Records from 2014 to 2026. Most recent: inspection, 27 April 2026.
Documentation record
Registered dimensions (L × B × D)61.6 ft × 20.8 ft × 6.4 ft
Registered tonnagegross 81 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYANK BOAT WORKS · TUCKAHOE, NJ, UNITED STATES · built 1978
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT JEFFERSON, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
27 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8357725
9 December 2025
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8278930
8 April 2025
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8091224
17 April 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7896709
14 December 2023
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7838908
20 April 2023
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7658249
20 April 2022
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7411379
15 December 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7367090
23 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7196884
8 July 2020
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6953703
6 December 2019
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6865498
6 June 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6643320
11 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6361768
8 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6366127
14 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6124283
12 April 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5852183
10 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5830109
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 April 2025
Resolved
Prior to carrying passengers conduct underway drills with attending Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2025
Resolved 21 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 April 2025
Resolved
Check connections to weak link for life floats.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2025
Resolved 21 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 April 2025
Resolved
Re-coat and relabel life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 21 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2025
Resolved
Properly configure machinery guards in engine room to prevent personal injury.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 21 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 8 April 2025
Resolved
Properly secure ladder in crew quarters.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 21 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2025
Resolved
Replace 02 adult life jackets.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2025
Resolved 21 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2024
Resolved
Provide 1 child PFD.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2024
Resolved 19 April 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 April 2024
Resolved
Prove proper operation of bilge high water alarm in forepeak.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2024
Resolved 19 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 20 April 2023
Resolved
Replace Hydrostatic Release for EPIRB prior to operating
outside 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 21 April 2023
Resolution: Owner purchased new hydrostatic releases.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2023
Resolved
Repair exhaust lagging on starboard main.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 8 June 2023
Resolution: Lagging repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2023
Resolved
Replace bilge handle on valve in space #2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2023
Resolved 8 June 2023
Resolution: Bilge handle replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2023
Resolved
Replace battery in life ring light, or replace with new
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2023
Resolved 8 June 2023
Resolution: New ring light purchased.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 April 2023
Resolved
Repair fixed CO2 system as discussed with vessel
representatives and provide service report.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2023
Resolved 21 April 2023
Resolution: CO2 system is repaired.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 April 2021
Resolved
Complete underway emergency drills and operational test prior to operating with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2021
Resolved 7 May 2021
Resolution: MI attended vessel and cleared requireent.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 December 2019
Resolved
Vessel is FRP over plywood, where delamination was discovered where an old transducer was mounted. Rrepair hull delamination to original lament schedule.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2020
Resolved 11 December 2019
Resolution: Inspected and cleared hull repair requirement issued after proper repair was completed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 April 2016
Resolved
10 PFD's failed examination (clips did not work). Boat capacity as follows until PFD's are replaced. 109 pax, 3 crew (112 total persons)
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 19 April 2016
Resolution: purchased new PFD's. restriction taken off.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 12 April 2016
Resolved
Provide 12 flares at operating station. 6 red, and 6 orange OR 12 red. 46 CFR 180.68
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 15 April 2016
Resolution: 12 Hand red flares provided on board.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 April 2016
Resolved
Prove proper test of VHF-DSC radio with MMSI number.
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 21 April 2016
Construction/Loadline › Hull › Stiffener
Issued 10 March 2016
Resolved
Submit proposal for portside bulkhead in way of old passenger access gate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 17 March 2016
Resolution: (02)Bulwark stanchions were removed and replace with new wooden stanchions. Strucural integrity of the railing in the affected area was satisfactory.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 10 March 2016
Resolved
Repair delamination on starboard side bow at the vessels name.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 17 March 2016
Resolution: Operator drilled pilot holes in the affected area and filled with West System epoxy. Found this to be acceptable repair as the area was non structurual external bulwark skin.