MAURY USCG vessel records Sign in
← All vessels

ROYAL CONQUEST

ROYAL CONQUEST is a 1999 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1998, most recently in August 2025, along with 61 deficiencies, 2 operational controls and 2 casualty investigations between 2008 and 2015.

Records from 1998 to 2025. Most recent: inspection, 25 August 2025.

Built
1999
Last inspected
25 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM3720
495764
Flag
UNITED STATES
367567090
Maury page id
psix-495764

Inspections, by type

…with no type recorded4
Years with a record 26 calendar years (1998–2025)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.5 ft × 15.0 ft × 6.6 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNOA MARINE INC · ST PETERSBURG, FL, UNITED STATES · built 1999
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMADEIRA BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM3720MMSI 367567090 · active · compulsorily equipped · granted 19 May 2021, expires 19 May 2031
WDG7420MMSI 367567090 · cancelled · compulsorily equipped · granted 22 March 2013, cancelled 10 September 2020
WDB3286MMSI 366885410 · expired · compulsorily equipped · granted 18 March 2003, cancelled 18 May 2013
WCZ4970MMSI not assigned · expired · compulsorily equipped · granted 13 September 1999, cancelled 14 November 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 50

25 August 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8173063
18 October 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7955785
11 July 2024 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7955770
3 October 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7803038
13 September 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7808224
1 September 2023 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7762271
8 September 2022 Plan Review "T" Boat · Internal Structural Exam · Equivalency · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7511735
26 July 2022 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7510395
7 September 2021 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7178577
9 September 2020 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024046
1 September 2020 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024074
8 August 2019 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6770480
30 January 2019 Administrative Inspection · In-Service Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6616694
31 August 2018 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6515234
3 August 2017 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6154223
20 January 2017 Damage Survey · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6073870
19 September 2016 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6000575
19 December 2015 In-Service Inspection · Damage Survey · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5785545
19 December 2015 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5796639
3 September 2015 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5738431
13 August 2014 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4953920
15 May 2012 Deficiency Check · Administrative Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4319870
30 January 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4234676
31 August 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4131642
11 January 2011 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3924558
12 November 2010 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3888589
13 January 2009 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3419852
5 December 2008 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3380985
7 June 2008 Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3229566
6 June 2008 Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 3229705
6 June 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3233872
24 January 2007 Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2860916
8 November 2005 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2527689
25 January 2005 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2273515
17 December 2004 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2259170
3 November 2003 Deficiency Check · Plan Review "T" Boat · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1938331
4 September 2003 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1879774
8 January 2003 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1727259
6 January 2003 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1726538
23 August 2002 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1664233
21 February 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1489797
12 September 2001 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1439256
11 January 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 825056
5 September 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1458795
1 September 1999 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 782203
25 August 1999 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 784776
25 August 1999 Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1471566
24 August 1999 Inclining Experiment
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1406551
25 August 1998 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 798610
24 July 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1129760

Deficiency record · 61

10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 September 2020 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operation station. Except on a vessel limited to daytime operations, the compass must be illuminated. The magnetic compass does not illuminate. The vessel is restricted to daytime operations until the compass light is repaired / replaced. 46CFR184.402
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 9 September 2020
Resolution: Owner installed compass light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 September 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, or other persons and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Repair dead end wires that were observed under the operating station. 46CFR183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 9 September 2020
Resolution: Owner repaired dead end wires under operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 September 2020 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operation station. Provide operable battery light at operation station. 46CFR183.430
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 9 September 2020
Resolution: Owner bought flashlight and installed at operating station.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 September 2020 Resolved
A vessel must carry adequate and up-to-date U.S. Coast Pilot and Coast Guard Light List. Extracts from these publications for the areas to be transited may be provided instead of the complete publication. Provide adequate and up-to-date U.S Coast Pilot and Coast Guard Light List onboard the vessel. 46CFR184.420(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 9 September 2020
Resolution: Owner provided copies of Coast Pilot and Light List onboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 August 2019 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines to stop fuel flow when servicing accessories. Inoperable fuel shutoff valve for starboard diesel propulsion engine. Repair / Replace. IAW: 46 CFR 182.455 (b) (4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2019
Resolution: O/O repaired fuel shutoff valves, operational test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2019 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Fuel filter for port generator and starboard main diesel engine were of an unapproved type. Replace with marine grade fuel filter. IAW: 46 CFR 182.455 (b) (6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 13 August 2019
Resolution: O/O replaced unapproved fuel filter w/ RACOR marine application type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 August 2019 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Sewage space bilge suction missing strainer. Repair / Replace. IAW: 46 CFR 182.510 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 16 September 2019
Resolution: O/O installed strainer for bilge suction.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 8 August 2019 Resolved
Only one means of escape is required from a space where: The space has a deck area less than 30 square meters (322 square feet). Wood ladder into fore peak unsafe / broken. Repair / replace. IAW: 46 CFR 177.500 (O) (1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O replaced broken ladder.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 August 2019 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Port embarkation rail missing securing / stabilizing latch. Repair / Replace. IAW: 46 CFR 177.900 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 13 August 2019
Resolution: O/O installed securing device on embarkation rail.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 August 2019 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Portable fire extinguisher located at concession stand was not mounted. Mount in accordance with NFPA 10. IAW: 46 CFR 176.810 (b) (1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O properly mounted portable fire extinguisher.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2019 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Provide pre-employment testing results or waiver for testing for all crewmembers. IAW: 46 CFR 16.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O produced proof of pre-employment drug testing and prior consortium enrollment waivers were applicable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2019 Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. Alcohol test swabs were expired. Provide arrangements for post-casualty / reasonable cause testing. IAW: 46 CFR 16.240
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O replaced expired alcohol testing devices.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2019 Resolved
Each Employee Assistance Program must include training on drug use for crewmembers and supervisory personnel. Provide proof of training and company policy letter. IAW: Each Employee Assistance Program must include training on drug use for crewmembers and supervisory personnel. Provide proof of training and company policy letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2019
Resolved 6 September 2019
Resolution: O/O created company policy letter, and had employees in safety-sensitive positions sign a copy.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 31 August 2018 Resolved
The weather deck on a well deck vessel must be watertight. Identified two areas in the sewage tank compartment; with fresh water intrusion in the overhead starboard fwd corner, and port aft corner. Identified one area in the engine room; with fresh water intrusion located overhead at center mast. Identify where water is leaking in and provide a plan proposal for repairs to the local Coast Guard Marine Inspector for approval. IAW 46CFR178.430 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2018
Resolution: Vessel O/O insulated deck intrusions from seat post bolts and around center mast extending into the engine room; no sign of further water intrusion in sewage compartment or engine room
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 31 August 2018 Resolved
A hatch exposed to the weather must be watertight. Gaskets for Sewage Compartment and Anchor Locker hatches are wasted and unserviceable. Replace. IAW 46CFR179.360 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2018
Resolution: Vessel O/O replaced wasted gaskets for sewage and anchor locker deck hatches with new gaskets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2018 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Fuel shut off valves at the tank, did not close completely when remotely operated from the weather for both ship's generator and number 1 main diesel eng. IAW 46CFR182.455 (b) (4)
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: O/O repaired the fuel shut off valves by adjusting the morse control linkages to allow proper shut off of valves.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 August 2018 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Adult and Children's life jackets located in center and starboard storage bins on the bridge were not separated. IAW 46CFR180.75 (a) (5)
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: O/O seperated both Adult and Child size lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2018 Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. Port Generator; raw water hose to and from strainer had one clamp on both ends. Port main diesel engine; raw water hose to cooler was single-clamped. IAW 46CFR182.410 (d) (1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
Resolution: O/O installed additional hose clamps to meet the requirements.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 31 August 2018 Resolved
Footholds, handholds, ladders, and similar means provided to aid escape, must be suitable for use in an emergency. Sewage Compartment ladder was not secured in place at lower mounting brackets. Reattach ladder lower mounting brackets. IAW 46CFR177.500(m)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 October 2018
Resolution: Vessel O/O bolted bottom of access ladder to the sewage compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 August 2018 Resolved
Each floating electric waterlight shall meet the requirements of ANSI/UL 1196. Life Ring light battery was cracked on the bottom. Replace. IAW 46CFR161.010-2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2018
Resolution: Vessel O/O replaced water light for ring life bouy.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 31 August 2018 Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— Six hand red flare distress signals approved in accordance with 46 CFR 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and Six hand orange smoke distress signals approved in accordance with 46 CFR 160.037. Vessel had 11 flares were stored on board. Supplied additional flare to meet the requirements. IAW 46CFR180.68 (a) (1) (2)
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: O/O supplied additional flare to the required completment of 12 flares.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 August 2018 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words ‘‘FIRE BUCKET’’ must be stenciled in a contrasting color on each bucket. In the steering compartment found Fire bucket not labeled. Labeled bucket correcting def on the spot. IAW 46CFR181.610
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: O/O corrected deficiency on the spot by labeling the fire bucket.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 August 2018 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port engine room exhaust cover was inoperable. Corrected on the spot by moving bench. IAW 46CFR182.465(h)
Action required: 10 - Deficiency Rectified
Resolved 31 August 2018
Resolution: Port side bench in way of vent was moved forward and reattached to allow for install of vent cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 August 2018 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. The remote fuel shutoff stations were labeled but did not have directions labeled for proper operation. Stencil fuel shutoff valves with how to operate. IAW 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2018
Resolution: Vessel O/O installed instruction placard labeled "PULL" at remote fuel shutoff valve location.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 3 August 2017 Resolved
Pre-engineered fire extinguishing system audible alarm doesn't work, prove operation to attending marine inspector IAW 46CFR181.420(b)(2).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 9 August 2017
Resolution: Vessel representative provided prove of audible alarm in operation, deficiency corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 August 2017 Resolved
Replace un approved waterlight battery with approved one , to the satisfaction of the attending marine inspector. *Restricted to day light operation only.* 46CFR180.70(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 9 August 2017
Resolution: Vessel representative provided a new waterlight and shown proper operation, deficiency corrected.
Construction/Loadline › Hull › Transverse Frame
Issued 19 September 2016 Resolved
Crop and renew 3rd timber on deck in holding tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2017
Construction/Loadline › Hull › Transverse Frame
Issued 19 September 2016 Resolved
Crop and renew 4th timber in holding tank compartment on upper deck. 46 CFR 177.300
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2017
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 September 2016 Resolved
Crop and renew port side timber cleat midship.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2017
Lifesaving › Lifebuoys › Stowage
Issued 19 September 2016 Resolved
Correct life ring bouy set up with appropriate configuration. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2016
Resolution: Life ring configuration corrected to satisfaction of the Marine Inspector.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 September 2016 Resolved
Repair battery in smoke detector in holding tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2016
Resolution: Battery replaced in smoke detector to the satisfaction of the Marine Inspector.
Engineering › Bilge Water Management System › Piping
Issued 20 December 2015 Resolved
As per 46 CFR 182.500, permanently secure the bilge piping in the space aft of the collision bulkhead.
Action required: 705 - Other - as specified
Due 27 December 2015
Resolved 21 December 2015
Resolution: Piping is secured
Electrical › Lighting (service) › Lighting Fixture
Issued 20 December 2015 Resolved
As per 46 CFR 183.410 provide a globe for the light fixture in the space aft of the collision bulkhead.
Action required: 705 - Other - as specified
Due 20 December 2015
Resolved 21 December 2015
Resolution: Globe and bulb installed
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 September 2015 Resolved
REPAIR 2 HOLES THROUGH LAZERETTE WATERTIGHT BULKHEAD TO MAKE WATERTIGHT. RESTRICTED TO LAKES, BAYS AND SOUNDS ROUTE. 46CFR182.720 & 46CFR180.200(c)
Due 10 September 2015
Resolved 14 September 2015
Resolution: Repaired holes in watertight bulkhead.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 3 September 2015 Resolved
MOUNT FIRE EXTINGUISHER WITH BRACKET. 46CFR181.520
Due 10 September 2015
Resolved 14 September 2015
Resolution: FIRE EXTINGUISHER WAS MOUNTED WITH BRACKET.
Fire Fighting › Fire Bucket › Capacity
Issued 5 December 2008 Resolved
Provide three - two and a half gallon fire buckets properly marked.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 22 December 2008
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 November 2005 Resolved
Provide a copy of your consortium 2005 contract and confirmation of employee coverage as per 46CFR16.500. All employees had cards but ASAP didn't send a cover contract sheet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2005
Resolved 26 January 2006
Resolution: RCVD COPY OF CONTRACT BACK IN NOV 05. CLEARED.
Engineering › Steering Gear System › Rudder Stock
Issued 17 December 2004 Resolved
Prior to the completion of your dry dock in JAN 05', provide rudder stops IAW 46CFR182.610(e).
Condition: Placed in Improper Service
Due 31 January 2005
Resolved 31 January 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 November 2003 Resolved
Prior to the use of the new STBD GENSET, wire system, so to shut-down via the FFFFE system. LEGACY COMPONENT DESC: GENSET shut down
Condition: Placed in Improper Service
Due 10 November 2003
Resolved 6 November 2003
Operations/Management › Drills/Instruction
Issued 3 November 2003 Resolved
Label engine room emergency exit on both sides.
Condition: Improper/Lack of Maintenance
Due 10 November 2003
Resolved 6 November 2003
Engineering › Bilge Water Management System
Issued 3 November 2003 Resolved
Provide an audible alarm for your high bilge level alarm system. LEGACY COMPONENT DESC: Alarm
Condition: Improper/Lack of Maintenance
Due 10 November 2003
Resolved 6 November 2003
Engineering › Electric Propulsion System
Issued 23 August 2002 Resolved
Provide a flame bowl for GENSET fuel oil strainer. LEGACY COMPONENT DESC: Fuel Oil Strainer
Due 29 August 2002
Resolved 7 January 2003
Operations/Management › Drills/Instruction
Issued 23 August 2002 Resolved
Adjust emergency instructions to fit vessel layout.
Due 29 August 2002
Resolved 7 January 2003
Communications › Radio Communications
Issued 23 August 2002 Resolved
Provide an FCC Safety Certificate for vessel. LEGACY COMPONENT DESC: FCC Safety Certificate
Due 23 September 2002
Resolved 7 January 2003
Lifesaving
Issued 12 September 2001 Resolved
REPLACE RETRO ON LIFERING.
Condition: Unknown
Due 20 October 2001
Resolved 21 February 2002
Fire Fighting
Issued 12 September 2001 Resolved
CONDUCT ANNUAL SERVICING OF FIXED FIRE SYSTEM PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 20 October 2001
Resolved 21 February 2002
Resolution: SERVICED
Fire Fighting
Issued 12 September 2001 Resolved
ADJUST PORT VENT CLOSURE.
Condition: Unknown
Due 20 October 2001
Resolved 21 February 2002
Resolution: ADJUSTED.
Fire Fighting
Issued 12 September 2001 Resolved
CONDUCT ANNUAL SERVICING OF PORTABLE FIRE EXTINGUISHERS PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 20 October 2001
Resolved 21 February 2002
Resolution: SERVICED
Lifesaving
Issued 12 September 2001 Resolved
REPLACE/REPAIR FLOATING WATERLIGHT AND LANYARD PRIOR TO OPERATION AT NIGHT.
Condition: Unknown
Due 20 October 2001
Resolved 21 February 2002
Fire Fighting
Issued 5 September 2000 Resolved
CONDUCT ANNUAL SERVICING OF FIXED FIREFIGHTING SYSTEM PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 12 September 2000
Resolved 13 September 2000
Lifesaving
Issued 5 September 2000 Resolved
PROVIDE 6 RED AND 6 ORANGE HAND HELD FLARES OR 12 RED HAND HELD FLARES IN WEATHERTIGHT BOX PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 12 September 2000
Resolved 13 September 2000
Electrical
Issued 5 September 2000 Resolved
PLACE BATTERIES IN APPROVED BATTERY CONTAINMENT.
Condition: Unknown
Due 5 October 2000
Resolved 20 September 2000
Documentation
Issued 5 September 2000 Resolved
PROCURE RADIOTELEPHONE SAFETY CERTIFICATE.
Condition: Unknown
Due 5 September 2000
Resolved 5 September 2000
Construction/Loadline
Issued 5 September 2000 Resolved
INSTALL CAPTIVE CHAINS ON EACH FLUSH DECK HATCH.
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Fire Fighting
Issued 5 September 2000 Resolved
INSTALL UL-217 SMOKE DETECTORS IN EACH COMPARTMENT WITH IGNITION SOURCE.
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Fire Fighting
Issued 5 September 2000 Resolved
AT THE OPERATING STATION, PROVIDE MEANS TO RESET USED TO AUTOMATICALLY SHUTDOWN VENTILLATION SYSTEMS AND ENGINES.
Condition: Unknown
Due 5 September 2000
Resolved 5 September 2000
Lifesaving
Issued 5 September 2000 Resolved
PROVIDE AID IN RETRIEVING HELPLESS PERSON FROM THE WATER AND DEMONSTRATE TOTHE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Documentation
Issued 25 August 1999 Resolved
POST VESSEL DOCUMENT, MASTER'S LICENSE, AND CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 1 September 1999
Resolved 8 September 1999
Lifesaving
Issued 25 August 1999 Resolved
MODIFY MOB RECOVERY LADDER FOR EASE OF INSTALLATION AT EMBARKATION STATION.
Condition: Unknown
Due 1 September 1999
Resolved 8 September 1999
Lifesaving
Issued 25 August 1999 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS REMOVE COMBUSTIBLE/FLAMMABLE LIQUIDS FROM STORAGE SPACE.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Documentation
Issued 25 August 1999 Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE, STATION LICENSE, AND OPERATOR'S PERMIT. VSL RESTRICTED TO NO MORE THAN 1000' FROM SHORE PENDING PROVISION OF SAME.
Condition: Unknown
Due 1 September 1999
Resolved 8 September 1999

Casualty record · 2

6 June 2008Routine · role: Involved in a Marine Casualty · activity 3233872
19 December 2015Routine · role: Involved in a Marine Casualty · activity 5796639
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.