Records from 2008 to 2025. Most recent: inspection, 25 August 2025.
Inspection history · 17
25 August 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8173063
18 October 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7955785
11 July 2024
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7955770
3 October 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7803038
13 September 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7808224
1 September 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7762271
8 September 2022
Plan Review "T" Boat · Internal Structural Exam · Equivalency · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7511735
26 July 2022
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7510395
7 September 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7178577
9 September 2020
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024046
1 September 2020
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024074
8 August 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6770480
30 January 2019
Administrative Inspection · In-Service Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6616694
31 August 2018
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6515234
3 August 2017
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6154223
20 January 2017
Damage Survey · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6073870
19 September 2016
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6000575
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 September 2020
Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operation station. Except on a vessel limited to daytime operations, the compass must be illuminated.
The magnetic compass does not illuminate. The vessel is restricted to daytime operations until the compass light is repaired / replaced.
46CFR184.402
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 9 September 2020
Resolution: Owner installed compass light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, or other persons and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
Repair dead end wires that were observed under the operating station.
46CFR183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 9 September 2020
Resolution: Owner repaired dead end wires under operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 September 2020
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operation station.
Provide operable battery light at operation station.
46CFR183.430
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 9 September 2020
Resolution: Owner bought flashlight and installed at operating station.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 September 2020
Resolved
A vessel must carry adequate and up-to-date U.S. Coast Pilot and Coast Guard Light List. Extracts from these publications for the areas to be transited may be provided instead of the complete publication.
Provide adequate and up-to-date U.S Coast Pilot and Coast Guard Light List onboard the vessel.
46CFR184.420(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 9 September 2020
Resolution: Owner provided copies of Coast Pilot and Light List onboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 August 2019
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines to stop fuel flow when servicing accessories.
Inoperable fuel shutoff valve for starboard diesel propulsion engine. Repair / Replace.
IAW: 46 CFR 182.455 (b) (4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2019
Resolution: O/O repaired fuel shutoff valves, operational test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2019
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage.
Fuel filter for port generator and starboard main diesel engine were of an unapproved type. Replace with marine grade fuel filter.
IAW: 46 CFR 182.455 (b) (6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 13 August 2019
Resolution: O/O replaced unapproved fuel filter w/ RACOR marine application type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 August 2019
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe.
Sewage space bilge suction missing strainer. Repair / Replace.
IAW: 46 CFR 182.510 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 16 September 2019
Resolution: O/O installed strainer for bilge suction.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 8 August 2019
Resolved
Only one means of escape is required from a space where:
The space has a deck area less than 30 square meters (322 square feet).
Wood ladder into fore peak unsafe / broken. Repair / replace.
IAW: 46 CFR 177.500 (O) (1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O replaced broken ladder.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 August 2019
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction.
Port embarkation rail missing securing / stabilizing latch. Repair / Replace.
IAW: 46 CFR 177.900 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 13 August 2019
Resolution: O/O installed securing device on embarkation rail.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 August 2019
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10.
Portable fire extinguisher located at concession stand was not mounted. Mount in accordance with NFPA 10.
IAW: 46 CFR 176.810 (b) (1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O properly mounted portable fire extinguisher.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2019
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer.
Provide pre-employment testing results or waiver for testing for all crewmembers.
IAW: 46 CFR 16.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O produced proof of pre-employment drug testing and prior consortium enrollment waivers were applicable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2019
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06.
Alcohol test swabs were expired. Provide arrangements for post-casualty / reasonable cause testing.
IAW: 46 CFR 16.240
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O replaced expired alcohol testing devices.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2019
Resolved
Each Employee Assistance Program must include training on drug use for crewmembers and supervisory personnel.
Provide proof of training and company policy letter.
IAW: Each Employee Assistance Program must include training on drug use for crewmembers and supervisory personnel.
Provide proof of training and company policy letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O created company policy letter, and had employees in safety-sensitive positions sign a copy.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 31 August 2018
Resolved
The weather deck on a well deck vessel must be watertight.
Identified two areas in the sewage tank compartment; with fresh water intrusion in the overhead starboard fwd corner, and port aft corner. Identified one area in the engine room; with fresh water intrusion located overhead at center mast. Identify where water is leaking in and provide a plan proposal for repairs to the local Coast
Guard Marine Inspector for approval. IAW 46CFR178.430 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2018
Resolution: Vessel O/O insulated deck intrusions from seat post bolts and around center mast extending into the engine room; no sign of further water intrusion in sewage compartment or engine room
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 31 August 2018
Resolved
A hatch exposed to the weather must be watertight.
Gaskets for Sewage Compartment and Anchor Locker hatches are wasted and unserviceable. Replace. IAW 46CFR179.360 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2018
Resolution: Vessel O/O replaced wasted gaskets for sewage and anchor locker deck hatches with new gaskets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2018
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Fuel shut off valves at the tank, did not close completely when remotely operated from the weather for both ship's generator and number 1 main diesel eng. IAW 46CFR182.455 (b) (4)
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: O/O repaired the fuel shut off valves by adjusting the morse control linkages to allow proper shut off of valves.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 August 2018
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Adult and Children's life jackets located in center and starboard storage bins on the bridge were not separated. IAW 46CFR180.75 (a) (5)
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: O/O seperated both Adult and Child size lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2018
Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. Port Generator; raw water hose to and from strainer had one clamp on both ends.
Port main diesel engine; raw water hose to cooler was single-clamped. IAW 46CFR182.410 (d) (1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
Resolution: O/O installed additional hose clamps to meet the requirements.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 31 August 2018
Resolved
Footholds, handholds, ladders, and similar means provided to aid escape, must be suitable for use in
an emergency. Sewage Compartment ladder was not secured in place at lower mounting brackets. Reattach ladder lower mounting brackets. IAW 46CFR177.500(m)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2018
Resolution: Vessel O/O bolted bottom of access ladder to the sewage compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 August 2018
Resolved
Each floating electric waterlight shall meet the requirements of ANSI/UL 1196. Life Ring light battery was cracked on the bottom. Replace. IAW 46CFR161.010-2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2018
Resolution: Vessel O/O replaced water light for ring life bouy.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 31 August 2018
Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— Six hand red flare distress signals approved in accordance with 46 CFR 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and Six hand orange smoke distress signals approved in accordance with 46 CFR 160.037. Vessel had 11 flares were stored on board. Supplied additional flare to meet the requirements. IAW 46CFR180.68 (a) (1) (2)
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: O/O supplied additional flare to the required completment of 12 flares.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 August 2018
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words ‘‘FIRE BUCKET’’
must be stenciled in a contrasting color on each bucket.
In the steering compartment found Fire bucket not labeled. Labeled bucket correcting def on the spot. IAW 46CFR181.610
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: O/O corrected deficiency on the spot by labeling the fire bucket.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 August 2018
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port engine room exhaust cover was inoperable. Corrected on the spot by moving bench. IAW 46CFR182.465(h)
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: Port side bench in way of vent was moved forward and reattached to allow for install of vent cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 August 2018
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. The remote fuel shutoff stations were labeled but did not have directions labeled for proper operation. Stencil fuel shutoff valves with how to operate. IAW 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2018
Resolution: Vessel O/O installed instruction placard labeled "PULL" at remote fuel shutoff valve location.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 3 August 2017
Resolved
Pre-engineered fire extinguishing system audible alarm doesn't work, prove operation to attending marine inspector IAW 46CFR181.420(b)(2).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 9 August 2017
Resolution: Vessel representative provided prove of audible alarm in operation, deficiency corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 August 2017
Resolved
Replace un approved waterlight battery with approved one , to the satisfaction of the attending marine inspector. *Restricted to day light operation only.* 46CFR180.70(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 9 August 2017
Resolution: Vessel representative provided a new waterlight and shown proper operation, deficiency corrected.
Construction/Loadline › Hull › Transverse Frame
Issued 19 September 2016
Resolved
Crop and renew 3rd timber on deck in holding tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2017
Construction/Loadline › Hull › Transverse Frame
Issued 19 September 2016
Resolved
Crop and renew 4th timber in holding tank compartment on upper deck. 46 CFR 177.300
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2017
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 September 2016
Resolved
Crop and renew port side timber cleat midship.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2017
Lifesaving › Lifebuoys › Stowage
Issued 19 September 2016
Resolved
Correct life ring bouy set up with appropriate configuration. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2016
Resolution: Life ring configuration corrected to satisfaction of the Marine Inspector.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 September 2016
Resolved
Repair battery in smoke detector in holding tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2016
Resolution: Battery replaced in smoke detector to the satisfaction of the Marine Inspector.