MAURY USCG vessel records Sign in
← All vessels

PHILINE SCHULTE

PHILINE SCHULTE is a 1998 tank ship. The Coast Guard has recorded 38 inspections since 1999, most recently in May 2018, along with 14 deficiencies and 13 operational controls.

Records from 1999 to 2018. Most recent: inspection, 24 May 2018.

Built
1998
Last inspected
24 May 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9183570 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
496183
Flag
ISLE OF MAN
—
Maury page id
psix-496183

Inspections, by type

…with no type recorded23
Years with a record 14 calendar years (1999–2018)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11589 - Displacement, Metric Ton
7878 - Dead Weight, Metric Ton
6051 - Convention (Subpart B), Gross Ton
2398 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

24 May 2018 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6418320
17 May 2017 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6144974
16 May 2016 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5874448
3 December 2015 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5774823
21 May 2014 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4858509
25 June 2012 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4355809
8 May 2012 Type not recorded
No type recorded · Liquefied Gas Carrier National Center of Expertise · Activity 4305322
7 May 2012 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4299420
11 October 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3867905
16 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3363880
16 November 2008 COC-GAS Renew · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3364223
16 June 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2681884
16 February 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2586675
12 December 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2549878
1 December 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2544312
30 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2525489
29 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2526119
14 September 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2492128
6 September 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2508310
26 August 2005 COC-GAS Annual · Ballast Water Examination · ISPS III Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2475552
7 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2419446
19 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2343450
8 November 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2237026
5 November 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2236871
2 August 2004 COC-GAS Renew · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2154410
17 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293819
17 September 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1077111
29 January 2001 Tank Vessel Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1059488
28 January 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 499186
10 August 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 280723
23 March 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276096
18 July 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 430849
2 July 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 731577
10 June 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 731224
9 June 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 429552
9 June 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 501925
29 May 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 806038
24 May 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 428960

Deficiency record · 14

Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 24 May 2018 Resolved
1840-Instrumentation-Gas detection equipment should be capable of sampling & analysing for each sampling head location sequentially at intervalsnot exceeding 30 minutes. FWD store compartment sensor is not working; replacement part did not resolve issue. Vessel has requisitioned another sensor. Vessel crew will be designated to test atmosphere in FWD store compartment by portable gas detector to fulfill requirement. -74SOLAS VII/13.1 & '93 IGC Code 13.6.8
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 5 July 2018
Resolution: Received Class report verifying that the gas detection system was operational.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 May 2018 Resolved
1740-Oil Discharge Monitor/Control System- Oil filtering equipment should record date, time & alarm status, and operating status of 15 PPM bilge separator. PSCO discovered email documentation of a fault with OWS. Furtther inspection of OWS revealed incomplete data from recording device. Provide class report attesting to proper operation of oil content meter recording device. -Marpol Annex I/14.6
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 14 June 2018
Resolution: Cleared by installation of new 15PPM unit calibration date 2018-05-01. Class survey attached.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 7 May 2012 Resolved
Emergency Shutdown (ESD) valves in liquid piping should fully close under all service conditions within 30 seconds of actuation. The ESD quick closing valve on the #1 Stbd manifold did not fully close. Address to the satisfaction of attending classification society surveyor prior to using line for cargo operations (Cite: 74 SOLAS 09, Ch VII, Reg 13.1 - IGC Code 5.6.4)
Action required: 705 - Other - as specified
Due 20 May 2012
Resolved 25 June 2012
Resolution: Vessel submitted class report attesting to the proper operation and repair of the emergency shutdown valves.
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 November 2008 Resolved
Secondary Radra inoperable.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2008
Resolution: Vessel under 10000 GT. Devaition request not required. Released fron COTP Order.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 1 December 2005 Resolved
Echo depth sounder is not reading depth.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 2006
Resolved 12 December 2005
Resolution: Received technician report attesting to proper operation of vessels echo sounder. Transducer was replaced.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 30 October 2005 Resolved
Vessel reported an inoperable echo depth sounder while in port. Received tech report stating the depth sounder need to be tested vessel underway at sea. Outbound Deviation granted on 30OCT05. 01 def issued, 01 remains outstanding.
Action required: 705 - Other - as specified
Resolved 12 December 2005
Resolution: Received technician report attesting to proper operation of vessels echo sounder. Transducer was replaced.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 26 August 2005 Resolved
There is evidence of corrosion on the cargo vapor inlet to the port cargo condenser. Provide class verification that existing pipe thickness meets the requirements of the IGC Code CH. 5.2.
Action required: 705 - Other - as specified
Due 26 September 2005
Resolved 14 September 2005
Resolution: Received class report, cleared deficiency.
Deck/Cargo
Issued 10 August 2000 Resolved
Calibrate MSA (fixed) gas detection system prior to loading or discharging cargo in U.S. Port. SOLAS CHAP. I REG. XI.
Condition: Unknown
Due 31 January 2001
Resolved 31 January 2001
Navigation
Issued 18 July 1999 Resolved
Provide an operational "ARPA" in accordance with 33 CFR 164.38.
Condition: Unknown
Due 20 July 1999
Resolved 22 July 1999
Navigation
Issued 18 July 1999 Resolved
Provied an operational marine radar in accordance with 33 CFR 164.35(a).
Condition: Unknown
Due 20 July 1999
Resolved 22 July 1999
Fire Fighting
Issued 18 July 1999 Resolved
Repair the CARGO COOLING/DECK SPRAY pump's electrical system and provied a class report approving the repairs and operation of the deck spray system with the CARGO COOLING/DECK SPRAY PUMP.
Condition: Unknown
Due 20 July 1999
Resolved 22 July 1999
Navigation
Issued 9 June 1999 Resolved
VESSEL DID NOT HAVE A COPY OF THE U.S. INLAND/INTERNATIONAL NAVIGATIONAL RULES ON BOARD. VESSEL RECEIVED A COPY PRIOR TO DEPARTING FROM PORT.
Condition: Unknown
Due 10 June 1999
Resolved 10 June 1999
Navigation
Issued 9 June 1999 Resolved
VESSEL WAS MISSING CHART 18720. VESSEL RECEIVED A CORRECTED COPY PRIOR TO DEPARTING PORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1999
Resolved 10 June 1999
Unknown
Issued 9 June 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 1999
Resolved 10 June 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.