MAURY USCG vessel records
← All vessels

PIONEER P

Built
2000
Last inspected
5 March 2024
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 March 2024
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2022–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8964434
WDB4533
495756
Flag
NIGERIA
Maury page id
psix-495756

Documentation record

Tonnage as PSIX records it1255 - Convention (Subpart B), Gross Ton
376 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 4 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

5 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7874576
4 March 2024 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7873689
10 May 2023 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7686139
15 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7412217

Deficiency record · 10

03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 4 March 2024 Resolved
Oil tank vent on the starboard side has a loose vent screen and vent ball is exposed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: The oil tank vent screen and ball had successfully been repaired.
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 4 March 2024 Resolved
The vessel was not equipped with the international shore connection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 8 March 2024
Resolution: The vessel had on board the appropriate flanges, nuts and bolts for the international shore connection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 4 March 2024 Resolved
The deck line above the load line, marking on the hull was not painted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: The deck line on the port and starboard side were painted.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 4 March 2024 Resolved
The rudder angle indicator in engine room displayed an additional 10 degrees than the rudder angle indicator on the bridge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: Conducted a satisfactory steering test from the bridge and engine room to witness the corrected rudder angle indicator.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 4 March 2024 Resolved
The straps for the life rafts need to be tightened down.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2024
Resolved 8 March 2024
Resolution: Life raft straps were tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 4 March 2024 Resolved
The rescue boat did not have the SOLAS required equipment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2024
Resolved 8 March 2024
Resolution: All SOLAS required equipment was restored to the rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 4 March 2024 Resolved
The limit switch located on the rescue boat davit hand crank was bent, preventing it from effectivly cutting off electricity to the davit when utilziing the hand crank.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2024
Resolved 8 March 2024
Resolution: The limit switch had been replaced and the USCG witnessed an operational test of the limit switch.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 March 2024 Resolved
The currently installed CO2 system does noy meet the intent of the SOLAS and FSS required fixed firefighting. There is no installed safety valve, time delay, wintergreen scent agent, siren or release lights.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2024
Resolved 8 March 2024
Resolution: Flag had issued a dispensation letter and the Captain had artificially created an additional safety measure by removing the risk of anyone accidently going into the CO2 room, the USCG team felt that the vessel met minimum safety to make one-time voyage
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 4 March 2024 Resolved
The equipment stored on the main deck was blocking the access to fuel storage tank shut off vlaves on tanks #1, #2, #3 and #4.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: All deck equipment was moved and lashed as not to block the fuel storage tank shut offs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 March 2024 Resolved
The ground detection on the engine room switch panel for 480 V was in-operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: The ground detection lights on the switch panel were corrected.

Recorded names · 1

CANDY PIONEER (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.