MAURY USCG vessel records Sign in
← All vessels

IDLEWILD

IDLEWILD is a 1978 freight ship. The Coast Guard has recorded 37 inspections since 1982, most recently in November 2010, along with 16 deficiencies.

Records from 1982 to 2010. Most recent: inspection, 8 November 2010.

Built
1978
Last inspected
8 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8978112 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZJL7307
Flag
VIRGIN ISLANDS, BRITISH
366746060 (licence lapsed)
Maury page id
psix-49546

Inspections, by type

…with no type recorded13
Years with a record 21 calendar years (1982–2010)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Net Ton
93 - Regulatory (Subpart C or D), Gross Ton
207 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCX2725MMSI 366746060 · cancelled · compulsorily equipped · granted 23 March 1998, cancelled 17 June 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 37

8 November 2010 PII Safety Exam · ISPS II Exam · Deficiency Check · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3888068
24 May 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2076687
31 August 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822176
31 August 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1069037
30 June 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 517946
8 September 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401078
20 October 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807077
25 September 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461914
24 June 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 721604
30 May 1998 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793189
25 May 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 44086
2 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783522
5 September 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428845
27 January 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1100940
28 August 1996 Re-Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425786
26 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764709
23 February 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 190442
25 August 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409352
10 August 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414333
11 August 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460650
19 August 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665615
12 August 1992 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354184
11 August 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665616
5 August 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 48673
28 August 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1246950
9 August 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936053
6 September 1990 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930201
30 August 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1198898
20 July 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341394
4 September 1987 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314692
10 October 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012106
30 September 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319076
4 September 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302358
2 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287242
30 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976336
30 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273651
11 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968138

Deficiency record · 16

Communications › Radio Communications › EPIRB
Issued 8 November 2010 Resolved
Provide a hydrostatic release for the EPIRB, which was noted to be attached to the mast with line. CC 5.13.3.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2010
Lifesaving › Inflatable Liferafts › Float Free
Issued 8 November 2010 Resolved
Provide an operational hydrostatic release for the life raft, noted device to be expired by almost 6 months. CC 4.9.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2010
Navigation › Piloting/Steering › Compass Deviation Table
Issued 8 November 2010 Resolved
Obtain an updated Compass Deviation Card, noted current card to be more than 5 years old and vessel had changed service with modifications. CC 6.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 November 2010
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 November 2010 Resolved
Provide manning IAW Minimum Safe Manning Document. Noted Master to not have required tonnage and only 4 crew vice the required 5.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2010
Navigation › Piloting/Steering › Marine Charts
Issued 8 November 2010 Resolved
Obtain current charts for St. Thomas and next port of call. CC 6.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2010
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 November 2010 Resolved
Obtain light list, Coast Pilot and Tide and Current Tables. CC 6.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 November 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 November 2010 Resolved
Obtain a suitable first aid kit. Noted a severely depleted and outdated chest on board.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 November 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 November 2010 Resolved
Repair emergency lighting, noted only galley E Lights to activate. CC 2.34
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2010
Construction/Loadline › Structures › End Bulkhead
Issued 8 November 2010 Resolved
Make forward engine room WTD water tight. Noted penetrations for wiring open.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 November 2010
Resolved 9 November 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 8 November 2010 Resolved
Provide portable fire extinguishers iaw Fire Control Plan. Noted all appliances to be 20#.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 November 2010
Fire Fighting › Nozzles › Condition
Issued 8 November 2010 Resolved
Noted fire nozzles to be plastic and worn and not operating as dual purpose. CC (3.5)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 November 2010
Construction/Loadline › Structures › Door
Issued 8 November 2010 Resolved
Noted WTD in engine room to have no gasket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 November 2010 Resolved
Provide adequate insulation wrap for the generator dry exhaust. CC (2.32)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 November 2010
Accommodation/Occupational Safety
Issued 25 September 1998 Resolved
PROVIDE SEWAGE HOLDING TANK 3/4 FULL LEVEL INDICATOR.
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Electrical
Issued 25 September 1998 Resolved
PROVIDE EMERGENCY POWER SUPPLY FOR SSB RADIO.
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Lifesaving
Issued 30 September 1986 Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO GETTING UNDERWAY. LOG ENTRY ON DRILLS ARE TO BE MADE AND ACKNOWLEDGED BY VESSEL PORT CAPTAIN.
Condition: Unknown
Due 30 September 1986
Resolved 30 September 1986

Ownership record