GLACIER QUEEN II

GLACIER QUEEN II is a 1978 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1985, most recently in August 2022, along with 78 deficiencies.

Records from 1985 to 2022. Most recent: inspection, 26 August 2022.

Built
1978
Last inspected
26 August 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCQ8984
Flag
UNITED STATES
366745140 (licence lapsed)
Maury page id
psix-49591

Inspections, by type

…with no type recorded5
Years with a record 25 calendar years (1985–2022)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCQ8984MMSI 366745140 · expired · compulsorily equipped · granted 2 March 2005, cancelled 27 June 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 64

26 August 2022 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7544104
23 April 2008 MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3191612
11 April 2008 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3182224
12 October 2007 Internal Structural Exam · Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3089934
7 May 2007 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2924518
30 March 2007 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2900344
11 July 2006 In-Service Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2716421
7 April 2006 Deficiency Check · MARPOL Annex V Examination · Annual Inspection · Administrative Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2622569
7 April 2006 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2646831
12 January 2006 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2565753
5 January 2006 Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2561525
15 August 2005 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2463962
11 August 2005 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2463987
7 June 2005 Deficiency Check · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2385088
5 August 2004 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2156873
21 October 2003 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1934607
26 June 2003 Administrative Inspection · Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1828550
16 May 2002 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1696226
24 October 2001 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1384915
6 September 2001 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1072937
6 September 2001 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1073495
26 July 2001 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1376732
31 May 2000 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1423390
30 September 1999 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1041008
6 September 1999 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1423259
30 June 1999 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1086265
14 June 1999 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1386526
27 June 1998 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1130225
8 April 1998 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1122764
12 June 1997 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1110568
28 April 1997 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1100282
15 April 1997 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1096280
2 July 1996 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1086895
22 May 1996 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1084576
21 May 1996 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1084572
8 April 1996 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1083492
29 March 1996 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1081145
6 February 1996 Plan Review "T" Boat
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 884969
14 June 1995 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1191934
16 May 1995 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1234223
26 April 1995 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1205714
3 May 1994 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 858929
13 April 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1447340
5 October 1993 Drydock Extension
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 847160
3 May 1993 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1142363
19 April 1993 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 835412
6 May 1992 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1268290
9 April 1992 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1267082
17 December 1991 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1267953
15 May 1991 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1237318
18 May 1990 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1212874
9 April 1990 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 912345
13 September 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1033864
13 September 1989 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1033865
16 August 1989 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1194810
2 May 1989 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1036399
2 May 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1039027
28 March 1988 Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1341141
1 June 1987 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1334820
20 May 1987 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1333819
29 April 1987 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1320139
6 May 1986 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1294707
13 September 1985 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1298707
2 May 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1288829

Deficiency record · 78

Electrical › Electrical Distribution System (service) › Conductor
Issued 23 April 2008 Resolved
Provide non-conductive mat at starboard breaker panel in generator room
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 15 May 2008
Engineering › Bilge Water Management System › Piping
Issued 23 April 2008 Resolved
Provide wire reinforced hose for engineroom bilge pump. (Rule pump)
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 15 May 2008
Engineering › Fuel Oil Service System › Piping
Issued 23 April 2008 Resolved
Provide solid bottom plugs at all fuel filters.
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 15 May 2008
Fire Fighting › Fire Hoses › Material
Issued 23 April 2008 Resolved
Prove new fire hose meets UL 19 standard
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 15 May 2008
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 23 April 2008 Resolved
Remove door tie back to forward engine room door.
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 23 April 2008
Resolution: The bungee cord was removed prior to the completion of the inspection.
Construction/Loadline › Hull › Hull Plating
Issued 12 October 2007 Resolved
Grind flaking aluminum on starboard side exhaust to good metal & submit repair plan to Sector Anchorage
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 November 2007
Resolved 6 March 2008
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 26 April 2007 Resolved
Repair starboard engine shaft stuffing box due to excess leakage
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 26 April 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 23 April 2007 Resolved
Provide means to shut-down generator room natural ventilation.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Fire Fighting › Ventilation Systems › Operating Controls
Issued 23 April 2007 Resolved
Label Ventilation shut-down for eng room on distribution panel.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 26 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 July 2006 Resolved
Properly wire under cabinet receptacles in galley. Tag out until complete.
Condition: Improper Installation
Due 18 July 2006
Resolved 19 July 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 July 2006 Resolved
Install covers to all receptacles aboard vessel where missing.
Due 18 July 2006
Resolved 19 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 July 2006 Resolved
Remove power strip IVO PA system.
Condition: Improper Installation
Due 11 July 2006
Resolved 11 July 2006
Resolution: Removed fm vessel prior to my departure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 July 2006 Resolved
Remove unapproved extension chords from vessel.
Condition: Improper Installation
Due 11 July 2006
Resolved 11 July 2006
Resolution: Removed from vessel prior to my departure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 July 2006 Resolved
Remove or properly terminate airphone system deadended wires in baggage/tool space.
Due 18 July 2006
Resolved 19 July 2006
Construction/Loadline › Hull › Bottom Plating
Issued 11 July 2006 Resolved
Remove concrete patch forward of port engine at next hull exam.
Due 21 October 2007
Resolved 12 October 2007
Engineering › Bilge Water Management System › Valve
Issued 11 July 2006 Resolved
Install positive stop action valve at sideshell for submersible bilge pump in engine room.
Due 18 July 2006
Resolved 19 July 2006
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 April 2006 Resolved
Mark generator space emergency escape hatches (undersides) with "EMERGENCY ESCAPE, KEEP CLEAR".
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 19 April 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 April 2006 Resolved
Hydro-test portable B-II fire extinguisher located in main-level passenger accomodations space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 19 April 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 7 April 2006 Resolved
Recharge B-I dry-chemical fire extinguisher located in tool room. (Pressure guage needle in "recharge" position. This is a non-required supplemental extinguisher. Advised Captain that it is advantageous to have additional extinguishers; however they must be properly serviced and operational).
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 19 April 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 7 April 2006 Resolved
Recharge B-I halon fire extinguisher located in generator space. (Pressure guage needle in "recharge" position. This is a non-required supplemental extinguisher. Advised Captain that it is advantageous to have additional extinguishers; however they must be properly serviced and operational).
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 19 April 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 April 2006 Resolved
Recharge engine room B-II CO2 portable fire extinguisher. (This extinguisher discharged during actual onboard fire response while conducting underway drills).
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 19 April 2006
Operations/Management › Drills/Instruction › Fire
Issued 7 April 2006 Resolved
Conduct fire drill in presence of USCG Marine Inspector, to include operational test of fire pump. (Original inspection fire drill disrupted by actual fire in electric motor that powers fire pump).
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 19 April 2006
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 7 April 2006 Resolved
Secure painter to STBD-AFT IBA (unit must be rotated in stow-cradle to allow for this).
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 19 April 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 April 2006 Resolved
Mark top-side lifejacket stowage lockers with type and number of contents.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 19 April 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 April 2006 Resolved
Make operable, visual indicators (lamps) for bilge high-level alarms.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 19 April 2006
Construction/Loadline › Structures › End Bulkhead
Issued 7 April 2006 Resolved
Cover exposed opening from removed vent fan (located immediately above hose station #3 on aft weatherdeck bulkhead).
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 19 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2006 Resolved
Secure loose wires on bottom-side of two switchboards (STBD-FWD), and on battery (STBD-AFT); located in generator space.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 19 April 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 June 2005 Resolved
Replace non metallic piping in raw water system with materials that meet SAE J 1492.
Due 7 July 2005
Resolved 11 August 2005
Communications › Radio Communications › EPIRB
Issued 4 August 2004 Resolved
Replace hydrostatic release for EPIRB. Vessel is limited to three miles until this deficiency is resolved.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: A new hydrostatic release for the Epirb was installed. Vessel Captain claims that the hydrostatic release was replaced by 30 August 04.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2004 Resolved
Remove extentin cords from space forward fo engine room.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: The estension cords were removed.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 4 August 2004 Resolved
Remove bed from space forward of engine room.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: The mattress is no longer in the space.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 August 2004 Resolved
Repair/Replace broken deck light globe starboard amidships 2nd deck.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: A new globe was installed.
Fire Fighting › Fire Main › Pressure
Issued 4 August 2004 Resolved
Install gauge for firemain/pump.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: A gauge at the firepump was installed.
Engineering › Compressed Air System (start air) › Valve
Issued 4 August 2004 Resolved
Replace lift ring on pressure relief valve, on bottom compressor.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: A lifting ring was installed on the valve.
Electrical › Electrical Distribution System (service) › Conductor
Issued 4 August 2004 Resolved
Repair wiring on portable bile pump.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: The wiring on the bilge pump was repaired.
Stability › Unintentional Flooding › General
Issued 4 August 2004 Resolved
Replace handle on bilge system.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: A handle was installed on the valve.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 August 2004 Resolved
Install lagging on exhaust manifold on center engine.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: Insulation was installed on the exhaust manifold.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 August 2004 Resolved
Provide the following (current) navigation publications. U.S. Coast Pilot, Coast Guard light list, Tide Table/current tables.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: The appropriate parts of the navigation publications were printed off the internet and put in a notebook on the bridge.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 4 August 2004 Resolved
[name withheld] Room emergency exit located port side aft.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: The emergency exit was marked.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 4 August 2004 Resolved
Make air recievers open for inspection.
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 28 April 2005
Resolution: The air recievers were opened and inspected.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 4 August 2004 Resolved
Instal locking device and replace missing handle on sewage overboard.
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 7 June 2005
Resolution: a locking device was placed on the sewage overboard valve.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2004 Resolved
Repair/replace/remove household grade wiring in generator space.
Due 4 September 2004
Resolved 7 June 2005
Resolution: The household wiring was removed from the space.
Documentation › Markings/Placards
Issued 26 June 2003 Resolved
REMOVE OLD COI DECALS FROM UPPER DECK AFT DOOR & PORT MAIN DECK WINDOW LEGACY COMPONENT DESC: Inspection Decal
Due 26 July 2003
Resolved 15 July 2003
Resolution: Administratively cleared per master fax
Operations/Management › Drills/Instruction
Issued 26 June 2003 Resolved
RELOCATE OR INSTALL NEW LIFESLING HOOKS TO P/S MAIN DECK DOORS LEGACY COMPONENT DESC: Man Overboard Recovery
Due 26 July 2003
Resolved 15 July 2003
Resolution: Administratively cleared per master fax
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 June 2003 Resolved
REPLACE S/C MDE STOP SOLENOIDS TO OPERATE FROM PILOTHOUSE LEGACY COMPONENT DESC: Remote Stopping Device
Due 26 July 2003
Resolved 15 July 2003
Resolution: Administratively cleared per master fax
Engineering › Freshwater Generation System
Issued 26 June 2003 Resolved
REPAIR/REPLACE POTABLE WATER PRESSURE TANK (LEAKS AT OUTLET PIPE) LEGACY COMPONENT DESC: Piping
Due 26 July 2003
Resolved 15 July 2003
Resolution: Administratively cleared per master fax
Operations/Management › Lifesaving
Issued 26 June 2003 Resolved
POST LIFEJACKET DONNING INSTRUCTIONS LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Due 26 July 2003
Resolved 15 July 2003
Resolution: Administratively cleared per master fax
Fire Fighting › Fire Main
Issued 26 June 2003 Resolved
REPLACE FIREMAIN PRESSURE GAUGE LEGACY COMPONENT DESC: Pressure
Due 26 July 2003
Resolved 15 July 2003
Resolution: Administratively cleared per master fax
Electrical › Electrical Distribution System (service)
Issued 26 June 2003 Resolved
INSTALL BLANKS IN STBD DISTRIBUTION PANEL LEGACY COMPONENT DESC: Circuit Breaker
Due 26 July 2003
Resolved 15 July 2003
Resolution: Administratively cleared per master fax
Accommodation/Occupational Safety › Washroom/Toilet
Issued 26 June 2003 Resolved
REPAIR WATER LEAKS (AT LEAST 2) ON PORT LOWER HEAD FLUSH WATER SUPPLY LINES. LEGACY COMPONENT DESC: Toilet
Due 26 July 2003
Resolved 15 July 2003
Resolution: Administratively cleared per master fax
Construction/Loadline
Issued 26 July 2001 Resolved
MARK ALL DOORS AND HATCHES WITH OPEN/CLOSE DIRECTION
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Construction/Loadline
Issued 26 July 2001 Resolved
MARK WTD "KEEP CLOSED UNDERWAY"
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Accommodation/Occupational Safety
Issued 26 July 2001 Resolved
REPAIR WATER HEATER PIPING LEAK
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Fire Fighting
Issued 26 July 2001 Resolved
REPLACE MISSING CO2 ALARM SIGN ON PORT SIDE ENGINROOM
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Documentation
Issued 26 July 2001 Resolved
LOCATE AND POST PAGE 2 OF STABILTY LETTER
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Documentation
Issued 26 July 2001 Resolved
LOCATE AND POST ORIGINAL COI
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Construction/Loadline
Issued 26 July 2001 Resolved
REPLACE MISSING DECK COVER PLATE ENGINEROOM CENTERLINE
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Navigation
Issued 26 July 2001 Resolved
POST EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 26 July 2001
Resolved 26 July 2001
Construction/Loadline
Issued 6 September 1999 Resolved
Vee and weld starboard exhaust at aft bulkhead (stern) on the interior.
Condition: Unknown
Due 6 September 1999
Resolved 6 September 1999
Construction/Loadline
Issued 6 September 1999 Resolved
Repair or renew forepeak hatch cover.
Condition: Unknown
Due 6 September 1999
Resolved 6 September 1999
Engineering
Issued 28 April 1997 Resolved
REPLACE AIR SAFETY VALVES ON UPPER PRESSURE VESSELS LOCATED PORT AND STBD AFT ENGINEROOM.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Electrical
Issued 28 April 1997 Resolved
PROVIDE ELECTRICAL SHOCKPROOF MATTING AT ELECTRICAL PANEL LOCATED AT BOTTOMOF GENERATOR ROOM LADDER.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Lifesaving
Issued 8 April 1996 Resolved
CONDUCT SATISFACTORY FIRE, ABANDON SHIP AND MAN OVERBOARD DRILLS IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Lifesaving
Issued 8 April 1996 Resolved
INSTALL RETRO REFLECTIVE TAPE ON RING BUOY MOUNTED ON STERN OF VESSEL.
Condition: Unknown
Due 8 April 1996
Resolved 16 April 1996
Engineering
Issued 8 April 1996 Resolved
REPLACE PORT PROPELLER DUE TO PITTING CAUSED BY ELECTROLYSIS.
Condition: Unknown
Due 8 April 1996
Resolved 16 April 1996
Lifesaving
Issued 8 April 1996 Resolved
REPLACE THREE CHILD'S PFDS REJECTED BY INSPECTOR DUE TO EXCESSIVE WEAR.
Condition: Unknown
Due 8 April 1996
Resolved 16 April 1996
Lifesaving
Issued 26 April 1995 Resolved
CONDUCT MANOVERBOARD, ABANDON SHIP AND FIRE DRILL.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Engineering
Issued 26 April 1995 Resolved
PROVE PROPER OPERATION OF NUMBER TWO S/S GEN OVERSPEED SHUTDOWN.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Engineering
Issued 3 May 1994 Resolved
REPLACE ALL PETCOCK ON FUEL FILTERS WITH PROPER VALVES OR PLUGS.
Condition: Unknown
Due 31 May 1994
Resolved 3 June 1994
Engineering
Issued 3 May 1994 Resolved
REPAIR AND PROVE PROPER OPERATION OF OIL PRESSURE ALARM AND SHUTDOWN FOR NO. 2 S/S GEN.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Lifesaving
Issued 3 May 1994 Resolved
CONDUCT THE FOLLOWING DRILLS IN THE PRESENCE OF A MARINE INSPECTOR FIRE, ABANDON SHIP AND MAN OVERBOARD.
Condition: Unknown
Due 31 May 1994
Resolved 3 June 1994
Engineering
Issued 3 May 1994 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIPS ON BOTH S/S GENERATORS BY THE USEOF HAND TACH OR OTHER MEANS TO VERIFY ENGINE RPM'S.
Condition: Unknown
Due 31 May 1994
Resolved 3 June 1994
Electrical
Issued 3 May 1994 Resolved
INSTALL BLANK PLAT FOR MISSING BREAKER IN 12 VOLT PANEL LOCATED IN THE WHEEL HOUSE.
Condition: Unknown
Due 31 May 1994
Resolved 3 June 1994
Construction/Loadline
Issued 1 June 1987 Resolved
MAKE PERMANENT REPAIRS BY INSERT IN WAY OF THE BOTTOM PLATING WHERE TEMP WELD REPAIRS HAVE BEEN MADE AT THE FWD. END OF THE PORT M.E. BED FRAME WHERE IT IS ATTACHED TO THE BOTTOM PLATING. REPAIRS ARE TO BE MADE TO THE SATISFACTION OF THE COGNIZANT O.C.M.I.
Condition: Unknown
Due 1 June 1987
Resolved 1 June 1987
Fire Fighting
Issued 29 April 1987 Resolved
REPLACE FLEXIBLE RADIATOR TYPE HOSES ON FIRE PUMP DISCHARGE LINE IN WAY OF PORT MAIN ENGINE. HOSES TO BE REPLACED WITH HARD PIPING OR EQUIVALENT
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Electrical
Issued 29 April 1987 Resolved
DEMONSTRATE OPERATION OF LOW LUBE OIL SHUT DOWN ON THE STARBOARD GENERATOR SET.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Engineering
Issued 29 April 1987 Resolved
REPLACE ALL RELIEF VALVES ON THE MAIN ENGINE STARTING AIR RECEIVERS AND DEMONSTRATE OPERATION TO THE ATTENDING CG MARINE INSPECTOR. ALSO, REPLACE ALL PRESSURE GAUGES ON AIR RECEIVERS WITH GAUGES THAT EXCEED THE MAWP OF THE AIR RECEIVER.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE 1 ADDITIONAL RING BOUY WITH 60 FEET OF LINE AND AN OPERATIONAL WATER LIGHT.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.