Records from 1999 to 2024. Most recent: inspection, 5 March 2024.
Inspection history · 35
5 March 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7874576
4 March 2024
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7873689
10 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7686139
15 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7412217
4 December 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3435683
30 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3335408
19 June 2008
MTSA Verification · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3241757
6 September 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2770445
1 September 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2765868
25 August 2006
Deadweight Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2773075
8 June 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2674852
20 June 2005
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2392780
18 February 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2295308
15 July 2004
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2133951
18 June 2004
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2102669
18 June 2004
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2102681
17 June 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2150086
20 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2048391
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979396
7 August 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1869526
10 June 2003
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1810477
6 June 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1626906
28 May 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1663300
8 June 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395753
7 June 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 136924
18 October 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 493958
23 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821166
3 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821451
13 July 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820380
15 June 2000
Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450496
2 June 2000
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459601
20 April 2000
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454799
12 January 2000
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386668
24 August 1999
Initial Construction-Excluding Oversight
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1372747
14 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798392
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 4 March 2024
Resolved
Oil tank vent on the starboard side has a loose vent screen and vent ball is exposed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: The oil tank vent screen and ball had successfully been repaired.
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 4 March 2024
Resolved
The vessel was not equipped with the international shore connection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2024
Resolved 8 March 2024
Resolution: The vessel had on board the appropriate flanges, nuts and bolts for the international shore connection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 4 March 2024
Resolved
The deck line above the load line, marking on the hull was not painted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: The deck line on the port and starboard side were painted.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 4 March 2024
Resolved
The rudder angle indicator in engine room displayed an additional 10 degrees than the rudder angle indicator on the bridge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: Conducted a satisfactory steering test from the bridge and engine room to witness the corrected rudder angle indicator.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 4 March 2024
Resolved
The straps for the life rafts need to be tightened down.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2024
Resolved 8 March 2024
Resolution: Life raft straps were tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 4 March 2024
Resolved
The rescue boat did not have the SOLAS required equipment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2024
Resolved 8 March 2024
Resolution: All SOLAS required equipment was restored to the rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 4 March 2024
Resolved
The limit switch located on the rescue boat davit hand crank was bent, preventing it from effectivly cutting off electricity to the davit when utilziing the hand crank.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2024
Resolved 8 March 2024
Resolution: The limit switch had been replaced and the USCG witnessed an operational test of the limit switch.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 March 2024
Resolved
The currently installed CO2 system does noy meet the intent of the SOLAS and FSS required fixed firefighting. There is no installed safety valve, time delay, wintergreen scent agent, siren or release lights.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2024
Resolved 8 March 2024
Resolution: Flag had issued a dispensation letter and the Captain had artificially created an additional safety measure by removing the risk of anyone accidently going into the CO2 room, the USCG team felt that the vessel met minimum safety to make one-time voyage
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 4 March 2024
Resolved
The equipment stored on the main deck was blocking the access to fuel storage tank shut off vlaves on tanks #1, #2, #3 and #4.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: All deck equipment was moved and lashed as not to block the fuel storage tank shut offs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 March 2024
Resolved
The ground detection on the engine room switch panel for 480 V was in-operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 8 March 2024
Resolution: The ground detection lights on the switch panel were corrected.
Construction/Loadline › Hull › Hull Plating
Issued 18 June 2004
Resolved
Proceed directly to Larose LA. for repairs IWO forepeak, to include damaged bow stem and all attached internal framing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 June 2004
Resolved 22 June 2004
Engineering
Issued 15 June 2000
Resolved
INSTALL OVERSPEED TRIPS TO MAIN ENGINES AS PER 46CFR SUBCHAPTER F.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000