Records from 2016 to 2026. Most recent: inspection, 27 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 15
27 April 2026
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8361662
17 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8113991
20 February 2024
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7879125
10 January 2024
Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7848770
11 January 2023
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7624420
26 January 2022
Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7391916
5 March 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7150997
15 July 2020
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002637
26 March 2019
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660492
24 October 2018
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6580069
25 July 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507213
31 January 2018
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6348417
24 January 2017
COI Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6077192
11 February 2016
Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5814451
2 February 2016
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5812884
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2024
Resolved
The Vessel is required to process sistering information to Marine Safety Center(MSC) and get a stability letter prior to operating with full COI passenger count. The vessel is restricted to the carriage of 26 passengers and 1 crew member until the stability test process is completed and approved. Complete prior to August 30th 2024.
Action required: 705 - Other - as specified
Due 10 March 2024
Resolved 10 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024
Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2024
Resolution: Vessel met NDA requirements, But waiting on Stability information from Sister vessel. See new deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 January 2023
Resolved
Vessel missing 04 of the required XX Adult PFDs. Owner/Operator shall insure that the PFDs onboard the vessel meets or exceeds the amount on the COI for the Safety of passengers on board.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 January 2023
Resolved 11 January 2023
Resolution: Vessel owner provided photos of 04 New PFD's prior to arriving back to the unit. Vessel Owner was notified of the def and rectified immediatly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2022
Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergenceny fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 30 March 2022
Resolved 24 March 2022
Resolution: Vessel owner installed valve to show the fuel valve is open or shut.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 January 2022
Resolved
Fire Fighting equipment sevicing is expired. All fighting equipment shall be serviced annually. Provided servicing documentation prior to embarking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2022
Resolution: Vessel had Fighter extingishers inspected and approved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 January 2022
Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 January 2022
Resolved
roperly mark and stow PFD's in the correct vessel. Adult PFD's and Child PFD's shall be stowed and marked in the proper locations.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 24 March 2022
Resolution: Vessels Owner properly marked and stowed PFD's on board the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 January 2022
Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021
Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: COI installed in lockbox on vessel due to open vessel design.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 March 2021
Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid stability letter on
board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: Stability Letter is onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021
Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Child sized life jackets are stowed separately.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021
Resolved
All electrical equipment and circuits must be clearly marked and identified.
The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: NAV lights clearly marked.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2021
Resolved
A vessel must carry a first aid kit approved under 160.041 or an equivalent kit, must be easily visible and readily available to the crew.
The kit on board was expired.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Installed new First aid kits
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2021
Resolved
Each life ring on a vessel must be approved under 160.050, be readily accessible, be stowed in a way that it can be rapidly cast loose, and not permanently secured in anyway.
The life ring w/ line was not stowed in a fashion that allowed for it to be rapidly cast loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Lifebuoy able to be rapidly cast loose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2021
Resolved
Remote fuel shutoff valves must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operation.
Fuel shut off valve either not labeled or not fully
visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Labeled fuel shut off valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessels name.
Multiple life jackets found without vessel name.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Replaced lifejackets
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 March 2021
Resolved
At each inspection and subsequent inspection the owner operator shall be prepared to conduct testing of machinery alarms, including bilge high level alarms.
The AFT bilge alarm on STBD side was inop.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Replaced bilge alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2020
Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 July 2020
Resolved
Clean bilge of all debris and oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 March 2019
Resolved
Coaming around engine compartment weather-tight opening wasted and dented.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 26 March 2019
Resolution: Coaming repaired to the satisfaction of the attending MI.
Construction/Loadline › Structures › Deck Plating
Issued 2 February 2017
Resolved
Found crack in the structural framing that holds deck plate. Weld frame.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2017
Resolved 8 March 2017
Resolution: Frame was welded and inspected.
Personnel › Training › Passenger Safety
Issued 24 January 2017
Resolved
Crew training has not been conducted since last summer (AUG 16). Training for emergency procedures shall be conducted every three months. Conduct training prior to getting underway with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2017
Resolved 2 February 2017
Resolution: Drills were completed.
Communications › Alarms/Indicators › High Water Alarm
Issued 24 January 2017
Resolved
The visual indicator (light) was not working on STBD AFT high level alarm. Fix/replace light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: Light was fixed on high level alarm.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 January 2017
Resolved
Management Information System (MIS) Data Reporting has not been completed for 2016. Submit form U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form to Commandant (CG-INV) by March 15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 8 March 2017
Resolution: MIS reports were submitted.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 February 2016
Resolved
Vessel is required to have 30 adult and 03 child lifejackets. Vessel currently has 16 adult and 00 child satisfactory lifejackets. Provide required lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 11 February 2016
Resolution: Lifejackets were replaced.
Lifesaving › Lifebuoys › Approval
Issued 2 February 2016
Resolved
Found that the lifebuoy onboard was marked with "DOT" approved retro reflective tape. Replace with "SOLAS" approved tape (Tape II) IAW 46 CFR 164.018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 11 February 2016
Resolution: Lifebuoy was properly marked with SOLAS approved tape.