MAURY USCG vessel records Sign in
← All vessels

OCEAN EXPLORER

OCEAN EXPLORER is a 1978 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1984, most recently in July 2026, along with 81 deficiencies.

Records from 1984 to 2026. Most recent: inspection, 20 July 2026.

Built
1978
Last inspected
20 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI5556
Flag
UNITED STATES
367709770
Maury page id
psix-49614

Inspections, by type

…with no type recorded7
Years with a record 41 calendar years (1984–2026)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)75.2 ft × 20.7 ft × 6.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYANK BOAT WORKS · TUCKAHOE, NJ, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELMAR, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9382MMSI 367709770 · active · compulsorily equipped · granted 29 April 2026, expires 29 April 2036
WDI5556MMSI 367709770 · expired · compulsorily equipped · granted 9 January 2016, cancelled 14 March 2026
WDC9875MMSI 367107840 · expired · compulsorily equipped · granted 19 April 2006, cancelled 25 June 2016
WCX2280MMSI not assigned · expired · compulsorily equipped · granted 22 January 1997, cancelled 24 March 2007 · licensed under a name not among this hull’s recorded names (not shown)
WCW3532MMSI not assigned · expired · compulsorily equipped · granted 25 March 1996, cancelled 27 May 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 86

20 July 2026 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8442455
4 May 2026 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8343712
20 March 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319039
28 March 2025 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8101221
11 March 2025 COI Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8090996
22 May 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7917452
4 March 2024 Drydock Exam · Plan Review "T" Boat · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7870437
7 March 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7647117
6 December 2022 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7605188
24 August 2022 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7542221
4 May 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7444102
27 April 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7438273
4 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7188403
24 September 2020 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7068005
4 July 2020 Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 6996814
11 March 2020 Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6920724
26 March 2019 Administrative Inspection · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6649164
5 March 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6639031
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6506163
2 March 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6364869
8 May 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6141683
8 May 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6281484
27 March 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6110908
1 March 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5824261
5 February 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5810212
1 October 2014 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5048112
17 March 2014 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4813965
22 February 2012 Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4249069
24 February 2011 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3951123
18 October 2010 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3872351
2 March 2010 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3688275
21 March 2009 Type not recorded
No type recorded · Station Sandy Hook · USCG Northeast District (CGD-NE) · Activity 3437648
24 February 2009 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3422211
15 May 2008 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3206284
30 May 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2961587
28 February 2007 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2877896
16 May 2006 Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2649764
28 March 2005 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2319317
15 February 2005 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2293729
25 March 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2033170
13 May 2003 Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1791990
10 February 2003 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1742559
27 March 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1598086
28 March 2001 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1061522
1 March 2001 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1058015
13 March 2000 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1047295
4 October 1999 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1044944
30 March 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1120697
10 March 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 803634
8 January 1999 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 811406
14 April 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789327
20 March 1997 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1092227
24 January 1997 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1107264
21 March 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1078292
21 July 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1190029
12 May 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 894406
15 February 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 843600
15 February 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1156184
1 August 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1172800
22 July 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 864266
25 March 1994 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 856023
3 January 1994 Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1161643
22 July 1993 Deficiency Check · COI Inspection · Drydock Extension
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1152547
24 July 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1263548
13 December 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1266539
26 August 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1246384
26 July 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1245215
30 August 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1230794
27 July 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 931112
14 June 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 916254
11 October 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1336203
1 September 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1303467
18 August 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1352129
28 July 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1352476
13 March 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 896402
29 July 1988 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1347762
13 January 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1318305
22 December 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1317621
24 September 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017994
29 July 1987 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1339152
24 September 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005191
25 August 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296505
29 July 1986 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 995148
25 March 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1307951
29 July 1985 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296084
20 November 1984 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 974613

Deficiency record · 81

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 March 2025 Resolved
Documentation could not be provided showing the EPIRB on board has been registered with NOAA. Provide documentation showing EPIRB registration. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 7 April 2025
Resolution: Provided new registration
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 March 2025 Resolved
Master on board was unable to provide a valid FCC radio operator license. Provide valid operator license. 47 CFR 80.159(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 25 March 2025
Resolution: Provided picture of FCC Radio Operator Permit
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 March 2025 Resolved
Master on board was unable to provide a valid medical certificate. Provide valid medical certificate. 46 CFR 10.301(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 28 March 2025
Resolution: Provided picture of valid Medical Certificate
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 March 2025 Resolved
Vessel did not have up-to-date charts on board. Provide proof of updated or corrected charts. 46 CFR 184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 7 April 2025
Resolution: Provided photo of new charts
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 March 2025 Resolved
Vessel did not have any portable lights located at operating station or the access to machinery space. Provide portable lights in required spaces. 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 28 March 2025
Resolution: Provided picture of reciept and lights
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2025 Resolved
12 adult life jackets had deteriorated or improper retro-reflective material. Replace with approved Type I retro-reflective material. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 7 April 2025
Resolution: Provided new photo of new retro
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2025 Resolved
03 life jacket lights were inoperable. Replace inoperable lights with approved life jacket lights. 46 CFR 180.75
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 7 April 2025
Resolution: Provided Photo of new retro and lights
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 March 2025 Resolved
Vessels generator wet exhaust system is missing insulation at manifold and the exhaust piping prior to cooling water injection. Provide suitable insulation on required area. 46 CFR 177.10-5(b) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 28 March 2025
Resolution: Provided picture of installed insulation on exhaust piping
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2025 Resolved
Dead-end wiring above the starboard main engine was left unsecured. Secure loose wiring properly or remove if not in use. 46 CFR 183.05-50(b)(1) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 7 April 2025
Resolution: provided photo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2025 Resolved
Belt driven pump on port main engine did not have protective guard to protect from hazards. Provide a suitable guard around belt driven pump to protect personnel from rotating machinery. 46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 7 April 2025
Resolution: Provided photo of new guard
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 March 2025 Resolved
The owner of a vessel subject to inspection under Section 3301 shall record in a log book information on all access and use of the vessel's master key, including A)dates and times of access; B)the room or location accessed; and C)the name and rank of the crew member that used the master key. Vessel had no record log for master key control. Provide master key control as required. 46 USC 3106
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 7 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2024 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16).The attending marine inspector identified all three ring bouys had degraded retro reflective tape. Attach retro reflective tape to the ring bouy as specified.
Action required: 10 - Deficiency Rectified
Resolved 23 May 2024
Resolution: Operator put sufficient retroreflective tape around the body of the ring bouys.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 March 2024 Resolved
Vessel has crack around main deck handrail stanchion on port stern. Provide repair proposal.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 March 2024
Resolved 16 May 2024
Resolution: Prior to credit dry dock. Vessel has repaired handrail IAW repair plan.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 March 2024 Resolved
While performing exam MI discovered a wasted junction box mounted to mast. Replace wasted junction box.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 March 2024
Resolved 16 May 2024
Resolution: Prior to credit drydock. Vessel has repaired junction box IAW repair plan.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 March 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2023
Resolution: O/O provided photo of updated equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 March 2023 Resolved
EACH CHILD SIZE LIFE JACKET MUST BE STOWED IN A LOCATION THAT IS APPROPRIATELY MARKED AND SEPARATED FROM ADULT LIFE JACKETS SO THE CHILD SIZE LIFE JACKETS ARE NOT MISTAKEN FOR ADULT LIFE JACKETS. OBSERVED STOWAGE LOCATION ON UPPER DECK FOR CHILD LIFE JACKETS NOT LABELED WITH TOTAL QUANTITY OF EACH LOCATION. LABEL EACH STOWAGE LOCATION WITH TOTAL NUMBER OF CHILD LIFE JACKETS STORED.46 CFR 180.25-5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2023
Resolution: O/O provided photo of updated lable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 March 2023 Resolved
PLACARDS CONTAINING INSTRUCTIONS FOR THE DONNING AND USE OF THE LIFE JACKETS ABOARD THE VESSEL MUST BE POSTED IN CONSPICUOUS PLACES THAT ARE REGULARLY ACCESSIBLE AND VISIBLE TO THE CREW AND PASSENGERS. OBSERVED MISSING PLACARDS FOR CHILD & ADULT ON UPPER DECK WHERE LIFE JACKETS ARE STOWED. POST PLACARDS FOR INSTRUCTIONS FOR THE DONNING AND USE OF THE CHILD & ADULT LIFE JACKETS ON UPPER DECK. 46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2023
Resolution: O/O provided photo of installed placard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 March 2023 Resolved
ALL MACHINERY AND EQUIPMENT MUST BE INSTALLED AND MAINTAINED IN SUCH A MANNER AS TO AFFORED ADEQUATE PROTECTION FROM CAUSING FIRE, EXPLOSION, MACHINERY FAILURE, AND PERSONNEL INJURY. OBSERVED NO PROTECTION FROM ROTATING BELT ON STARBOARD MAIN ENGINE. INSTALL PROTECTIVE GUARD, COVER or RAIL AROUND ROTATING BELT OF STARBOARD ENGINE.46 CFR 177.35-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 May 2023
Resolution: O/O provided photo of installed guard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2023 Resolved
ELECTRICAL EQUIPMENT ON A VESSEL MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS, CREW, OTHER PERSONS, AND VESSEL FROM ELECTRICAL HAZARDS, INCLUDING FIRE, CAUSED BY, OR ORGINATING IN ELECTRICAL EQUIPMENT OR ELECTRICAL SHOCK. OBSERVED MISSING BREAKER IN THE BREAKER PANEL LOCATED IN THE PILOT HOUSE, PORT SIDE. INSTALL BLANK OR ADD BREAKER IN MISSING BREAKER IN PILOT HOUSE BREKAER PANEL. 46 CFR 183.200(b) OBSERVED MISSING BLANK ON THE DISTRIBUTION PANEL LOCATED IN THE PILOT HOUSE, PORT SIDE. INSTALL BLANK IN THE DISTRIBUTION PANEL. 46 CFR 183.10-10(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2023
Resolution: O/O provided photo of installed blank.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 April 2022 Resolved
The power fire pump may be driven off a propulsion engine or other source of power and shall be connected to the fire main. The fire pump belt driven off the port engine broke. Replace drive belt for fire pump in accordance with pump manufacture to the satisfaction of the attending marine inspector. 46 CFR 181.10-1(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 28 April 2022
Resolution: Received photo from operator of new belt installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 May 2021 Resolved
Vessel had no permanent draft or loading marks. Notified O/O that the requirement is to place a loading mark amidships in accordance with stability letter and 46 CFR 185.602 (d). This is a horizontal line at least 1 inch by 8 inches with the upper edge of the line passing through the point of max draft (minimum freeboard as measured per vessel's stability letter). Owner placed temporary marks wtih paint. Marks to be contrasting color and permanent prior to credit drydock Sept 2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 March 2023
Resolution: Observed loading mark applied amidships.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 May 2021 Resolved
Lights in hold space and steering compartment did not have guards. Issue resolved during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 May 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 May 2021 Resolved
Wheelhouse receptacle requires cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 4 May 2021
Resolution: Cover was installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 May 2021 Resolved
Port main engine oil pressure gauge at operating station was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 24 May 2021
Resolution: Gauge replaced.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 4 May 2021 Resolved
Upper deck was not marked "Crew Only". O/O had stenciling replaced during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 May 2021
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 March 2020 Resolved
Each fire station is required to have a fire hose spanner wrench. Provide spanner wrench for each station 46 CFR 181.310 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2020
Resolved 17 March 2020
Resolution: Observed presence of spanner wrenches.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2020 Resolved
Identified electrical outlet in forward accommodation space shows open ground when tested with circuit detector. Prove proper operation of grounding pole. 46 CFR 183.10-20 (o)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2020
Resolved 17 March 2020
Resolution: Receptacle was observed to have properly connected grounding pole.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 March 2020 Resolved
Each VHF radiotelephone requires a separate electrical circuit, each with over current protection. Both radios were found to be installed on the same circuit. Provide separate circuit and over current protection for each radio. 46 CFR 183.05-25 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2020
Resolved 17 March 2020
Resolution: Second VHF radiotelephone was made to be powered by an installed spare circuit breaker.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 26 March 2019 Resolved
Patch the port side buoyant apparatus. Multiple cracks/holes found in outer layer. Must meet 46 CFR 160.027 Q-spec to satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 10 May 2019
Resolution: Crewmembers made satisfactory repairs to their life float.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2019 Resolved
Life jacket lights shall be provided for every life jacket with approval series 161.012 or 160.112.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 10 June 2019
Resolution: Vessel received lifejacket lights for their remaining lifejackets.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
Vsl is broadcasting: Invalid Call Sign and greater/smaller than expected vessel length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 November 2018
Resolution: AIS information updated.
Engineering › Bilge Water Management System › Pump
Issued 5 March 2018 Resolved
(AM01): Bilge pump in lazaret does not have a positive shutoff valve at discharge. Install valve at the discharge.
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 21 May 2018
Resolution: O/O installed valve at bilge discharge.
Lifesaving › Lifefloat › Float-free Link
Issued 27 March 2017 Resolved
Secure painter to deck via weak link on port and aft lifefloats: 46CFR180.137(b)(3)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 27 March 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 March 2017 Resolved
Demonstrate operation of bilge high level alarm from lazarette at operating station in the presence of a CG Marine Inspector: 46CFR182.530(a).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 6 April 2017
Navigation › Piloting/Steering › Marine Charts
Issued 27 March 2017 Resolved
Provide updated charts for area of operation. 46CFR184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 10 April 2017
Resolution: sent email proof
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 March 2017 Resolved
Update FCC Safety Radio Telephony and Bridge to Bridge with correct call sign: 46CFR184.502
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 6 April 2017
Resolution: Sent email to [name withheld]
Construction/Loadline › Penetrations › Gasket
Issued 27 March 2017 Resolved
Provide protection for bulkhead penetration in forward engine room bulkhead: 46CFR183.220(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 6 April 2017
Resolution: Sent email to [name withheld]
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 March 2016 Resolved
Vessel is restricted to 105 total person; found 69 good adult lifejackets with lights, 36 good adult lifejackets without lights (105 total good); found 7 good children’s lifejackets with lights and 3 without light (10 total). Vessel requires 27 adult lifejackets and 4 children life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 May 2016
Resolution: Recieved evidence of servicable jackets placed on the vessel.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 March 2016 Resolved
: Remove lifejacket labeling on 1st deck port closet (no jackets are stowed there). Correct the kids and adult lifejacket labeling on the second deck storage for number count. Ensure labeling indicates which adult jackets have lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 2 April 2016
Resolution: Recieved picture of door with removed label.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 March 2016 Resolved
Update emergency instructions to reflect vessels procedures.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 13 May 2016
Resolution: Received new emergency instructions.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 February 2016 Resolved
Repair and replace port shaft and propeller to the satisfaction of Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2016
Resolved 11 February 2016
Resolution: Completed successful HULL/ISE
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 22 February 2012 Resolved
Several lights on life jackets for oceans route found expired. Correct prior to carriage of passengers past 20 NM.
Action required: 705 - Other - as specified
Resolved 16 October 2012
Resolution: Lights were replaced.
Lifesaving › Lifefloat › Serviceable
Issued 22 February 2012 Resolved
Life floats need to have repairs made IAW manufacturer specifications. Rubberized coating of [name withheld] life floats found to be cracked in several locations.
Action required: 705 - Other - as specified
Due 19 April 2012
Resolved 14 June 2013
Resolution: Vessel replaced all three (3) Life Floats with new.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 February 2012 Resolved
Corroded port engine exhaust piping system needs repair. Small pinhole found in foward plate of exhaust back pressure extension for water backflow. Clean and weld hole.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 16 October 2012
Resolution: Exhaust pipe was replaced.
Documentation › Logs/Records › Drug Test Records
Issued 26 May 2009 Resolved
Prove enrollment of all crewmembers in a safety sensitive position are enrolled in an approved drug and alcohol testing consortium or provide evidence of 2009 testing of the same members.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2009
Resolution: Operator located and faxed required paperwork to Sector Del Bay.
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 February 2009 Resolved
Prove proper operation of the lazarette high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2009
Resolution: Corrected during the inspection, float switch wiring in the lazz was found to have a corroded butt connector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 February 2009 Resolved
Replace expired items in the vessels first aid kit.
Action required: 705 - Other - as specified
Due 9 June 2009
Resolved 27 May 2009
Resolution: Eye wash and asprin replaced with new.
Communications › Radio Communications › EPIRB
Issued 24 February 2009 Resolved
Provide for inspection a properly registere EPRIB with current battery and hydrostatic release unit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2009
Resolution: Received fax verification of the purchase of a new EPRIB, HRU, and proof of registration.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 15 May 2008 Resolved
Replace three expired post incident alcohol test kits.
Due 15 June 2008
Resolved 29 May 2008
Resolution: Observed three valid post incident alcohol test kits.
Stability › Weathertight Integrity › General
Issued 15 May 2008 Resolved
Replace cracked bridge window.
Due 15 June 2008
Resolved 29 May 2008
Resolution: Bridge window replaced with appropriate safety glass.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 30 May 2007 Resolved
Condemned one Child's sized PFD. Child passenger count reduced to 14 pending owner purchasing one replacement Child's sized PFD, bringing total to 15, as required.
Action required: 705 - Other - as specified
Resolved 30 May 2007
Resolution: Owner purchased one Child sized PFD, bringing total to 15, as required.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 16 May 2006 Resolved
Hydraulic hose ran through collision bulkhead. Owner to provide plate with seamless pipe fitted to bulkhead with proper compression fittings.
Condition: Improper Installation
Due 16 June 2006
Resolved 16 June 2006
Resolution: Proper bulkhead penetrations installed.
Documentation › Certificates/Documents › FCC SSL
Issued 16 May 2006 Resolved
FCC safety certificate, still reflects old vessel name. Owner to provide new certificate.
Condition: Unknown
Due 16 June 2006
Resolved 16 June 2006
Resolution: New certificate arrived.
Communications › Radio Communications › EPIRB
Issued 16 May 2006 Resolved
NOAA registration reflected old vessel name. Owner updated data base, waiting for new registration sticker to arrive.
Condition: Unknown
Due 16 June 2006
Resolved 16 June 2006
Resolution: New certificate arrived.
Navigation
Issued 22 July 1994 Resolved
PROVIDE A CURRENT MAGNETIC COMPASS DEVIATION TABLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Electrical
Issued 22 July 1994 Resolved
REMOVE OR REPAIR THE STARBOARD AFT DECK LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Construction/Loadline
Issued 3 January 1994 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, COMPLETE A CREDIT DRYDOCK EXAMINATION TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 January 1994
Resolved 3 January 1994
Lifesaving
Issued 22 July 1993 Resolved
VESSEL RESTRICTED TO COASTWISE NOT MORE THAN 20 MILES OFFSHORE ROUTE UNTIL PROVIDED WITH AN APPROVED EPIRB AS PER 49 CFR 80.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Lifesaving
Issued 22 July 1993 Resolved
PRIOR TO CARRYING PASSENGERS RENEW GRAB LINE ON # 1 AND # 2 LIFEFLOATS.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Fire Fighting
Issued 22 July 1993 Resolved
PRIOR TO CARRYING PASSENGERS HYDRO AND SERVICE THREE (3) BII CO2 BOTTLES FIRE EXTINGUESHERS.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Engineering
Issued 24 July 1992 Resolved
REPAIR OR REPLACE THE HYDRAULIC PUMP ON THE PORT MAIN DIESEL ENGINE. PUMP SEALS HAVE A SMALL BUT STEADY WEEPING LEAK. THE SEALS HAD BEEN REPLACED THEPREVIOUS YEAR (CG-835 REQ) BUT IT STILL LEAKS.
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Lifesaving
Issued 24 July 1992 Resolved
PROVIDE WATER LIGHTS FOR ALL PERSONAL FLOATATION DEVICES. 121 JACKETS WERE MISSING LIGHTS (ALL WERE ON ORDER).
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Fire Fighting
Issued 26 July 1991 Resolved
Renew CO2 fire extinguisher bracket in engine room.
Condition: Unknown
Due 26 July 1991
Resolved 26 July 1991
Engineering
Issued 26 July 1991 Resolved
Repair oil leak on hydralic pump on port engine.
Condition: Unknown
Due 26 July 1991
Resolved 26 July 1991
Construction/Loadline
Issued 26 July 1991 Resolved
Demonstrate fixed bilge system operation.
Condition: Unknown
Due 26 July 1991
Resolved 26 July 1991
Lifesaving
Issued 26 July 1991 Resolved
Conduct fire and man overboard drill in presence of CG inspector.
Condition: Unknown
Due 26 July 1991
Resolved 26 July 1991
Documentation
Issued 26 July 1991 Resolved
Post stability letter in accordance with 46CFR.
Condition: Unknown
Due 26 July 1991
Resolved 26 July 1991
Fire Fighting
Issued 26 July 1991 Resolved
Make hand pump capable for operating from deck.
Condition: Unknown
Due 26 July 1991
Resolved 26 July 1991
Electrical
Issued 26 July 1991 Resolved
Remove/repair loose wireing for engine hot start.
Condition: Unknown
Due 26 July 1991
Resolved 26 July 1991
Lifesaving
Issued 27 July 1990 Resolved
VESSEL WAS NOT SUITABLE AS A RESCUE PLATFORM IN ACCORDANCE WITH 46CFR 180. 10-35.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Unknown
Issued 28 July 1989 Resolved
RENEW WIRING FROM FLUSING PUMP TO CONTROL SWITCHES USING AN APPROVED TYPE. ORIGINAL COMPLIANCE DATE IS 18AUG89.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Unknown
Issued 28 July 1989 Resolved
POST THE EMERGENCY CHECK OFF LIST IN THE PASSENGER CABIN. ORIGINAL COMPLIANCE DATE IS 18AUG89.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Unknown
Issued 28 July 1989 Resolved
PROVIDE 104 ADDITIONAL WATER LIGHTS ON ADULT PFDS PRIOR TO OPERATING ON OCEAN ROUTE. ORIGINAL COMPLIANCE DATE IS 18AUG89.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Engineering
Issued 13 March 1989 Resolved
MARK OR STENCIL AN ARROW INDICATING THE CLOSING DIRECTION OF THE EMERGENCY FUEL SHUT OFF VALVES WHERE MISSING.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Engineering
Issued 13 March 1989 Resolved
PROVIDE AN OPERATIONAL TEST OF ALL MAIN BILGE MANIFOLD VALVES.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Electrical
Issued 13 March 1989 Resolved
PROVIDE A COVER FOR EXPOSED ELECTRICAL WIRING FOR HEATER, PANEL BOX WHERE MISSING PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Accommodation/Occupational Safety
Issued 13 March 1989 Resolved
REPLACE FLEXIBLE VENT HOSE FROM MSD HOLDING TANK WHERE HOLED.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Electrical
Issued 24 September 1987 Resolved
PROVIDE A JUNCTION BOX AND MAKE PERMANENT CONNECTIONS IN THE WIRING FOR THELAZARETTE ELECTRIC BILGE PUMP.
Condition: Unknown
Due 24 September 1987
Resolved 24 September 1987
Navigation
Issued 29 July 1987 Resolved
MOVE THE SIDELIGHTS AFT TO COMPLY WITH THE 1980 COLREGS, ANNEX I, RULE 20(C).
Condition: Unknown
Due 29 July 1987
Resolved 29 July 1987
Engineering
Issued 29 July 1986 Resolved
INSULATE THE HOT SECTION OF EXHAUST PIPE BETWEEN THE POINT OF COOLING WATERINJECTION TO THE EXHAUST MANIFOLD ON BOTH MAIN ENGINES.
Condition: Unknown
Due 29 July 1986
Resolved 29 July 1986
Engineering
Issued 20 November 1984 Resolved
REPLACE DETERIORATED FUEL TANK VENT FLAME SCREENS. 46 CFR 182.20-35(D) IS APPLICABLE.
Condition: Unknown
Due 20 November 1984
Resolved 20 November 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.