Records from 2016 to 2026. Most recent: inspection, 28 April 2026.
Documentation record
Registered dimensions (L × B × D)47.5 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 38 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDEPOE BAY, OR
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 27 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
28 April 2026
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8358684
16 October 2025
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8254634
7 May 2025
Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8131915
13 June 2024
DAPI Audit · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7934784
10 May 2024
Examination of Repairs · Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7939553
27 February 2024
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7872442
10 May 2023
Simplified Stability Test · COI Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7685173
21 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611920
7 June 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7470841
15 February 2022
Deficiency Check · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7395025
6 April 2021
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7167209
9 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939667
2 April 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6934643
12 February 2020
Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6907949
6 May 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6676428
16 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6415496
22 February 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6358203
16 May 2017
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6147970
6 May 2016
DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5868947
11 February 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5813888
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 7 June 2022
Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Protective shielding for valve handles on both fuel shut off valves were severely corroded.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 June 2022
Resolution: Received pictures of corrected protective shielding for the valve handles on the fuel shut-offs.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 15 February 2022
Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. The following needs to be repaired prior to credit drydock 2024:
1. Crack in rail between 1st and 2nd stanchion from bow on port side.
2. Crack in rail between 1st and 2nd stanchion from bow on starboard side.
3. Crack in weld on 1st stanchion from the bow on starboard side.
4. Crack in base of stanchion on starboard side furthest outboard on transom.
5. Crack in firberglass at base of stanchion inboard of stanchion of #4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 10 May 2023
Resolution: Cracks in handrails were repaired by welding. Attending MI inspected and found repairs satisfactory.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 16 May 2017
Resolved
Light Batteries are Expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 May 2017
Resolution: Owner installed new batteries in all life jacket lights.
Electrical › Electrical Distribution System (service) › Conductor
Issued 16 May 2017
Resolved
Lighting circuit with switch, plug, marine cable, junction box, and two lights are installed without plan review in forward compartment. Required Removal of installation. 46 CFR 176.600. New T
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 13 June 2017
Resolution: Circuit was removed.
Engineering › Fuel Oil Service System › Piping
Issued 16 May 2017
Resolved
Flexible Fuel hose is installed with hose clamps from the fuel tank to the Engines and not IAW 46 CFR 182.455. Owner granted until drydock in February to replace fuel hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 6 May 2019
Resolution: Flexible fuel hoses installed IAW 46 CFR 182.455
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2017
Resolved
Exposed wire in fwd bulkhead top starboard side in Lazarette. Wire needs to be removed or the equipment intended for use needs to be connected and maintained. 46 CFR 183.05 Old-T
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 13 June 2017
Resolution: Wires were removed.