Records from 2016 to 2025. Most recent: inspection, 30 April 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)48.4 ft × 15.1 ft × 5.2 ft
Registered tonnagegross 32 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLITTLE HOQUIAM/GRAYS HBR · HOQUIAM WA: ABERDEEN WA · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOMER, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 4 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
30 April 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8124253
21 April 2025
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8116626
30 May 2024
Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7934968
22 May 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7915931
22 August 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7774629
16 May 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7691014
25 April 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7675804
25 April 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7440404
24 August 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7295668
28 April 2021
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7205910
22 April 2021
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7180703
29 May 2020
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6963835
21 April 2020
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6950010
3 October 2019
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6827505
15 April 2019
Annual Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6667749
2 May 2018
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6394298
24 April 2017
Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6161982
4 May 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5869215
16 February 2016
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5837546
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 May 2024
Resolved
Prove proper operation of stern light. Vessel restricted to daylight voyages only.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 28 May 2024
Resolution: repaired
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 16 May 2023
Resolved
Provide a valid FCC Station License
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 17 May 2023
Resolution: provided
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2023
Resolved
If vsl wants to have 08 overnight pax, must comply with IFR regs or submit request to reduce overnight pax to 06 or less.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 16 May 2023
Resolution: Received request to overnight pax to 06 or less
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 May 2023
Resolved
Ensure wires in engine room are supported by approved metal supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 15 August 2023
Resolution: received notification that def is cleared
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 16 May 2023
Resolved
Renew bridge port aft window. 46CFR177.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 15 August 2023
Resolution: received notification that def is cleared
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 May 2023
Resolved
Ensure all crew is enrolled in a CG approved drug testing program prior to serving in a safety sensitive position.
Action required: 10 - Deficiency Rectified
Resolved 16 May 2023
Resolution: educated master on requirements
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 April 2022
Resolved
Ensure aft engine room bulkhead is watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2022
Resolution: hole filled
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 April 2022
Resolved
Ensure the stbd air intake for engine room is able to be closed in the event of a fire. There is a hose running down the cowling.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2022
Resolution: hose removed
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 25 April 2022
Resolved
Provide valid FCC safety cert 47CFR80.59
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2022
Resolved 17 May 2023
Resolution: received copy of valid FCC Station License
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 29 May 2020
Resolved
Replace faded, illegible Emergency Instructions and post onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 3 June 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 May 2020
Resolved
Provide additional smoke detector to overnight accommodations berthing area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 3 June 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 May 2020
Resolved
Replace Emergency Exit sign to ensure letters are at lease 2" high and visible in the dark
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 3 June 2020
Resolution: Signs acquired
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 May 2020
Resolved
Epirb battery is expired and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 29 May 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 May 2020
Resolved
FCC Station license is expired and needs to be renewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 29 May 2020
Resolution: Certificate renewed
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2018
Resolved
Ring Bouy grab line was found dry rotted and sun damaged. Replace grab line.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 April 2019
Resolution: New grab line onboard
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2018
Resolved
First Aid Kit does not contain all required supplies.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 April 2019
Resolution: Required contents have been renewed
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 May 2018
Resolved
Make collision bulkhead watertight at hydraulic hose penetrations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 April 2019
Resolution: bulkhead penetration was sealed up
Electrical › Electric Supply System (service) › Cable
Issued 2 May 2018
Resolved
Dead end electrical wiring found next to the freshwater tank. Remove or place in junction box.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 April 2019
Resolution: wire has been removed
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 May 2018
Resolved
Replace retro-reflective material on 01 lifejacket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 April 2019
Resolution: new retro tape on lifejacket
Engineering › Bilge Water Management System › Pump
Issued 2 May 2018
Resolved
Bilge pump located in lazarette does not automatically activate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 30 April 2019