AMERICAN PATRIOT is a 1978 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 1985, most recently in December 2025, along with 206 deficiencies.

Records from 1985 to 2025. Most recent: inspection, 17 December 2025.

Built
1978
Last inspected
17 December 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL3405
Flag
UNITED STATES
366888000
Maury page id
psix-49615

Inspections, by type

…with no type recorded6
Years with a record 39 calendar years (1985–2025)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)120.0 ft × 27.0 ft × 8.0 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPUTNAM SHIPBUILDING CORP · PALATKA, FL, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOLLYWOOD, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL3405MMSI 366888000 · active · compulsorily equipped · granted 20 November 2019, expires 20 November 2029
WDI7331MMSI 367727660 · expired · compulsorily equipped · granted 14 April 2016, cancelled 20 June 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDC9371MMSI 367101380 · expired · compulsorily equipped · granted 23 March 2006, cancelled 28 May 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDC6193MMSI 303453000 · expired · compulsorily equipped · granted 28 June 2005, cancelled 29 August 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCW3959MMSI not assigned · expired · compulsorily equipped · granted 4 April 1996, cancelled 10 June 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 84

17 December 2025 Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8292392
8 October 2025 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8238940
29 January 2025 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8071386
21 February 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7865341
4 January 2024 Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7846865
4 December 2023 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7840552
11 May 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7686200
25 January 2023 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7626393
12 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7575757
31 January 2022 In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7388074
22 January 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7384054
6 January 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7376294
23 August 2021 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7291404
8 May 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7192285
3 March 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7149537
13 November 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7099900
18 March 2019 Inclining Experiment · Examination of Repairs · COI Inspection · Administrative Inspection · Spot Check · Construction Oversight · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6650875
17 October 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6559364
30 April 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6404958
26 October 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6295671
17 April 2017 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6125990
15 November 2016 Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6040872
23 March 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5859606
2 May 2014 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4877202
25 July 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4390244
5 December 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4201806
29 October 2010 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3880778
9 February 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3414761
5 December 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3374710
4 November 2008 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3356529
5 May 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3200283
4 April 2008 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3179235
17 July 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2998305
30 April 2007 MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2920695
9 May 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2645068
2 June 2005 Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2377107
3 November 2004 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2246325
4 May 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2058692
8 May 2003 Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1788938
12 November 2002 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1719991
4 April 2002 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1601286
10 April 2001 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1447075
26 April 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1412084
4 February 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1376061
18 January 2000 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1427768
23 September 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342641
3 May 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1462746
16 November 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1433411
25 March 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122273
18 March 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 775887
25 April 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1106864
4 December 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857169
3 May 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1080224
19 April 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1081874
10 March 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868300
1 November 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171476
2 March 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854255
26 March 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147537
11 November 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827317
14 October 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1269120
19 June 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 956238
27 April 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946297
21 May 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228591
19 March 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309129
19 November 1990 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906229
1 October 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 925873
11 September 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1221414
8 August 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230419
1 June 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226080
6 June 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1345511
9 May 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033001
1 March 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900615
7 June 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 887546
16 March 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030484
19 November 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333790
28 October 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020194
30 July 1987 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337566
11 June 1987 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026475
31 July 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294955
27 June 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1306372
26 June 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 999054
4 December 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294603
31 October 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299402
18 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1291822

Deficiency record · 206

03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 January 2025 Resolved
A hatch cover must:be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Hatches were not secured to prevent loss. 46 CFR 179.360(b)(2)
Action required: 10 - Deficiency Rectified
Resolved 29 January 2025
Resolution: Hatches were tied to the ladder just under them.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 January 2025 Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Existing vessels as of July 22, 2016 have 180 days to comply with this requirement. No spanner wrench is proved at 1.5 in firehose. 46 CFR 181.310(d)
Action required: 10 - Deficiency Rectified
Resolved 29 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 January 2025 Resolved
Each survival craft must be: Secured to the vessel by a painter line with a float-free link permanently attached to the vessel. Liferafts painter line was not properly attached to the weak link. 46 CFR 180.130(a)(1)
Action required: 10 - Deficiency Rectified
Resolved 29 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 January 2025 Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free. A line is tied over 02 life rafts preventing it from floating free if the vessel sinks. 46 CFR 180.130(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 29 January 2025
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 April 2018 Resolved
First aid kit has expired items. First aid kit no longer meets the requirements set forth by 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Purchased 3 new first aid kits to replace expired items.
Electrical › Electrical Distribution System (service) › Cable
Issued 30 April 2018 Resolved
Dead end cables was discovered under bridge console. Electrical installation is required to be installed and maintained to protect crew, passenger, and other persons from electric hazards such as electric shock.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 30 April 2018 Resolved
Receptacle outlet cover missing. Electrical installation is required to be installed and maintained to protect crew, passenger, and other persons from electric hazards such as electric shock.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Replaced receptacle outlet cover to protect crew and passengers from potential electric hazards.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 30 April 2018 Resolved
Portable fire extinguisher was not properly mounted or fasten. Portable fire extinguishers are required to be stowed IAW NFPA 10 to prevent dislodgement
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: A new bracket was installed to properly secure portable fire extinguisher.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 April 2018 Resolved
Portable fire extinguisher was not serviced IAW NFPA intervals
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Provided proof of fire extinguisher servicing with current servicing tag.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 April 2018 Resolved
Electrical light fixture was discovered broken. Electrical installation is required to be installed and maintained to protect crew, passenger, and other persons from electric hazards such as electric shock.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Broken electrical light fixtures were replaced and properly installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 April 2018 Resolved
Lighting fixture missing protective guard. Protective guards are required where possible damage to the light may occur
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Missing light fixture covers were replaced.
Stability › Watertight Integrity › General
Issued 30 April 2018 Resolved
Penetration through watertight bulkhead must maintain its water tight integrity. New piping for fresh water was replaced and the integrity of watertightness is compromised.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Compromised watertight integrity in way of forward bulkhead was repaired to maintain watertight integrity.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 April 2018 Resolved
Receptacle in lazarette discovered without cover. Electrical installation is required to be installed and maintained to protect crew, passenger, and other persons from electric hazards such as electric shock.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2018
Resolution: Placed cover over receptacle located in lazarette.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 30 April 2018 Resolved
Plastic waste receptacles was discovered throughout the vessel. Waste receptacles are required to be constructed of non combustible material unless other means are provided to ensure that a potential waste receptacle fire would be limited to the waste receptacle
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: All plastic waste receptacles were replaced with non combustible material waste receptacles for fire prevention.
Engineering › Fuel Oil Service System › Piping
Issued 30 April 2018 Resolved
Fuel fill pipe was discovered inside the vessel. Fill pipes must be so arranged so that overflow of liquid or vapors cannot escape to the inside the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2018
Resolved 11 July 2018
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 30 April 2018 Resolved
Receptacle outlets installed in wet bar is required to be drip proof
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Installed drip proof cover over receptacle outlets in way of wet bar.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 30 April 2018 Resolved
Electrical cables penetrations through water tight bulkhead is required to maintain the integrity of watertightness.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Electrical cable penetrations through watertight bulkhead were fixed with proper sealant to maintain watertight integrity.
Accommodation/Occupational Safety › Potable Water System › General
Issued 30 April 2018 Resolved
Ice maker was deemed unsanitary
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Witnessed sanitized ice maker in way of galley.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 30 April 2018 Resolved
Exhaust gas leaking from engine. All unsafe condition must be corrected
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Exhaust gas leak from engine was corrected ensuring proper ventilation and exhaust system maintenance.
Engineering › Pressure Vessel › Marking and Stamping
Issued 30 April 2018 Resolved
Pressure vessel on board was discovered not meeting the requirements of ASME. Did not have the "U" or "UM marking.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: U type pressure vessel installed.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 30 April 2018 Resolved
Vessel distribution system is not of the ungrounded type that is prescribed for the installation based on keel laid date IAW 46 CFR 183.10-30(old "T") OCMI may require vessel to comply with Sub ch "J" for dual voltage systems
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2018
Resolved 11 July 2018
Resolution: Vessel meets requirements with SubChapter "J" dual voltage systems.
Electrical › Electric Supply System (service) › Battery Charger
Issued 30 April 2018 Resolved
Battery charger did not have an ammeter. Battery chargers are required to have an ammeter
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Installed ammeter for battery charger.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 April 2018 Resolved
Electrical connection throughout the vessel was discovered installed outside junction boxES. All electrical connections shall be made in an enclosure
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Identified electrical connections installed outside the junction box were rerouted and properly connected within a junction box.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 30 April 2018 Resolved
Upon reviewing log book vessel didn't log when drills were conducted. Drills are required to be logged
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2018
Resolved 11 July 2018
Resolution: Vessel conducted drills and made proper entry in the log book.
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 April 2017 Resolved
Vessel needs to provide log book containing proof of all drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: Vessel provided logbook with drills recorded.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 17 April 2017 Resolved
Vessel needs to provide method/instructions for passenger orientation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: Operators provided written passenger orientation for vessel.
Operations/Management › Vessel Activity › Other
Issued 17 April 2017 Resolved
Vessel needs to provide method for recording/reporting the passenger count for each trip.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 28 April 2017
Resolution: Operator provided passenger count method.
Electrical › Electric Generation Source (service) › Panelboard
Issued 17 April 2017 Resolved
Vessel needs to properly label all electrical panels and breakers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: Electrical panels and breakers were labeled.
Engineering › Steam Boiler (auxiliary/waste heat) › Water Level Indicator
Issued 17 April 2017 Resolved
Vessel needs to fix inoperable visual indicator for the low water cutoff on the boiler.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: Operator replaced boiler low cutoff alarm, had tech report and demonstrated low cutoff alarm.
Deck/Cargo › Cargo Stowage › General
Issued 17 April 2017 Resolved
Vessel needs to secure all equipment in the galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: Operator rearranged equipment in galley to ensure safer placement.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 17 April 2017 Resolved
Properly mount all fire extinguishers with approved brackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: Operator replaced portable extinguishers with new extinguishers and mounts.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 17 April 2017 Resolved
Vessel had a deep fat fryer and griddle in the galley space and no fixed extinguishing system was proved for the hood.
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 17 April 2017
Resolution: Vessel elected to remove all cooking equipment from the galley. No fixed system is needed anymore.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 17 April 2017 Resolved
Vessel needs to repair junction box on the stbd side, mid body, on outside main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: Junction box was installed.
Electrical › Electric Supply System (service) › Cable
Issued 17 April 2017 Resolved
Vessel is to remove all extension cables from vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: All extenstion cords were removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 April 2017 Resolved
Vessel needs to provide protective guards on all rotating parts on the main engines and generators.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: operator install guards on all engines and generators.
Documentation › Markings/Placards › Warning Signs
Issued 17 April 2017 Resolved
Vessel needs to properly mark all the emergency exits for the galley and engine room.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: All emergency exits and hatches were labeled.
Fire Fighting › Fire Pumps › Pressure
Issued 17 April 2017 Resolved
Vessel's fixed fire pump cannot produce the required 60 psi.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2017
Resolved 28 April 2017
Resolution: Operator installed new guage and test fire hose to 60psi.
Documentation › Certificates/Documents › FCC SSL
Issued 23 March 2016 Resolved
Provide FCC SSL.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 13 April 2016
Resolution: Vessel found FCC SSL.
Engineering › Steering Gear System › Hydraulic Hose
Issued 23 March 2016 Resolved
Repair Hydraulic Leak for the steering system in the E/R starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 13 April 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 March 2016 Resolved
Renew all expired items in First Aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 13 April 2016
Resolution: Vessel replace first aid kit.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 23 March 2016 Resolved
Provide up to date charts for vessels route. Charts must be large enough scale to make safe
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 13 April 2016
Resolution: Vessel provided proper charts.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 23 March 2016 Resolved
Vessel must provde current Coast Pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 13 April 2016
Resolution: Vessel provided current Coast Pilot.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 23 March 2016 Resolved
Vessel needs to provide Light List.
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 13 April 2016
Resolution: Vessel provide light list.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 23 March 2016 Resolved
Prove proper operation of generator Voltmeter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 13 April 2016
Resolution: Voltmeter found satisfactory.
Accommodation/Occupational Safety › Heating › Piping
Issued 23 March 2016 Resolved
Remove heat insulation on all heating system pipes in the engine room that is melted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 13 April 2016
Resolution: Vessle replaced/removed melted insulation.
Electrical › Electric Generation Source (service) › Generator
Issued 23 March 2016 Resolved
Provide exhaust insulationon both generators, all the way to the turbos.
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 13 April 2016
Resolution: Vessel provided insulation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 March 2016 Resolved
Remove old COI thats posted on the main deck. Replace with current COI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 13 April 2016
Resolution: COI was replaced and posted.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 March 2016 Resolved
Repair R/W leak on port main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 13 April 2016
Resolution: R/W leak repaired.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 23 March 2016 Resolved
Repair water leak on the port generator exhaust in the lazarette at the muffler.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 13 April 2016
Resolution: Leak was repaired.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 March 2016 Resolved
100 Kapok Life jackets failed inspection. Replace Life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 13 April 2016
Resolution: Vessel replaced 100 lifejackets.
Lifesaving › Lifebuoys › Stowage
Issued 2 May 2014 Resolved
Lifebuoy needs light permanently installed onto lifering and mounted.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 June 2014
Resolution: Lifering permanently installed and properly mounted.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 2 May 2014 Resolved
Portable fire extinguisher in gallery needs to be secured.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 June 2014
Resolution: extinguisher was securely mounted.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 2 May 2014 Resolved
Galley circuit breakers need to have blanks installed to cover openings.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 June 2014
Resolution: Blanks installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 May 2014 Resolved
Outlets around sink in galley need to be permanently installed.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 June 2014
Resolution: Outlets permanently installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 May 2014 Resolved
STBD side battery box in E/R needs to be glassed in.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 June 2014
Resolution: Witnessed glassed in battery box.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2014 Resolved
Unattached wire below center engine block needs to be reattached or dead ended properly.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 June 2014
Resolution: Wire was found to have come off of a sensor and reattached with added security.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 2 May 2014 Resolved
Port side exhaust pipe was found to have 1/4" hole in the weld of the bend in line and needs to be re-welded.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 9 June 2014
Resolution: Witnessed vessel''s having exhaust pipe properly repaired.
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2011 Resolved
Owner/Operator failed to submit stability certification compliance by 01DEC11. Issued CG-835 requesting compliance with assumed average weight per person of 185 pounds and in accordance with 46 CFR 178.320 amended by FR vol. 75, No. 239, USCG-2007-0030. OCMI did not recude passenger count as COI restriction limits the number to 150 passengers.
Action required: 705 - Other - as specified
Resolved 27 April 2012
Resolution: All sat.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 29 October 2010 Resolved
Provide draft marks.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 10 May 2011
Resolution: Draft marks in place.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 October 2010 Resolved
Install (weld) stiffener (angle) IWO fwd engine room bulkhead fuel tank repair.
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 26 May 2011
Resolution: Stiffener welded in place.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 29 October 2010 Resolved
Due to new propellers prove compliance w/ 46 CFR 182.200(a).
Action required: 705 - Other - as specified
Due 16 December 2010
Resolved 20 May 2011
Resolution: Conducted underway test. New props did not produce any vibration.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 29 October 2010 Resolved
Provide an attachment for the forpeak hatch cover.
Action required: 705 - Other - as specified
Due 22 December 2010
Resolved 10 May 2011
Resolution: Hatch cover now has attachment.
Construction/Loadline › Penetrations › Pipe Flange
Issued 4 November 2008 Resolved
Remove PVC pipe from port side forward bulkhead of Lazarette and make watertight with a metal fitting.
Action required: 705 - Other - as specified
Due 4 December 2008
Resolved 5 December 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 4 November 2008 Resolved
Remove PVC pipe port side aft of Lazarette that passes up into the overhead and make watertight.
Action required: 705 - Other - as specified
Due 4 February 2009
Resolved 9 February 2009
Construction/Loadline › Structures › Deck Plating
Issued 4 November 2008 Resolved
Crop and renew overhead plating that is currently a 6" x 18" doubler in way of Lazarette port side forward bulkhead with an 18" x 18" insert with 3" radius corners.
Action required: 705 - Other - as specified
Due 4 February 2009
Resolved 4 November 2008
Resolution: Using NVIC 7-68 as guidance regarding this doubler, Marine Inspector(s) concluded that it is acceptable in regards to its location and no further repairs are required.
Stability › Unintentional Flooding › General
Issued 4 November 2008 Resolved
Renew packing material on starboard rudder post making it watertight prior to vessel splashing.
Action required: 705 - Other - as specified
Due 4 December 2008
Resolved 7 November 2008
Construction/Loadline › Structures › Door
Issued 4 November 2008 Resolved
Make both main deck sliding doors operable to be opened freely. They currently require extraordinary effort when attempting to slide open from the inside of vessel.
Action required: 705 - Other - as specified
Due 4 December 2008
Resolved 5 December 2008
Engineering › Lubricating Oil Service System › Hose
Issued 4 November 2008 Resolved
Repair lube oil leaks on starboard main engine outboard side of turbo.
Action required: 705 - Other - as specified
Due 4 December 2008
Resolved 5 December 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 4 November 2008 Resolved
Clean engineroom bilges of all oil and debris.
Action required: 705 - Other - as specified
Due 4 December 2008
Resolved 5 December 2008
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 4 November 2008 Resolved
Renew aft cutlass bearing on port shaft strut prior to vessel going back into water.
Action required: 705 - Other - as specified
Due 4 December 2008
Resolved 7 November 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 April 2008 Resolved
Prior to night operations, replace anchor light CG-approved light bulb.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 5 May 2008
Resolution: Vsl replaced anchor light with approved light bulb.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 April 2008 Resolved
Install guards on air compressor and motor belt.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 5 May 2008
Resolution: Vsl made satisfactory repairs.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 April 2008 Resolved
Install guard on starboard engine belt for alternator.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 5 May 2008
Resolution: Vsl made satisfactory repairs.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 4 April 2008 Resolved
Vessel is restricted to 151 persons total. Replace out of service lifejackets to make vessel lifejacket count to be 169 adult lifejackets IAW COI.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 5 May 2008
Resolution: Vsl replaced lifejackets.
Documentation › Certificates/Documents › FCC SSL
Issued 30 March 2007 Resolved
Provide FCC Radio Safety Certificate onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Documentation › Certificates/Documents › FCC SSL
Issued 30 March 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 30 March 2007 Resolved
Provide CG Light List onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 30 March 2007 Resolved
Complete Emergency Broadcast Placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Lifesaving › Lifefloat › Lifeline
Issued 30 March 2007 Resolved
Replace lifelines in way of all lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 30 March 2007 Resolved
Replace floating electric waterlight in way of starboard lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Lifesaving › Lifefloat › Paddle
Issued 30 March 2007 Resolved
Mark lifefloat paddles with vessel's name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 30 March 2007 Resolved
Remove spool of rope lighting from starboard lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Communications › Public Address System › Loudspeaker
Issued 30 March 2007 Resolved
Prove proper operation of public address system in way of main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 March 2007 Resolved
Provide floating waterlight in way of ring buoy, 2nd deck, aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 March 2007 Resolved
Secure floating waterlight to ring life buoy with UV resistant lanyard and corrision resistant clip.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 March 2007 Resolved
Provide 60ft, UV resistant, buoyant lifeline in way of ringbuoy 2nd deck aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2007
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 30 March 2007 Resolved
Repair/Replace wasted bilge strainers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Electrical › Lighting (service) › Conductor
Issued 30 March 2007 Resolved
Remove extension cords and power strips from Engine room overhead.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 30 March 2007 Resolved
Prove proper operation of the installed bilge system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Engineering › Fuel Oil Service System › Hose
Issued 30 March 2007 Resolved
Double clamp hoses on all vital machinery systems.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 March 2007 Resolved
Install bilge alarm in lazarette due to double clamped non-metallic muffler installed in wet exhaust system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2007
Resolved 17 July 2007
Fire Fighting › Fire Hoses › Condition
Issued 30 March 2007 Resolved
Replace worn STBD Fire hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Fire Fighting › Fire Main › Condition
Issued 30 March 2007 Resolved
Replace holed piping in Fire main discharge in the Engine room overhead.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 30 March 2007 Resolved
Complete emergency drills in the presence of the USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 30 March 2007 Resolved
Clear debris/garbage/ and miscellaneous equipment from all bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 30 March 2007 Resolved
Determine source of water leak from port main engine and make permanent repairs.
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 17 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 30 March 2007 Resolved
Secure wet exhaust leak at pipe manifold, port side, engine room.
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 17 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 30 March 2007 Resolved
Determine source of oil leak on port main engine.
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 17 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 30 March 2007 Resolved
Secure oil leak on starboard main engine.
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 17 July 2007
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 30 March 2007 Resolved
Install railing for engine room ladder, starboard side.
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 17 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 30 March 2007 Resolved
Install lagging on starboard main engine turbo charger.
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 17 July 2007
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 30 March 2007 Resolved
Demonstrate safer means of launching and recovering rescue platform.
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 17 July 2007
Documentation › Certificates/Documents › FCC SSL
Issued 9 May 2006 Resolved
Obtain new Safety Radio Certificate. Vessel restricted to no more than 1000 feet from shore.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 25 May 2006
Resolution: Vessel obtained new certificate.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 9 May 2006 Resolved
Replace turbo charger oil drain hose on center engine.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 25 May 2006
Resolution: Drain hose replaced.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 May 2006 Resolved
Remove excessive oil in engine room bilge.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 25 May 2006
Resolution: Oil removed and bilges wiped down.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 May 2006 Resolved
Replace bulb for emergency lighting fixture in passenger cabin, port side.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 25 May 2006
Resolution: New bulb installed.
Construction/Loadline › Structures › Superstructure
Issued 10 June 2005 Resolved
Replace broken window on bridge IWO centerline.
Due 10 July 2005
Resolved 17 June 2005
Resolution: Replaced Same.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 10 June 2005 Resolved
Lable emergency escapes.
Due 10 July 2005
Resolved 17 June 2005
Resolution: Labeled same.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 2 June 2005 Resolved
Vessel O/O was unable to provide proof of an Employer policy for Drug & Alcohol program.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Vessel O/O provided Employer policy for Drug & Alcohol program.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 2 June 2005 Resolved
Vessel O/O was unable to provide proof that supervisors had received the required 60 minutes annual Drug & Alcohol training.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Provided Same.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 June 2005 Resolved
All pages of the COI were not posted, visible to passengers.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Posted same.
Documentation › Logs/Records › Logbook (official)
Issued 2 June 2005 Resolved
Vessel O/O unable to provide documentation that required drills were conducted.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Vessel O/O began documenting required drills.
Navigation › Piloting/Steering › Marine Charts
Issued 2 June 2005 Resolved
Vessel O/O was unable to provide updated charts or Local Notice to Mariners.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Vessel O/O provided copies of Local Notice to Mariners.
Documentation › Markings/Placards › Warning Signs
Issued 2 June 2005 Resolved
Vessel did not have an Emergency Broadcast Placard posted at the control station.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Vessel O/O posted Emergency Broadcast Placard posted at the control station.
Communications › Radio Communications › EPIRB
Issued 2 June 2005 Resolved
EPIRB registration was found to be outdated and Marine Inspector was unable to determine hydrostatic release date. Vessel restricted to less than 3nm until deficiency is cleared.
Due 17 June 2005
Resolved 17 June 2005
Resolution: Registered/Provided Same.
Communications › Internal Communications System › Portable Radios
Issued 2 June 2005 Resolved
Vessel O/O failed to prove proper operation of Public Address System.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Public Address System repaired and operational.
Fire Fighting › Means of Escape › Blocked
Issued 2 June 2005 Resolved
Vessel O/O unable to prove proper operation of emergency escapes from engine room and fwd storage area.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Emergency escapes from engine room and forward storage area properly operated.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 June 2005 Resolved
Vessel O/O failed to provide a locking device on oven doors.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Locking devices were placed on oven doors.
Lifesaving › Lifefloat › Paddle
Issued 2 June 2005 Resolved
Paddles for lifefloats were found to be broken, cracked and faded.
Due 10 June 2005
Resolved 10 June 2005
Resolution: New oars were puchased.
Lifesaving › Lifefloat › Retroreflective Material
Issued 2 June 2005 Resolved
Retroreflective Material on lifefloats were faded and needed replacing.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Retroreflective material was replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 June 2005 Resolved
Vessel O/O failed to maintain the proper size/type of line on the waterlight for all lifefloats and the lifering buoy.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Replaced Same with Proper.
Lifesaving › Lifebuoys › Serviceable
Issued 2 June 2005 Resolved
Lifering buoy on stern of vessel was found to be cracked and in need of replacement.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Replaced Same.
Fire Fighting › Fire Hoses › Length
Issued 2 June 2005 Resolved
Vessels fire hoses were found to be 50' in length. COI called for 100'.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Firehoses were found to be correct as per the CFR.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 June 2005 Resolved
Fwd fuel cut out valve was found to be inoperative.
Due 3 June 2005
Resolved 10 June 2005
Resolution: Fuel cut out valve was repaired and properly operated.
Engineering › Bilge Water Management System › Piping
Issued 2 June 2005 Resolved
Vessels bilge piping system contained non-metallic hose.
Due 17 June 2005
Resolved 17 June 2005
Resolution: Hard Piped Same.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 June 2005 Resolved
Vessels bilge high-level alarms failed to operate with both a visual and audible alarm. Vessel crew required to make 30 minutes rounds of all void spaces until deficiency is cleared by the Coast Guard.
Due 6 June 2005
Resolved 10 June 2005
Resolution: Bilge high-level alarms were repaired and properly operated.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 2 June 2005 Resolved
Numerous "strip plugs" were found throughout the vessel.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Removed Same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2005 Resolved
Improperly dead-ended wires were found throughout the vessel.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Properly Stowed Same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2005 Resolved
Improperly spliced wires were found throughout the vessel.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Properly Stowed Same.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 June 2005 Resolved
Vessel O/O failed to properly lable all electrical panels.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Properly Labeled same.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 June 2005 Resolved
Light fixture in lazerett was not properly secure.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Properly Secured Same.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 June 2005 Resolved
Lighting fixture in main deck storage closet was missing cover.
Due 10 June 2005
Resolved 10 June 2005
Resolution: New lighting fixture installed.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 2 June 2005 Resolved
Vessel O/O failed to maintain engine room bilges clear of excess oily mixtures.
Due 3 June 2005
Resolved 17 June 2005
Resolution: Removed same.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 2 June 2005 Resolved
Vessel O/O failed to secure microwave in galley.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Removed Same.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 June 2005 Resolved
Vessel O/O failed to properly secure elelctrical box to bulkhead in fwd storage area.
Due 10 June 2005
Resolved 17 June 2005
Resolution: Properly Secured Same.
Fire Fighting › Means of Escape › Blocked
Issued 2 June 2005 Resolved
Vessel O/O failed to keep emergency escapes clear.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Means of escape were made clear.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 June 2005 Resolved
Vessel O/O failed to lable the fuel cut out valves.
Due 10 June 2005
Resolved 10 June 2005
Resolution: Fuel cut out valves were labled.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 June 2005 Resolved
Vessels stbd hand rail was found to be cracked in two areas.
Due 17 June 2005
Resolved 17 June 2005
Resolution: Welded Same Proper.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 4 May 2004 Resolved
Provide current edition of Rules of the Road (E).
Due 11 May 2004
Resolved 2 June 2004
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 May 2004 Resolved
Provide current edition of U.S. Coast Pilot.
Due 11 May 2004
Resolved 2 June 2004
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 May 2004 Resolved
Provide current edition of the Coast Guard Light List.
Due 11 May 2004
Resolved 2 June 2004
Lifesaving › Lifefloat › Serviceable
Issued 4 May 2004 Resolved
Provide waterlight for 1 life float. Vessel is restricted to daylight operation until this requirement is met.
Due 4 May 2004
Resolved 4 May 2004
Lifesaving › Lifebuoys › Serviceable
Issued 4 May 2004 Resolved
Provide two ring life buouys (24" diam.).
Due 4 May 2004
Resolved 4 May 2004
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 May 2004 Resolved
Properly tighten shaft packing on port engine.
Due 11 May 2004
Resolved 4 May 2004
Documentation › Certificates/Documents
Issued 8 May 2003 Resolved
Provide current certificate of membership from NEDPC indicating that company/crew are involved in required drug and alcohol program. LEGACY COMPONENT DESC: DAPI policy/cert. of consortium membership
Action required: 705 - Other - as specified
Due 8 May 2003
Resolved 9 May 2003
Resolution: Received fax copy of certificate indicating that company and crew were covered by a required drug and alcohol program.
Navigation › Piloting/Steering
Issued 8 May 2003 Resolved
32 V magnetic compass (Binnacle) light inop. LEGACY COMPONENT DESC: Binnacle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Navigation › Piloting/Steering
Issued 8 May 2003 Resolved
Provide current copies of Coast Guard Light List Vol. 1 and Coast Pilot Vol. 2. LEGACY COMPONENT DESC: Coast Guard Light List/Coast Pilot
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Communications › Radio Communications
Issued 8 May 2003 Resolved
Replace expired EPIRB battery and HRU as needed. Vessel not permitted to operate beyond 3 NM from land until EPIRB is properly outfitted. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Communications › Visual Communication
Issued 8 May 2003 Resolved
Post placards near exits stating "EMERGENCY EXIT, KEEP CLEAR" as required. LEGACY COMPONENT DESC: Warning Sign
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Communications › Visual Communication
Issued 8 May 2003 Resolved
Post PFD donning placards as required throughout vessel IWO passenger areas. LEGACY COMPONENT DESC: Donning Placards (PFD)
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 May 2003 Resolved
Replace expired contents in first aid kit as necessary. LEGACY COMPONENT DESC: First Aid Kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 8 May 2003
Resolution: Corrected on scene.
Accommodation/Occupational Safety › Occupational Safety
Issued 4 April 2002 Resolved
Replace broken bridge window stbd fwd.
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Broken bridge window replaced, all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 April 2002 Resolved
Replace expired first-aid kit meds
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Expired eyewash and aspirin replaced, all sat this date
Documentation › Manuals/Policy Documentation
Issued 4 April 2002 Resolved
Provide current proof of enrollment in drug and alcohol prevention program and company policy manual.
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Company provided proof of enrollment via fax to USCG ACTNY P&C Division, that they are in fact enrolled in a currnet DAPI program, all sat.
Navigation
Issued 10 April 2001 Resolved
Provide for proper 46 CFR regulations on board vessel.
Condition: Unknown
Due 10 May 2001
Resolved 13 April 2001
Lifesaving
Issued 10 April 2001 Resolved
Replace outdated flares on board.
Condition: Unknown
Due 10 May 2001
Resolved 14 August 2001
Engineering
Issued 10 April 2001 Resolved
Replace flame screens for port side fuel tank vent.
Condition: Unknown
Due 10 May 2001
Resolved 14 August 2001
Lifesaving
Issued 10 April 2001 Resolved
Replace worn and frayed line to ring bouy located on stern of vessel.
Condition: Unknown
Due 10 May 2001
Resolved 14 August 2001
Lifesaving
Issued 10 April 2001 Resolved
Provide corrosion resistant clip for ring bouy light line for line attachedto bouy located on aft end of vessel.
Condition: Unknown
Due 10 May 2001
Resolved 3 August 2001
Electrical
Issued 26 April 2000 Resolved
REMOVE EXTENSION CORDS AND PROPLERY HARD WIRE ALL PERMANENTLY MOUNTED EQUIP. AND PROVIDE PROPER OUTLETS AS NEEDED.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Unknown
Issued 18 January 2000 Resolved
Vessel is prohibited from carrying more than 6 passengers for hire until the newly installed port generator is tested to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Lifesaving
Issued 3 May 1999 Resolved
Provide reciept for new EPIRB hydro-release or certification of existing release.
Condition: Unknown
Due 3 June 1999
Resolved 23 September 1999
Documentation
Issued 3 May 1999 Resolved
Provide copy of 1999 DAPI contract.
Condition: Unknown
Due 4 May 1999
Resolved 10 May 1999
Documentation
Issued 3 May 1999 Resolved
Provide copy of station bill.
Condition: Unknown
Due 3 June 1999
Resolved 10 May 1999
Engineering
Issued 3 May 1999 Resolved
Supply engine room fuel transfer filter with SAE spec flex hose and flame bowl.
Condition: Unknown
Due 3 June 1999
Resolved 23 September 1999
Lifesaving
Issued 3 May 1999 Resolved
Repair rip in aft life ring and update retro-tape to Type-II.
Condition: Unknown
Due 4 May 1999
Resolved 10 May 1999
Documentation
Issued 3 May 1999 Resolved
Provide copy of 46 CFR 166-199.
Condition: Unknown
Due 3 June 1999
Resolved 23 September 1999
Navigation
Issued 3 May 1999 Resolved
Provide day shape for vessel.
Condition: Unknown
Due 3 June 1999
Resolved 23 September 1999
Fire Fighting
Issued 3 May 1999 Resolved
Service bridge dry-chem B-II extinguisher.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Fire Fighting
Issued 18 March 1998 Resolved
Prove proper servicing of all portable fire extinguishers.
Condition: Unknown
Due 18 March 1998
Resolved 20 March 1998
Unknown
Issued 18 March 1998 Resolved
Procure a copy of 46CFR subchapter T.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Engineering
Issued 18 March 1998 Resolved
Repair gauge to port main engine.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 18 March 1998 Resolved
Prove that drills have been conducted IAW 46CFR185.524(a) and 185.520.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 18 March 1998 Resolved
Mount fire axe near the operating station.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Lifesaving
Issued 25 April 1997 Resolved
CLEAN & RE-LABLE, AS NEEDED, LIFE FLOATS.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Lifesaving
Issued 25 April 1997 Resolved
PROVIDE 406MHZ, CATAGORY 1, EPIRB.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Lifesaving
Issued 25 April 1997 Resolved
PROVIDE INSTRUCTION PLACARD FOR DONNING OF LIFEJACKETS.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Lifesaving
Issued 25 April 1997 Resolved
RE-LABLE STORAGE COMPARTMENT FOR CHILD LIFEJACKETS.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Fire Fighting
Issued 25 April 1997 Resolved
SERVICE & RECHARGE 4 FIRE EXTINGUISHERS.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Lifesaving
Issued 25 April 1997 Resolved
PROVIDE AND PROPERLY LABEL STORAGE CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Unknown
Issued 3 May 1996 Resolved
VESSEL IS TO CARRY PASSENGERS ONLY IN PROTECTED WATERS (RIVERS ROUTE, INSIDE THE VERRAZANO BRIDGE) IN ACCORDANCE WITH THE INTERIM STABILITY LETTER UNTIL THE PERMANENT LETTER IS ISSUED.
Condition: Unknown
Due 15 June 1996
Resolved 10 May 1996
Lifesaving
Issued 3 May 1996 Resolved
PROVIDE DOCUMENTATION OF DRUG AND ALCOHOL TRAINING, FOR BOTH SUPERVISOR(S) AND EMPLOYEES. MARINE EMPLOYER IS NOT AUTHORIZED TO OPERATE AFTER 03JUN96.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Documentation
Issued 19 June 1992 Resolved
PROVIDE APPROVED STABILITY CALCULATIONS TO INCLUDE CANOPY ON UPPER DECK, TOLOCAL [name withheld] ARCHITECT INFORMATION, CANOPY MAY BE INSTALLED UNTIL COMPLETION OF THIS REQUIREMENT._x001C_ _x001C_
Condition: Unknown
Due 19 June 1992
Resolved 19 June 1992
Engineering
Issued 1 June 1990 Resolved
DEMONSTRATE PROPER OPERATION OF AUX HEATING BOILER AND SAFETY DEVICES.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Electrical
Issued 1 June 1990 Resolved
PROVIDE BLANK FOR ELECTRICAL PANEL LOCATED IN GENERATOR ROOM.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990 Resolved
PROVIDE CURRENT CERT. OF DOCUMENTATION ONBOARD VESSEL.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Electrical
Issued 1 June 1990 Resolved
CHOCK BATTERIES IN THE BATTERY BOXES FOR BOTH GENERATOR STARTING SYTEMS.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990 Resolved
PROVIDE PROOF OF CURRENT FCC RADIO STATION LICENSES.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Engineering
Issued 1 June 1990 Resolved
INSTALL APPROVED FUEL HOSES AND FITTINGS ON BOTH GENERATORS, OIL PRESSURE GAUGE HOSE ON STBD MDE, AND REDUTION FEAR OIL PRESSURE GAUGE HOSE ON STBD MDE.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Construction/Loadline
Issued 9 May 1989 Resolved
PROVIDE A COAMING OF 6 INCHES IN HEIGHT FOR THE AFT EXIT FROM THE DECK HOUSE UNTIL THIS ITEM IS CORRECTED THE VESSEL IS RESTRICTED TO A LAKES, BAYS AND SOUNDS ROUTE.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Construction/Loadline
Issued 28 October 1987 Resolved
MAKE PERMANENT REPAIR TO MAIN DECK IN WAY OF HEATING BOILER EXHAUST PIPING PENETRATION.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Accommodation/Occupational Safety
Issued 28 October 1987 Resolved
REMOVE ALL FLAMMABLE STORES FROM BILGES BENEATH BERTHING AREA.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Construction/Loadline
Issued 28 October 1987 Resolved
PROVIDE CAPTIVE CHAINS FOR MAIN DECK HATCHES TO FOREPEAK AND LAZARETTE.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Deck/Cargo
Issued 28 October 1987 Resolved
PROVIDE PORTABLE BILGE PUMP WITH SUCTION HOSE LONG ENOUGH TO DEWATER FOREPEAK SPACE (MINIMUM 5 GPM).
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Accommodation/Occupational Safety
Issued 28 October 1987 Resolved
PROVIDE MEANS OF CLOSURE OF VENTS ON MAIN DECK BOTH SIDES OF HOUSE AND AFT OF HOUSE.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Engineering
Issued 28 October 1987 Resolved
MAKE PERMANENT REPAIR TO EXHAUST PIPING IN STBD AND CENTER ENGINES WHERE WASTED IN WAY OF COOLING WATER INJECTION.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Lifesaving
Issued 11 June 1987 Resolved
LABLE PFD STORAGE AREAS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Lifesaving
Issued 11 June 1987 Resolved
PROVIDE LIGHS FOR PFDS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Lifesaving
Issued 11 June 1987 Resolved
PROVIDE TWO WATERLIGHTS FOR LIFERAFTS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Engineering
Issued 11 June 1987 Resolved
REPAIR EMERGENCY FUEL OIL SHUT OFF TO ENGINEROOM.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Construction/Loadline
Issued 11 June 1987 Resolved
MAKE ENGINEROOM ESCAPE HATCH OPERATIONAL.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Construction/Loadline
Issued 11 June 1987 Resolved
MAKE FORWARD AND MIDSHIPS WATERTIGHTS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Lifesaving
Issued 11 June 1987 Resolved
MOUNT EPIRB OUTSIDE IN AN UNOBSTRUCTED AREA.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Construction/Loadline
Issued 27 June 1986 Resolved
DEMONSTRATE PROPER OPERATION OF THE FIXED ENGINE DRIVEN BILGE PUMP, A TEMPORARY PORTABLE BILGE PUMP OF NOT LESS THAN 25 GPM IS TO BE ON BOARD UNTIL FIXED PUMP OPERATIONAL.
Condition: Unknown
Due 27 June 1986
Resolved 27 June 1986
Construction/Loadline
Issued 27 June 1986 Resolved
RENEW BILGE STRAINERS IN CENTER COMPARTMENT AND STEERING GEAR VOID, WHERE WASTED.
Condition: Unknown
Due 27 June 1986
Resolved 27 June 1986
Lifesaving
Issued 18 June 1985 Resolved
PROVIDE ON BOARD 121 OPERABLE PERSONNEL FLOTATION DEVICE LIGHTS IAW 45 CFR 180.25-20.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.