Records from 2016 to 2025. Most recent: inspection, 25 March 2025.
Documentation record
Registered dimensions (L × B × D)41.5 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAUSALITO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 12 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
25 March 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8099240
13 March 2025
Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8092438
2 April 2024
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7878698
15 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7686796
3 April 2023
Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7661966
7 February 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7633347
16 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7610274
5 April 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7422462
14 July 2021
Plan Review "T" Boat · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7248590
24 May 2021
Simplified Stability Test · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7205612
22 March 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7161031
15 March 2021
Hull Examination · Plan Review "T" Boat · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7156364
15 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939244
26 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6646999
11 March 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6640076
22 March 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6376976
28 March 2017
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6112574
28 February 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6096503
10 March 2016
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5831066
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 March 2025
Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 760 millimeters (30 inches) and subject to pressures of not more than 35 kPa (5 psig), may meet the following requirements...Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. MI identified section of flexible hose on the generator which did not have sufficient double clamping.
46 CFR 182.720(e)(3)(v)(B)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 8 April 2025
Resolution: Operator provided photo to rectify deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 March 2025
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection and testing of all smoke and fire detection systems, including sensors and alarms. MI identified a smoke detector in the wheelhouse with a faulty battery.
46 CFR 176.810(a)(7)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 8 April 2025
Resolution: Operator replaced battery; provided video to rectify.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 March 2025
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirement: Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Provide proof marine radio operator permit to MI.
47 CFR 80.159 (e)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 9 April 2025
Resolution: Operator provided proof of marine radio operator permit.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 March 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI identified expired first aid kit; secondary first aid kit was also missing some of the required contents. A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12.
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 8 April 2025
Resolution: Operator replaced first aid kit; provided photo to rectify.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 March 2025
No resolution recorded
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids,... A crack was found across the wood stiffener between the center hatch and port engine hatch near the forward end where a cut had been made to install the new engines. Present acceptable proposal for permanent repair and make corrections prior to credit of next drydock 2027. 46 CFR 176.610(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 March 2025 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 March 2025
Resolved
A hatch exposed to the weather must be watertight. Water intrusion was found through a crack between the center hatch and port engine hatch where a cut had been made through wood stiffener to install the new engines. Prior to credit drydock, waterproof to mitigate water intrusion to wood stiffener pending permanent repair. 46 CFR 179.360(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 March 2025
Resolved 14 March 2025
Resolution: Operator emailed photo evidence of arresting water intrusion with FlexPoxy product.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 March 2025
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI observed a cable transit pipe on upper starboard corner of bulkhead in lazarette that was not watertight. 46 CFR 179.320(c)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2025
Resolved 14 March 2025
Resolution: Operator emailed photo of cable transit made water tight with closed cell expanding foam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI identified a dead end wire in the upper starboard corner of the lazarette. Remove or terminate prior to credit drydock. 46 CFR 183.200(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 March 2025
Resolved 14 March 2025
Resolution: Operator emailed photo evidence that dead end wire is removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Fire buckets were too large. Make fire buckets 2.5 gallons, to the satisfaction of the marine inspector. 46 CFR 181.610
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 17 May 2023
Resolution: Made new fire buckets and labeled.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 15 May 2023
Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate, or equivalent construction. Hole found between engine room and accomodation space. Make hole vapor tight to the satisfaction of the marine inspector. 46 CFR 182.35-1
"OLD T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 19 May 2023
Resolution: Made hole vapor tight.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 May 2023
Resolved
For fixed-gas fire extinguishing systems...The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Owner did not have servicing report for Fireboy system. Provide report to marine inspector.
46 CFR 176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 19 May 2023
Resolution: Provided report. Hydrostatic test and annual testing completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2022
Resolved
An adult life jacket must be provided for each person carried on board the vessel. 09 kapok life jackets were found to be unserviceable and need to be replaced. Vessel currently has 21 Adult life jackets on board. Personnel allowance on board the vessel while underway shall be reduced to 21 persons until remainder of appropriate life jackets is obtained.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 6 April 2022
Resolution: Replaced all worn lifejackets. SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2022
Resolved
Electrical equipment used in a machinery space must be drip proof. 02 plug in outlets in the fwd machinery space need covers to protect the outlets from moisture.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 12 April 2022
Resolution: Recieved picture of weather proof outlet covers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2021
Resolved
A pre-engineered fixed fire extinguishing system must automatically shut down all engines that draw intake air from within the protected space. Fire-boy did not shut down port and starboard engine.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 9 June 2021
Resolution: Vessel replaced solenoid on port and starboard engine for Fire-Boy system. Successfully completed Fire-Boy shut down and override test.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 March 2021
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and applies with all applicable regulations.
Vessel not cleared to carry passengers. Operator notified dispatch that the vessel will not be ready by COI renewal date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2021
Resolution: Completed COI inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 March 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment. Operator installed new engines and generator without approval from the OCMI.
46CFR176.700(a)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2021
Resolution: Received MSC plan approval letters for new installations of repower. Conducted sea trial and successful DVTP's.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 March 2018
Resolved
Remove oxidation or replace port/stbd navigation light lenses.
Action required: 705 - Other - as specified
Due 22 April 2018
Resolved 23 March 2018
Resolution: Port/stbd nav light lenses replaced.
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 March 2016
Resolved
Provide shields for the port & stbd emergency fuel shutoff valves which isolate the valve handle from the protected space. 46 CFR 182.455(b)(4)
Condition: Design Flaw
Due 22 April 2016
Resolved 21 April 2016
Resolution: Operator had local shipyard install metalic flame sheilds.