Records from 1981 to 2016. Most recent: inspection, 19 January 2016.
Inspection history · 51
19 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6142570
15 September 2015
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5720985
9 October 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5005749
5 July 2012
Annual Inspection · Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4368062
5 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4202209
15 August 2011
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4116266
18 July 2011
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4085850
25 September 2010
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3859782
13 August 2008
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3297612
24 July 2008
Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3285234
29 October 2007
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3088869
31 July 2006
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2731180
22 October 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1694382
19 October 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437970
19 October 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426488
5 January 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811400
5 February 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453451
6 May 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 755029
3 May 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 208566
12 February 1997
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430346
9 February 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409445
14 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 448231
6 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 452433
3 November 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 535096
9 February 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367287
7 October 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 702548
18 June 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 158070
8 February 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447322
31 March 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 57441
16 February 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429713
25 June 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265063
8 May 1992
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 959751
11 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 961130
7 February 1991
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 902970
22 January 1991
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915877
7 November 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913348
8 August 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900707
9 February 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234842
8 February 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1346170
25 August 1988
Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349084
25 July 1988
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1346041
23 July 1988
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035809
28 February 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1029580
5 February 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1331267
5 February 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016213
4 February 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300643
19 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291991
31 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970715
23 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273689
12 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276170
13 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963493
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 September 2015
Resolved
Fly wheels were exposed on each diesel engine, guards required.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 16 September 2015
Resolution: Metal plates were welded onto original guard plate to eliminate exposure of fly wheels.
Engineering › Steering Gear System › Hydraulic Hose
Issued 15 September 2015
Resolved
Connecting elbow for hydraulic hose was rubbing on interior hull brace.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 16 September 2015
Resolution: Fitting was replaced with smaller connecting elbow that allowed room for hydraulic hose to move freely.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 September 2015
Resolved
Emergency light in engine room non-operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 16 September 2015
Resolution: Emergency light in engine room operable.
Engineering › Fuel Oil Service System › Filter
Issued 15 September 2015
Resolved
Required to have metal bowl catchments under fuel oil filters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 16 September 2015
Resolution: Metal bowl catchments were installed.
Operations/Management › Drills/Instruction › Fire
Issued 15 September 2015
Resolved
Unsatisfactory performace of fire drill. Crew was out of practice and uneducated.
Due 16 September 2015
Resolved 16 September 2015
Resolution: Crew performed fire drill to the satidfaction of the CG marine insepector.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 September 2015
Resolved
Unsatisfactory performace of MOB drill. Crew was out of practice and uneducated.
Due 16 September 2015
Resolved 16 September 2015
Resolution: Crew performed MOB drill to the satidfaction of the CG marine insepector.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 15 September 2015
Resolved
Unsatisfactory performace of abandon ship drill. Crew was out of practice and uneducated.
Action required: 705 - Other - as specified
Due 16 September 2015
Resolved 16 September 2015
Resolution: Crew performed abandon ship drill to the satidfaction of the CG marine insepector.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 July 2012
Resolved
Bunk Lights inop
Due 30 August 2012
Resolved 9 August 2012
Deck/Cargo › Cargo Transfer (solid) › General
Issued 5 July 2012
Resolved
Port deck aft spanner wrench wrong style present
Due 30 August 2012
Resolved 9 August 2012
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 July 2012
Resolved
Vsl name worn and missing. Restencil
Due 30 August 2012
Resolved 9 August 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 5 July 2012
Resolved
Loudhailer cable duct taped to deck. Reroute
Due 30 August 2012
Resolved 9 August 2012
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 5 July 2012
Resolved
Circuit Breaker panel cover lcoated near kitchen area has shifted down and now some of the cables are exposed. Refasten breaker panel to protect users from cable hazards.
Due 30 August 2012
Resolved 9 August 2012
Accommodation/Occupational Safety › Ventilation › General
Issued 5 July 2012
Resolved
head fan exhaust blwing into pantry. Fan taped together and is unsafe. Having them remove
Due 30 August 2012
Resolved 9 August 2012
Stability › Watertight Integrity › General
Issued 5 July 2012
Resolved
wire run in forward engine room bulkhead. Wires penetration not watertight. Reseal.
Due 30 August 2012
Resolved 9 August 2012
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 5 July 2012
Resolved
Heat blanket around port side engine exhaust falling off. Having them resecure to exhaust.
Due 30 August 2012
Resolved 9 August 2012
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 5 July 2012
Resolved
Engine room circuit breaker, missing blank in breaker panel. Having them install blank in breaker to protect from shock.
Due 30 August 2012
Resolved 9 August 2012
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 5 July 2012
Resolved
Bell improper size. Having them replace beel with proper diameter.
Due 30 August 2012
Resolved 9 August 2012
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2011
Resolved
Vessel's stability letter information has not been updated to comply with the new assumed average weight per person of 185 pounds as per 46 CFR 178.310(a)(1). The vessel is required to have an updated stability letter. The maximum persons allowed as per the stability letter is reduced to 51 persons.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 January 2012
Resolved 15 August 2012
Resolution: Issued vsl new stability addendum reducing total passenger count from 46 to 43.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 July 2011
Resolved
The vessel does not have a crew member with a valid FCC marine radio operator's permit. The vessel is required to have 1 officer with a valid FCC marine radio operator's permit as per 47CFR80.159.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2011
Resolved 15 August 2011
Resolution: Recievied copies of the marine radio operators permit for the vessel''s captains.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2011
Resolved
The vessel has wiring in the engine room secured with plastic ties. The vessel needs to secure the wiring with metal ties.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 9 August 2012
Documentation › Certificates/Documents › FCC SSL
Issued 24 July 2008
Resolved
Bridge to Bridge Certificate expired
Due 15 August 2008
Resolved 4 August 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 29 October 2007
Resolved
Provide pilothouse engine starts
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 28 July 2008
Construction/Loadline
Issued 23 July 1988
Resolved
MAKE PERMENT REPAIRS TO HOLE IN STBD SIDE OF VESSEL APPROX 7' X 20' AND MAKE REPAIRS TO ELEC. AND STEERING.
Condition: Unknown
Due 16 September 2015
Resolved 16 September 2015