MAURY USCG vessel records Sign in
← All vessels

MISS ASHLEY

MISS ASHLEY is a 1944 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 1999, most recently in April 2026, along with 100 deficiencies.

Records from 1999 to 2026. Most recent: inspection, 27 April 2026.

Built
1944
Last inspected
27 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

495785
Flag
UNITED STATES
—
Maury page id
psix-495785

Inspections, by type

…with no type recorded2
Years with a record 23 calendar years (1999–2026)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

27 April 2026 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8361662
17 April 2025 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8113991
20 February 2024 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7879125
10 January 2024 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7848770
11 January 2023 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7624420
26 January 2022 Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7391916
5 March 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7150997
15 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002637
26 March 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660492
24 October 2018 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6580069
25 July 2018 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507213
31 January 2018 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6348417
24 January 2017 COI Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6077192
11 February 2016 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5814451
2 February 2016 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5812884
17 February 2012 Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4246191
14 December 2009 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3650058
9 April 2009 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3451603
3 March 2009 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3430879
14 February 2008 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3148044
6 February 2008 Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3144050
20 February 2007 COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2875250
2 March 2006 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2594840
1 March 2005 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2301262
23 March 2004 Hull Examination · Periodic Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2034188
7 May 2003 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 1788610
17 March 2003 Periodic Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 1736906
3 April 2002 Deficiency Check · Administrative Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1601152
20 February 2002 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1494539
1 August 2001 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1069067
12 June 2001 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1067916
24 April 2001 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1063310
27 March 2001 Hull Examination · Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1458855
14 July 2000 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 214156
9 March 2000 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1050835
9 March 2000 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1452645
13 October 1999 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 786993
15 July 1999 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 213363
19 May 1999 Hull Examination · Initial Certification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1375799

Deficiency record · 100

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2024 Resolved
The Vessel is required to process sistering information to Marine Safety Center(MSC) and get a stability letter prior to operating with full COI passenger count. The vessel is restricted to the carriage of 26 passengers and 1 crew member until the stability test process is completed and approved. Complete prior to August 30th 2024.
Action required: 705 - Other - as specified
Due 10 March 2024
Resolved 10 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024 Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2024
Resolution: Vessel met NDA requirements, But waiting on Stability information from Sister vessel. See new deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 January 2023 Resolved
Vessel missing 04 of the required XX Adult PFDs. Owner/Operator shall insure that the PFDs onboard the vessel meets or exceeds the amount on the COI for the Safety of passengers on board.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 January 2023
Resolved 11 January 2023
Resolution: Vessel owner provided photos of 04 New PFD's prior to arriving back to the unit. Vessel Owner was notified of the def and rectified immediatly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2022 Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergenceny fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 30 March 2022
Resolved 24 March 2022
Resolution: Vessel owner installed valve to show the fuel valve is open or shut.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 January 2022 Resolved
Fire Fighting equipment sevicing is expired. All fighting equipment shall be serviced annually. Provided servicing documentation prior to embarking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2022
Resolution: Vessel had Fighter extingishers inspected and approved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 January 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 January 2022 Resolved
roperly mark and stow PFD's in the correct vessel. Adult PFD's and Child PFD's shall be stowed and marked in the proper locations.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 24 March 2022
Resolution: Vessels Owner properly marked and stowed PFD's on board the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 January 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021 Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: COI installed in lockbox on vessel due to open vessel design.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 March 2021 Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid stability letter on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: Stability Letter is onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Child sized life jackets are stowed separately.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021 Resolved
All electrical equipment and circuits must be clearly marked and identified. The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: NAV lights clearly marked.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2021 Resolved
A vessel must carry a first aid kit approved under 160.041 or an equivalent kit, must be easily visible and readily available to the crew. The kit on board was expired.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Installed new First aid kits
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2021 Resolved
Each life ring on a vessel must be approved under 160.050, be readily accessible, be stowed in a way that it can be rapidly cast loose, and not permanently secured in anyway. The life ring w/ line was not stowed in a fashion that allowed for it to be rapidly cast loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Lifebuoy able to be rapidly cast loose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2021 Resolved
Remote fuel shutoff valves must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operation. Fuel shut off valve either not labeled or not fully visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Labeled fuel shut off valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessels name. Multiple life jackets found without vessel name.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Replaced lifejackets
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 March 2021 Resolved
At each inspection and subsequent inspection the owner operator shall be prepared to conduct testing of machinery alarms, including bilge high level alarms. The AFT bilge alarm on STBD side was inop.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Replaced bilge alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2020 Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 July 2020 Resolved
Clean bilge of all debris and oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 March 2019 Resolved
Coaming around engine compartment weather-tight opening wasted and dented.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 26 March 2019
Resolution: Coaming repaired to the satisfaction of the attending MI.
Construction/Loadline › Structures › Deck Plating
Issued 2 February 2017 Resolved
Found crack in the structural framing that holds deck plate. Weld frame.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2017
Resolved 8 March 2017
Resolution: Frame was welded and inspected.
Personnel › Training › Passenger Safety
Issued 24 January 2017 Resolved
Crew training has not been conducted since last summer (AUG 16). Training for emergency procedures shall be conducted every three months. Conduct training prior to getting underway with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2017
Resolved 2 February 2017
Resolution: Drills were completed.
Communications › Alarms/Indicators › High Water Alarm
Issued 24 January 2017 Resolved
The visual indicator (light) was not working on STBD AFT high level alarm. Fix/replace light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: Light was fixed on high level alarm.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 January 2017 Resolved
Management Information System (MIS) Data Reporting has not been completed for 2016. Submit form U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form to Commandant (CG-INV) by March 15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 8 March 2017
Resolution: MIS reports were submitted.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 February 2016 Resolved
Vessel is required to have 30 adult and 03 child lifejackets. Vessel currently has 16 adult and 00 child satisfactory lifejackets. Provide required lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 11 February 2016
Resolution: Lifejackets were replaced.
Lifesaving › Lifebuoys › Approval
Issued 2 February 2016 Resolved
Found that the lifebuoy onboard was marked with "DOT" approved retro reflective tape. Replace with "SOLAS" approved tape (Tape II) IAW 46 CFR 164.018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 11 February 2016
Resolution: Lifebuoy was properly marked with SOLAS approved tape.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 1 March 2012 Resolved
Fixed fire extinguishing bottles were past the inspection date. Prior to carrying passengers, service fixed firefighting bottles in engine compartment and aft compartment.
Action required: 705 - Other - as specified
Due 1 April 2012
Resolved 4 April 2012
Resolution: Fixed fire fighting bottles have been serviced.
Documentation › Certificates/Documents › Stability Letter
Issued 17 February 2012 Resolved
Stability letter denotes 30 passengers allowed, where as COI denotes 31 persons allowed. Until the issue is resolved or a new COI issued, a CG-835 will be issued limiting the number of passengers to 29, making total number of persons allowed 30.
Action required: 705 - Other - as specified
Due 17 April 2012
Resolved 1 March 2012
Resolution: COI now states 29 passengers or 30 total persons allowed.
Construction/Loadline › Markings › Load Line Mark
Issued 3 March 2009 Resolved
Freeboard load line not marked on the hull of the vessel
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Fire Fighting › Fire Bucket › Stenciling
Issued 3 March 2009 Resolved
Fire buckets not stenciled
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 March 2009 Resolved
Children lifejacket stowed location not appropriately marked as 46 CFR 180.78 (a) (5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2009
Engineering › Bilge Water Management System › Piping
Issued 3 March 2009 Resolved
Secure bilge pump discharge hose with metal brackets
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Engineering › Gasoline Engine (propulsion) › Exhaust Outlet (2 stroke)
Issued 3 March 2009 Resolved
Exhaust guards not mounted
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Construction/Loadline › Hull › Weld
Issued 3 March 2009 Resolved
Fore and aft carrier bearing plates with excessive weld material. Grind and re-weld
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Resolution: water tested-all sat
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 3 March 2009 Resolved
Shaft and rudder seals leaking excessively.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Resolution: Water tested- all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2009 Resolved
Throughout the vessel, plastic straps were used to attach wires to the vessel's hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2009
Resolved 9 April 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009 Resolved
Portside vent closure (engine compartment) not working properly.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2009
Resolved 11 March 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009 Resolved
Fire wall needs to extend down to the hull in order to create a segregated engine compartment for fire fighting purposes.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009 Resolved
Segregate fuel tank compartment to ensure efficiency of fixed fire protection system
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2008 Resolved
Electrical wires in aft bilge are mounted too low and they are attached to the rudder shaft. Wires need to be mounted as high as practical in order to ensure longevity and proper function.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 February 2008
Resolved 14 February 2008
Resolution: Wires mounted as high as practical.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 February 2008 Resolved
Aft fuel shut off valve not labeled. Fuel shut off valve needs to be marked with name and directions showing which way is on and off.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 February 2008
Resolved 14 February 2008
Resolution: Fuel shut off valve labeled with direction for on and off.
Engineering › Bilge Water Management System › Pump
Issued 6 February 2008 Resolved
The drive chain for the Higgins Pump is loose. This condition could damage the hull and create a casualty. The chain needs to be tightened to that no slack is apparent.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2008
Resolution: Drive chain tightened. No slack apparent.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 February 2008 Resolved
The second seat back on the starboard side is missing two floor mounting bolts. Replace bolts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2008
Resolved 14 February 2008
Resolution: Bolts replaced, seat is firmly mounted.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 February 2008 Resolved
The second seat back on the starboard side is missing two floor mounting bolts. Replace bolts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2008
Resolved 14 February 2008
Resolution: Bolts replaced, seat is firmly mounted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 6 March 2007 Resolved
Provide B-1 extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 6 March 2007 Resolved
Properly install ground lead to engine coolent fan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2007
Engineering › Steering Gear System › Rudder
Issued 6 March 2007 Resolved
Tighten or replace packing fo the rudder shaft seal.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 6 August 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 March 2007 Resolved
Provide approved first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 6 March 2007 Resolved
Remove all cables not in service. All cable connections and cables are to be installed as per 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 6 August 2007
Stability › Watertight Integrity › Coaming
Issued 6 March 2007 Resolved
Vessel is required to extend the watertight coaming around the aft deck area. The coaming is to be watertight to a height of 12" above the after deck.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 6 August 2007
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 8 March 2006 Resolved
Need to add additional adult life jacket to operate w/33 persons onboard. Limit to 32 adults in total.
Action required: 705 - Other - as specified
Resolved 15 March 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 March 2006 Resolved
Mount cable as to not interfere with the steering cable.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 15 March 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 March 2005 Resolved
Install lock washers on retaining bracket. NVIC 01-01. Prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 March 2005 Resolved
Add three adult life jackets to the vsl as per 46 CFR 180.71. Prior to carrying Passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Engineering › Bilge Water Management System › Pump
Issued 8 March 2005 Resolved
Repair and make operable the FWD electric bilge pump. 46 CFR 176.804(h). Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 March 2005 Resolved
Provide proof of annual service on all vsl portable fire extinguishers IAW 46 CFR 176.810(b)(1). Prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 March 2005 Resolved
Provide proof of annual service on vsl's fixed fire extinguisher IAW 46 CFR 176.810(b)(1). Prior to 08 Apr 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 5 May 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2005 Resolved
Make repairs and/or alterations to firewall so that it is MORE vapor tight. NVIC 01-01 enclosure 1 page 27. Prior to 08 APR 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Documentation › Markings/Placards › Garbage Placard
Issued 8 March 2005 Resolved
Post MARPOL Placard. IAW 33 CFR 151.59 (a)(I). Prior to 08 Apr 2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 March 2005
Resolved 5 May 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 8 March 2005 Resolved
Post oil pollution placard at each bilge control station. IAW 33 CFR 155.450. Prior to 08 Apr 2004.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 5 May 2005
Documentation › Logs/Records
Issued 23 March 2004 Resolved
Provide vessel's name on passenger count log. LEGACY COMPONENT DESC: Logbook (official)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2004
Resolution: Vessel''s name provided on passenger count log.
Documentation › Markings/Placards
Issued 23 March 2004 Resolved
Provide and post lifejacket donning instructions. LEGACY COMPONENT DESC: Lifejacket Donning Instructions
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2004
Resolution: Posted lifejacket donning instructions.
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Make repairs to the vapor barrier in the engine space. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2004
Resolution: Repairs effected to vapor barrier in the engine space.
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Make the fuel tank space vapor tight. LEGACY COMPONENT DESC: Machinery Space Opening
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Fuel tank space made vapor tight.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 23 March 2004 Resolved
Provide evidence of 50% First Aid and CPR card. LEGACY COMPONENT DESC: First Aid
Due 1 June 2004
Resolved 1 June 2005
Personnel › Certificates/Documents/Licenses
Issued 23 March 2004 Resolved
Provide copies of the Master's License for review. LEGACY COMPONENT DESC: License, Master
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 24 March 2004
Resolution: Copies of Master''''''''s License provided for review.
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 March 2004 Resolved
Provide on board a USCG approved First Aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Approved First Aid kit provided on board.
Documentation › Markings/Placards
Issued 23 March 2004 Resolved
Post emergency procedures. LEGACY COMPONENT DESC: Emergency Procedures
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2004
Resolution: Emergency Procedures posted.
Documentation › Markings/Placards
Issued 23 March 2004 Resolved
Mark the hull with vessel's name. LEGACY COMPONENT DESC: Vessel Name
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Hull marked with vessel''s name.
Documentation › Markings/Placards
Issued 23 March 2004 Resolved
Mark the vessel's stern with the minimum freeboard mark. LEGACY COMPONENT DESC: Freeboard Mark
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2004
Resolution: Stern marked with minimum freeboard mark.
Electrical › Electric Supply System (service)
Issued 23 March 2004 Resolved
Secure the battery and provide a corrosion resistant battery box. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Battery secured within a corrosion resistant battery box.
Documentation › Manuals/Policy Documentation
Issued 23 March 2004 Resolved
Provide Operations Manual for review. LEGACY COMPONENT DESC: Operations Manual
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 24 March 2004
Resolution: Operations Manual provided for review.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 23 March 2004 Resolved
Provide an operational pre-engineered fire suppression system in the engine space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2004
Resolution: New Bottle Installed.
Documentation › Manuals/Policy Documentation
Issued 22 March 2004 Resolved
Provide Emergency Reponse Manual for review. LEGACY COMPONENT DESC: Emergency Reponse Manual
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 24 March 2004
Resolution: Emergency Reponse Manual provided for review.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 March 2003 Resolved
Maintain fixed fire extinguishers semi annualy IAW manufacturers instructions.
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: All extinguishers inspected and tagged.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 17 March 2003 Resolved
Properly mount aft portable fire extinguisher. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: Aft portable extinguisher properly mounted.
Operations/Management › Drills/Instruction
Issued 20 February 2002 Resolved
Provide and post Emergency Instructions IAW 46 CFR 185.510. LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Due 20 March 2002
Resolved 19 March 2002
Resolution: Posted instructions reviewed.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 20 February 2002 Resolved
Prior to placing vehicle into service, remove the safety pin for the engine compartment and the fuel tank compartment fixed fire extinguishing cylinder head. LEGACY COMPONENT DESC: Control Valve
Condition: Improper Installation
Due 20 March 2002
Resolved 19 March 2002
Resolution: Both safety pins were removed.
Engineering › Fuel Oil Service System
Issued 20 February 2002 Resolved
Replace flexible fuel with the SAE J-1492 hose. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 10 April 2002
Resolved 10 April 2002
Resolution: MSO Memphis received a letter dated 4/15/2002 and signed by the owner/operator stating that the fuel line has been changed on 4/10/2002.
Electrical › Electric Supply System (service)
Issued 20 February 2002 Resolved
Provide and install a battery box that is corrosion resistant. LEGACY COMPONENT DESC: Battery Installation
Condition: Design Flaw
Due 20 March 2002
Resolved 19 March 2002
Resolution: A battery box has been installed.
Construction/Loadline › Markings
Issued 20 February 2002 Resolved
Provide a permanent and painted mark indicating the 15.5 inches minimum freeboard at the vehicle's stern. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Due 20 March 2002
Resolved 19 March 2002
Resolution: A permanent and painted mark has been provided.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 20 February 2002 Resolved
Install a vapor barrier between the engine compartment and the area under the passenger seating. The engine compartment area is not to exceed 125 cubic feet. LEGACY COMPONENT DESC: Quantity of Gas
Condition: Design Flaw
Due 20 March 2002
Resolved 19 March 2002
Resolution: A vapor barrier has been fitted.
Documentation › Manuals/Policy Documentation
Issued 24 April 2001 Resolved
Provide for USCG review, a company operations manual.
Condition: Improper/Lack of Maintenance
Due 31 August 2001
Resolved 20 February 2002
Engineering
Issued 27 March 2001 Resolved
PROVIDE VALVES/PIPING FOR KEEL COOLER.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Fire Fighting › Miscellaneous Items
Issued 27 March 2001 Resolved
SUBMIT WRITTEN PROPOSAL FOR INSTALLATION OF PRE-ENGINEERED FIRE FIGHTING SYSTEM.
Due 31 December 2001
Resolved 20 February 2002
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 March 2001 Resolved
PROVIDE AFT FUEL COMPT FUEL SHUTOFF VALVE.
Condition: Design Flaw
Due 31 August 2001
Resolved 20 February 2002
Lifesaving
Issued 27 March 2001 Resolved
IN ACCORDANCE WITH 46 CFR 185.516(a) POST THE LIFEJACKET DONNING INSTRUCTIONS IN A CONSPICUOUS LOCATION.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001 Resolved
PROVIDE AND INSTALL THREE HINGE CAP SCREWS FOR EACH SHAFT HOUSING HINGE ASSEMBLY. CURRENTLY EACH HINGE ASSEMBLY HAS TWO CAP SCREWS (ONE BOTTOM, ONE SIDE) AND THE SHAFT HOUSINGS ONLY HAVE TWO CAP SCREW ANCHORING POINTS.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Fire Fighting
Issued 27 March 2001 Resolved
PROVIDE AND INSTALL A BRACKET FOR THE AFT PORTABLE FIRE EXTINGUSIHER.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Fire Fighting
Issued 27 March 2001 Resolved
PROVIDE AND POST OPERATING INSTRUCTIONS FOR THE INSTALLED FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 27 March 2001 Resolved
PROVIDE A PERMANENT (WELDED BEAD OR PUNCHED MARK) AND PAINTED MARK INDICATING MINIMUM FREEBOARD AT VESSEL'S STERN.
Condition: Improper/Lack of Maintenance
Due 31 December 2001
Resolved 20 February 2002
Construction/Loadline › Structures › Machinery Space Opening
Issued 27 March 2001 Resolved
INSTALL A MECHANISUM THAT WILL PERMIT THE OPERATOR TO SECURE THE ENGINE COMPARTMENT HATCH COVER.
Condition: Design Flaw
Due 31 December 2001
Resolved 20 February 2002
Construction/Loadline
Issued 27 March 2001 Resolved
BEND RAIN FLAPS P/S FOR MINIMUM 32" EGRESS CLEARANCE.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Lifesaving
Issued 9 March 2000 Resolved
Post emergency instructions as per 46 CFR 185.510.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 9 March 2000 Resolved
Put vessel name on 11 adult and 7 child lifejackets.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Fire Fighting
Issued 9 March 2000 Resolved
Provide proof of annual servicing of fixed CO2 system.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Fire Fighting
Issued 9 March 2000 Resolved
Install center discharge pipe on fixed CO2 system to engineroom prior to carrying passengers.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Fire Fighting
Issued 9 March 2000 Resolved
Replace inboard discharge pipe on fixed CO2 system prior to carrying passengers.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 9 March 2000 Resolved
Put vessel name and reflective tape on lifering.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Fire Fighting
Issued 19 May 1999 Resolved
INSTALL FLAMMABLE VAPOR DETECTION SYSTEM.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.