MAURY USCG vessel records Sign in
← All vessels

JENNI LEE

JENNI LEE is a 1978 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1981, most recently in June 2007, along with 28 deficiencies.

Records from 1981 to 2007. Most recent: inspection, 10 June 2007.

Built
1978
Last inspected
10 June 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAM4072
Flag
UNITED STATES
366763510 (licence lapsed)
Maury page id
psix-49643

Inspections, by type

…with no type recorded10
Years with a record 21 calendar years (1981–2007)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCY9495MMSI 366763510 · cancelled · compulsorily equipped · granted 24 March 1999, cancelled 25 February 2004
WCW5497MMSI not assigned · expired · compulsorily equipped · granted 7 May 1996, cancelled 8 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

10 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2956967
23 June 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1821733
29 April 2002 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1611014
1 June 2001 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1469688
22 August 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 446528
26 May 2000 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 817933
26 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818735
23 May 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450478
3 April 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424892
25 March 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212136
21 June 1999 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 882821
21 May 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 799298
14 May 1999 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1365249
16 July 1998 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1441400
12 February 1998 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1408051
8 August 1997 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 782148
9 July 1997 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1419801
18 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1103225
21 May 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1457371
16 February 1996 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1443661
22 May 1995 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1382963
7 June 1994 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1458166
25 May 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 861267
25 May 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1451980
7 February 1994 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1463808
15 June 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1150639
27 May 1993 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1147945
2 June 1992 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1267439
23 January 1992 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1145062
26 September 1991 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 934466
25 September 1991 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1243933
3 June 1991 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1226824
3 June 1991 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1229965
6 June 1990 Hull Examination · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 931406
9 December 1986 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1022236
5 June 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 980300
7 November 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 974589
5 June 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280890
3 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967354
9 November 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279174
6 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965020
7 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969937

Deficiency record · 28

Communications › Alarms/Indicators
Issued 23 June 2003 Resolved
Demonstrate proper operation of bilge alarms. LEGACY COMPONENT DESC: Bilge Alarm
Due 26 June 2003
Resolved 24 June 2003
Construction/Loadline › Structures
Issued 23 June 2003 Resolved
Crop & renew hatch frame in forepeak. LEGACY COMPONENT DESC: Scuttle
Due 26 June 2003
Resolved 24 June 2003
Electrical
Issued 1 June 2001 Resolved
Install wire ties in way of workroom and engine room in accordance with 46 CFR 183.34.
Condition: Unknown
Due 14 June 2001
Resolved 19 June 2001
Construction/Loadline
Issued 1 June 2001 Resolved
Install and prove proper operation of high level bilge alarm IWO wheelhouse.
Condition: Unknown
Due 1 June 2001
Resolved 5 June 2001
Engineering
Issued 1 June 2001 Resolved
Install flame screens on fuel vents (4) in accordance with 46 CFR 182.450(e).
Condition: Unknown
Due 14 June 2001
Resolved 19 June 2001
Documentation
Issued 1 June 2001 Resolved
Post Emergency Broadcast Placard (instructions and vessel information) by radio in accordance with 46 CFR 184.506 and 184.510.
Condition: Unknown
Due 14 June 2001
Resolved 19 June 2001
Electrical
Issued 1 June 2001 Resolved
Install wire tie's on bridge in accordance with 46 CFR 183.34.
Condition: Unknown
Due 14 June 2001
Resolved 19 June 2001
Navigation
Issued 1 June 2001 Resolved
Install and prove proper operation of public address system in accordance with 46 CFR 184.610.
Condition: Unknown
Due 14 June 2001
Resolved 19 June 2001
Documentation
Issued 23 May 2000 Resolved
46 CFR 176.302: CERTIFICATE OF INSPECTION VALID BUT NOT ONBOARD. PROVIDE ORIGINAL TO BE POSTED IAW THE ABOVE. CORRECTION OF THIS REQUIREMENT SHALL BE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NLT 6/23/00
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Fire Fighting
Issued 14 May 1999 Resolved
DEMONSTRATE SUFFICIENT WATER PRESSURE FROM FIRE PUMP & HOSES IN SUFFICIENT TIMELY FASHION TO SATISFACTION OF ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 June 1999
Resolved 23 June 1999
Construction/Loadline
Issued 14 May 1999 Resolved
INSTALL QUICK ACTIVIATING WATERTIGHT DOOR BETWEEN PASSENGER ACCOMODATION & MACHINERY SPACES AT NEXT CREDIT DRYDOCKING.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 14 May 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 June 1999
Resolved 23 June 1999
Engineering
Issued 9 July 1997 Resolved
PROVIDE A RELIABLE MEANS FOR SHUTTING DOWN THE PROPULSION PLANT FROM THE CONTROL STATION IN THE PILOT HOUSE, WHICH IS INDEPENDENT OF THE ENGINE'S SPEED CONTROLS. I.A.W. 46 CFR 184.620 (2.B)
Condition: Unknown
Due 9 July 1997
Resolved 9 July 1997
Engineering
Issued 21 May 1996 Resolved
PROVIDE PRESSURE VESSEL RELIEF VALVES THAT OPERATE IAW 46 CFR 54.15-5 THRU 10.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Navigation
Issued 21 May 1996 Resolved
CORRECT CHARTS 11340 & 11300 PRIOR TO OPERATING IN THE RESPECTIVE ZONES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Navigation
Issued 21 May 1996 Resolved
OBTAIN REQUIRED NOTICE TO MARINERS PRIOR TO SAILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Navigation
Issued 21 May 1996 Resolved
OBTAIN LIGHT LIST PRIOR TO SAILING.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Lifesaving
Issued 21 May 1996 Resolved
PROVIDE REFLECTIVE TAPE FOR BOTTOM OF 25 MAN LIFE RAFT.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
PROVIDE LEVEL INDICATOR FOR MSD TO INDICATE WHEN 3/4 FULL OR MORE. 33 CFR 159.83_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Unknown
Issued 21 May 1996 Resolved
PROVIDE DOCUMENTATION FOR RECORDKEEPING OF THE WASTE MAGEMENT PLAN 33 CFR 155.55
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
MAIN DECK MSD SHALL NOT BE OPERATED UNTIL IT COMPLIES WITH 33 CFR 159.7(a).
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
PROVIDE A LINT SCREEN/TRAP FORM CLOTHES DRYER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Navigation
Issued 21 May 1996 Resolved
PROVIDE SHART 11347 PRIOR TO SAILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Electrical
Issued 25 May 1994 Resolved
INSTALL PROPER METAL FLAME GUARDS ON RACOR FUEL FILTERS ON BOTH GENERATORS.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Electrical
Issued 25 May 1994 Resolved
INSTALL A METAL COVER OVER EXPOSED BREAKER SWICHES ON MAIN DISTRIBUTION PANEL FOR GENERATORS.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Electrical
Issued 27 May 1993 Resolved
PERMANANTLY WIRE CENTER DECK LIGHT ON UPPER DECK AFT.
Condition: Unknown
Due 16 June 1993
Resolved 22 June 1993
Electrical
Issued 27 May 1993 Resolved
COVER OPEN BREAKER SLOTS IN GALLEY AND WORK ROOM DISTRIBUTION PANELS.
Condition: Unknown
Due 16 June 1993
Resolved 22 June 1993
Construction/Loadline
Issued 27 May 1993 Resolved
MAKE PERMANENT REPAIRS TO BROKEN SLIDING DOG RETAINER ON FOREPEAK HATCH.
Condition: Unknown
Due 16 June 1993
Resolved 22 June 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.