Records from 2016 to 2022. Most recent: operational control imposed, 26 August 2022.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 68
26 August 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7543967
7 July 2022
PSC A · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7499274
4 July 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7492870
2 June 2022
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7466044
28 May 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7460931
29 April 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7440591
1 April 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7422805
8 March 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7407171
8 January 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7377260
29 November 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7357123
29 November 2021
Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7359031
1 November 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7342618
30 September 2021
Deficiency Check · CCSSC Examination · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7322419
29 September 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7321314
23 August 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7292153
23 August 2021
CCSSC Examination · Deficiency Check · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7294097
19 July 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7257971
15 July 2021
PSC A · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7257131
24 May 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7203949
19 April 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7176506
22 March 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7158489
15 February 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7140349
21 January 2021
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7126291
18 January 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7125893
7 December 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7106978
16 November 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7093893
8 October 2020
Administrative Inspection · PSC A · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7071510
5 October 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7070990
5 September 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7050645
6 July 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6996191
10 March 2020
PSC A · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6923688
8 March 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6903933
6 February 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6904190
13 January 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6886987
28 November 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6864211
11 November 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6853305
20 October 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6837119
22 September 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6818828
21 September 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6817219
26 August 2019
Deficiency Check · ISPS III Exam · PI Safety Exam · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6792559
25 August 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6792201
4 August 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6769269
8 July 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6741424
13 June 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6712670
24 May 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6692426
26 April 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6671307
7 April 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6656431
21 February 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6629446
21 February 2019
CCSSC Examination · PII Safety Exam · Deficiency Check · Administrative Inspection · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6629721
11 January 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6609177
9 December 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6592746
16 November 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6581843
28 September 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6550579
14 August 2018
Ballast Water Examination · Deficiency Check · CCSSC Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6511447
10 August 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6507440
9 July 2018
CCSSC Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6472664
8 July 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6471358
16 June 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6446043
18 May 2018
PI Safety Exam · ISPS I Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6417596
18 May 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6417707
26 April 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6399975
1 March 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6364085
8 February 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6351998
31 October 2017
Ballast Water Examination · ISPS II Exam · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6296137
18 April 2017
ISPS II Exam · Deficiency Check · Ballast Water Examination · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6126983
14 January 2017
CCSSC Examination · Administrative Inspection · ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6070964
12 October 2016
Deficiency Check · ISPS II Exam · Administrative Inspection · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6021097
7 June 2016
Ballast Water Examination · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5900310
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 7 July 2022
Resolved
“A life raft or life rafts capable of being launched on either side of the ship and of such aggregate capacity as will accommodate the total number of persons onboard.” PSCO’s identified 01 missing life raft on the starboard side.
CCSS 4.4.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2022
Resolved 9 July 2022
Resolution: Operator sent picture of liferafts onboard and servicing report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2022
Resolved
Electrical installations shall be such that: the safety of personnel and ship from electrical hazards will be assured. Shore power connection was severely frayed and spliced in multiple locations on the wet deck.
CCSS 2.26.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2022
Resolved 9 July 2022
Resolution: Operator sent picture of new cable purchased, as long as receipt.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2021
Resolved
Any alterations, modifications or renewals of shipboard equipment as a result of a survey shall be recorded in the ships record of equipment. Vessel was issued a new Caribbean Cargo Ships Safety Certificate on 04Oct2021. Record of equipment and ships information does not accurately reflect the equipment and certificates onboard.
CCSS Code 1.10.8
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2021
Resolved 6 December 2021
Resolution: Class updated CCSSC to reflect equipment onboard.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 30 September 2021
Resolved
EVERY SHIP ASSIGNED RESTRICTED AREA II,III AND UNRESTRICTED SHALL CARRY AT LEAST ONE SATELLITE EMERGENCY POSITION INDICATIONG RADIO BEACON(EPIRB)... CAPABLE OF TRANSMITTING A DISTRESS ALLERT. THE EPIRB TEST BUTTON IS INOPERABLE AND PSCOS ARE UNABLE TO VERIFY ITS POERATION. CCSS CODE CH 5.3.1 17 B,C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2021
Resolution: Vessel received new EPIRB and PSCOs verified EPIRB was registered, properly installed, and tested successfully.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 August 2021
Resolved
Every ship shall be provided with at least one independent power operated fire pump capable of delivering a jet of water as required by regulation 3.3.2 vessels fire pump will not run unless manually bypassed at the relay. CCSS code 3.3.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2021
Resolution: Fire pump motor controller reset button was replaced. Pump was tested and found satisfactory.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 23 August 2021
Resolved
Ships of less than 300 Gross tonnage certified for operations in restricted area III shall as a minimum requirement carry ... two portable waterproof two way VHF GMDSS radio telephone apparatus to be used in survival craft. both GMDSS radios were inoperable. CCSS code 5.1.2 17ABC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2021
Resolution: Vessel replaced the 02 inoperable GMDSS radios and provided new spare batteries.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 August 2021
Resolved
Any alterations, modifications or renewals of ship board equipment as a result of a survey shall be recorded in the ships record of equipment. vessels record of equipment shows Johnson 9.5 HP instead of actual rescue boat engine Yamaha 15 HP CCSS code 1.10.8 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 August 2021
Resolution: CCSSC Certificate was updated to show proper rescue boat motor and also updated to show new GMDSS radio serial numbers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2021
Resolved
Every ship shall be provided with a minimum of 2 fire hoses. 03 fire fighting hoses on board are not rated for fire fighting.
CCSSC Reg. 3.5.1
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2021
Resolved 23 July 2021
Resolution: Vessel provided two new proper firefighting hoses and removed the extra hose that was not rated for firefighting.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 21 July 2021
Resolved
Clear instructions to be followed in the event of an emergency shall be provided and exhibited in spaces throughout ship including the navigation bridge. Emergency instructions not in bridge or machinery space.
CCSS Code Reg 4.16.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 23 August 2021
Resolution: Instructions to be followed in the event of an emergency were provided and posted on the bridge and machinery space.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangements rescue boats
Issued 20 July 2021
Resolved
Suitable arrangements shall be made to the satisfaction of the administration for the embarkation into survival craft. Which shall include one or more embarkation ladders. Starboard side embarkation ladder broke during exam. Port side embarkation ladder has 02 broken steps.
CCSS Code Reg 4.10.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2021
Resolved 23 July 2021
Resolution: Vessel installed new embarkation ladders, port and starboard side.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 20 July 2021
Resolved
Above deck of hatchway coamings fitted with weathertight hatch covers of steel or other equivalent material fitted with gaskets. Escape hatch in engine room was observed to have light leaks resulting in the hatch not meeting weather tight requirements.
ILLC Reg 16.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 21 July 2021
Resolution: Gasket replaced on hatch.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 20 July 2021
Resolved
Every ship shall be provided with a general emergency alarm the general alarm in machinery spaces shall be audible and visible revolving red light. General alarm is not audible or visible in engine room.
CCSS Sode Reg 4.15
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 July 2021
Resolved 20 July 2021
Resolution: General alarm operates properly.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 July 2021
Resolved
Any certificate required by the convention must be kept available in its original form on board the ship on which the holder is serving. [name withheld] certificates were not onboard the vessel.
STCW I/2.11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 July 2021
Resolved 20 July 2021
Resolution: Engineer went and got his certificates.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 October 2020
Resolved
Life saving appliances required... shall comply with.. the LSA Code 06 life buoys on-board did not have approval marking.
CCSSC 4.3 LSA Code 1.2.2.9
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2020
Resolution: Proof of type approval provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 October 2020
Resolved
Ships of less than 300 GT... Shall as a minimum requirement carry two GMDSS compliant VHF DSC main radio apparatus and two portable waterproof two-way VHF apparatus. Vessel is missing 02 waterproof VHF radios and 01 battery for GMDSS radios.
CCSSC 5.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2020
Resolution: 02 radios witnessed onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 8 October 2020
Resolved
The certificate referred to in 1.12.1 shall be supplemented by a Record of Equipment and Ship Information which shall be permanently attached thereto. Record of Equipment missing.
CCSSC 1.12.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2020
Resolution: Record of equipment provided and verified onboard the vessel.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 8 October 2020
Resolved
Every ship of 100GT and above... shall carry a garbage management plan which the crew shall follow. Crew is not following record keeping requirements established in their garbage management plan by not recording all categories of garbage disposed, estimated quantities are not being recorded in cubic meters.
MARPOL Annex V Reg. 10.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2020
Resolved 31 October 2020
Resolution: Records submitted showing correct entry types and recorded in cubic meters instead of gallons.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 August 2019
Resolved
The lines which indicate the load line assigned in accordance with these regulations... forward of the centre of the ring. The port side load line marks are abaft of the center line.
ICLL 66/68 Annex 1 Reg. 6.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 9 September 2019
Resolution: Vessel sent in a Flag report from Zanzibar. Attached in documents.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 19 March 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2019
Resolved 21 March 2019
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 14 August 2018
Resolved
The ILLC shall not be delivered to the ship until the marks are correctly and permanently indicated on the ship's side. The vessel's load line does not match the certificate. - ICLL66 Annex I/9
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2018
Resolved 17 August 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 August 2018
Resolved
All access openings in bulkheads shall be fitted with doors so that the whole structure is weathertight when closed. The main door leading into the superstructure on the main deck can not properly seal and effectively keep water out. Vessel cleaned up the knife edge on door to properly seal in the gasket. - ICLL66 Annex I/12(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 August 2018
Resolved 14 August 2018
Resolution: Vessel chipped paint to enable to door to properly seal.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 August 2018
Resolved
The position of the rudder shall be indicated at the navigation bridge. The rudder angle indicator does not properly indicate the position of the rudder. STBD side was off by 5 degrees, Port side was off by 12. - CCSSC 2.33.8
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2018
Resolved 17 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 9 July 2018
Resolved
0699- CCSSC Ch 4.17- In all ships training in the procedures specified in accordance with 4.16 should be carried out at least once per month. Crew was unfamiliar with lifesaving equipment including liferaft and embarkation ladder.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2018
Resolved 17 July 2018
Resolution: Training in liferaft and embarkation ladder familiarity took place. Training was logged in the vessels logbook.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 9 July 2018
Resolved
2120- MARPOL annex V/10.2 Every ship of 100 GT or above shall carry a garbage management plan which the crew shall follow. Vessel could not provide a garbage management plan.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2018
Resolution: Garbage Management Plan was created and approved by flag. Captain and Crew have signed and ackowledged understanding of the Plan.
Operations/Management › Drills/Instruction › Fire
Issued 18 April 2017
Resolved
0925-MUSTER/DRILLS- Training drills shall as far as practicable be conducted as if they were an actual emergency. Crew was unfamiliar with fire fighting equipment, procedures, and were unable to perform a satisfactory fire drill. CCSSC 4/4.17.2
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 April 2017
Resolution: Drill was conducted again after training was conducted with the crew and was found satisfactory.
Operations/Management › Drills/Instruction › Fire
Issued 18 April 2017
Resolved
0735-FIRE FIGHTING APPLIANCE- Training drills should be as far as practicable be conducted as if there were an actual emergency. Crew qas unfamiliar with fire fighting equpiment and improperly donned breathing apparatus. CCSSC 4/4.1.7.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 18 April 2017
Resolution: Drill was conducted again and personnel demonstrated proper use of equipment.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 18 April 2017
Resolved
0810 - Personal Equipment-Accid-Prevent - All ships shall be provided with a minimum of two EEBD's. The two EEBD's onboard and listed on the Fire Control Plan were inoperable. CCSSC 3/ 3.15.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2017
Resolution: EEBD'S were visually inspected and found satisfactory.
Fire Fighting › Fire Pumps › Arrangement
Issued 18 April 2017
Resolved
0740-PUMPS- An emergency fire pump shall be permanently connected to the fire mains. Emergency fire pump is a portable fire pump affixed to the deck sourcing water through a flex hose. CCSSC 3/3.3.10.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2017
Resolution: Witnessed operational test of emergency fire pump and verified correct installation.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 18 April 2017
Resolved
0750-FIRE FIGHTING APPLIANCES- If the welding or hot work is on the boundary of a compartment, a fire watch, in addition to that called for in nfpa 51B, must be stationed in the adjoining compartment. Welding and hot work conducted on the starboard side load line had no fire watch in the adjoining compartment. 33CFR126.309(g)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 18 April 2017
Resolution: Crew ceased welding and was trained on proper procedures.
Fire Fighting › Combustible Materials › Insulation
Issued 18 April 2017
Resolved
0830-FFA- Owner/MAster should ensure that the condition of the ship is maintained... Starboard main engine exhaust pipe lagging in aft engine room found deteriorated exposing the pipe. CCSSC 1/1.11.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2017
Resolution: Lagging was visually verified and was corrected.
Construction/Loadline › Markings › Load Line Mark
Issued 18 April 2017
Resolved
1220-FREEBOARD MARKS- The ILLC shall not be delivered to the ship until the officer or surveyor... has certified the marks are currently indicated on the ship's sides. Vessel's load line markings do not reflect the load line marks as indicated on the ship's certificate. ICLL 66 ANEX I/REG 9
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2017
Resolution: Load line was corrected to accurately reflect the certificate.
Personnel › Certificates/Documents/Licenses › Certificate of Registry, Purser
Issued 18 April 2017
Resolved
0199-CERTIFICATES- All certificates shall be readily available on board for examination at all times. Certificate of registry was not on board during time of inspection. CCSSC 1/1.15.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2017
Resolution: Copy of Registry was verified onboard.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 18 April 2017
Resolved
0628-STOWAGE- Every ship shall carry liferafts of such aggregate capacity for the total # of persons onboard. 01 liferaft was missing for maintenance and remaining liferaft did not have a hydrostatic release. CCSSC 4/4.4.1.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2017
Resolution: All liferafts were put back in service, verified hydrostatic releases were not expired.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2017
Resolved
0925- MUSTER/DRILLS- The master shall ensure that the frequency of drills performed shall not exceed the frequencies in the Code. No records of drills could be provided except for on 16APR17.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2017
Resolution: Drills were conducted and logged in the offical log book.
Documentation › Logs/Records › Logbook (official)
Issued 18 April 2017
Resolved
0190-LOG BOOK- Every vesel shall have a log book and the master shall make or have made all pertinent entries required by this part. Entries made in the log book were inconsistent, incomplete, and did not have required information, dating back from January 2017 to present.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2017
Resolution: Log book was reviewed and had sufficient entries.
Construction/Loadline › Structures › Deck Plating
Issued 18 October 2016
Resolved
0930 - Stability/Strength - The Administration shall satisfy itself that the general structural strength of the ship is adequate for the draught corresponding to the freeboard assigned to the vessel. While performing an exam of the vessel's engine room, the PSCO observed several deformed frames and load bearing beams. ICLL 66/88/ Annex I Reg 1(1)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2016
Resolution: Received Flag Attestation and PSCO verified proper repairs made to structural members.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 18 October 2016
Resolved
0810 - Personal Equipment-Accid-Prevent - All ships shall be provided with a minimum of two EEBD's. The two EEBD's onboard and listed on the Fire Control Plan were inoperable. CCSSC (15 Cons.) Ch. 3 / Reg 3.15.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2016
Resolution: Received Flag Attestation and PSCO verified proper refilling of EEBD's.
Lifesaving › Rescue Boat › Weathertight Stowage
Issued 18 October 2016
Resolved
0616 - Rescue Boat Inventory - Life saving appliances required by this chapter shall comply with the LSA Code. All items of the rescue boat equipment shall be secured within the lifeboat. CCSSC (15 Cons.) Ch. 4 / Reg. 4.3.1 LSA Code CH V/5.1.2.1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 October 2016
Resolved 18 October 2016
Resolution: All required rescue boat equipment was placed and secured in the rescue boat.
Communications › Alarms/Indicators › General Alarm
Issued 18 October 2016
Resolved
1010 - General Alarm - The general alarm in machinery spaces shall be audible and visible (revolving red light). The engine room is not equipped with a general alarm that is visible. CCSSC (15 Cons.) Ch. 4 / Reg. 4.15
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 25 October 2016
Resolution: recieved flag state report, psc team verified corrections.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 October 2016
Resolved
0190 -Ship's Logbooks/compulsory entries - The master shall ensure that the frequency of drills performed on board the ship for enclosed space drills are quarterly. Vessel could not provide proof of drills being conducted. CCSSC (15 Cons.) Ch. 7 / Reg 7.4.3.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 October 2016
Resolution: Received Flag Attestation and PSCO verified proper logging of drills.
Construction/Loadline › Structures › Deck Plating
Issued 8 June 2016
Resolved
0930: See narrative and attached form B for details. 30bc
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 18 July 2016
Construction/Loadline › Hull › Hull Plating
Issued 8 June 2016
Resolved
0900: See narrative for details. 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2016
Resolution: Received attestation letter from the vessel's flag administration and verified repairs. Def cleared