MAURY USCG vessel records Sign in
← All vessels

KING NEPTUNE

KING NEPTUNE is a 1978 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1985, most recently in July 2012, along with 99 deficiencies — 1 with no resolution recorded — and 3 casualty investigations between 2002 and 2014.

Records from 1985 to 2014. Most recent: casualty investigation, 31 December 2014.

Built
1978
Last inspected
18 July 2012
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9775
Flag
UNITED STATES
367316170
Maury page id
psix-49627

Inspections, by type

…with no type recorded7
…past their stated due date1
Years with a record 26 calendar years (1985–2012)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.1 ft × 19.1 ft × 8.0 ft
Registered tonnagegross 72 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKELLY'S BOAT SHOP · WESTPORT, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portAVALON, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
72 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD9775MMSI 367316170 · active · voluntarily equipped · granted 2 August 2017, expires 2 October 2027 · licensed under a name not among this hull’s recorded names (not shown)
WTT4795MMSI 366719710 · expired · compulsorily equipped · granted 28 May 1996, cancelled 29 July 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 55

18 July 2012 Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4373670
14 February 2012 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4244296
2 August 2011 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4104171
12 January 2011 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3925133
9 December 2008 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3372344
6 May 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3175578
19 July 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2952669
11 May 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2639025
13 May 2005 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2357186
15 December 2004 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2259221
29 June 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2117697
6 February 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001845
21 May 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1794112
3 December 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1713989
6 August 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1658387
17 June 2002 Annual Inspection · Drydock Extension
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1640298
16 May 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1426641
2 June 2000 Plan Review "T" Boat · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373129
1 June 2000 Damage Survey · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1413647
22 December 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 149591
8 December 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372842
12 April 1999 Deficiency Check · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365151
1 April 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 784267
1 February 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1427617
19 October 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 135785
8 October 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372377
13 April 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1469507
22 January 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368560
30 September 1997 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378173
7 April 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1446469
18 September 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 12408
10 April 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1400329
25 February 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 231716
22 September 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1383056
16 May 1995 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1238223
14 April 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 855196
11 May 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 859373
12 April 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1168507
14 April 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144944
11 January 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 828083
14 April 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1267145
8 January 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 956554
18 July 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 929037
21 February 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 916846
12 October 1990 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1226263
19 April 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 901871
19 April 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1198887
2 February 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1338164
8 June 1988 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1199761
2 June 1988 Re-Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1199924
17 July 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1330499
29 April 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1016245
9 July 1986 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 999379
24 April 1986 Credit Drydock · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 994209
13 March 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 979206

Deficiency record · 99

Stability › Incline Test › General
Issued 22 August 2012 Resolved
DEMONSTRATE VESSEL HAS ADEQUATE STABILITY FOR EXPOSED ROUTE BY CONDUCTING A STABILITY TEST WITNESSED BY ATTENDING COAST GUARD MARINE INSPECTOR. VESSEL LIMITED TO A ROUTE WHICH IS COASTWISE, NOT MORE THAN 20 MILES FROM MAINLAND SHORE UNTIL A NEW STABILITY LETTER HAS BEEN RECEIVED FROMT HE COAST GUARD. THIS ROUTE INCLUDES SANTA CATALINA, AND SANTA CRUZ AND WITHIN 2 MILES OF SANTA CRUZ ISLAND.
Action required: 705 - Other - as specified
Due 22 October 2012
Resolved 27 March 2013
Resolution: New amended COI and stability letter signed and sent to vessel.
Documentation › Logs/Records › Logbook (official)
Issued 2 August 2011 Resolved
Provide crew training and drill log.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: Training and drill log created.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 August 2011 Resolved
Secure battery below main helm on bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: Battery secured sat.
Lifesaving › Lifefloat › Lifeline
Issued 2 August 2011 Resolved
Remove tie-wraps from life lines on life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2011
Resolved 21 October 2011
Resolution: Vessel installed hydrostatic releases on primary lifesaving devices.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 August 2011 Resolved
Provide current alcohol test swabs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: New alcohol test swabs provided.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 2 August 2011 Resolved
Provide smoke detectors in over-night berthing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2011
Resolved 21 October 2011
Resolution: Vessel installed smoke detectors in overnight berthing spaces.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 2 August 2011 Resolved
Provide emergency lighting in over-night berthing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2011
Resolved 21 October 2011
Resolution: Vessel installed emergency lighting.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 August 2011 Resolved
Provide a protective guard around starboard generator's belts and pulleys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: Protective guard installed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 2 August 2011 Resolved
Repair excessive oil leak on portside generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: Generator oil leak repaired.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 August 2011 Resolved
Remove excess oil from engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: Excessive oil cleaned from bilge.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 August 2011 Resolved
Provide a guard on port main engine's belts and pulleys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: Protective guard installed.
Stability › Watertight Integrity › General
Issued 2 August 2011 Resolved
Provide watertight hatch on lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: New watertight hatches installed on lazeratte and fwd space.
Lifesaving › Lifefloat › Serviceable
Issued 2 August 2011 Resolved
Provide an unexpired battery for lifefloat water light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 21 October 2011
Resolution: Vessel installed new and correct batteries.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 2 August 2011 Resolved
Provide two (2) BII fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: New B-II extinguishers installed.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 2 August 2011 Resolved
Provide proof of inspection for fixed fire system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2011
Resolved 2 August 2011
Resolution: Corrected on the spot.
Engineering › Steering Gear System › Rudder
Issued 2 August 2011 Resolved
Repair or replace rudder post packing on portside rudder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: Rudder packing serviced sat.
Documentation › Logs/Records › Logbook (official)
Issued 2 August 2011 Resolved
Provide a log for life saving equipment inspections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2011
Resolved 2 September 2011
Resolution: Log for lifesaving inspections created.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 12 January 2011 Resolved
Replace lighting and remove all exposed wiring in port berthing area.
Action required: 705 - Other - as specified
Due 12 February 2011
Resolved 30 March 2011
Resolution: All exposed wiring in port berthing secured.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 January 2011 Resolved
Replace housing/contactor box for sonar board in air compressor area.
Action required: 705 - Other - as specified
Due 12 February 2011
Resolved 30 March 2011
Resolution: New contactor housing installed IWO sonar board.
Engineering › Fuel Oil Service System › Filter
Issued 12 January 2011 No resolution recorded
Replace safety cover for STBD racor fuel filter in engineroom.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2011 — due date passed with no resolution recorded
Resolution: Safety cover IWO STBD racor filter replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2009 Resolved
Remove all unused wiring
Action required: 705 - Other - as specified
Due 1 December 2009
Resolved 1 December 2009
Resolution: Corrected
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 December 2008 Resolved
Address Delaminating in Compressor Room IWO keel.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 9 January 2009
Resolution: Corrected
Construction/Loadline › Structures › Manhole
Issued 1 December 2008 Resolved
Clean forepeak hatch mating surface.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 9 January 2009
Resolution: Corrected
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 1 December 2008 Resolved
Provide Port shaft repair report.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 9 January 2009
Resolution: Corrected
Engineering › Shafting/Propeller Arrangements › Strut
Issued 1 December 2008 Resolved
Provide repair proposal for Port strut attachment bolts through hull.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 9 January 2009
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 December 2008 Resolved
Provide cable at port hand rail luggage loading area.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 9 January 2009
Resolution: Corrected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 July 2007 Resolved
Provide Engine Room Fixed Fire Fighting servicing report prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2007
Resolved 20 July 2007
Resolution: Received satisfactory servicing report.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 July 2007 Resolved
Provide machinery guards for port and starboard generator sets.
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 19 July 2007
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 July 2007 Resolved
Provide alcohol testing devices as required by 46 CFR 4.06-15(a).
Action required: 705 - Other - as specified
Due 19 August 2007
Resolved 26 July 2007
Resolution: Received documentation concerning testing devices.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 16 May 2005 Resolved
Replace/ recharge fixed firefighting
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2005
Resolved 19 May 2005
Lifesaving › Hand Flares › Quantity
Issued 16 May 2005 Resolved
Provide six orange signaling devices(flares)
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 19 May 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 December 2004 Resolved
Replace ball valve on through hull fitting on starboard side as planned for dry dock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 December 2004
Resolved 18 December 2004
Resolution: Replaced valve and inspected by [name withheld].
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 15 December 2004 Resolved
Replace cables on all hatch covers as planned during dry dock period.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 December 2004
Resolved 16 May 2005
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 15 December 2004 Resolved
Clean and/or replace seals on forward hatch cover.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 December 2004
Resolved 15 December 2004
Construction/Loadline › Structures › Scupper
Issued 15 December 2004 Resolved
Repair damage to starboard quarter deck scupper as planned during dry dock period.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 December 2004
Resolved 18 December 2004
Resolution: Damage repaired and inspected byCWO Efram.
Electrical
Issued 2 June 2000 Resolved
Install metal hangars (straps) to support electrical wiring through-out theengine room.
Condition: Unknown
Due 2 July 2000
Resolved 15 August 2000
Engineering
Issued 2 June 2000 Resolved
Secure fuel line manifold in engine room.
Condition: Unknown
Due 2 July 2000
Resolved 15 August 2000
Construction/Loadline
Issued 2 June 2000 Resolved
Provide bilge pumping system drawing for approval.
Condition: Unknown
Due 2 July 2000
Resolved 15 August 2000
Navigation
Issued 2 June 2000 Resolved
Demonstrate operation of the Medium Frequency (SSB) radio. Vessel may not operate more than 60 miles from a base-line extending from Point Conceptionto Cabo San Lucas, Mexico until this item is cleared.
Condition: Unknown
Due 2 July 2000
Resolved 15 August 2000
Fire Fighting
Issued 2 June 2000 Resolved
Provide servicing report for fixed fire system in engine room.
Condition: Unknown
Due 2 June 2000
Resolved 15 August 2000
Unknown
Issued 2 June 2000 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Fire Fighting
Issued 2 June 2000 Resolved
Provide smoke detectors for accomadation areas. This item must be corrected prior to carrying passengers overnight.
Condition: Unknown
Due 2 July 2000
Resolved 15 August 2000
Lifesaving
Issued 2 June 2000 Resolved
Mark all lifejacket storage locations.
Condition: Unknown
Due 2 July 2000
Resolved 15 August 2000
Lifesaving
Issued 2 June 2000 Resolved
Replace all expired medicines in first aid kit.
Condition: Unknown
Due 2 July 2000
Resolved 15 August 2000
Electrical
Issued 2 June 2000 Resolved
Provide plans for D.C. electrical system in engine room.
Condition: Unknown
Due 3 June 2000
Resolved 15 August 2000
Lifesaving
Issued 2 June 2000 Resolved
Provide emergency lighting in accomadation spaces. This item must be corrected prior to operating with passengers overnight.
Condition: Unknown
Due 2 July 2000
Resolved 15 August 2000
Unknown
Issued 2 June 2000 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Engineering
Issued 2 June 2000 Resolved
Provide belt guards on generators and shaft guards on main engine propellorshafts.
Condition: Unknown
Due 2 July 2000
Resolved 15 August 2000
Lifesaving
Issued 2 June 2000 Resolved
Provide information for a drug audit.
Condition: Unknown
Due 3 June 2000
Resolved 15 August 2000
Unknown
Issued 2 June 2000 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Lifesaving
Issued 1 June 2000 Resolved
VESSEL IS HEREBY RESTRICTED FROM OPERATION WITH PASSENGERS UNTIL VESSEL IS INSPECTED BY A MARINE INSPECTOR AND APPROVED TO RESUME OPERATION.
Condition: Unknown
Due 1 June 2000
Resolved 14 July 2000
Navigation
Issued 12 April 1999 Resolved
Provide current deviation table.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Navigation
Issued 12 April 1999 Resolved
Provide complete VHF emergency placard.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Construction/Loadline
Issued 8 October 1998 Resolved
Install metalic shutoff valve(s) per 46/182.720 in bilge piping that contains, in whole or in part, non-metalic piping where it passes through watertight bulkheads.
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Construction/Loadline
Issued 13 April 1998 Resolved
Renew bilge system in engine room, including manifold, piping and bulkhead penetrations with metallic material per 46 CFR 182.710.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Lifesaving
Issued 13 April 1998 Resolved
Provide serviceable ring life buoy.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Lifesaving
Issued 14 April 1995 Resolved
PROVIDE NEW HYDRO-STATIC RELEASE FOR EPIRB
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Navigation
Issued 11 May 1994 Resolved
PROVIDE UPDATE TO CHARTS, NOTICE TO MARINERS AND LIGHT LISTING.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Electrical
Issued 11 May 1994 Resolved
PROVIDE NON STATIC ELECTRICAL HANDLE FOR SHORE TO SHIP POWER CONTROL SWITCH.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Lifesaving
Issued 11 May 1994 Resolved
PROVIDE 6 RED FLARES.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Lifesaving
Issued 11 May 1994 Resolved
PROVIDE 2 CHILD PFD,S TYPE I BEFORE CARRING MORE THAN 4 CHILDREN .
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Accommodation/Occupational Safety
Issued 11 May 1994 Resolved
PROVIDE WAY TO SECURE MSD SUCTION TO PUMP.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Engineering
Issued 12 April 1994 Resolved
REPAIR EXHAUST LEAK ON PORT ENGINE BEFORE OPERATING.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Documentation
Issued 12 April 1994 Resolved
LOCATE OR REPLACE COD TAG FOR YEAR DATED 1995.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Navigation
Issued 14 April 1993 Resolved
PROVIDE CURRENT EDITION CHARTS OF OPERATING AREAS.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Lifesaving
Issued 14 April 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Documentation
Issued 14 April 1993 Resolved
PROVIDE EVIDENCE OF COMPLYING WITH THE REQUIREMENTS IN 46 CFR 16 FOR CHEMICAL (DRUG) TESTING OF CREW, INCLUDING RANDOM TESTING.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Accommodation/Occupational Safety
Issued 14 April 1992 Resolved
REPLACE CENTER WINDOW IN CABIN THAT IS CRACKED.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Construction/Loadline
Issued 14 April 1992 Resolved
PROVIDE COVER FOR PORTLIGHT IN MALES HEAD STBD SIDE.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Electrical
Issued 14 April 1992 Resolved
DEAD-END WIRES IN FOREPEAK TO JUNCTION BOX OR REMOVE WIRES.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 19 April 1990 Resolved
REPLACE ALL ORANGE SMOKE AND RED FLARE VISUAL DISTRESS SIGNALS.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Accommodation/Occupational Safety
Issued 19 April 1990 Resolved
REPLACE PORTHOLE COVERS IN BOTH HEADS.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Lifesaving
Issued 19 April 1990 Resolved
REPAIR OR REPLACE 3 CHILDREN'S PFD'S.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Navigation
Issued 19 April 1990 Resolved
REPLACE BATTERY IN EPIRB.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Electrical
Issued 19 April 1990 Resolved
COVER OPEN SPACE ON CIRCUIT BREAKER PANEL ON FORWARD BULKHEAD OF ENGINE ROOM.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Electrical
Issued 19 April 1990 Resolved
PROVIDE METAL SUPPORTS (WITH CHAFING PROTECTION) EVERY 24 INCHES ON ELECTRICAL CABLE IN ENGINE ROOM.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Electrical
Issued 19 April 1990 Resolved
PROPERLY SPLICE WIRES IN JUNCTION BOX ON AFT BULKHEAD OF SPACE UNDER GALLEY.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Fire Fighting
Issued 19 April 1990 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS AND PROVIDE A B-I PORTABLE FIRE EXTINGUISHER FOR PILOT HOUSE.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Lifesaving
Issued 19 April 1989 Resolved
PROPERLY ATTACH PENDANTS AND RETROREFLECTIVE TAPE TO LIFE FLOATS.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Lifesaving
Issued 19 April 1989 Resolved
PROVIDE LIGHTS FOR PFD'S.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Electrical
Issued 19 April 1989 Resolved
PROPERLY HARDWIRE VENT EXHAUST FANS, MIDBODY COMPRESSOR ROOM.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Electrical
Issued 19 April 1989 Resolved
PROVIDE METAL SUPPORTS TO WIRING IN ENGINEROOM.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Fire Fighting
Issued 19 April 1989 Resolved
PROVIDE PROOF OF PORTABLE FIRE EXTINGUISHER SERVICING.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Electrical
Issued 19 April 1989 Resolved
PROPERLY PROTECT ENGINE ROOM ELECTICAL BOXES FROM MOISTURE DAMAGE.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Documentation
Issued 19 April 1989 Resolved
OBTAIN AND POST VESSEL STABILITY LETTER.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Lifesaving
Issued 29 April 1987 Resolved
REPLACE ALL PFD LIGHT BATTERIES OR REPLACE THE LIGHTS.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Accommodation/Occupational Safety
Issued 29 April 1987 Resolved
INSTALL A LATCHING DEVICE FOR THE OVEN DOOR.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
PROVIDE SUITABLE MOUNTING BRACKETS FOR THE LIFE FLOAT WATER LIGHTS.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Electrical
Issued 29 April 1987 Resolved
PROPERLY LABEL THE CIRCUIT BREAKERS IN THE DISTRIBUTION PANEL ON THE FORWARD BULKHEAD OF THE ENGINEROOM.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Engineering
Issued 29 April 1987 Resolved
REPAIR THE WATER LEAK IN THE STARBOARD MAIN ENGINE EXHAUST COOLING WATER LINE.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Documentation
Issued 29 April 1987 Resolved
PROVIED AND POST THE FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Documentation
Issued 29 April 1987 Resolved
POST THE VSL. STABILITY LETTER IN THE WHEELHOUSE.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Construction/Loadline
Issued 29 April 1987 Resolved
STENCIL THE VSL'S HAILING PORT ON THE TRANSOM.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
PROVIDE 6 ORANGE SMOKE FLARES.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
PROVIDE NEW BATTERIES FOR THE LIFE RING AND LIFE FLOAT WATER LIGHTS.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
STENCIL THE VESSEL'S NAME ON THE LIFE FLOAT PADDLES.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Engineering
Issued 29 April 1987 Resolved
REPLACE THE VALVE HANDLES FOR THE FUEL SHUT OFF VALVES LOCATED IN THE STEERING GEAR COMPARTMENT. THESE VALVES ARE TO REMAIN CLOSED UNTIL THIS ITEM IS COMPLETE.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Fire Fighting
Issued 29 April 1987 Resolved
SERVICE THE VESSEL'S PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Engineering
Issued 9 July 1986 Resolved
RENEW PORT PROPELLAR SHAFT
Condition: Unknown
Due 9 July 1986
Resolved 9 July 1986

Casualty record · 3

6 August 2002Routine · role: Involved in a Marine Casualty · 1 dead · activity 1658387
9 September 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4980246
31 December 2014Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5756033
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.