MAURY USCG vessel records Sign in
← All vessels

ESMERALDA

ESMERALDA is a 1999 freight ship. The Coast Guard has recorded 10 inspections since 1999, most recently in January 2019, along with 4 deficiencies.

Records from 1999 to 2019. Most recent: inspection, 23 January 2019.

Built
1999
Last inspected
23 January 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9181170 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA3564
496105
Flag
LIBERIA
—
Maury page id
psix-496105

Inspections, by type

…with no type recorded4
Years with a record 6 calendar years (1999–2019)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it19077 - Displacement, Metric Ton
10532 - Convention (Subpart B), Gross Ton
12735 - Dead Weight, Metric Ton
5406 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

23 January 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6614032
26 February 2005 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2299657
28 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2266004
16 July 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2134999
8 March 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2020343
6 February 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2001818
6 January 2004 Deficiency Check · Administrative Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1975932
9 December 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1961023
5 December 2002 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1716222
7 June 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 429320

Deficiency record · 4

Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 26 February 2005 Resolved
Emergency Generator Start/ mode of operation switch broke/missing. Cite: Solas 74/78 Chapter II-1 Reg 26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2005
Resolved 27 February 2005
Resolution: Recieved class report attesting to correction of deficiency.
Engineering › Lubricating Oil Service System › Piping
Issued 26 February 2005 Resolved
Lube oil purifier steam line fractured. Cite: Solas 74/78 Chapter II-1 Reg 26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2005
Resolved 27 February 2005
Resolution: Recieved class report attesting to correction of deficiency.
Fire Fighting › Ventilation Systems › Fans
Issued 26 February 2005 Resolved
Ventilation system in CO2 room inoperative. Cite: Solas 74/78 Chapter II-1 Reg 26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2005
Resolved 27 February 2005
Resolution: Recieved class report attesting to correction of deficiency.
Fire Fighting › Firemans Outfit
Issued 9 December 2003 Resolved
Fireman's outfit reflective shield wasted. LEGACY COMPONENT DESC: Protective Clothing
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 January 2004
Resolution: Received receipt of purchase for a complete fireman''s outfit. Def. cleared.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.