MAURY USCG vessel records Sign in
← All vessels

INT'L ENFORCER

INT'L ENFORCER is a 1978 offshore supply vessel. The Coast Guard has recorded 61 inspections since 1981, most recently in July 2012, along with 77 deficiencies.

Records from 1981 to 2012. Most recent: inspection, 30 July 2012.

Built
1978
Last inspected
30 July 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYF5015
Flag
PANAMA
367338440 (licence lapsed)
Maury page id
psix-49575

Inspections, by type

…with no type recorded17
Years with a record 28 calendar years (1981–2012)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WYF5015MMSI 367338440 · expired · compulsorily equipped · granted 20 February 2008, cancelled 14 July 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 61

30 July 2012 NPV Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4395996
8 January 2009 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3390901
17 September 2007 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3059740
24 July 2007 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3006061
9 April 2007 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2904474
9 April 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2904487
26 October 2005 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2522347
4 October 2005 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2507830
25 January 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2280367
10 January 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2273307
21 December 2004 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2263201
5 November 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2232371
9 January 2004 Annual Inspection · Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1982101
10 January 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1728693
1 October 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1681167
6 December 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 772754
6 May 2001 Type not recorded
No type recorded · USCGC KEY BISCAYNE (WPB 1339) · USCG Southeast District (CGD-SE) · Activity 1521580
11 October 2000 Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1425000
9 November 1999 Deficiency Check · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1451467
21 October 1999 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 824715
21 October 1999 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1420205
22 February 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1131121
15 November 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 806959
15 October 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1420009
17 April 1998 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1465956
4 December 1997 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1388419
17 October 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1427267
12 August 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1089630
30 March 1995 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1434269
21 March 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355132
3 May 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 858317
28 April 1994 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1389821
6 March 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362716
29 May 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 949944
29 April 1992 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 948094
21 May 1991 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1227516
20 May 1991 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 915618
24 April 1991 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 925387
24 April 1991 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1236047
10 April 1991 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 916167
10 April 1991 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1236756
24 August 1990 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1213155
26 July 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926144
11 January 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 908918
14 April 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 893917
15 August 1988 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1037020
26 April 1988 Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1038176
26 May 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1025898
14 April 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1311126
13 June 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1293955
3 June 1986 Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 986842
9 April 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 999329
24 October 1985 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1300129
8 August 1985 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 984424
28 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1288130
27 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 980031
1 October 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280342
29 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 972687
31 March 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278985
29 September 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969352
12 May 1981 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963680

Deficiency record · 77

Construction/Loadline › Hull › Hull Plating
Issued 9 April 2007 Resolved
Failure to obtain approval for repairs/alterations to the hull machinery, or equipment that affects vsl safety.
Action required: 705 - Other - as specified
Due 9 April 2007
Resolved 27 March 2008
Resolution: Completed credit hull exam.
Lifesaving › Lifefloat › Float-free Link
Issued 12 October 2005 Resolved
Provide proper weak link for life float.
Due 22 October 2005
Resolved 26 October 2005
Resolution: CG approved float free link on board vessel.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 December 2004 Resolved
Replace cover to AC distribution panel enclosure under bridge console.
Due 21 December 2004
Resolved 21 December 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 December 2004 Resolved
Upgrade first aid kit to meet 46/160.041 specs.
Due 21 December 2004
Resolved 21 December 2004
Documentation › Markings/Placards › Capacity Marking
Issued 21 December 2004 Resolved
Make air receiver placard legible.
Due 21 December 2004
Resolved 21 December 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 December 2004 Resolved
Provide one Type I PFD w/PML and vessel name.
Due 21 December 2004
Resolved 21 December 2004
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 21 December 2004 Resolved
Complete & submit annual MIS reports iaw 46 CFR Part 16.
Due 21 December 2004
Resolved 21 December 2004
Electrical › Electrical Distribution System (service)
Issued 12 January 2004 Resolved
Cut wire in engineroom overhead not properly terminated. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2004
Resolved 13 January 2004
Fire Fighting › Fire Main
Issued 12 January 2004 Resolved
Starboard side of engineroom, firemain deck riser pipe wasted along horizontal run. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2004
Resolved 13 January 2004
Construction/Loadline › Structures
Issued 12 January 2004 Resolved
Deck framing in vicinity of starboard side enginroom escape ladder wasted. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2004
Resolved 13 January 2004
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 10 January 2003 Resolved
Floatation wasted in 2 jackets.
Due 10 January 2003
Resolved 10 January 2003
Resolution: Crew replaced lifejackets during inspection.
Engineering › Steering Gear System
Issued 11 October 2002 Resolved
Rudder shaft packing nuts loose on port and starboard rudders. LEGACY COMPONENT DESC: Rudder
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 October 2002
Construction/Loadline › Hull › Hull Plating
Issued 11 October 2002 Resolved
Completion of cleaning of underwater body revealed another doubler that must be cut out and repaired with an insert.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 October 2002
Construction/Loadline › Hull
Issued 1 October 2002 Resolved
Make entire bottom clean and available for inspection LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Resolved 11 October 2002
Construction/Loadline › Hull
Issued 1 October 2002 Resolved
Crop and renew doubler plate and circular insert in hull on aft port area. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 October 2002
Construction/Loadline › Hull
Issued 1 October 2002 Resolved
Crop and renew to good metal the cracked/wasted transverse angle bracket in steering gear room. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 October 2002
Construction/Loadline › Hull
Issued 1 October 2002 Resolved
Renew 3 trip brackets on stbd side as marked in aft ballast tank. Crop and renew transverse flange plate frame.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 October 2002
Construction/Loadline › Hull
Issued 1 October 2002 Resolved
Remove flex hose and make proper repair to piping system in #2 Port Ballast Tank
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 October 2002
Construction/Loadline › Hull
Issued 1 October 2002 Resolved
Crop and renew transverse channel as marked under stbd shaft in engineroom. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 October 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 1 October 2002 Resolved
Properly torque Port Generator mounting bolts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 October 2002
Construction/Loadline
Issued 11 October 2000 Resolved
Ensure name and hailing port is properly stenciled to stern of vessel
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Engineering
Issued 11 October 2000 Resolved
Place machinery guard over pulley on starboard generator.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Navigation
Issued 11 October 2000 Resolved
Ensure Navigation Rules book has been updated or replace by new addition.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Fire Fighting
Issued 11 October 2000 Resolved
Replace damaged (leaking) fire hose.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 11 October 2000 Resolved
Post DAPI information material of community service hot-line telephone numbers for crewmember assitance.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 11 October 2000 Resolved
Ensure waste management plan addresses all requirements per 33 CFR 151.57
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 11 October 2000 Resolved
Ensure oil transfer proceedures are complete per 33 CFR 155.750
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Engineering
Issued 21 October 1999 Resolved
BACK GOUGE, REWELD 2-3 INCH AREA, #4 F/O TANK AT BILGE KNUCKLE AREA WHERE WELD APPEARS TO BE SEPERATING.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 21 October 1999 Resolved
INSTALL INSERTS, APPROX 2 X 2 FT PORT AND STARBOARD OUTBOARD LONGITUDINALS AT AFTER END OF MACHINERY SPACE.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 21 October 1999 Resolved
WELD INSERT, APPROX. 2 X 3 FT ON BOTTOM SHELL BELOW STARBOARD OUTBOARD LONGITUDINAL FRAME IN AFTER END MACHINERY SPACE.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 21 October 1999 Resolved
TEST ALL WATERTIGHT DOORS. ITEMS ARE TO BE COMPLETED PRIOR TO 21 NOV 99 TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 21 October 1999 Resolved
INSTALL BILGE ALARMS IAW 46 CFR 182.530. TO BE COMPLETED PRIOR TO 21 NOV 99 TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 21 October 1999 Resolved
WELD INSERT, APPROX. 18 X 52 INCHES, PORT SIDE, SIDE SHELL IWO #4 PORT F/O TANK.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Engineering
Issued 15 October 1998 Resolved
ENSURE EXHAUST PIPE INSULATION ON THE LEFT AND RIGHT SIDE OF BOTH MAIN DIESEL ENGINES ARE COVERING ALL HOT SURFACES.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Electrical
Issued 15 October 1998 Resolved
PROVIDE INSTALLED EMERGENCY LIGHTING FOR THE PORT AND STARBOARD EMERGENCY EXITS IN THE ENGINE ROOM, THE GENERATOR AND ELECTRICAL SWITCHBOARD.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Engineering
Issued 17 April 1998 Resolved
REPLACE VENT CLOSURE GASKET ON STBD SIDE MAIN DECK FOR ENG ROOM VENT.
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 17 April 1998 Resolved
REPAIR PIN HOLE INPORTSIDE WRAP TNK AT SHEER STRAKE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 17 April 1998 Resolved
REPAIR ANGLE IRON IN #1 STBD BALLAST TNK AFT BULKHEAD.
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 17 April 1998 Resolved
GOUGE & REWELD PORT & STBD STABILIZERS ON HULL.
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 17 April 1998 Resolved
REWELD #2 VERTICAL FRAME ON STBD SIDE BILGE WRAPPER COMPT.
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 17 April 1998 Resolved
CROP & RENEW AREA OF BAFFLE PLATE IWA OF CENTERLINE AT BILGE WRAPPER.
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Electrical
Issued 17 April 1998 Resolved
INSTALL LIGHT COVER ON STBD LIGHT IN LAZZARRETTE.
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Electrical
Issued 17 April 1998 Resolved
REPLACE CRACKED LIGHT FIXTURE IN MSD SPACE PORT SIDE.
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 17 April 1998 Resolved
GOUGE & REWELD #3 & 4 TRANSVERSE STIFFENERS IN SHAFT ALLEY.
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Engineering
Issued 17 April 1998 Resolved
REPAIR/REPLACE PORT/STBD WASTE OIL VENT SCREENS (TOTAL 4).
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 17 April 1998 Resolved
STERN WRAP TANK, CROP & RENEW 1ST GUSSET PLATE INBD PORT SIDE ON OVERHEAD._x001C__x001C_ _x001C_
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Construction/Loadline
Issued 17 April 1998 Resolved
STERN WRAP TNK, GOUGE & RENEW 18" SPLIT IN SHEER STRAKE SEAM PORT SIDE.
Condition: Unknown
Due 17 April 1998
Resolved 21 April 1998
Electrical
Issued 30 March 1995 Resolved
REMOVE PIG TAIL SPLICES LOCATED AT WHEELHOUS AND STARBOAD SIDE CREW QUARTERS.
Condition: Unknown
Due 31 March 1995
Resolved 21 June 1995
Engineering
Issued 30 March 1995 Resolved
Repair or replace water temperture guages at wheelhouse for main engines.
Condition: Unknown
Due 31 March 1995
Resolved 21 June 1995
Construction/Loadline
Issued 3 May 1994 Resolved
SCALE ENTIRE COMPARTMENT, GAUGE HULL AND SIDESHELLS (PORT/STBD/AFT) OF STERN VOID, PAYING PARTICULAR ATTENTION TO ALL FRAMING, DUE TO APPARENT WASTAGE TO THE SATISIFACTION OF THE COGNIZANT OCMI AT NEXT DRYDOCK EXAMINATION. SEE CASE #MI94016974 FOR STEERING GEAR ROOM REQUIREMENTS.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Construction/Loadline
Issued 3 May 1994 Resolved
REMOVE DOUBLER AND RENEW WASTED SECTION OF HULL PLATING TO THE SATISIFACTION OF THE COGNIZANT OCMI AT NEXT DRYDOCK EXAMINATION.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Construction/Loadline
Issued 28 April 1994 Resolved
AT NEXT DRYDOCK, SCALE AND GAUGE DECK, SIDE SHELL AND AFT BULKHEAD IN STEERING GEAR ROOM DUE TO APPARENT WASTAGE.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Construction/Loadline
Issued 28 April 1994 Resolved
AT NEXT DRYDOCK, CROP AND RENEW FOUR (4) WASTED DECK STIFFENERS (2 PORT/2 STBD) OUTBOARD OF RUDDER POSTS IN STEERING GEAR ROOM.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Accommodation/Occupational Safety
Issued 29 April 1992 Resolved
REPAIR OR REPLACE PORT EXAUST VENTILATION FAN. YOU ARE ALLOWED 30 DAYS TO MEET THIS REQUIREMENT AND MAKE AVAILABLE FOR A U.S.C.G. MARINE INSPECTOR'S INSPECTION.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Documentation
Issued 26 July 1990 Resolved
MAKE VESSEL AVAILABLE FOR MID-PERIOD REINSPECTION EXAM PRIOR TO PLACING VESSEL BACK IN SERVICE.
Condition: Unknown
Due 26 July 1990
Resolved 26 July 1990
Engineering
Issued 14 April 1989 Resolved
PROVIDE MAIN ENGINE OVERSPEED SHUTDOWN DEVICES AND MAKE THEM AVAILABLE FOR TEST IN THE PRESENCE OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Fire Fighting
Issued 14 April 1989 Resolved
REMOVE DRESSER COUPLING FROM SUCTION SIDE OF MAIN FIRE PUMP AND PROVIDE HARD PIPING IN IT'S PLACE.
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Engineering
Issued 15 August 1988 Resolved
DEMONSTRATE PROPER OPERATION OF MAIN ENGINES FULL AHEAD TO FULL ASTERN.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Construction/Loadline
Issued 15 August 1988 Resolved
INSTALL VALVE AND REACH ROD FOR STARBOARD BILGE LINE IN FORE PEAK FWD OF COLLISION BULKHEAD.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Unknown
Issued 14 April 1987 Resolved
REPAIR THE PORT WINDOW ON THE BRIDGE SO THAT IT IS WEATHERTIGHT.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
REPAIR THE LIGHTS IN THE CAPTAIN'S STATEROOM, 1ST DECK QUARTERS, AND IN THEAFT STEERING COMPARTMENT CORRIDOR.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
LABEL AND MARK MACHINERY SPACE FIRE STATION AND GENERAL ALARM.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
MARK BILGE AND BALLAST MANIFOLD VALVES.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
REMOVE STANDING WATER AND CLEAN OUT AFT STEERING COMPARTMENT TO FACILITATE STRUCTURAL EXAMINATION OF THIS SPACE.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
INSTALL A GUARD FOR THE A/C COMPRESSOR.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
REINSTALL THE COUPLING GUARD ON THE ANCHOR WINDLASS.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Unknown
Issued 14 April 1987 Resolved
REPAIR THE LORAN C RECEIVER.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Navigation
Issued 8 August 1985 Resolved
PROVIDE PROPER LIGHTS FOR VESSEL'S RUNNING LIGHTS TO MEET REQUIREMENTS OF RULE 22 OF 72 COLREGS.
Condition: Unknown
Due 8 August 1985
Resolved 8 August 1985
Navigation
Issued 28 March 1985 Resolved
MAKE PERMANENT REPAIRS TO THE STEERING GEAR HYDRAULIC LINE IN THE STAR- BOARD BALLAST TANK.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Lifesaving
Issued 27 March 1985 Resolved
PROVIDE TWO (2) ADDITIONAL TYPE I PFD'S. THE TOTAL NUMBER OF PERSONS CARRIED IS REDUCED TO 18 UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Accommodation/Occupational Safety
Issued 27 March 1985 Resolved
PERMANENTLY PIPE SALT WATER COOLING LINES TO AIR CONDITIONER AND TO FLUSH- ING PUMP FOR MSD. REMOVE RUBBER HOSES.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
PROVIDE FLAME SCREEN FOR THE LUBE OIL TANK VENT ON THE PORT SIDE.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Fire Fighting
Issued 27 March 1985 Resolved
PROVIDE SUITABLE FIRE PROTECTION FOR THE CARGO DECK.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Navigation
Issued 27 March 1985 Resolved
PROVIDE PROPER LIGHT BULBS FOR THE SIDE RUNNING LIGHTS.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Navigation
Issued 1 October 1984 Resolved
PRIOR TO SAILING PROVIDE A COPY OF A COAST GUARD LIGHT LIST, U. S. COAST PILOT, VOLUME #5, TIDE TABLE/TIDAL CURRENT TABLE.
Condition: Unknown
Due 1 October 1984
Resolved 1 October 1984
Documentation
Issued 29 May 1984 Resolved
PRIOR TO SAILING PROVIDE CPY OF THE COAST GUARD LIGHT LIST, COAST PILOT, TIDE TABLE AND TIDAL CURRENT TABLE.
Condition: Unknown
Due 29 May 1984
Resolved 29 May 1984
Unknown
Issued 29 May 1984 Resolved
THE FOLLOWING DEFICIENCY IS FOR THE IDA THOMPSON, DN590899.
Condition: Unknown
Due 29 May 1984
Resolved 29 May 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.