MAURY USCG vessel records
← All vessels

LA REINA

Built
1978
Last inspected
1 September 2020
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 1 September 2020
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 35 calendar years (1985–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8642488
Flag
UNITED STATES
Maury page id
psix-49596

Documentation record

Tonnage as PSIX records it7856 - Regulatory (Subpart C or D), Gross Ton
7856 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 70 inspections, each with its date, unit and type; 73 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CORINNE C Towing Vessel · MISLE 148486 · 16 August 2009 · activity 3601172CAPE HENLOPEN Towing Vessel · MISLE 119174 · 20 March 1996 · activity 50077CENTURION Towing Vessel · MISLE 142498 · 20 March 1996 · activity 50077PIONEER Towing Vessel · MISLE 136422 · 25 February 1996 · activity 86813

Inspection history · 70

1 September 2020 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7047516
29 April 2019 MTSA/ISPS Verification · Periodic Inspection · MARPOL Annex I Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6672346
8 June 2018 Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6434629
21 June 2017 Administrative Inspection · MARPOL Annex I Examination · COI Inspection · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6182309
12 July 2016 Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5937269
4 December 2015 Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5775316
2 September 2015 MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5233793
11 September 2014 Annual Inspection · MARPOL Annex I Examination · Deficiency Check · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4989226
30 July 2014 Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4938701
26 August 2013 MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4697399
30 July 2013 MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4669544
4 June 2012 COI Inspection · Drydock Exam · Internal Structural Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4302119
5 April 2012 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4280016
11 June 2010 MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3762671
29 September 2009 Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3605499
16 August 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3601172
1 April 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3442794
13 April 2008 MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3182210
1 February 2008 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3140423
14 August 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3027935
2 May 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2920703
17 March 2006 Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2604463
6 July 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2417313
21 June 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2397463
18 March 2005 MTSA Verification · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2313654
18 August 2004 Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2169880
25 June 2004 Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2113336
29 May 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2081423
28 May 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2120902
6 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2003597
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978216
4 April 2003 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1762783
12 November 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1704361
29 July 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1653731
3 July 2001 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1401514
2 May 2000 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1439014
9 August 1999 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1406538
9 December 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 809074
11 November 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 805800
18 August 1997 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437285
29 April 1997 Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1388277
23 April 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 932555
20 March 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 50077
19 March 1996 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1081491
29 February 1996 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1355675
25 February 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 86813
11 July 1995 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1422534
16 January 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1419360
7 December 1994 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 854838
7 November 1994 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1148381
16 August 1994 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1181831
29 May 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1170888
25 February 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 444198
26 July 1993 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1161547
13 July 1992 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 848586
13 July 1992 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1268333
3 June 1992 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 947508
21 June 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1212931
13 June 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 924226
3 November 1989 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1336848
28 June 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1207758
29 June 1988 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1206306
17 July 1987 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1012532
16 January 1987 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1007803
10 November 1986 Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1014963
14 August 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 986245
25 July 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1293293
3 July 1986 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1299381
26 July 1985 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291252
25 July 1985 Initial Construction-Excluding Oversight
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 983331

Deficiency record · 73

Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 June 2017 Resolved
Make permanent repairs to tops of diagonal braces (at overhead) at Frame 28 and Frame 34 on the 1st Deck (Tween deck).
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 5 August 2017
Stability › Watertight Integrity › General
Issued 11 September 2014 Resolved
Crop and renew #5 & #8 stbd side tank hatches.
Due 11 October 2014
Resolved 9 October 2014
Resolution: Stainless hatches have been welded in place.
Construction/Loadline › Markings › Load Line Mark
Issued 11 September 2014 Resolved
Paint loadline markings a contrasting colow to the hull.
Due 11 October 2014
Resolved 9 October 2014
Resolution: Load line line markings painted white.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
Forepeak starboard of CVK crop and renew along Frame #2. 5x2 insert.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
Forepeak starboard/port of CVK gouge and weld 09 fractures as marked.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#1 starboard void - Gouge and weld fracture along #6 Frame as marked.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#1 Starboard center void - Crop and renew along #6 Frame on transverse stiffener as marked.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#1 Starboard center void - Crop and renew between transverse frame and bottom plate along Frame #7 and Frame #8.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#1 port center void - Crop and renew bulkhead #5 along vertical flange as marked.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#1 port void - Crop and renew #6 Frame along existing damage and sideshell and longitudinal stiffeners.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#3 starboard void - Crop and renew fracture along Frame 20 Diagonal.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 31 July 2014
Resolution: Repairs all satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#3 starboard void - Crop and renew starboard upper tripping bracket #19 Frame. Along Frames 18, 19, 20, 21, and 22 back gouge and reweld fractures as marked.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2014
Resolution: Repairs all satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#3 starboard void - Gouge and weld 02 fractures along port side bulkhead as marked.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 31 July 2014
Resolution: Repairs all satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#4 port center - Gouge and weld along bulkhead and fractured frame #27.
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 July 2014 Resolved
#5 starboard void - Gouge and weld fracture along bottom longitudinal on Frame #30.n
Condition: Damaged By Earlier Event
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 July 2014 Resolved
Remove cable tray along Frame #18 on Main Deck, Port Side.
Condition: Improper/Lack of Maintenance
Due 1 September 2014
Resolved 1 August 2014
Resolution: All Satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2009 Resolved
Properly repair bare electrical calbe at frame 10 on main deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2009
Resolved 10 April 2009
Resolution: Cable spliced inside of plastic junction box. All Sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2009 Resolved
Shore tie cable between frames 9 and 10 on main deck is burnt. Test cable for shorts/grounds and insulate back to original insulation value.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: Shore tie was meggered and properly wrapped. All Sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2009 Resolved
Properly hang all electrical cables throughout the vessel in accordance with IEEE-45
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: All cables properly hung.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 April 2009 Resolved
Fix all inop lights throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: New light fixtures installed where needed, new light bulbs etc. All Sat.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 April 2009 Resolved
Secure loose electrical service plug at frame 49 on main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: Service plug properly removed. All Sat.
Electrical › Electric Generation Source (service) › Conductor
Issued 1 April 2009 Resolved
Remove all dead end wires on both SSDG's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: All wires properly removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2009 Resolved
Remove all dead ended cables in overhead just above SSDG's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: Dead end cables properly removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 April 2009 Resolved
Missing light fixture on tow bit deck on starboard side forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: New light fixture installed. All Sat.
Deck/Cargo › Cargo Stowage › General
Issued 1 April 2009 Resolved
Remove or Renew all wasted D-rings on upper deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: All old D rings removed. All Sat.
Construction/Loadline › Hull › Girder
Issued 1 April 2009 Resolved
Insert two vertical stanchionsand repair welds as needed at frame 57 on 2nd deck port side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: One stanchion inserted and other repaired. All Sat.
Construction/Loadline › Hull › Girder
Issued 1 April 2009 Resolved
Crop and Renew bottom of diagonal back to good metal, the first on inboard on the ports side of 2nd deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: Diagonal properly inserted. All Sat.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 1 April 2009 Resolved
Crop and renew 2 pilot ladder rungs on port side forward ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: New ladder rungs installed. All Sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 April 2009 Resolved
Crop and renew wasted hand rail on port side of pilot house platform. Also reattach hand rail stanchion on starboard side of pilot house platform.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 10 April 2009
Resolution: New section of hand rail properly renewed, stanchion reattached, All Sat.
Documentation › Certificates/Documents › IOPP Certificate
Issued 11 April 2008 Resolved
Expired IOPP Cert, in process of issuing new certificate to vessel from Sector Delaware Bay.
Action required: 705 - Other - as specified
Due 23 April 2008
Resolved 23 April 2008
Resolution: Issued signed IOPP to owner rep
Construction/Loadline › Hull › Weld
Issued 11 April 2008 Resolved
Repair weld fractures on window frame on port side by #38 frame. Also repair deck weld fracture by #47 frame on STBD side at cleat opening.
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 28 April 2008
Resolution: Received email with photos of repair from vessel rep. Repair sat.
Stability › Watertight Integrity › Coaming
Issued 11 April 2008 Resolved
Manhole cover and coaming wasted by sea spray by #49 frame on the port side beyond acceptable wastage limits. Vessel rep said he intends to replace it.
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 28 April 2008
Resolution: Vessel Rep emailed photos of repair. Former manhole coaming and cover had been cropped and replaced with a new assembly
Electrical › Lighting (service) › Conductor
Issued 2 May 2007 Resolved
Properly replace wire hangers as noted on the first and 2nd deck
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 29 May 2007
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Cylinder Liner
Issued 2 May 2007 Resolved
Properly replace the lube oil sensing line on the outboard generator.
Due 3 May 2007
Resolved 4 May 2007
Electrical › Electrical Distribution System (service) › Switch
Issued 25 June 2004 Resolved
Properly secure controller switch for ballast pump.
Due 25 July 2004
Resolved 22 July 2004
Electrical › Electric Generation Source (service) › Panelboard
Issued 25 June 2004 Resolved
Provide means to secure electrical panel on portside main deck, in vicinity of frame 46.
Due 25 July 2004
Resolved 22 July 2004
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 25 June 2004 Resolved
Replace gasket on void tank #2 hatch on portside main deck.
Due 25 July 2004
Resolved 22 July 2004
Electrical › Electric Generation Source (service) › Generator
Issued 25 June 2004 Resolved
Prove proper operation of #2 generator.
Due 25 July 2004
Resolved 22 July 2004
Resolution: Tested generator under load, all sat.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 June 2004 Resolved
Install cover on electrical panel forward of generator.
Due 25 July 2004
Resolved 22 July 2004
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 June 2004 Resolved
Prove proper operation of ground fault indicators.
Due 25 July 2004
Resolved 22 July 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 June 2004 Resolved
Remove unsused electrical outlet boxes throughout vessel.
Due 25 July 2004
Resolved 22 July 2004
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 25 June 2004 Resolved
Secure and label controllere near house on second deck.
Due 25 July 2004
Resolved 22 July 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 June 2004 Resolved
Provide missing caps for outlets throughout vessel.
Due 25 July 2004
Resolved 22 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 June 2004 Resolved
Provide proper support for wire runs throughout vessel.
Due 25 July 2004
Resolved 22 July 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 25 June 2004 Resolved
Remount or remove broken deck lights on upper deck.
Due 25 July 2004
Resolved 22 July 2004
Resolution: Removed redundant lighting on upper deck.
Electrical
Issued 11 November 1998 Resolved
Repair/replace drip guards to electrical service boxes, second deck forward.
Condition: Unknown
Due 11 November 1998
Resolved 11 November 1998
Lifesaving
Issued 11 November 1998 Resolved
Replace 2 missing safety chains on second deck ladderways.
Condition: Unknown
Due 11 November 1998
Resolved 28 November 1998
Lifesaving
Issued 11 November 1998 Resolved
Crop and renew 10 feet of wasted handrail in way of third deck, stbd aft.
Condition: Unknown
Due 11 November 1998
Resolved 28 November 1998
Engineering
Issued 11 November 1998 Resolved
Remove/clean excess oil under electrical service generators.
Condition: Unknown
Due 11 November 1998
Resolved 11 November 1998
Construction/Loadline
Issued 11 November 1998 Resolved
Crop and renew 2 identified areas of through-deck wastage: _x001C_ a) third deck, aft centerline _x001C_ b) third deck, stbd midlength
Condition: Unknown
Due 11 November 1998
Resolved 11 November 1998
Construction/Loadline
Issued 11 November 1998 Resolved
Crop and insert deckplate to third deck, "B" lane, supporting 6th trailer stand aft. Re-attach supporting cross underframe.
Condition: Unknown
Due 11 November 1998
Resolved 11 November 1998
Construction/Loadline
Issued 11 November 1998 Resolved
Crop and insert deckplate to third deck "A" lane, 2nd trailer stand aft.
Condition: Unknown
Due 11 November 1998
Resolved 11 November 1998
Electrical
Issued 29 April 1997 Resolved
Provide proper splice to electrical wiring extension located overhead on second deck portside aft.
Condition: Unknown
Due 29 May 1997
Resolved 21 May 1997
Electrical
Issued 29 April 1997 Resolved
Close overhead electrical junction boxes on second deck: Fr 11/12 portside,Fr 35/36 portside, Fr 44/45 portside.
Condition: Unknown
Due 29 May 1997
Resolved 21 May 1997
Lifesaving
Issued 29 April 1997 Resolved
Provide safety chain to ladderway located on second deck stbd, Fr 52/53.
Condition: Unknown
Due 29 May 1997
Resolved 21 May 1997
Lifesaving
Issued 29 April 1997 Resolved
Repair broken deck welds to third deck railings, port/stbd.
Condition: Unknown
Due 29 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 29 February 1996 Resolved
COMPLETE TEMPORARY REPAIR TO MAIN DECK PRIOR TO SAILING. INSTALL A WELDED DOUBLER OVER THE 4 IN. X 10 IN. HOLE IN THE MAIN DECK.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 29 February 1996 Resolved
CROP AND RENEW FR. 59 GIRDER FROM THE MAIN DECK TO 18 IN. ABOVE THE 01 DECKTO ORIGINAL SCANTLINGS.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 29 February 1996 Resolved
CROP AND RENEW SHEAR STRAKE FROM FASHION PLATE BUTT JOINT DOWN 18 IN. BELOWMAIN DECK FROM OUTBOARD STERN BUTT JOINT OUTBOARD AROUND THE CORNER TO SIX FOOT FORWARD OF THE STERN TO ORIGINAL SCANTLINGS.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 29 February 1996 Resolved
COMPLETE THE FOLLOWING TEMPORARY REPAIR PRIOR TO SAILING: INSTALL A TEMPORARY STANTION IN WAY OF FR. 59 STBD, FROM THE MAIN DECK TO THE 01- DECK.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 29 February 1996 Resolved
COMPLETE THE FOLLOWING TEMPORARY REPAIR PRIOR TO SAILING: CUT AWAY THE BUCKLED FASHION PLATE AND FR. 59 GIRDER.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 29 February 1996 Resolved
CROP AND RENEW FASHION PLATE FROM SHEAR STRAKE BUTT JOINT TO 18 IN. ABOVE 01-DECK, STERN TO 6 FT FROM STERN, AND ALL ASSOCIATED STIFFENERS, TO ORIGINAL SCANTLINGS.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 29 February 1996 Resolved
COMPLETE THE FOLLOWING TEMPORARY REPAIR PRIOR TO SAILING: DRILL STOP THE 6 IN. FRACTURE AFT OF FR. 59 IN THE MAIN DECK.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Deck/Cargo
Issued 29 February 1996 Resolved
REMOVE TRAILER STAND J-1, 01-DECK, UNTIL SUCH TIME AS PERMANENT REPAIRS ARECOMPLETE.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 29 February 1996 Resolved
CROP AND RENEW THE MAIN DECK, 36 IN. X 36 IN. MINIMUM, IN WAY OF THE STERN TO FR. 59, TO ORIGINAL SCANTLING.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 16 August 1994 Resolved
MAKE PERMENANT REPAIRS TO THE DAMAGE IWO OF THE STERN VOID HEAD LOG, PORT SIDE AT THE CORNER. MAINTAIN TEMPORARY REPAIRS UNTIL PERMENANT REPAIRS ARE MADE TO THE SATIFACTION OF THE COGNAIZANT OCMI.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Documentation
Issued 13 July 1992 Resolved
PROVIDE APPROVED PLANS FOR ALTERATIONS IN #1 VOID, IN WAY OF TRANSVERSE FRAMES #6-9, PORT AND STBD BAYS FROM CVK. PLANS SHALL INCLUDE DESCRIPTION OF PROBLEM THAT INSTIGATED ALTERATIONS, MARINE ARCHITECT'S DRAWINGS AND CALULATIONS.
Condition: Unknown
Due 13 July 1992
Resolved 13 July 1992
Construction/Loadline
Issued 10 November 1986 Resolved
#2 VOID PORT SIDE FWD. CROP AND RENEW INSERTS IN FWD. BULKHEAD AT SIDE SHELL AND NEXT SIDE WEB FR.AFT. SAME LOCATION RENEW THE CORNER BRACKET AND INSERT THE LONGITUDNALS AS NECESSARY.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 10 November 1986 Resolved
#3 VOID PORT SIDE VEE AND WELD FRACTURE AS MARKED , MIDWAY OF COMPT. AT SIDE SHELL .
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 10 November 1986 Resolved
VEE AND WELD FRACTURES THRU MAIN DECK AT FRAME #53 PORT AND STBD. SIDES (JUST AFT OF FWD. BULKHEAD OF AFT. RAKE).
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 10 November 1986 Resolved
#4 VOID STBD. SIDE FWD. OF #2 DEEP SIDE WEB FRAME FAIR AND WELD BROKEN SIDE SHELL "LONG.".
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 10 November 1986 Resolved
AFTER RAKE COMPARTMENT PORT AND STBD. SIDES CROP AND RENEW DAMAGED "HEAD- LOG" VERTICAL STIFFNERS AS MARKED.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Unknown
Issued 3 July 1986 Resolved
MAKE REPAIRS TO THE OVERSPEED TRIPS ON BOTH DIESEL GENERATORS AND CONDUCT AN OPERATIONAL TEST TO THE SATISFACTION OF A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.