service) › Generator
Issued 17 November 2015
Resolved
Clean excess oil from Port SSOG
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 3 December 2015
Resolution: All excess oil and dirt cleaned from around generator winding intake and prime mover.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 November 2015
Resolved
Tighten both shaft packing to reduce amount of water in shaft box
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 3 December 2015
Resolution: Both shaft packing's repacked and tightened to reduce the amount of water intrusion around shaft packing's.
Construction/Loadline › Structures › Deck Plating
Issued 24 March 2010
Resolved
Noted machinery space watertight bulkhead on port side aft at ventailation duct work holed/crackes aprox 5 inches long. Crop and renew
Action required: 705 - Other - as specified
Resolved 11 May 2010
Construction/Loadline › Hull › Transverse Frame
Issued 24 March 2010
Resolved
Engine room port side forward watertight bulkhead adjacent to fire pump holed/soft patch. 2 loactions one in fuel tank the other space is a void. Crop and renew
Action required: 705 - Other - as specified
Resolved 11 May 2010
Engineering › Bilge Water Management System › Manifold
Issued 30 March 2009
Resolved
Replace the section of bilge manifold piping the was identified due to wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 31 March 2009
Resolution: Section of bilge manifold piping was replaced and tested.
Engineering › Steering Gear System › Rudder
Issued 10 November 2008
Resolved
Both port and starboard were missing, Replace due to damage.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2008
Resolution: Replaced both rudders with new posts.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 February 2008
Resolved
Install guard on steering chain in overhead of machinery room.
Due 8 February 2008
Resolved 1 February 2008
Resolution: Guard installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 1 February 2008
Resolved
Replace frayed cables on fire pump, port generator and water heater.
Due 8 February 2008
Resolved 1 February 2008
Resolution: Cables renewed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2008
Resolved
Tighten all loose compression fittings on various pieces of equipment in E/R.
Due 8 February 2008
Resolved 1 February 2008
Resolution: All compression fittings tightened.
Engineering › Bilge Water Management System › Manifold
Issued 1 February 2008
Resolved
Bilge valves not labled. Lable all bilge valves at manifold.
Due 8 February 2008
Resolved 1 February 2008
Resolution: Bilge valves labled.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 1 February 2008
Resolved
Ventilation closures are not sealing at all. Ensure vents seal.
Due 8 February 2008
Resolved 1 February 2008
Resolution: Vents modified and seal now.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 February 2008
Resolved
Vessel does not have a Navtex reciever onboard. Vessel's route is limited to 100 NM from land until installation has been confirmed and inspected.
Action required: 705 - Other - as specified
Resolved 3 March 2008
Resolution: Navtex Receiver installed on board vessel.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 January 2007
Resolved
Vessel to maintain better lifesaving equipment records.
Action required: 705 - Other - as specified
Resolved 11 January 2007
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 11 January 2007
Resolved
Label all bilge valves as to the compartment they protect.
Action required: 705 - Other - as specified
Resolved 11 January 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 11 January 2007
Resolved
Vessel to demonstrate proper abandon ship drill.
Action required: 705 - Other - as specified
Resolved 11 January 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 January 2007
Resolved
Vessel to demonstrate proper man overboard drill.
Action required: 705 - Other - as specified
Resolved 11 January 2007
Operations/Management › Drills/Instruction › Fire
Issued 11 January 2007
Resolved
Vessel to demonstrate proper fire drill.
Action required: 705 - Other - as specified
Resolved 11 January 2007
Fire Fighting › Means of Escape › Number
Issued 11 January 2007
Resolved
Label emergency escape in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2007
Engineering › Fuel Oil Service System › Vent Pipe
Issued 11 January 2007
Resolved
Provide immediate means of closure for all oil tank vents.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2007
Resolved
Install junction box for stern light and aft deck lights electrical wiring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2007
Communications › Radio Communications › EPIRB
Issued 11 January 2007
Resolved
Renew EPIRB hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2007
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 January 2007
Resolved
Renew rescue harness and lanyard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2007
Resolved
Install proper vertical filament light bulbs in all navigation lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 January 2007
Resolved
Vessel master [name withheld] (lic #1111075), to ensure all drills (Man overboard, fire and abandon ship) are satisfactorily completed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 March 2006
Resolved
Provide proper operation of nav. lights. Vessel limited to daytime operations.
Action required: 705 - Other - as specified
Due 8 April 2006
Resolved 9 March 2006
Navigation › Piloting/Steering › Marine Charts
Issued 8 March 2006
Resolved
Provide up-to-date nav. charts.
Action required: 705 - Other - as specified
Due 8 April 2006
Resolved 9 March 2006
Engineering › Bilge Water Management System › Pump
Issued 8 March 2006
Resolved
Provide proper operation of bilge pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2006
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 March 2006
Resolved
Vessel operated without full compliment of crew.
Due 8 May 2006
Resolved 16 March 2006
Resolution: NOV paid