MAURY USCG vessel records Sign in
← All vessels

RIVER QUEEN

RIVER QUEEN is a 1978 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1984, most recently in September 2002, along with 103 deficiencies.

Records from 1984 to 2002. Most recent: inspection, 13 September 2002.

Built
1978
Last inspected
13 September 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA7117
Flag
UNITED STATES
366839830 (licence lapsed)
Maury page id
psix-49535

Inspections, by type

…with no type recorded7
Years with a record 18 calendar years (1984–2002)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it85 - Regulatory (Subpart C or D), Net Ton
85 - Regulatory (Subpart C or D), Gross Ton
0 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA7117MMSI 366839830 · expired · compulsorily equipped · granted 21 February 2002, cancelled 28 April 2012
WUU3223MMSI not assigned · expired · compulsorily equipped · granted 22 October 1998, cancelled 10 January 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 43

13 September 2002 COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1660898
2 April 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1600476
22 February 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1489423
24 March 2000 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1048248
2 September 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1393290
14 August 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 643084
3 June 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 190572
19 April 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 664464
2 March 1999 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432063
24 November 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1122263
24 November 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1444102
29 January 1998 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 784733
3 December 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 664465
6 November 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1386121
15 September 1997 Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1418293
27 September 1996 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1469144
17 June 1996 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1454361
29 September 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 875774
15 September 1995 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1182766
28 September 1994 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175976
9 November 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1154542
1 October 1993 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1147602
28 September 1992 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1265975
24 September 1991 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1245487
10 September 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 932572
4 September 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1253553
1 October 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1237081
5 September 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899683
21 February 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1210871
2 October 1989 COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1001435
2 October 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1309203
4 January 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1038813
29 November 1988 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1205756
3 October 1988 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1198127
13 September 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1353148
17 November 1987 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1332801
13 October 1987 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1014279
2 September 1987 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1310256
22 October 1986 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1324607
8 September 1986 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1011946
31 October 1985 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1292617
6 September 1985 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1296205
6 November 1984 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 976694

Deficiency record · 103

Electrical › Electrical Distribution System (service)
Issued 13 September 2002 Resolved
Remove "permanent" extension cord from engineroom. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 1 October 2002
Resolved 28 August 2003
Electrical › Lighting (service)
Issued 13 September 2002 Resolved
Provide glass globe for naked lights in engineroom. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 1 October 2002
Resolved 28 August 2003
Engineering › Fuel Oil Service System
Issued 13 September 2002 Resolved
Replace fuel oil hose on main generator with SAE J-1475, marine grade flexible hose. LEGACY COMPONENT DESC: Hose
Condition: Placed in Improper Service
Due 1 October 2002
Resolved 28 August 2003
Engineering › Diesel Engine (auxiliary)
Issued 13 September 2002 Resolved
Prove proper operation of starboard MDE high water temperature gauge located on bridge..
Condition: Unknown
Due 1 October 2002
Resolved 28 August 2003
Fire Fighting › Fire Pumps
Issued 13 September 2002 Resolved
Prove proper operation of fire pumps (60 psi @ 50 gpm). LEGACY COMPONENT DESC: Pressure
Due 1 October 2002
Resolved 28 August 2003
Fire Fighting › Firemans Outfit
Issued 13 September 2002 Resolved
Properly label fire axe with vessel's name. LEGACY COMPONENT DESC: Axe
Due 1 October 2002
Resolved 28 August 2003
Communications › Alarms/Indicators
Issued 13 September 2002 Resolved
Prove proper operation of bilge high water alarm. LEGACY COMPONENT DESC: Bilge Alarm
Due 1 October 2002
Resolved 28 August 2003
Pollution Prevention/Response › Prevention Equipment
Issued 13 September 2002 Resolved
Secure unrestricted overboard discharge of sink drain. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Condition: Improper Installation
Due 1 October 2002
Resolved 28 August 2003
Documentation › Markings/Placards
Issued 13 September 2002 Resolved
Post Emergency Broadcast plard near VHF-FM radio.
Due 1 October 2002
Resolved 28 August 2003
Lifesaving › Lifejacket/PFD (General)
Issued 13 September 2002 Resolved
Properly label adult life jacket storage. LEGACY COMPONENT DESC: Storage
Due 1 October 2002
Resolved 28 August 2003
Lifesaving › Lifebuoys
Issued 13 September 2002 Resolved
Properly label forward ring buoy with vessels name and homeport. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 1 October 2002
Resolved 28 August 2003
Documentation › Certificates/Documents
Issued 13 September 2002 Resolved
Post Stability Letter and Emergency Instructions in pilot house. LEGACY COMPONENT DESC: Stability Letter
Due 1 October 2002
Resolved 28 August 2003
Electrical › Electrical Distribution System (service)
Issued 26 February 2002 Resolved
IN THE PILOT HOUSE 208 VAC POWER PANEL, INSERT A BLANK IN THE OPEN BREAKER SPACE. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 22 March 2002
Resolved 2 April 2002
Lifesaving › Lifebuoys
Issued 26 February 2002 Resolved
RENEW THE BUOYANT LINE FOR THE FORWARD RING BUOYS. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 22 March 2002
Resolved 2 April 2002
Electrical › Electric Supply System (service)
Issued 26 February 2002 Resolved
INSTALL A FIXED ELECTRICAL RECEPTICAL FOR THE CRT IN THE MAIN DECK DINING ROOM
Condition: Improper Installation
Due 22 March 2002
Resolved 2 April 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 26 February 2002 Resolved
INSTALL AN APPROVED BRACKET FOR THE CO2 HAND PORTABLE FIRE EXTINGUISHER IN THE MAIN DECK DINING ROOM FORWARD STBD SIDE. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Unknown
Due 22 March 2002
Resolved 2 April 2002
Fire Fighting › Fixed Fire Detection System
Issued 26 February 2002 Resolved
INTHE GALLEY, INSTALL A SMOKE AND FIRE DETECTOR THAT IS U/L LISTED IN PLACE OF THE MISSING DETECTOR. LEGACY COMPONENT DESC: Heat Detectors
Condition: Improper/Lack of Maintenance
Due 22 March 2002
Resolved 2 April 2002
Engineering › Freshwater System (intermediary cooling)
Issued 26 February 2002 Resolved
IN THE ENGINEROOM, PROPERLY MOUNT THE AUXILIARY HYDRAULIC COOLING WATER PUMP. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Due 22 March 2002
Resolved 2 April 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 26 February 2002 Resolved
REMOVE THE VERMIN FROM THE VESSEL.
Condition: Unknown
Due 22 March 2002
Resolved 2 April 2002
Documentation
Issued 24 November 1998 Resolved
PROVIDE VALID CERTIFICATE OF INSPECTION PRIOR TO PERMITTING MORE THAN SIX PASSENGERS FOR HIRE ON BOARD THE VESSEL.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Documentation
Issued 24 November 1998 Resolved
PROVIDE 1 ADDITIONAL FCC STATION LICENSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Construction/Loadline
Issued 24 November 1998 Resolved
PROVIDE/POST DIAGRAM OF FIRE/BILGE SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Engineering
Issued 24 November 1998 Resolved
INSULATE BOTH MAIN ENGINE EXHAUST LINES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Lifesaving
Issued 24 November 1998 Resolved
PROVIDE SUITABLE RESCUE LADDER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Documentation
Issued 24 November 1998 Resolved
CONDUCT COI INSPECTION AS PER 46 CFR 176.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Lifesaving
Issued 24 November 1998 Resolved
INSTALL HALYARD CLIP ON RING BUOY WATERLIGHT LIGHT LINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Fire Fighting
Issued 24 November 1998 Resolved
RENEW 2ND DECK FIRE HOSE PRIOR TO BOARDING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Engineering
Issued 24 November 1998 Resolved
INSULATE GENERATOR TURBOCHARGER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Construction/Loadline
Issued 24 November 1998 Resolved
LABEL ALL UNLABELED VALVES ON BILGE/FIRE MANIFOLD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Engineering
Issued 24 November 1998 Resolved
RENEW RUBBER HOSE ON STB. ENGINE RAW WATER SUCTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Engineering
Issued 24 November 1998 Resolved
DOUBLE CLAMP ALL GENERATOR RAW WATER HOSES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Lifesaving
Issued 24 November 1998 Resolved
CONDUCT UNDERWAY MAN OVER BOARD DRILL IN PRESCENCE OF CG MARINE INSPECTOR._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Unknown
Issued 24 November 1998 Resolved
INSTALL GUARD ON ENG. RM. EXHAUST FAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Lifesaving
Issued 6 November 1997 Resolved
REPLACE ALL LIFERINGS WITH CG APPROVED LIFERINGS FOR VSL SIZE WITH RETROREFLECTIVE TAPE.
Condition: Unknown
Due 13 November 1997
Resolved 3 December 1997
Documentation
Issued 6 November 1997 Resolved
Unknown Component - Unknown Cause/Condition (46C.F.R.2.10-20)
Condition: Unknown
Due 6 November 1997
Resolved 3 December 1997
Engineering
Issued 6 November 1997 Resolved
CLEAN AND REPLACE PADDLES ID BY USCG INSPECTOR.
Condition: Unknown
Due 6 December 1997
Resolved 30 January 1998
Engineering
Issued 6 November 1997 Resolved
PROPERLY LABEL PORT SIDE FUEL SHUTOFF PULL VALVE STATION AND VENT.
Condition: Unknown
Due 6 December 1997
Resolved 30 January 1998
Fire Fighting
Issued 6 November 1997 Resolved
PROVIDE VARI-NOZZLE FOR PORT SIDE FIRE STATION.
Condition: Unknown
Due 13 November 1997
Resolved 3 December 1997
Unknown
Issued 6 November 1997 Resolved
PROVIDE UPDATED FIRST AID KIT.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Construction/Loadline
Issued 6 November 1997 Resolved
MAKE PROPER REPAIR TO WASTED AREA ON PORT SMOKE STACK.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Documentation
Issued 6 November 1997 Resolved
PROVIDE CORRECT NAMEPLATE DATA FOR M/E ROOM AIR COMPRESSOR (OR REPLACE COMPRESSOR) AND REPLACE RELIEF VALVE WITH A VALVE CORRECTLY RATED FOR COMPRESSOR.
Condition: Unknown
Due 6 December 1997
Resolved 30 January 1998
Documentation
Issued 17 June 1996 Resolved
REPLACE FLOATATION MATERIAL IN COMPT #2 AS SPECIFIED ON VSL STABILITY LTR.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Electrical
Issued 17 June 1996 Resolved
LOCATE SOURCE OF APPARENT ELECTROLYSIS VICINITY OF PORT BOW AND CORRECT SAME. PROVIDE RPT OF FINDINGS TO [name withheld].
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Lifesaving
Issued 17 June 1996 Resolved
REMOVE FLAMMABLE STORES FROM ENG. RM.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Construction/Loadline
Issued 29 September 1995 Resolved
At next haul out permanently mark vessel drafts on port and starboard fore & aft hull per vessels line drawing. Provide copy of vessels line drawing to CG Marine Inspector at time of vessel haul out.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Electrical
Issued 29 September 1995 Resolved
Install cover over opening on battery charger.
Condition: Unknown
Due 6 October 1995
Resolved 27 February 1996
Engineering
Issued 29 September 1995 Resolved
Install one solid length of hose from strainer to starboard exhaust.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Construction/Loadline
Issued 29 September 1995 Resolved
Label bilge manifold.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Fire Fighting
Issued 29 September 1995 Resolved
Install metallic hose nozzle on aft fire hose.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Fire Fighting
Issued 29 September 1995 Resolved
Label fire axe with vessel's name.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 29 September 1995 Resolved
Provide watertight container for flares.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Engineering
Issued 29 September 1995 Resolved
Double clamp all raw water hoses in engineroom.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Electrical
Issued 29 September 1995 Resolved
Install guard over flourescent light fixture in galley.
Condition: Unknown
Due 6 October 1995
Resolved 27 February 1996
Construction/Loadline
Issued 15 September 1995 Resolved
Crop and renew approximately 8" x 30" forward bulkhead, compartment 4 in way of buckle and fracture.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Engineering
Issued 15 September 1995 Resolved
Adjust the emergency fuel shutoff cable to fully close valve.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Engineering
Issued 15 September 1995 Resolved
Remove hose from fuel tank drain and cap valve.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Construction/Loadline
Issued 15 September 1995 Resolved
Weld up all small holes around main deck hatches.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Engineering
Issued 15 September 1995 Resolved
Crop and renew wasted flanges on paddle wheel supports.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Engineering
Issued 15 September 1995 Resolved
Renew port and starboard upper outboard paddle wheel supports.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Construction/Loadline
Issued 15 September 1995 Resolved
Crop and renew web frame, upper portion bulkhead to motor support starboardside.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Construction/Loadline
Issued 15 September 1995 Resolved
Crop and renew all wasted web frame stiffeners on paddle wheel support.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Navigation
Issued 15 September 1995 Resolved
Renew port and starboard rudder posts and lower bushing.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Documentation
Issued 28 September 1994 Resolved
Renew FCC Radiotelephony Safety Certificate. Vsl route is restricted to not more than 1000' from shore until complete.
Condition: Unknown
Due 21 October 1994
Resolved 21 October 1994
Construction/Loadline
Issued 1 October 1993 Resolved
Weld internally 10" side insert port side sewage tank compt. prior to carrying passengers.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Construction/Loadline
Issued 1 October 1993 Resolved
Weld stern insert - internally prior to carrying passengers.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Electrical
Issued 1 October 1993 Resolved
Install cover on emergency battery box prior to carrying passengers.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Electrical
Issued 1 October 1993 Resolved
Install cover over fuses above emergency battery.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Navigation
Issued 1 October 1993 Resolved
Install and test stern light prior to departure from dock.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Construction/Loadline
Issued 1 October 1993 Resolved
Make and maintain temporary repairs to 2 wasted overhead areas top deck aftprior to carrying passengers.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Fire Fighting
Issued 1 October 1993 Resolved
Replace dry chem. extinguisher bracket galley and provide Co2 bracket upperdeck.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Electrical
Issued 1 October 1993 Resolved
Renew stuffing tubes on stern top deck that are wasted.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Engineering
Issued 24 September 1991 Resolved
INSTALL FLAME SCREEN ON GOOSENECK VENT FOR FUEL OIL TANK.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Navigation
Issued 24 September 1991 Resolved
RENEW LENS FOR STERN LIGHT.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Construction/Loadline
Issued 4 September 1991 Resolved
REPLACE 2' X 2' DECK PLATE ON STARBOARD PADDLEWHEEL ACCESS PLATFORM. TO BECOMPLETED TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 September 1991
Resolved 4 September 1991
Construction/Loadline
Issued 4 September 1991 Resolved
REPLACE STARBOARD TOP PLATE AFT OF PADDLEWHEEL PEDESTAL BEARING: REPLACE SAME PLATE ON PORT SIDE. TO BE COMPLETED TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 September 1991
Resolved 4 September 1991
Lifesaving
Issued 1 October 1990 Resolved
PROVIDE 6 RED AND 6 ORANGE HAND HELD FLARES NLT 2OCT90.
Condition: Unknown
Due 1 October 1990
Resolved 1 October 1990
Construction/Loadline
Issued 5 September 1990 Resolved
CREDIT DRYDOCK DUE 05MAR92. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Electrical
Issued 2 October 1989 Resolved
ENCLOSE TRANSFORMER FOR DRINK DISPENSER IN GALLEY. PROVIDE CG APP'D POWER SUPPLY CABLE. SAME FOR TRANSFORMERS IN OFFICE.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REPLACE 18AWG SJO CABLE ON FOOD WARMER LAMPS.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REPAIR PLUG ON WARMER TABLE.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Construction/Loadline
Issued 2 October 1989 Resolved
PROVIDE 2 POWER BILGE PUMPS WITH INDEPENDENT POWER SOURCES.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Construction/Loadline
Issued 2 October 1989 Resolved
DEMONSTRATE THE POWER FIRE PUMP CAN ACHIEVE 60PSI AT THE PUMP WITH ONE HOSEOPEN.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
PROVIDE LIGHT GLOBES FOR ALL EXTERIOR FIXTURES.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Construction/Loadline
Issued 2 October 1989 Resolved
REPAIR THE 5 WEEPING WELDS LOCATED ON THE BOTTOM OF THE SEWAGE TANK (2 ON FWD BLKHD, 2 ON STBD BLKHD AND 1 ON AFT BLKHD). THESE REPAIRS ARE TO BE COMPLETED NO LATER THAN 03OCT89.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Documentation
Issued 2 October 1989 Resolved
CREDIT DRYDOCK DUE 20MAR91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Engineering
Issued 2 October 1989 Resolved
PROVIDE HEAT SHIELD KITS FOR 2 RACOR FUEL FILTERS.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REMOVE EXTENSION CORD IN LOWER GALLEY OVERHEAD.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REMOVE ALL 6 OUTLET ADAPTORS THRU OUT THE VESSEL. USE STANDARD HARD WIRED OUTLETS WHERE NEEDED.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Fire Fighting
Issued 2 October 1989 Resolved
SERVICE ONE B-II IN UPPER GALLEY.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
PLUG HOLE WITH BLANK OR SPARE CIRCUIT BREAKER, MAIN PANEL OF GALLEY.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REMOVE 3 OUTLET ADAPTERS IN GALLEY.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REMOVE 2 CONDUCTOR LAMP CORDS PLUGGED IN UPPER GALLEY GOING INTO THE CEILING.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REMOVE EXTENSION CORD TO ICE CREAM FREEZER.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REMOVE 2 OUTLET ADAPTORS IN OFFICE.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Fire Fighting
Issued 2 October 1989 Resolved
RELOCATE B-I FROM UPPER GALLEY TO WHEELHOUSE.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Fire Fighting
Issued 2 October 1989 Resolved
RELOCATE WHEELHOUSE B-II TO UPPER DINING ROOM.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Fire Fighting
Issued 2 October 1989 Resolved
RELOCATE ONE B-II FROM LOWER GALLEY TO LOWER DINING ROOM.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Navigation
Issued 2 October 1989 Resolved
REPOSITION MASTHEAD LIGHT/SIDE LIGHTS TO MEET THE INLAND NAV. RULES 84.03(G).
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
DEMONSTRATE POWER AVAILABLE LIGHTS ON SWITCHBOARD.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 3 October 1988 Resolved
PROVIDE A RUBBER INSULATION MAT UNDER ELECTRICAL SWITCH BOARD.
Condition: Unknown
Due 3 October 1988
Resolved 3 October 1988
Documentation
Issued 3 October 1988 Resolved
PROVIDE A VALID FCC SAFETY RADIO CERTIFICATE. UNTIL CERTIFICATE IS PROVIDEDVESSEL IS RESTRICTED TO 1000' FROM SHORE.
Condition: Unknown
Due 3 October 1988
Resolved 3 October 1988
Documentation
Issued 3 October 1988 Resolved
PROVIDE A VALID FLC RADIO STATION LICENSE. UNTIL LICENSE IS PROVIDED VSL IS RESTRICTED TO 1000' FROM SHORE.
Condition: Unknown
Due 3 October 1988
Resolved 3 October 1988
Navigation
Issued 13 September 1988 Resolved
RENEW FIVE (5) PADDLE BOARDS ON STBD. STERN WHEEL AS MARKED.
Condition: Unknown
Due 13 September 1988
Resolved 13 September 1988

Ownership record