Records from 2013 to 2026. Most recent: inspection, 24 April 2026.
Inspection history · 21
24 April 2026
Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8355516
17 March 2026
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8327348
31 March 2025
COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8102862
25 October 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8024864
19 March 2024
Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7882084
3 April 2023
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7660638
17 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7479837
27 April 2022
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7439561
24 May 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7205939
9 July 2020
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7002031
26 June 2020
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6987760
16 June 2020
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6980395
2 April 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6937494
13 March 2020
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6928175
4 June 2019
Deficiency Check · Annual Inspection · DAPI Audit · Damage Survey · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6710167
28 March 2018
Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6311027
14 March 2018
COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6311009
15 March 2017
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6108393
1 March 2017
Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6096625
19 February 2016
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5818285
22 January 2016
Plan Review "T" Boat · Annual Inspection · Simplified Stability Test
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5837760
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021
Resolved
Ring buoy stencil marking has faded. Re-mark life ring buoy as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner re stenciled vessels name onto the life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 May 2021
Resolved
Provide life jacket donning placards for both types of life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner removed type I life jackets that didnt match donning placard and replaced with ones that did.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2021
Resolved
Fire bucket stenciling has faded. Re-mark fire buckets as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner restenciled fire buckets.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 May 2021
Resolved
Provide first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner renewed vessel's first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021
Resolved
Ring buoy floating light battery has expired. Renew battery.
Action required: 10 - Deficiency Rectified
Due 24 May 2021
Resolved 24 May 2021
Resolution: New battery installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 May 2021
Resolved
Provide updated Nav Pubs. (Light list & Coast Pilot)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 7 June 2021
Resolution: Owner had onboard new and updated Navigation Publications.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 June 2020
Resolved
The vessel's bottom was damaged aft of the collision bulkhead. The vessel is taking on water. After taking the vessel out of the water and prior to making repairs, the damage must be witnessed by USCG marine inspectors in person at the vessel to discuss a repair plan. The plan must be approved by marine inspectors prior to repairs being started. The repairs, once finished, must also be verified by marine inspectors prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2020
Resolved 9 July 2020
Resolution: Repairs effected and witnessed by CG.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2020
Resolved
Provide evidence of satisfactory servicing of portable fire extinguishers by a qualified servicing organization/individual.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2020
Resolution: Servicing complete.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2020
Resolved
Arrange for inspection/servicing of the vessel's CO2 fixed firefighting system by a qualified servicing organization/individual. Provide at least 24 hours of notice to the CG when testing will occur at [phone withheld].
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2021
Resolution: Portable and fixed fire fighting serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 June 2020
Resolved
Re-install guards around engines to protect against rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2021
Resolution: Owner re installed machinery guards.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 June 2020
Resolved
Post new emergency broadcast placard to replace illegible one.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2021
Resolution: Owner posted a new emergency broadcast placard.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 16 June 2020
Resolved
Provide proof of EPIRB registration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
Resolution: Registration proof provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 June 2020
Resolved
Remove and properly terminate dead ended wiring for tuna bait pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
Resolution: Dead end wires removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 June 2020
Resolved
Repair/replace box on centerline pump in engine room. Ensure electrical components are not exposed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
Resolution: Electrical componenets covereed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 June 2019
Resolved
Vessel must provide a fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76, or provide a fixed-gas fire extinguishing system that is capable of automatic discharge upon heat detection. All plans for either system must be submitted to MSC for review and approval by 01APR20
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 24 May 2021
Resolution: New Fireboy automatically activating
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 June 2019
Resolved
Provide installed fire protection for the engine room
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2019
Resolution: Vessel has installed CO2 bottle back in the vessel
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 June 2019
Resolved
Vessel has installed temporary repair to the area around the port rudder and must provide a written repair plan for the hull damage around the port rudder for the next dry dock in March of 2020 to include inspection of the rudder wood box framing to the local OCMI for approval
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 13 March 2020
Resolution: Accepted previosuly-performed repair as permanent, subject to verification at future ISEs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2019
Resolved
Remove dead end wire in the engine room on the fwd bulkhead on the port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2019
Resolution: Vessel has removed dead end wires
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 June 2019
Resolved
Repair top aft passenger safety rail.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2019
Resolution: Vessel has repaired railing
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 4 June 2019
Resolved
Provide a current FCC Radiotelephony certificate
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2019
Resolution: Vessel has RCVD a new FCC Radiotelephony certificate
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2019
Resolved
Install valves on all electric Bilge pumps piping at
the hull during next dry docking
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 9 July 2020
Resolution: Skin valves installed.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 4 June 2019
Resolved
Conduct underway man over board, fire and abandon ship drills with the attending CG Inspector by 14 June 19
Action required: 705 - Other - as specified
Due 14 June 2019
Resolved 13 June 2019
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 March 2018
Resolved
Upper railing needs to be welded at all seams.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2018
Resolution: Upper railing secured and satisfactorily tested with load applied.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 March 2018
Resolved
Replace lens on mast light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 28 March 2018
Resolution: Forward masthead light replaced IAW COLREGS.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2018
Resolved
Dead end wires found in wheel house and engine room need to be removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 28 March 2018
Resolution: Wiring removed as requested.