Records from 1999 to 2020. Most recent: inspection, 27 April 2020.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
27 April 2020
Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6944736
18 November 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6857299
9 October 2018
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6557921
25 July 2018
Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 6493693
22 April 2018
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6396882
9 December 2017
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6321367
18 July 2017
Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 6221925
20 April 2016
Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5858194
19 January 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5806932
8 October 2014
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5001157
12 May 2014
Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4852961
8 June 2012
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4335549
17 May 2012
Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4313921
11 May 2012
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4311192
30 July 2009
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3550594
7 August 2006
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2738455
14 September 2005
Deficiency Check · Hull Examination · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2488078
11 March 2005
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2307917
2 December 2004
Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2251765
10 November 2004
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2237984
13 November 2003
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1948182
24 July 2003
Administrative Inspection · MARPOL Annex V Examination · Periodic Inspection · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1854959
19 September 2002
Examination of Repairs · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1676818
15 August 2002
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1660325
9 August 2001
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1068975
2 August 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 773170
2 July 2001
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1376653
2 July 2001
MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1415654
14 August 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1469317
20 July 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1102583
28 June 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1090387
14 June 1999
Initial Certification · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375817
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 November 2019
Resolved
FCC safety certificate must be onboard and valid. Current FCC Safety Certificate expires on 1SEPT2019. Provide proof of valid FCC certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 November 2019
Resolved
Crew training for emergency situation must be conduct quarterly and logged. Provide proof of crew training conducted
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 November 2019
Resolved
Provide proof of chemical testing program for crew member.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2019
Resolved
Provide proof of annual services conducted on (03) portable CO2 fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 November 2019
Resolved
Provide up-to-date coastal pilot, light list, tide table and local notice to mariners.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 November 2019
Resolved
Replace all identified expired first aid contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 November 2019
Resolved
Repair damaged FRP in a way of port and STBD engine room ventilation screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 October 2018
Resolved
Portable CO2 must be serviced annually. Onboard portable CO2 have expired service tags.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2018
Resolved 10 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 October 2018
Resolved
Adult type I life jackets must be serviceable conditions. Found torn/damage(06) adult life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2018
Resolved 10 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 October 2018
Resolved
Vessel must have operational navigation lights. Found inoperable stern light.
Action required: 60 - Rectify deficiencies prior to movement
Due 24 October 2018
Resolved 10 October 2018
Documentation › Logs/Records › Logbook (official)
Issued 1 February 2016
Resolved
Crew training shall be logged as required by 46 CFR 185.420. Missing training log on board. Provide documentation on completed quarterly crew training to attending MI for review.
Due 13 February 2016
Resolved 2 February 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 February 2016
Resolved
Vessel must have operating navigation light as required by Inter'l inland Navigation Rules. Vessel's stern light was inoperable. Show proper stern light operation to attending MI.
Due 12 February 2016
Resolved 2 February 2016
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 1 February 2016
Resolved
Vessel must have onboard adequate and up- to-date chart and pubs as required by 46 CFR 184.420. Missing Nav rules, Local Notice to Mariners, Light list, Coast Pilot & Tide tables. Provide up-to-date pubs on board.
Due 12 February 2016
Resolved 2 February 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 February 2016
Resolved
All portable fire extinguisher must be serviced annually as required by 46 CFR 176.810. Service tags on CO2 shows last service Sept 2014. Provide proof of service performed on all portable CO2.
Due 12 February 2016
Resolved 2 February 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 February 2016
Resolved
Qualified person must test and service the system annually as required by 46 CFR 176.810. Last record service performed on FGFE was Sep 2014. Provide proof of completed service on FGFE.
Due 12 February 2016
Resolved 2 February 2016
Engineering › Fuel Oil Service System › Hose
Issued 1 February 2016
Resolved
Flexible hose designed for use with hose clamps may be installed with two hose clamps as required by 46 CFR 182.720. Missing hose clamps on port fuel tank supply hose. Install missing hose clamps.
Due 12 February 2016
Resolved 2 February 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 February 2016
Resolved
Vessel at least 26 feet must have visual and audible bilge high level alarm at the operating station as required by 46 CFR 182.530. Inoperable bilge high level alarm for mid void. Show proper operation on bilge high level alarm.
Due 12 February 2016
Resolved 2 February 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 1 February 2016
Resolved
Vessel must meet the requirements for VHF-DSC as required by CG-CVC policy Letter 15-06, dated 15DEC2015. Provide a receipt for the VHF-DSC purchased or evidence of a scheduled radio installation.
Due 30 March 2016
Resolved 31 March 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 October 2014
Resolved
No FCC Safety Radio Certificate on board. Provide proof of valid FCC Safety Certificate to MI. 46CFR184.502
Due 15 October 2014
Resolved 9 October 2014
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 October 2014
Resolved
Insufficient hose clamp on flexible hose for salt water cooling system. Install two hose clamps at both end of the hose. 46CFR182.720 (e)(v)(B)
Due 15 October 2014
Resolved 9 October 2014
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 9 June 2014
Resolved
Exhaust blower switches must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. And all other requirements of 46CFR182.460.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2014
Communications › Alarms/Indicators › High Water Alarm
Issued 14 September 2005
Resolved
Prove proper operation of visual bilge high level alarm IAW 46 CFR 182.530(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2005
Lifesaving › Hand Flares › Quantity
Issued 14 September 2005
Resolved
Prior to carrying passengers for hire, provide (4) additional orange hand smoke distress signals IAW 46 CFR 180.68(a)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 14 September 2005
Resolved
Provide an additonal adult PFD. Vessel is restricted to carriage of 13 passengers until requirement complete.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 15 September 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 September 2005
Resolved
Mark ring life buoy with vessels name IAW 46 CFR 185.604(b).
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 15 September 2005
Lifesaving › Lifebuoys › Serviceable
Issued 14 September 2005
Resolved
Replace grab line in way of ring life buoy.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 15 September 2005
Communications › Radio Communications › EPIRB
Issued 14 September 2005
Resolved
Replace hydrostatic release in way of 406 MHz EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2005
Communications › Radio Communications › EPIRB
Issued 14 September 2005
Resolved
Provide NOAA registration for 406 MHz EPIRB.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 15 September 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 September 2005
Resolved
Prove proper operation of fixed fire extinguishing alarms and shutdowns prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 November 2004
Resolved
Replace retroreflective tape on all adult lifejackets.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 1 December 2004
Resolution: Corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 10 November 2004
Resolved
Replace retro reflective tape on ring life buoy.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 1 December 2004
Resolution: Corrected.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 November 2004
Resolved
Replace lifeline and grabline in way of ring lifebuoy.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 1 December 2004
Resolution: Corrected.
Communications › Radio Communications › EPIRB
Issued 10 November 2004
Resolved
Provide current 406MHz EPIRB registration.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 1 December 2004
Resolution: Corrected.
Communications › Radio Communications › EPIRB
Issued 10 November 2004
Resolved
Make repairs to EPRIB antenna.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 1 December 2004
Resolution: Corrected.
Fire Fighting › Fire Bucket › Quantity
Issued 10 November 2004
Resolved
Provide (1) additional fire bucket.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 1 December 2004
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 November 2004
Resolved
Provide First Aid Kit in accordance with 46 CFR 184.710 prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Resolution: Corrected.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 November 2004
Resolved
Prove proper operation of audible and visual highwater alarms prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Resolution: Corrected.
Engineering › Bilge Water Management System › Not Operational
Issued 10 November 2004
Resolved
Prove proper operation of automatic bilge pumps prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 November 2004
Resolved
Service vessel's fixed fire extinguishing system and BII portable extinguisher prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Resolution: Corrected.
Communications › Alarms/Indicators › Fire Alarm
Issued 10 November 2004
Resolved
Prove proper operation of fixed fire extinguishing system automatic engine shutdown and alarm prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 November 2004
Resolved
Install Port and Starboard navigation lights and prove proper operation of the same prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Resolution: Corrected.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 November 2004
Resolved
Provide magnetic compass prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2004
Resolution: Corrected.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 November 2004
Resolved
Provide Emergency Instructions in accordance with 46 CFR 185.512.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 1 December 2004
Lifesaving › Hand Flares › Condition
Issued 24 July 2003
Resolved
Replace six expired signaling devices.
Action required: 705 - Other - as specified
Due 24 July 2003
Resolved 24 July 2003
Resolution: Were purchased before inspector returned to complete in-water portion of inspection.
Lifesaving › Lifebuoys
Issued 24 July 2003
Resolved
Provide one waterlight with three foot lanyard attached to lifebuoy with a corrosion resistant clip. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 August 2003
Resolved 13 November 2003
Resolution: Observed corrected.
Fire Fighting › Miscellaneous Items
Issued 24 July 2003
Resolved
Provide three 2.5 gallon fire buckets marked with vessel name and with an attached lanyard. LEGACY COMPONENT DESC: Fire Buckets
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 August 2003
Resolved 13 November 2003
Resolution: Observed corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 15 August 2002
Resolved
Provide proof that fixed and portable fire extinguishers have been serviced. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2002
Resolved 19 September 2002
Resolution: Corrected.
Communications › Radio Communications
Issued 15 August 2002
Resolved
Provide proof that vessel's EPIRB has been registered with NOAA. EPIRB was recently replaced by manufacture's warranty and NOAA registration decal was not found on EPIRB. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2002
Resolved 19 September 2002
Resolution: Corrected
Documentation › Certificates/Documents
Issued 15 August 2002
Resolved
Post vessel's Certificate of Inspection. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2002
Resolved 19 September 2002
Resolution: Corrected
Documentation › Certificates/Documents
Issued 15 August 2002
Resolved
Post vessel's stability letter. LEGACY COMPONENT DESC: Stability Letter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2002
Resolved 19 September 2002
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 August 2002
Resolved
Restencil location of adult and child life jackets. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2002
Resolved 19 September 2002
Resolution: Corrected
Construction/Loadline › Hull
Issued 15 August 2002
Resolved
Grind and re-glass fiberglass tabbing in way of forward engine room bulkhead, staboard side. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 September 2002
Resolved 19 September 2002
Resolution: Corrected satisfactorily
Navigation › Collision/Grounding Avoidance
Issued 15 August 2002
Resolved
Prove proper operation of navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 September 2002
Resolved 19 September 2002
Resolution: Corrected.
Engineering › Gasoline Engine (propulsion)
Issued 15 August 2002
Resolved
Remove previously installed power ventilation that is not connected to the fixed fire system. LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2002
Resolved 19 September 2002
Resolution: Corrected
Construction/Loadline
Issued 2 July 2001
Resolved
Make permanent repairs to delaminated fiberglass fillet joint in way of transverse frames where port and starboard fuel tanks are fastened in the vsl's engine compartment.
Condition: Unknown
Due 2 August 2001
Resolved 23 July 2001
Construction/Loadline
Issued 2 July 2001
Resolved
Make permanent repairs to transverse watertight bulkhead located approximately 119 inches fm vsl's transom in the engine compartment. Repairdelaminated fiberglass fillet joint where bulkhead meets the hull.
Condition: Unknown
Due 2 August 2001
Resolved 23 July 2001
Documentation
Issued 2 July 2001
Resolved
Provide proof of user fee payment._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 2001
Resolved 24 July 2001
Lifesaving
Issued 2 July 2001
Resolved
Replace (3) expired red hand flares with Coast Guard approved type prior tocarrying passengers
Condition: Unknown
Due 2 August 2001
Resolved 24 July 2001
Fire Fighting
Issued 2 July 2001
Resolved
Provide proof of annual servicing for fixed Halon system prior to carrying passengers.
Condition: Unknown
Due 2 August 2001
Resolved 24 July 2001
Construction/Loadline
Issued 2 July 2001
Resolved
Install plate or make other permanent repairs to restore watertight integrity of forward most engineroom bulkhead IWO vsl's battery switch.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Fire Fighting
Issued 2 July 2001
Resolved
Provide proof of annual servicing for all portable fire extinguishers priorto carrying passengers.
Condition: Unknown
Due 2 August 2001
Resolved 24 July 2001
Lifesaving
Issued 2 July 2001
Resolved
Install ignition interlock for exhaust blowers for gasoline engine IAW 46 CFR 182.460.
Condition: Unknown
Due 2 August 2001
Resolved 24 July 2001
Documentation
Issued 14 August 2000
Resolved
Provide original COI.
Condition: Unknown
Due 14 August 2000
Resolved 14 August 2000
Fire Fighting
Issued 14 August 2000
Resolved
Service portable extinguishers.
Condition: Unknown
Due 14 August 2000
Resolved 14 August 2000
Documentation
Issued 14 June 1999
Resolved
Provide licensed operator enrolled in a drug testing program.
Condition: Unknown
Due 14 June 1999
Resolved 14 June 1999
Lifesaving
Issued 14 June 1999
Resolved
Conduct fire and man overboard drills prior to operating.
Condition: Unknown
Due 14 June 1999
Resolved 14 June 1999