MAURY USCG vessel records Sign in
← All vessels

C-AGGRESSOR

C-AGGRESSOR is a 2000 offshore supply vessel. The Coast Guard has recorded 23 inspections since 1999, most recently in July 2017, along with 20 deficiencies.

Records from 1999 to 2017. Most recent: inspection, 7 July 2017.

Built
2000
Last inspected
7 July 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9226279 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDF2739
495589
Flag
VANUATU
338668000, 367431350 (licence lapsed)
Maury page id
psix-495589

Inspections, by type

…with no type recorded3
Years with a record 13 calendar years (1999–2017)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1843 - Dead Weight, Ton
1200 - Convention (Subpart B), Gross Ton
385 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF2739MMSI 367431350 · expired · compulsorily equipped · granted 13 November 2009, cancelled 18 January 2020
WCZ6127MMSI 338668000 · expired · compulsorily equipped · granted 30 December 1999, cancelled 6 March 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

7 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6201218
23 December 2010 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3915496
8 December 2009 Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3650576
19 February 2009 Re-Inspection · Ballast Water Examination · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3420391
1 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3196563
24 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3222061
7 February 2008 Cargo Tank Internal · Underwater Inspection in lieu of Drydock · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3159136
15 February 2007 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2875639
13 February 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2584479
25 October 2005 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2524084
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501684
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293979
2 February 2005 Internal Structural Exam · Cargo Tank Internal · COI Inspection · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2286841
24 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2247389
17 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2246996
25 July 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2160913
24 March 2004 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2030733
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979586
6 February 2003 Underwater Inspection in lieu of Drydock · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1740875
31 January 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1482937
5 March 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397588
21 February 2000 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376057
17 May 1999 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 795742

Deficiency record · 20

Fire Fighting › Means of Escape › Emergency Lighting
Issued 15 February 2007 Resolved
The emergency light at the main electrical panel did not function.
Due 28 February 2007
Resolved 15 February 2007
Resolution: Replaced battery
Stability › Watertight Integrity › General
Issued 15 February 2007 Resolved
The dogging wrench for the engine room watertight door was missing.
Due 28 February 2007
Resolved 15 February 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 15 February 2007 Resolved
The emergency shut down for the #2 liquid mud tank did not function.
Due 28 February 2007
Resolved 15 February 2007
Communications › Visual Communication › Red Warning Signal
Issued 15 February 2007 Resolved
The general alarm light for the engine room did not have the red lens installed.
Due 28 February 2007
Resolved 15 February 2007
Electrical › Electric Generation Source (service) › Generator
Issued 15 February 2007 Resolved
The port generator airline had a broken valve handle on the air line.
Due 28 February 2007
Resolved 15 February 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 15 February 2007 Resolved
The port and starboard freeboard deck reference lines needed to be painted.
Due 15 February 2007
Resolved 15 February 2007
Stability › Watertight Integrity › General
Issued 15 February 2007 Resolved
The engine room (aft) watertight door needed to be realigned.
Due 28 February 2007
Resolved 15 February 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 February 2007 Resolved
The oily water separator was not operational.
Due 15 February 2007
Resolved 15 February 2007
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 15 February 2007 Resolved
The lube oil pressure alarm did not function.
Due 28 February 2007
Resolved 15 February 2007
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 February 2003 Resolved
REPAIR SECOND RADAR.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2003
Resolved 5 March 2003
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 February 2003 Resolved
PROVIDE CURRENT COPY OF NAVIGATIONAL RULES.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2003
Resolved 5 March 2003
Fire Fighting › Ventilation Systems
Issued 6 February 2003 Resolved
REPAIR EMERGENCY GENERATOR SPACE FIRE DAMPER. LEGACY COMPONENT DESC: FIRE DAMPER
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2003
Resolved 5 March 2003
Engineering › Compressed Air System (start air) › Valve
Issued 6 February 2003 Resolved
REPAIR OR RENEW STARBOARD AIR RECEIVER PRESSURE RELIEF VALVE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 March 2003
Resolved 6 February 2003
Engineering › Bilge Water Management System › Valve
Issued 31 January 2002 Resolved
CONDUCT MAINTENANCE ON THE FOREPEAK REACHROD AND DEMONSTRATE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2002
Resolved 31 January 2002
Electrical › Electric Generation Source (service)
Issued 31 January 2002 Resolved
REPLACE BULB IN ENGINE ROOM GENERAL ALARM VISUAL INDICATOR LEGACY COMPONENT DESC: LIGHT
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2002
Resolved 31 January 2002
Construction/Loadline › Structures › Door
Issued 31 January 2002 Resolved
PROPERLY ADJUST ALL WATERTIGHT DOORS BELOW THE MAIN DECK.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2002
Resolved 31 January 2002
Engineering › Fuel Oil Service System › Filter
Issued 31 January 2002 Resolved
INSTALL METALLIC PLUGS IN ALL ENGINE ROOM F/O FILTERS.
Condition: Improper/Lack of Maintenance
Due 31 January 2002
Resolved 31 January 2002
Engineering › Fuel Oil Service System › Pump
Issued 31 January 2002 Resolved
PROPERLY LABEL DIRTY OIL DISCHARGE PUMP EMERGENCY SHUT-OFF
Condition: Improper Installation
Due 31 January 2002
Resolved 31 January 2002
Engineering › Steering Gear System › Hydraulic Hose
Issued 31 January 2002 Resolved
INSTALL CHAFING GEAR ON THE P & S "Z" DRIVE HYDRAULIC HOSES LEADING TO THE EXPANSION TANKS AND LEADING TO THE REMOTE OPERATION SOLENOID.
Condition: Improper/Lack of Maintenance
Due 31 January 2002
Resolved 31 January 2002
Deck/Cargo
Issued 5 March 2001 Resolved
Bring crane into compliance with 46 CFR 126.130.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.