CAREFREE LEARNER

CAREFREE LEARNER is a 1978 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1985, most recently in May 2025, along with 96 deficiencies and 1 casualty investigation in 2010.

Records from 1985 to 2025. Most recent: inspection, 13 May 2025.

Built
1978
Last inspected
13 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-49584

Inspections, by type

…with no type recorded5
Years with a record 38 calendar years (1985–2025)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.2 ft × 13.2 ft × 2.0 ft
Registered tonnagegross 10 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMICHAEL B STUART · SARASOTA, FL, UNITED STATES · built 1978
Hull materialWood
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSARASOTA, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBQ9249MMSI not assigned · expired · compulsorily equipped · granted 9 January 1998, cancelled 26 April 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 78

13 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8104759
8 August 2024 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7971317
13 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7899528
3 November 2023 Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7823927
12 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7619121
9 June 2022 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7444626
16 February 2022 COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7379467
26 April 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7182977
2 June 2020 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6942820
18 May 2020 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6942803
15 May 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6676302
2 July 2018 Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6450110
3 May 2018 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6374486
21 April 2017 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6271446
23 January 2017 Deficiency Check · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6075116
10 June 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5906331
12 May 2016 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5872792
3 June 2014 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4877970
27 February 2012 COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4252153
8 November 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3887397
8 November 2010 Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3887692
11 February 2010 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3678476
11 February 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3692315
20 January 2009 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3397100
17 July 2008 Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3271088
21 May 2008 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3212496
25 February 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3152866
26 February 2007 Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2877577
22 May 2006 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2655272
6 March 2006 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2596290
7 March 2005 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2302290
4 June 2004 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2085922
11 March 2004 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2022153
14 April 2003 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1774279
21 March 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1758483
19 July 2002 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1647888
5 March 2002 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1489504
5 March 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1059096
5 February 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460495
11 August 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1462878
6 March 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1047106
31 January 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460394
10 February 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399042
29 June 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1128690
17 February 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1113445
10 March 1997 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1099386
13 February 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424334
12 September 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1388140
1 March 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1371344
25 August 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1192474
18 January 1995 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1140320
6 September 1994 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 867121
29 April 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 859195
3 February 1994 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1164756
19 January 1994 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1161734
21 July 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1152848
5 March 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 837839
28 July 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1268625
11 March 1992 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257379
8 August 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1255578
4 March 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1233121
29 January 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1229629
1 October 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1237401
21 August 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1240321
21 May 1990 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1212172
11 April 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1224200
7 March 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 916596
23 August 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 896202
14 March 1989 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1204394
22 August 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1347948
21 July 1988 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1340911
25 May 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351703
5 April 1988 Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1036464
23 June 1987 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1008567
26 March 1987 COI Inspection · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1018773
2 April 1986 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 998478
22 August 1985 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 986157
22 March 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 981985

Deficiency record · 96

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2025 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. MI observed no proof of annual inspections conducted or logs maintained as required. 46 CFR 176.810(b)(1); 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 23 May 2025
Resolution: Extinguishers have been inspected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2025 Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by table 1 to § 181.500(b). MI observed portable fire extinguisher missing. 46 CFR 181.500(a);701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 23 May 2025
Resolution: 03 Fire extinguishers are onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2025 Resolved
A vessel must have at least three 2.5 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI observed 01 Fire Bucket missing. 46 CFR 181.610; 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 23 May 2025
Resolution: Fire bucket was purchased and placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed Ring Life Buoy grab line, life line, and retro-reflective tape not in serviceable condition. Required to replace. 46 CFR 176.808(b); 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 23 May 2025
Resolution: New life ring was onbaord.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2025 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. MI observed last drill recorded on 08MAY2023. Master shall log all drills. 49 CFR 185.520; 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 23 May 2025
Resolution: Drills were completed and logged.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 May 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. MI observed 02 portable lights not present. 46 CFR 183.430; 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 23 May 2025
Resolution: 02 portable lights were onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2025 Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required. MI observed missing hose clamp on Forward Bilge pump. 46 CFR 182.410; 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 23 May 2025
Resolution: Hose clamp was installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed port side light not operational. Restricted to daylight and fair weather operations. 46 CFR 183.420; 705c
Action required: 705 - Other - as specified
Due 13 May 2025
Resolved 23 May 2025
Resolution: Nav lights were repaired and are operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2024 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Vessel's three portable fire extinguishers were past due for annual servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2024
Resolved 14 May 2024
Resolution: Fire extinguishers were serviced by All Florida Fire and Equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2024 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel only had three red flares on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 30 May 2024
Resolution: Three new orange flares were added to the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 November 2023 Resolved
On passenger decks of vessels engaged in excursion type operation, rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. Space below vessel's rails only have two cables used as the rail courses. There's an approx. 12 distance between the rails. Vessel requires additional safety under the rails as stated above or may use current regulations and add rail courses at no more than 4 inches between each course. The addition of one of the above options is to be completed at next dry-dock. 46 CFR 177.35(c) "OLD T"
Action required: 705 - Other - as specified
Due 31 July 2024
Resolved 1 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 May 2023 Resolved
Placards containing instructions for the donning and use of the lifejackets aboard must be posted in conspicuous places that are regularly accessible an visible to the crew and passengers. MI identified that their were two different lifejacket styles onboard with different ways to secure after donning. Two different donning placards shall be posted for the two different styles of lifejackets. 46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 17 May 2023
Resolution: Received photo for the new life jacket donning placard.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 6 May 2021 Resolved
04108 - The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. MI noted vessel did not have emergency instructions drafted. Vessel representative confirmed vessel did not have written procedures. - 46 CFR 185.510(a) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 18 May 2021
Resolution: Vessel wrote and posted emergency procedures for person overboard, fire at sea, and hazardous weather/low visibility.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2021 Resolved
11117 - At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must be of at least 18.3 meters (60 feet) in length. Life buoy lifeline was only 20 feet long. - 46 CFR 180.70(c) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 18 May 2021
Resolution: Vessel replaced lifeline with 60 foot long line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2021 Resolved
11118 - Each life jacket must be approved in accordance with either §160.002, §160.005, or §160.055 in subchapter Q of this chapter. Life jackets were worn, torn, and retroreflective material was no longer reflective. Vessel is limited to 28 passengers until corrected. - 46 CFR 180.71(c) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 18 May 2021
Resolution: Vessel replaced 08 lifejackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2021 Resolved
07110 - Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. MI witnessed owner change under-pressured portable fire extinguisher. - 46 CFR 176.810(b)(1) - 10C
Action required: 10 - Deficiency Rectified
Due 20 May 2021
Resolved 6 May 2021
Resolution: Owner replaced under-pressured portable fire extinguisher.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 2 June 2020 Resolved
46CFR176.25-1 Vessel shall be inspected for compliance with the standards required. Submit repair proposal to grind back and make permanent repairs to rotted plywood deck starboard side forward compartment.
Action required: 705 - Other - as specified
Resolved 9 November 2020
Resolution: Repairs made to deck.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 June 2020 Resolved
46CFR176.25-1 Vessel shall be inspected for compliance with the standards required. Replace corroded stanchion on stern port of engine.
Action required: 705 - Other - as specified
Resolved 9 November 2020
Resolution: Stanchion and base replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 2 June 2020 Resolved
46CFR176.25-1 Vessel shall be inspected for compliance with the standards required. Submit repair proposal to grind back and make permanent repairs to rotted plywood skid on starboard hull.
Action required: 705 - Other - as specified
Resolved 9 November 2020
Resolution: Skid ground back and repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2020 Resolved
46CFR176.810(b)(1)(iv) The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. All portable fire extinguishers on board are past annual servicing date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2020
Resolution: Operator had all fire extinguishers on board serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2020 Resolved
46 CFR 185.604(b) Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name and retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 22 May 2020
Resolution: Operator installed new sericeable life ring meeting requirements.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 2 July 2018 Resolved
Vessel shall be inspected for compliance with the standards required. Grind back and make permanent repairs to rotted wood hull and delaminated FRP as identified. - 46CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2018
Resolution: Operator made repairs IAW repair proposal to satisfaction of attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 2 July 2018 Resolved
Vessel shall be inspected for compliance with the standards required. Grind back and make permanent repairs to rotted plywood deck starboard side forward compartment. - 46CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2018
Resolved 12 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2018 Resolved
Vessels shall be marked as required by parts 67 and 69 of this chapter. Place name of vessel and homeport on stern of vessel (4" in height) - 46CFR185.30-1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2018
Resolved 12 July 2018
Resolution: Operator applied name and hailing port to stern of vessel.
Communications › Alarms/Indicators › High Water Alarm
Issued 3 May 2018 Resolved
Vessel is equipped with three high level float switches; all switches failed to to activate audible and visual indicators at the operating station. Prove proper operation of bilge high level alarms.
Action required: 10 - Deficiency Rectified
Due 3 May 2018
Resolved 3 May 2018
Resolution: Upon further inspection, vessel was equipped with a switch to deactivate high level alarms at the operating station. Operator removed switch from service. Verified proper operation. Corrected on the spot.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 January 2017 Resolved
Provide copy of company drug testing policy. 46 CFR 16.401
Due 2 March 2017
Resolved 1 March 2017
Resolution: Verified company drug testing policy.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 January 2017 Resolved
Provide copies of employees signed drug testing policy. 46 CFR 16.401
Due 2 March 2017
Resolved 1 March 2017
Resolution: Verified enployees have signed policy.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 January 2017 Resolved
Provide proof of supervisor and employee EAP training. 46 CFR 16.401
Due 2 March 2017
Resolved 1 March 2017
Resolution: Verified proof of EAP training.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 January 2017 Resolved
Provide copy of contract with consortium. 46 CFR 16
Due 2 March 2017
Resolved 1 March 2017
Resolution: Verified contract with consortium.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 January 2017 Resolved
Replace one unserviceable adult lifejacket. 46 CFR 180.71
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Operator purchased new type I adult lifejacket. Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 23 January 2017 Resolved
Replace worn retroreflective material on one adult lifejacket. 46 CFR 180.71
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Operator purchased new lifejacket. Corrected on the spot.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 January 2017 Resolved
Provide onboard one portable flashlight. 46 CFR 183.430
Due 2 March 2017
Resolved 1 March 2017
Resolution: Operator provided portable light.
Engineering › Bilge Water Management System › Interface Detector
Issued 24 February 2012 Resolved
Provide visual and audible alarm for bilge high level IAW 46CFR182.530.
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 28 March 2012
Resolution: Evidence provided.
Engineering › Bilge Water Management System › Interface Detector
Issued 24 February 2012 Resolved
Provide visual and audible alarm for bilge high level IAW 46CFR182.530
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 28 March 2012
Construction/Loadline › Hull › Hull Plating
Issued 8 November 2010 Resolved
Provide to this office, a proposal for repair of the through hull fitting located in the center hold. Repairs shall not take place until proposal is approved by CG. A CG Marine inspector will witness repairs once completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2010
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 February 2010 Resolved
Physically separate child’s jackets from Adult jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2010
Resolution: Lifejackets separated
Lifesaving › Lifebuoys › Serviceable
Issued 11 February 2010 Resolved
Replace deteriorated life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2010
Resolution: Life ring replaced
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 February 2010 Resolved
Obtain alcohol and drug test kits.
Due 18 February 2010
Resolved 18 February 2010
Resolution: Pictures fwd to Sec. St. Petersburg via email.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 February 2010 Resolved
Replace (02) portable fire extinguishers that require servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2010
Resolution: Replaced (02) fire extinguishers
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 11 February 2010 Resolved
Update charts with most recent notice to mariners or within three years old.
Due 18 February 2010
Resolved 17 February 2010
Resolution: Charts replaced with current and updated charts
Operations/Management › Drills/Instruction › Fire
Issued 11 February 2010 Resolved
Show proficiency in Drills.
Due 18 February 2010
Resolved 17 February 2010
Resolution: Conducted satisfactory drills in presence of inspector.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 February 2010 Resolved
Show proficiency in drills.
Due 18 February 2010
Resolved 17 February 2010
Resolution: Conducted satisfactory drills in presence of inspector.
Engineering › Bilge Water Management System › Pump
Issued 17 July 2008 Resolved
DEMONSTRATE INSTALLATION AND OPERATION OF INDIVIDUAL BILGE PUMPS AND RELATED ELECTRICAL INSTALLATION FOLLOWING PLAN APPROVAL.
Due 26 May 2009
Resolved 20 January 2009
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 February 2007 Resolved
Vessel to display EAP Policy, Statement and hotline number.
Due 5 March 2007
Resolved 27 February 2007
Resolution: Vessel provided copy of EAP Placard via fax.
Lifesaving › Hand Flares › Expired
Issued 26 February 2007 Resolved
Replace 3 expired flares with 3 unexpired ones.
Due 5 March 2007
Resolved 27 February 2007
Resolution: Vessel rep faxed copy of flares purchase receipt.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 February 2007 Resolved
Mark ring lifebuoy with vessel name
Due 5 March 2007
Resolved 16 May 2007
Resolution: Lifering was marked.
Engineering › Gasoline Engine (propulsion) › Hose, Cooling System (4 cycle)
Issued 26 February 2007 Resolved
Replace flexible fuel line from engine to fuel filter w/ USCG approved type
Due 5 March 2007
Resolved 16 May 2007
Resolution: Fuel hose was replaced w/ USCG type hose.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 February 2007 Resolved
Replace wing nuts on batteries with lock washers
Due 5 March 2007
Resolved 16 May 2007
Resolution: Lock washers were installed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 February 2007 Resolved
Label fuel shut off IWO fuel tank box
Due 5 March 2007
Resolved 16 May 2007
Resolution: Shut off vlv was labeled.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 February 2007 Resolved
Replace or renew vessel anchor light with serviceable one
Due 5 March 2007
Resolved 16 May 2007
Resolution: Anchor light was replaced.
Lifesaving › Buoyant Apparatus › Approval
Issued 6 March 2006 Resolved
Provide one 24 inch ring life buoy IAW 46CFR180.30-5. They had a 20 inch ring onboard.
Condition: Placed in Improper Service
Due 14 March 2006
Resolved 6 March 2006
Resolution: POC faxed a receipt of a ring life buoy purchase and followed up with an e-mail. Cleared deficiency
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 March 2005 Resolved
Update all nautical publications IAW 46CFR184.420. (ie: charts, coast pilot, lightlist, notices to mariners, tide and current tables)
Condition: Improper/Lack of Maintenance
Due 14 March 2005
Resolved 9 March 2005
Lifesaving › Hand Flares › Approval
Issued 7 March 2005 Resolved
Prior to the carriage of passengers, provide 03 red handheld day/night flares. Three flares had expired.
Condition: Improper/Lack of Maintenance
Due 7 March 2005
Resolved 9 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 11 March 2004 Resolved
PROVIDE 1 B-II TYPE MARINE FIRE EXTINGUISHER PRIOR TO CARRIAGE OF PASSENGERS.
Due 18 March 2004
Resolved 12 March 2004
Resolution: FAX DOCUMENTATION.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 March 2004 Resolved
POST LIFEJACKET DONNING PROCEDURES.
Due 18 March 2004
Resolved 12 March 2004
Resolution: FAX DOCUMENTATION.
Documentation › Certificates/Documents
Issued 11 March 2004 Resolved
PROVIDE CURRENT DOCUMENTATION CERTIFICATE.
Due 18 March 2004
Resolved 11 March 2004
Resolution: WITNESSED.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 21 March 2003 Resolved
PROVIDE ONE USCG MARINE TYPE B-II FIRE EXTINGUISHER PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Number
Condition: Improper Installation
Due 1 April 2003
Resolved 14 April 2003
Communications › Radio Communications
Issued 21 March 2003 Resolved
PROVIDE FCC RADIOTELEPHONE SAFETY CERTIFICATE. LEGACY COMPONENT DESC: FCC
Condition: Unknown
Due 21 April 2003
Resolved 14 April 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 March 2003 Resolved
REPLACE RETOFLECTIVE MATERIAL ON LIFEJACKETS AS NEEDED. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 1 April 2003
Resolved 14 April 2003
Engineering › Bilge Water Management System
Issued 21 March 2003 Resolved
CONDUCT TEST OF BILGE MANIFOLD SYSTEM. LEGACY COMPONENT DESC: Manifold
Due 21 April 2003
Resolved 14 April 2003
Personnel › Training
Issued 5 March 2002 Resolved
Obtain current Red Cross/First aid cards for 50% of the crew. LEGACY COMPONENT DESC: First Aid/CPR
Due 5 April 2002
Resolved 1 April 2002
Lifesaving › Lifebuoys
Issued 5 March 2002 Resolved
Replace grab line on ring buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 5 April 2002
Resolved 1 April 2002
Electrical › Electrical Distribution System (service)
Issued 5 March 2002 Resolved
Remove dead end wiring in electrical distribution panel. LEGACY COMPONENT DESC: Wiring
Due 5 April 2002
Resolved 1 April 2002
Operations/Management › Drug and Alcohol Testing
Issued 5 March 2002 Resolved
Provide evidence of a current annual drug and alchol program. LEGACY COMPONENT DESC: Proof of Enrollment
Due 5 March 2002
Resolved 1 April 2002
Personnel › Training
Issued 5 March 2002 Resolved
Provide a current training log book. LEGACY COMPONENT DESC: Personal Survival Techniques
Due 5 March 2002
Resolved 1 April 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 March 2002 Resolved
Rejected 44 PFD's passenger count is reduced to 24 plus 2 crew for a total of 26 persons. LEGACY COMPONENT DESC: Condition
Due 5 April 2002
Resolved 1 April 2002
Lifesaving › Hand Flares
Issued 5 March 2002 Resolved
Provide 3 red hand flares and 3 orange day smoke flares, prior to carring passengers.. LEGACY COMPONENT DESC: EXPIRED
Due 5 March 2002
Resolved 5 March 2002
Lifesaving
Issued 5 February 2001 Resolved
RENEW O3 ORANGE RED HAND HELD FLARES.
Condition: Unknown
Due 5 February 2001
Resolved 5 February 2001
Documentation
Issued 5 February 2001 Resolved
OBTAIN FCC RADIOTELEHONE SAFETY CERTIFICATE OR PROVIDE DOCUMENTATION VESSELOPERATES LESS THAN 1,OOO FEET FROM SHORE.
Condition: Unknown
Due 5 February 2001
Resolved 5 February 2001
Fire Fighting
Issued 31 January 2000 Resolved
PRIOR TO CARRIAGE OF PASSENGERS SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Lifesaving
Issued 31 January 2000 Resolved
SCHEDULE UNDERWAY MAN OVERBOARD AND FIRE DRILL WITH USCG OVERSIGHT.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Navigation
Issued 31 January 2000 Resolved
PRIOR TO GETTING UNDERWAY REPAIR PORT RUNNING LIGHT.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Lifesaving
Issued 31 January 2000 Resolved
PASSENGER CAPACITY REDUCED TO 22 ADULTS PENDING REPLACEMENT OF 10 ADULT- SIZE PFD'S.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Unknown
Issued 10 February 1999 Resolved
IMPLEMENT EMPLOYEE ASSISTANCE PROGRAM W/HELP PHONE NUMBER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1999
Resolved 11 March 1999
Navigation
Issued 10 February 1999 Resolved
REPAIR STARBOARD NAV. LIGHT AND STERN LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1999
Resolved 12 February 1999
Unknown
Issued 10 February 1999 Resolved
PROVIDE PROCEDURES FOR PRE-EMPLOYMENT TESTING AND SERIOUS MARINE INCIDENT TESTING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1999
Resolved 11 March 1999
Unknown
Issued 10 February 1999 Resolved
PROVIDE LAB AND COLLECTION SITE CERTIFICATIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1999
Resolved 11 March 1999
Documentation
Issued 13 February 1997 Resolved
PROVIDE PROOF OF ENROLLMENT IN RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 20 February 1997
Resolved 20 February 1997
Lifesaving
Issued 13 February 1997 Resolved
PROVIDE ONE RING LIFE BUOY AND INSTALL REFLECTIVE TAPE ON QUADRANTS.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Lifesaving
Issued 13 February 1997 Resolved
PROVIDE 5 ADULT AND 4 CHILD-SIZE LIFE PRESERVERS AND STENCIL VESSEL NAME ONEACH.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Fire Fighting
Issued 18 January 1995 Resolved
Mount 1 B-II fire extinguisher.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Fire Fighting
Issued 18 January 1995 Resolved
Provide 1 additional B-I fire extinguisher permanently mounted at helm.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Lifesaving
Issued 3 February 1994 Resolved
Renew expired flares.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Navigation
Issued 3 February 1994 Resolved
Replace socket for starboard running light.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Documentation
Issued 3 February 1994 Resolved
Renew FCC certificate. Limited to not more than 1000 feet from shore untilcomplete.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Fire Fighting
Issued 4 March 1991 Resolved
SERVICE BOTH DRY CHEMICAL FIRE EXTINGUISHERS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Lifesaving
Issued 4 March 1991 Resolved
PROVIDE 3 RED AND 6 ORANGE HAND HELD FLARES.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Accommodation/Occupational Safety
Issued 21 August 1990 Resolved
REPLACE 4 FWD HAND RAILS ON BOW AND 3 COURSES.
Condition: Unknown
Due 21 August 1990
Resolved 21 August 1990
Fire Fighting
Issued 7 March 1990 Resolved
PROVIDE 2 MARINE BRACKETS FOR FIRE EXTINGUISHERS BY 07MAY90.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Documentation
Issued 7 March 1990 Resolved
POST THE STABILITY LETTER UPON RECEIPT.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Lifesaving
Issued 7 March 1990 Resolved
RENEW 2 RED FLARES BY 30APR90.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Documentation
Issued 23 August 1989 Resolved
DRYDOCK DUE 23FEB91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Documentation
Issued 5 April 1988 Resolved
PROVIDE A VALID FCC RADIO STATION LICENSE AND RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 5 April 1988
Resolved 5 April 1988
Navigation
Issued 5 April 1988 Resolved
INSTALL A STERN LIGHT W/135 DEGREE AREA OF VISIBILITY AND 2 MILE INTENSITY AND INSTALL ANCHOR LIGHT ON SEPARATE CIRCUIT PRIOR TO OPERATING AT NIGHT BUT NO LATER THAN 05MAY88.
Condition: Unknown
Due 5 April 1988
Resolved 5 April 1988
Lifesaving
Issued 5 April 1988 Resolved
STENCIL VESSEL'S NAME AND INSTALL 60' LINE TO THE NEW RING BOUY.
Condition: Unknown
Due 5 April 1988
Resolved 5 April 1988
Lifesaving
Issued 5 April 1988 Resolved
PROVIDE ONE WATERLIGHT ATTAINED UNDER 46CFR 161.010 PRIOR TO OPERATING AT NIGHT.
Condition: Unknown
Due 5 April 1988
Resolved 5 April 1988

Casualty record · 1

8 November 2010Routine · role: Involved in a Marine Casualty · activity 3887397
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.