MAURY USCG vessel records
← All vessels

MARY B III

MARY B III is a 1978 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in February 2026, along with 37 deficiencies and 2 casualty investigations between 2011 and 2012.

Records from 2011 to 2026. Most recent: inspection, 26 February 2026.

Built
1978
Last inspected
26 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 February 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCZ3255
Flag
UNITED STATES
Maury page id
psix-49513

Documentation record

Registered dimensions (L × B × D)48.1 ft × 18.0 ft × 7.6 ft
Registered tonnagegross 53 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMAGE & STEVENS SHIPBLDR · EAST BOOTHBAY ME, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 20 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Regulatory (Subpart C or D), Gross Ton
36 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

26 February 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8317078
27 February 2025 Internal Structural Exam · Examination of Repairs · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8085540
26 February 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8084858
22 February 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7868097
4 December 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7833135
26 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7724485
6 March 2023 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7645939
28 March 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7416663
21 June 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7231320
3 February 2021 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7136210
19 October 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7080883
30 March 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6933320
14 May 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6682742
12 February 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6623482
29 May 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6427476
13 March 2017 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6104057
2 March 2017 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6095486
9 May 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5872222

Deficiency record · 37

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2026 Resolved
The individual bilge suction lines shall be led to a central control point or manifold. Each line shall be pro-vided with a stop valve at the control point or manifold and in addition shall be provided with a check valve at some accessible point in the bilge line. Vessel's fire main back flooded into engine room compartment through bilge check valve. Repair to satisfaction of CG Marine Inspector. 46 CFR 182.25-5(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2026
Resolved 26 February 2026
Resolution: Valves rebuilt, fire and bilge suction tested satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2026 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol test strips were expired. 46 CFR 4.06-15(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026
Resolved 23 March 2026
Resolution: Test Strips Purchased.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 February 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel did not have charts for operating area. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026
Resolved 23 March 2026
Resolution: Charts provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 February 2026 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Multiple life jackets were found to have unapproved or degraded SOLAS approved retroreflective tape. 46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026
Resolved 23 March 2026
Resolution: Approved retroreflective tape applied.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2026 Resolved
If a pipe, scupper, or electrical cable passes through a main transverse watertight bulkhead, the opening through which it passes must be watertight. Multiple bulkhead penetrations identified between Lazarette and tank space without proper watertight integrity. 46 CFR 171.111(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026
Resolved 23 March 2026
Resolution: Penetrations on bulkheads filled with fire proof foam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2026 Resolved
Except as otherwise provided in this paragraph all engines shall be water cooled. Flexible hose between sea chest and port engine suction pipe was unsatisfactory. 46 CFR 182.20-10(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026
Resolved 23 March 2026
Resolution: Hose replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 26 February 2026 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026
Resolved 23 March 2026
Resolution: Guard reattached.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 February 2026 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Light fixture in forward compartment was missing a cover. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2026
Resolved 23 March 2026
Resolution: cover replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 February 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. MIs observed vessels first-aid kit did not contain equivalent contents.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: All required contents were provided in the first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 February 2025 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. MIs observed the release was labeled incorrectly as Jun2025.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: Hydrostatic release unit is correctly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 February 2025 Resolved
The float-free link required by § 180.130(a)(1) must be: Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. MIs observed identification tag was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: Identification tag was provided on the float-free link.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 February 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MIs observed the stern light was non operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: The stern light was replaced and is operational.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 February 2025 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. MIs observed cover to the battery box was unsecured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: Cover to the battery box was secured.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 February 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MIs observed port fire pump fanbelt chaffing on the mounting platform.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: The fanbelt on the mounnting platform to the port fire pump was replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 26 February 2025 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF DSC radiotelephone installation meeting the requirements of 80.1101(c)(2). MIs observed vessel's MMSI number was not displayed on VHF radio. 47CFR80.905(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: Vessel MMSI number is displayed on VHF radio.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2025 Resolved
Gears, couplings, flywheels, and all rotating machinery capable of injuring personnel must be provided with adequate covers or guards. MI's observed both engines missing belt and shaft guards. Replace/ repair to satisfaction of CG inspectors
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: Vessel repaired and replaced engine belt and shaft guards.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 26 February 2025 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI's observed open bulkhead penetration on Engine room bulkhead. Replace/ repair to satisfaction of CG inspectors
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: Open bulkhead penetration on engine room bulkhead was repaired and closed off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2025 Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion. Where passing through bulkheads, fuel lines must be protected by close fitting ferrules or stuffing boxes. All fuel lines and fittings must be accessible for inspection. MI's observed fuel lines ineffectively secured to one another on PORT MDE, high potential for movement and chaffing. MI's observed fuel lines on cylinder #3 on STBD MDE, to be ineffectively secured. Repair to the satisfaction of CG inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: fuel lines on cylinder #3 on STBD MDE were repaired and effectively secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 February 2025 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. MI's observed negative terminal on STBD battery loose and not secured properly. Repair to the satisfaction of CG inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 14 March 2025
Resolution: Negative terminal on STBD battery was repaired and secured properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2023 Resolved
46 CFR 182.25-1: All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments. Bilge pump system would not de-water multiple spaces filled with water. Bilge pump piping arrangement is leaking in multiple places and flooding the engine room. Repair/replace to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2023
Resolved 29 June 2023
Resolution: Bilge pumps manifold and piping tested fully operational. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 June 2023 Resolved
46 CFR 176.25-5: Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weatherdeck. Forward compartment welds were leaking water into adjacent compartment. Repair weld and complete NDT test.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2023
Resolved 29 June 2023
Resolution: Weld repaired, tested, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 June 2023 Resolved
46 CFR 183.420: All vessels must have navigaion lights. Starboard running light is out, repair/replace to the satisfaction of Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2023
Resolved 29 June 2023
Resolution: Starboard navigation light replaced, all sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 June 2023 Resolved
46 CFR 182.610: A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Tie rod bushings are worn and rusted. Steering chain is chafing on framing. Repair/replace to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 5 September 2023
Resolution: Received pictures of the rebuilt steering system, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 June 2023 Resolved
46 CFR 177.100: The construction and arrangement of a vessel must allow the safe operation of the vessel. Through hull connections in the tank room disconnected. Multiple blkhd openings between frames. Replace hoses and cap off all openings.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2023
Resolved 29 June 2023
Resolution: All hoses replaced and closed off. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2023 Resolved
46 CFR 176.25-10 (6): Sea valves and bulkhead closure valves. All overboard discharge and intake valves shall be checked. Sewage tank overboard discharge is leaking and causing pitting and rust build-up in tank room. Replace/repair valve/packing to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 29 June 2023
Resolution: Discharge valve replaced/tested, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 October 2020 Resolved
Repair bilge alarm indicating panel. 46CFR183.01-10
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2020
Resolved 26 October 2020
Resolution: New alarm pnl installed and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 October 2020 Resolved
Repair cracked surface on lifefloat and ensure oars are properly labeled with vessel name. 46CFR180.15-1 46CFR180.10-2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2020
Resolved 26 October 2020
Resolution: Cracks on lifefloat surface repaired and oars properly labeled.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2020 Resolved
Renew FCC Radiotelephone Certificate. 47CFR80.903
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 October 2020
Resolved 26 October 2020
Resolution: Certificate renewed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 October 2020
Resolved 26 October 2020
Resolution: License renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2019 Resolved
Bilge alarms at the console were not working properly. Audible and visual alarms not working for two holds. The issue was a wiring problem. The electrical wiring was fixed on the spot and all alarms worked as intended. Deficiency cleared.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2019
Resolution: wiring for alarms was fixed prior to the conclusion of the inspection. Def cleared on the spot.
Electrical › Electric Supply System (service) › Cable
Issued 20 March 2017 Resolved
Use metal supports for cables located above the STBD Engine. 46CFR183.340
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 4 April 2017
Lifesaving › Lifefloat › Markings
Issued 20 March 2017 Resolved
Re-stencil the vessel name on both life floats. 46CFR185.604
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 4 April 2017
Engineering › Steering Gear System › Interlock
Issued 2 March 2017 Resolved
Replace in kind bracket (on starboard side) and steering bar. 46CFR176.814
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2017
Resolved 6 March 2017
Resolution: Bracket and steering bar replaced and repaired satisfactorily.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 2 March 2017 Resolved
Cutlass bearing must be replaced on both shafts. 46CFR176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2017
Resolved 6 March 2017
Resolution: Cutlass bearings appropriately replaced.
Stability › Watertight Integrity › General
Issued 2 March 2017 Resolved
Crop and renew section on the starboard side of the hull, around the area of the tank room (approximately 18” X 22”). 46CFR177.300(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2017
Resolved 6 March 2017
Resolution: Hull repair on starboard side of vessel completed satisfactorily.
Construction/Loadline › Structures › Door
Issued 9 May 2016 Resolved
Watertight door leading to engine room not properly marked "WATERTIGHT DOOR - KEEP CLOSED" on both sides of door. 46 CRF 185.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 19 May 2016
Resolution: Door leading to engine room wasproperly marked "WATERTIGHT DOOR - KEEP CLOSED" on both sides of door.
Construction/Loadline › Structures › Scuttle
Issued 9 May 2016 Resolved
Emergency hatch leading from the engine room not properly marked "EMERGENCY EXIT - KEEP CLEAR" on both sides. 46CRF185.606
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 19 May 2016
Resolution: Emergency hatch leading from the engine room was properly marked "EMERGENCY EXIT - KEEP CLEAR" on both sides.

Casualty record · 2

20 April 2011Routine · role: Involved in a Marine Casualty · activity 4009360
8 June 2012Routine · role: Involved in a Marine Casualty · activity 4342617
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.