Records from 1982 to 2006. Most recent: operational control imposed, 9 February 2006.
Inspection history · 27
9 February 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2601347
7 February 1997
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 400404
8 December 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1143976
5 December 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 871277
1 March 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1166769
30 November 1993
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450811
14 November 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252358
23 May 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316880
27 June 1990
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930160
18 June 1990
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211690
21 May 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1223710
10 April 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901765
20 March 1989
MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349425
14 October 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199665
30 September 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044020
30 September 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1195483
23 September 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1043896
22 April 1988
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1346898
10 September 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316676
19 June 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315915
27 May 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336333
14 March 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306657
18 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297564
25 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992878
12 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285342
7 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970800
26 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271381
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 9 February 2006
No resolution recorded
Vessels starboard engine gear box was reported inoperable.
Action required: 705 - Other - as specified
Due 11 February 2006 — due date passed with no resolution recorded
Resolution: Received report from class society attesting to proper repair and operation.
Deck/Cargo
Issued 30 November 1993
Resolved
PRIOR TO PLACING IN SERVICE, RENEW MANWAY HATCHES OF BOTH PORT DRY BULK_x001C_ PRESSURE VESSELS WITH ASME-CERTIFIED PARTS TO THE SATISFACTION OF THE_x001C_ ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Construction/Loadline
Issued 23 May 1991
Resolved
EFFECT REPAIRS TO AFT RUBRAIL PORT/STBD TO SEAL DAMAGED AREAS.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Construction/Loadline
Issued 10 April 1990
Resolved
MARK STERN OF VESSEL WITH HAILING PORT IAW 46CFR67.13-7
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Engineering
Issued 10 April 1990
Resolved
PROVIDE FOR APPROVAL AND PLACE ON BOARD VESSEL AN APPROVED AUTOMATION CONTROL/MONITORING SYSTEM TEST PROCEDURES AND/OR MAINTANCE PROCEDURES IAW [name withheld] AND NVIC 1-81 CH1.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Documentation
Issued 22 April 1988
Resolved
PROVIDE MARINE DOCUMENTATION CERTIFICATION.
Condition: Unknown
Due 22 April 1988
Resolved 22 April 1988
Navigation
Issued 22 April 1988
Resolved
PROVIDE CERTIFICATE OF ALTERNATIVE COMPLIANCE FOR AFT MASTHEAD LIGHT.
Condition: Unknown
Due 22 April 1988
Resolved 22 April 1988
Engineering
Issued 10 September 1987
Resolved
REPAIR AND MAKE OPERATIONAL ENGINE RPM TACHS LOCATED ON BRIDGE.
Condition: Unknown
Due 10 September 1987
Resolved 10 September 1987
Deck/Cargo
Issued 25 July 1985
Resolved
PRIOR TO PLACING VESSEL IN SERVICE PROVIDE THE SECOND ANCHOR (STARBOARD SIDE), ANCHOR CHAIN, AND BRAKE ASSEMBLE.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Lifesaving
Issued 25 July 1985
Resolved
REPLACE THE NON APPROVED FISHER MARINE RESCUE BOAT WITH AN APPROVED RESCUE BOAT.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Navigation
Issued 25 July 1985
Resolved
PROVIDE A LIGHT FOR THE GYRO COMPASS OR REMOVE THE GYRO COMPASS.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985