MAURY USCG vessel records Sign in
← All vessels

MT. MITCHELL

MT. MITCHELL is a 1967 research vessel. The Coast Guard has recorded 34 inspections since 2001, most recently in February 2016, along with 62 deficiencies — 1 with no resolution recorded —, 3 operational controls, 1 with no removal date recorded and 2 casualty investigations in 2006.

Records from 2001 to 2016. Most recent: operational control imposed, 24 February 2016.

Built
1967
Last inspected
24 February 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

6710932 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA9674
495113
Flag
UNITED STATES
369190000
Maury page id
psix-495113

Inspections, by type

…with no type recorded11
Years with a record 12 calendar years (2001–2016)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1591 - Regulatory (Subpart C or D), Gross Ton
588 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA9674MMSI 369190000 · active · compulsorily equipped · granted 24 August 2022, expires 3 September 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

24 February 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5821259
28 August 2015 MARPOL Annex I Examination · Administrative Inspection · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5228975
26 June 2014 MTSA/ISPS Verification · COI Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4898583
2 July 2012 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4365081
15 June 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4344983
12 November 2010 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3889079
25 October 2010 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3877921
26 March 2010 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3714790
9 July 2009 COI Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3511107
12 November 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3361562
28 August 2008 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3311113
3 April 2008 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3176772
25 January 2008 Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3136314
8 August 2006 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2740338
13 June 2006 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2709398
28 February 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2594277
28 February 2006 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2602488
7 February 2006 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2581598
24 October 2005 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2521798
3 October 2005 Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2507441
27 September 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2503259
26 September 2005 MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2501505
14 September 2005 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2492565
3 September 2005 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2492511
17 August 2005 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2467443
19 July 2005 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2432565
2 March 2005 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2313628
2 November 2004 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2233359
22 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2226188
29 July 2004 MTSA/ISPS Verification · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2140446
28 July 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2153512
26 July 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2145509
29 January 2002 Internal Structural Exam · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1482201
17 October 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1073931

Deficiency record · 62

Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 24 February 2016 No resolution recorded
Vessel's company has not completed their class audit for Document of Compliance. Audit must be completed before SMC will be current and valid.
Action required: 705 - Other - as specified
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 September 2015 Resolved
Perform fire, lifesaving/abandoned ship and security drills to the satisfaction of attending marine inspector.
Due 8 September 2015
Resolved 8 September 2015
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 September 2015 Resolved
Provide proof of required drug and alcohol testing for vessel's crew.
Due 8 September 2015
Resolved 8 September 2015
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 September 2015 Resolved
Provide non tank vessel response plan approval letter.
Due 8 September 2015
Resolved 8 September 2015
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 July 2014 Resolved
Power panel EP105 has holes in tops and sides. Breaker openings missing blanks.
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 1 September 2015
Engineering › Fuel Oil Service System › Hose
Issued 14 July 2014 Resolved
Provide fire resistence sleeve for all fuel hoses as required to meet SAE J-1942.
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 1 September 2015
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 14 July 2014 Resolved
Provide periodic safety test procedures as required.
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 15 September 2015
Electrical › Electric Supply System (service) › Cable
Issued 14 July 2014 Resolved
Properly terminate all dead end wiring to old emergency fire and bilge pumps.
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 1 September 2015
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 July 2014 Resolved
CPP hose to duplex filters has incorrect fitting (hose clamp). Replace with proper fitting.
Action required: 705 - Other - as specified
Due 14 September 2014
Resolved 1 September 2015
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 1 November 2010 Resolved
Owner operator did not ensure credit Drydock Inspection and Internal Structural Examination were completed within required timeframes. Prior to returning to certificated service a credit Drydock Inspection and Internal Structural Examination shall be completed to the satisfaction of the OCMI.
Action required: 705 - Other - as specified
Resolved 12 November 2010
Resolution: Credit Drydock Inspection and Internal Structural Examination completed with 00 deficiencies issued or outstanding. See MISLE Activity # 3889079 for details.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 28 August 2008 Resolved
Waste recepticals were not constructed of non-combustible materials.
Action required: 705 - Other - as specified
Resolved 29 August 2008
Resolution: Waste Recepticals ordered and plastic waste recepticals were removed.
Accommodation/Occupational Safety › Ventilation › General
Issued 28 August 2008 Resolved
Vents on the aft deck going the Electric Stores, Bow Thruster and Supply Stores were frozen.
Action required: 705 - Other - as specified
Resolved 29 August 2008
Resolution: Items were identified and corrected during the inspection.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 August 2008 Resolved
An emergency light was broken by the Galley Stores (D-08-101)
Action required: 705 - Other - as specified
Resolved 29 August 2008
Resolution: The light was repaired during the inspection.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 25 January 2008 Resolved
33 C.F.R. 151.28(a) -(e) Owner/ Operator is required to submit annual review to U.S. Coast Guard VRP Program, COMDT, (CG-5431).
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 4 April 2008
Resolution: The vessel''s SOPEP was approved on 04/04/2008.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 24 April 2007 Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(5)(D)(ii)-The NTVRP does not identify a qualified individual by name.
Due 24 May 2007
Resolved 13 January 2009
Resolution: NTVRP #05055 approved 1/13/09 with revision received 12/19/08. Interim Operating Authorization for the MT. MITCHELL expires 1/13/2011.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 24 April 2007 Resolved
33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization (OSRO) or provide an OSRO contract for the remote Guam COTP zone. 33U.S.C.1321(j)(5)(D)(i)-There is a vessel name inconsistency between the plan and MISLE. (plan lists vsl as MT MITCHELL--no period)
Due 24 May 2007
Resolved 13 January 2009
Resolution: NTVRP #05055 approved 1/13/09 with revision received 12/19/08. Interim Operating Authorization for the MT. MITCHELL expires 1/13/2011.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 August 2006 Resolved
Globe and guard missing on light fixture in fwd storage space.
Condition: Unknown
Due 8 August 2006
Resolved 8 August 2006
Resolution: Installed globe and guard.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 October 2005 Resolved
Conduct crew drills in the presents of a USCG Marine Inspector prior to getting underway.
Condition: Unknown
Due 30 April 2006
Resolved 7 February 2006
Resolution: Witnessed sat crew drills.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 24 October 2005 Resolved
Complete ISM annual and ISM and DOC endorsement by ABS prior to sailing.
Condition: Unknown
Due 30 April 2006
Resolved 7 February 2006
Resolution: Cleared.
Construction/Loadline › Hull › Side Shell
Issued 17 August 2005 Resolved
C/R stbd sideshell IWO frame #52 IVO E/R fwd bulkhead & above space deck @ next hull exam (NLT 31Oct05). Repair to be completed IAW ABS rules or NVIC 7-68 to satisfaction of U.S. Coast Guard Marine Inspector or Recognized Classification Organization.
Condition: Damaged By Earlier Event
Due 31 October 2005
Resolved 3 October 2005
Resolution: Cleared.
Engineering › Pressure Vessel › Pressure Gauge
Issued 29 July 2004 Resolved
Calibrate all oil/air pressure guages throughout vessel to ensure accurate reading.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 July 2004 Resolved
Implement and maintain an engineering maintenance program.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Engineering › Bilge Water Management System › Not Operational
Issued 29 July 2004 Resolved
Verify operation of all remote bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Engineering › Steering Gear System › Power Unit
Issued 29 July 2004 Resolved
Ensure that audible/visual failure alarms for steering pump can be heard/seen from bridge.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 July 2004 Resolved
Make safe any/all loose electrical wires/junction boxes
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 29 July 2004 Resolved
Provide copies of ABS documents (classification document & safety construction certificate)
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 July 2004 Resolved
Stow/secure loose boxes/equipment throughout entire vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Stability › Watertight Integrity › General
Issued 29 July 2004 Resolved
Demonstrate manual operation (open/close) of watertight doors.
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 29 July 2004 Resolved
Provide updated manouvering fact sheet & post on bridge.
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 July 2004 Resolved
Replace in kind all expired eyewash bottles throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Engineering › Bilge Water Management System › Not Operational
Issued 29 July 2004 Resolved
Provide dedicated manned watch to accurately log bilge levels in all bilge spaces.
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 November 2004
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 10 August 2003 Resolved
Provide required life jackets when vessel is fully crewed.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 29 January 2002 Resolved
Prove proper operation of elevator machinery space thermal detecter.
Action required: 705 - Other - as specified
Resolved 29 January 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 29 January 2002 Resolved
Prove proper operation ofpaint locker pressure switch for ventilation cut out.
Action required: 705 - Other - as specified
Resolved 29 January 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 29 January 2002 Resolved
Provide suitable time delay devices in spaces protected by fixed CO2 systems without horizontal escape.
Action required: 705 - Other - as specified
Resolved 29 January 2002
Fire Fighting › Fire Main
Issued 29 January 2002 Resolved
In presence of marine inspector, hydrostatically test new piping and welds in fire main IWO fire pump.
Action required: 705 - Other - as specified
Resolved 6 August 2003
Fire Fighting › Fire Pumps
Issued 29 January 2002 Resolved
Prove proper operation of main fire pump. Pitot water gauge pressure shows 30 psi vice 50 psi @ hose. LEGACY COMPONENT DESC: Pressure
Action required: 705 - Other - as specified
Resolved 6 June 2003
Construction/Loadline › Structures
Issued 29 January 2002 Resolved
Prove proper operation of doors listed on 30MAY03 work list (12 total) LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Resolved 19 June 2003
Construction/Loadline › Structures
Issued 29 January 2002 Resolved
Prove properation of all interior doors listed in worklist dtd 6JUN03 (includes both sliding water tight doors) LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Resolved 19 June 2003
Fire Fighting › Fire Hydrants
Issued 29 January 2002 Resolved
Incorrect spanner wrenches, unable to remove hoses, replace with proper wrenches. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Resolved 6 August 2003
Documentation › Certificates/Documents › Stability Letter
Issued 29 January 2002 Resolved
Provide stability letter, trim & stability book, and loading manual.
Action required: 705 - Other - as specified
Resolved 29 July 2004
Documentation › Logs/Records › Logbook (official)
Issued 29 January 2002 Resolved
Complete lifesaving maintenance record and SOLAS training manual.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Resolution: corrected
Navigation › Piloting/Steering
Issued 29 January 2002 Resolved
Provide current charts LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Resolved 29 July 2003
Navigation › Piloting/Steering › Compass Deviation Table
Issued 29 January 2002 Resolved
Provide table and illumation for magnetic compass.
Action required: 705 - Other - as specified
Resolved 29 July 2004
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 29 January 2002 Resolved
Calibrate speed/distance log.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Navigation › Piloting/Steering › Chronometer
Issued 29 January 2002 Resolved
Provide shaft tachometer on bridge.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Communications › Internal Communications System › Engine Order Telegraph System
Issued 29 January 2002 Resolved
Provide Engine Order Telegraph.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 29 January 2002 Resolved
Provide maneuvering info sheet.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Communications › Alarms/Indicators
Issued 29 January 2002 Resolved
Prove proper operation of all general alarm bells operating form bridge and engine room contact makers. LEGACY COMPONENT DESC: General Alarm
Action required: 705 - Other - as specified
Resolved 31 July 2003
Resolution: Tested all enunciators from bridge and engine room. All sat.
Operations/Management › Lifesaving
Issued 29 January 2002 Resolved
Post placard of lifesaving signals.
Action required: 705 - Other - as specified
Resolved 24 June 2003
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 January 2002 Resolved
Provide station bill
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 29 January 2002 Resolved
Provide approved plans.
Action required: 705 - Other - as specified
Resolved 29 January 2002
Fire Fighting › Fixed Fire Detection System › Approval
Issued 29 January 2002 Resolved
Provide approved plans.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Operations/Management › Pollution › Reporting Discharge of Hazardous Substance
Issued 29 January 2002 Resolved
Provide COFR.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 January 2002 Resolved
Provide class documents.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Documentation › Certificates/Documents › International Load Line Certificate
Issued 29 January 2002 Resolved
Provide Loadline Certificate.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 29 January 2002 Resolved
Provide Tonnage Certificate.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 29 January 2002 Resolved
Provide Safety Manegement Certificate.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 29 January 2002 Resolved
Provide Document of Compliance.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Communications › Internal Communications System › Engine Order Telegraph System
Issued 29 January 2002 Resolved
Prove proper operation of PA system, both inside and outside of vessel.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004
Fire Fighting › Fire Hydrants
Issued 29 January 2002 Resolved
Prove proper operation of #17 and higher.
Action required: 705 - Other - as specified
Resolved 24 June 2003
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 January 2002 Resolved
Prove proper operation of alarm for 15ppm and higher.
Action required: 705 - Other - as specified
Due 2 November 2004
Resolved 2 November 2004

Casualty record · 2

28 February 2006Routine · role: Involved in a Marine Casualty · activity 2594277
13 June 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2709398
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record