Records from 1982 to 2000. Most recent: inspection, 23 March 2000.
Inspection history · 37
23 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816704
9 February 2000
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046333
26 April 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791093
1 April 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399081
2 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766911
25 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798820
22 August 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 10108
22 August 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 209255
18 May 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470720
7 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793312
22 April 1998
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1456575
2 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122170
24 October 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 89593
24 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115441
20 February 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407839
16 May 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082133
1 February 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435720
5 September 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 164430
2 March 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439592
8 February 1995
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1468341
2 February 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434081
27 March 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447232
19 March 1993
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407126
13 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 947113
28 February 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924443
23 April 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224019
9 March 1990
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916758
10 May 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1202230
26 April 1989
Re-Inspection · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1038731
25 March 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036043
15 June 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324889
3 April 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298660
31 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978679
22 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282589
21 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973430
12 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275134
11 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278434
Lifesaving
Issued 1 April 1999
Resolved
PROVIDE AN APPROVED RESCUE BOAT PER 46 CFR 199.262, 199.175, (SUBCH W) AND 160.156 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Construction/Loadline
Issued 18 May 1998
Resolved
INSTALL AN APPROVED OILY WATER SEPERATOR AS REQUIRED BY 33CFR 155.360
Condition: Unknown
Due 18 May 1998
Resolved 18 May 1998
Documentation
Issued 18 May 1998
Resolved
OBTAIN AND PLACE ON BOARD A VALID INTERNATIONAL OIL POLLUTION PREVENTION _x001C_ CERTIFICATE AS REQUIRED BY 33CFR 151.19.
Condition: Unknown
Due 18 May 1998
Resolved 18 May 1998
Accommodation/Occupational Safety
Issued 1 February 1996
Resolved
REMOVE THE 250 PSI RELIEF VALVES FOR THE DIVE AIR TANK AND INSTALL RELIEF SET AT OR BELOW THE MAWP OF 200 PSI. TANKS ARE NOT TO BE USED UNTIL REPAIRSARE AFFECTED.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Documentation
Issued 1 February 1996
Resolved
PROVIDE ONBOARD AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP).
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Electrical
Issued 1 February 1996
Resolved
INSTALL AN EMERGENCY LIGHT IN THE #213 GENERATOR ROOM.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Electrical
Issued 1 February 1996
Resolved
REPAIR OR REPLACE VOLTMETER AND FREQUENCY METER ON THE MAIN SWITCHBOARD.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Electrical
Issued 9 March 1990
Resolved
PROVE PROPER OPERATION OF SHIP'S SERVICE GENERATORS' OVERSPEED TRIPS, HIGH TEMPERATURE AND LOSS OF LUBE OIL ALARMS. (46 CFR 111.17).
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Electrical
Issued 9 March 1990
Resolved
REPAIR OR REPLACE WASTED EMERGENCY BATTERY BOX ON 01 DECK. (46 CFR 111.15)
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Deck/Cargo
Issued 9 March 1990
Resolved
CONDUCT HYDROSTATIC TEST OF FUEL OIL TRANSFER HOSE TO 1 1/2 MAWP IAW 33 CFR156.170. _x001C_
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Electrical
Issued 9 March 1990
Resolved
PROVE PROPER OPERATION OF CIRCUIT BREAKER TO QUARTERS, GALLEY AND A/C UNITS. CURRENT CIRCUIT BREAKER IS WRONG TYPE.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Unknown
Issued 21 March 1984
Resolved
RENEW THE NONSKID SURFACE OF THE HELOCOPTER DECK.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL DELTA 1 DN590039.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
PROVIDE ONE BV SEMI PORTABLE FIRE EXTINGUISHER AT EACH HELOCOPTER DECK ACCESS.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
INSTALL A FIRE MAIN HYDRANT AT EACH HELO DECK ACCESS EQUIPPED WITH 50 FT. OF 2.5 INCH HOSE AND A COMBINATION NOZZLE, RACK, SPANNER AND FOG APPLICATOR
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
INSTALL A 1.5 METER SAFETY NET AROUND THE HELOCOPTER DECK PERIMETER, NOT MORE THAN 15 CENTIMETERS ABOVE THE HELOCOPTER DECK SURFACE.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
INSTALL RECESSED TIE DOWNS ON THE HELOCOPTER DECK.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
INSTALL A DRAIN CHANNEL AND DROP LINE AROUND THE PERIMITER OF THE HELO- COPTER DECK.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
PAINT AN AIMING CIRCLE ON THE HELOCOPTER DECK.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
MARK THE VESSEL'S NAME ON THE HELOCOPTER DECK.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
PAINT A CONTINUOUS 40 CENTIMETER WIDE LINE OF A CONTRASTING COLOR AROUND THE HELOCOPTER DECK PERIMITER.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
INSTALL ALTERNATING BLUE AND YELLOW LIGHTS AROUND THE HELOCOPTER DECK PER- IMITER.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
INSTALL A WIND DIRECTION INDICATOR ON THE HELOCOPTER DECK.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984
Unknown
Issued 21 March 1984
Resolved
INSTALL AN ADDITIONAL EMERGENCY ESCAPE ROUTE OPPOSITE THE EXISTING ONE ON THE HELOCOPTER DECK.
Condition: Unknown
Due 21 March 1984
Resolved 21 March 1984