13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2026
Resolved
Auxiliary machinery of the internal combustion piston type must comply with the provisions of this part. A portable gasoline generator was found stored unsecured above the passenger deck canopy. This unauthorized installation poses stability risks by altering the vessel's lightship condition and vertical center of gravity (VCG). It additionally increases fire hazards from unapproved gasoline machinery and constitutes improperly secured equipment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2026
Resolution: Portable generator was removed from the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2026
No resolution recorded
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] decay was identified at the upper terminus of the starboard transverse frame IWO aft portion of the starboard water tank, where it meets the deck beam and clamp. Adjacent frames were intact without observed decay. The owner plans to complete extensive repairs/renewals at the next scheduled drydock for the frames and deck beams along the starboard side between the cabin to the bow, to match previous repairs completed for the remainder of the vessel.
Prior to commencing any structural work, the owner/operator must submit a written repair proposal to the cognizant OCMI for review and approval. The proposal must detail the full scope of the intended work, the repair methods and materials to be used. All repairs must be completed to the satisfaction of the attending marine inspector by the next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2028
Resolution: NLT next drydock
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 September 2025
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. MI observed wire terminal strip mounted to forward bulkhead in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 29 September 2025
Resolution: Operator moved the electrical connections to inside a junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 June 2024
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in spaces with a through-hull fitting below the deepest load waterline, machinery bilge spaces, bilge wells, shaft alley bilge, or other
spaces subject to flooding from sea water piping within the space. The vessel's forward high bilge level alarm was inoperable, and the midship high bilge level alarm's visual indicator did not illuminate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 6 September 2024
Resolution: Operator repaired alarm.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2024
Resolved
Waste receptacle must be constructed of non-combustible materials with no openings in the side or bottom. The waste receptacles on the vessel's passenger deck were found to be made of plastic.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 6 September 2024
Resolution: Operator removed plastic waste receptacles.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2024
Resolved
A vessel not required to have a power driven fire pump by 46 CFR 181.300 must have at least 3 2.5 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] of the vessel's three fire buckets was found to be missing a lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 6 September 2024
Resolution: Operator equiped fire bucket with lanyard.
01 - Certificates & Documentation › 013 - Documents › Fire safety operational booklet
Issued 20 June 2024
Resolved
The owner or operator must provide satisfactory evidence of the required servicing of fire extinguishers to the marine inspector. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted. At the time of inspection, the operator was not able to produce evidence of satisfactory servicing for fire extinguishers.
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
Resolution: Operator provided proof that the fire extinguisher was serviced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 September 2021
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Crew members were not included on the consortium. Members not included shall not perform duties onboard until registered in the consortium.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Demonstrated full compliance with drug testing requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: A positive shutoff valve is installed at the hull penetration. Vessel did not have installed shutoff valves.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 28 September 2021
Resolution: Installed new valves.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 September 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel did not have appropriate supplies which were not expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 28 September 2021
Resolution: Provided new first aid kit
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 September 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. There are 03 lifejackets with holes in them and thus not suitable for service.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 September 2020
Resolved 16 September 2020
Resolution: Replacement lifejackets were brought onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. There is an exposed wire creating an electrical hazard on the forward edge of the canopy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
Resolution: Confirmed the wire was correctly capped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. The 02 electrical outlets in the pilot house lack protective covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2020
Resolved 30 September 2020
Resolution: Confirmed outlet covers were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2020
Resolved
Electrical equipment exposed to the weather must be watertight. The stern light cover is broken and not watertight.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
Resolution: Confirmed stern cover was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2020
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. The temporary electrical cord utilized in the pilot house does not meet the subchapter J requirements.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
Resolution: The temporary extension cord was replaced.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 September 2020
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. There is not fuel shutoff valve marking.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
Resolution: Confirmed the signw as installed.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 September 2020
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel does not have records of completed training.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 16 September 2020
Resolved 16 September 2020
Resolution: Observed the completion of a man overboard exercise and documentation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2019
Resolved
Fire extinguishers in good condition and charged, but out of inspection date by two weeks. Inspection is scheduled for 2 days from date of COI inspection. Provide properly serviced fire extinguishers by 6/21/2019.
Action required: 705 - Other - as specified
Due 14 June 2019
Resolved 17 June 2019
Resolution: Provided documentation of fire extinguisher service.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 June 2019
Resolved
Charts not updated. Provide updated charts for operational area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 17 June 2019
Resolution: Provided updated electronic and paper charts for area of operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 8 June 2018
Resolved
CO2 Cylinders must be hydor tested every 12 years. Fixed CO2 was last hydro tested in 2005.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 27 June 2018
Resolution: Fixed CO2 Hydrostatically tested.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 June 2018
Resolved
Make engine compartment gas tight to ensure effectiveness of fixed CO2. Temp arrangements are authorized for 2 weeks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 27 June 2018
Resolution: New vent closures were fabricated and installed in aft engine bulkhead making the enginroom gas tight.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 June 2018
Resolved
Make collision blkd water tight. There is a 2”x3” opening on the port side, top of blkd
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 27 June 2018
Resolution: The hole present in the collision bulkhead has been sealed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 June 2018
Resolved
Conduct annual service of 01 B-II portable fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 27 June 2018
Resolution: Portable B-II fire extigusisher has been serviced.
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 May 2017
Resolved
Reattach and label remote fuel shutoff.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2017
Resolved 15 June 2017
Resolution: Verified installation and operation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 May 2017
Resolved
Replace floating waterlight, restricted to daytime operations.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: New water light installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2017
Resolved
Masthead is inoperable, replace.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: Mast head light tested sat.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 May 2017
Resolved
Provide 60 feet of lifeline, dark in color or UV resistant.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: New line provided.
Documentation › Markings/Placards › Vessel Number (state)
Issued 24 May 2017
Resolved
Provide vessel name on port bow.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: Name on port bow.
Engineering › Bilge Water Management System › Not Installed
Issued 24 May 2017
Resolved
Provide 1 5 gpm hand bilge pump.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: hand bilge pump verified on board.
Fire Fighting › Fire Bucket › Quantity
Issued 24 May 2017
Resolved
Provide 3 2.5 gallon fire buckets, labeled "FIRE BUCKET", with lanyard able to reach waterline.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: Fire buckets on board.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 May 2017
Resolved
Missing 01 Adult life jacket, provide 01 lifejacket. Vessel total persons on board restricted to 49.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: All life jackets provided.
Construction/Loadline › Hull › Bottom Plating
Issued 25 May 2016
Resolved
Stbd quater bottom planking leaking from pin hole.
Due 8 June 2016
Resolved 10 June 2016
Resolution: Pin hole was sealed using a product called slik seal.
Engineering › Fuel Oil Service System › Hose
Issued 25 May 2016
Resolved
Fuel fill missing bonding in hose section. Install bonding strap.
Due 8 June 2016
Resolved 10 June 2016
Resolution: Bonding strap was added.
Construction/Loadline › Penetrations › Valve Flange
Issued 25 May 2016
Resolved
Provide cap for through hull fitting in fwd void centerline.
Due 8 June 2016
Resolved 10 June 2016
Resolution: Through hull fitting was capped.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 April 2016
Resolved
Vessel to complete annual inspection prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2016
Resolved 25 May 2016
Resolution: Completed annual inspection.
Operations/Management › Vessel Activity › Underway
Issued 18 April 2016
Resolved
Vessel to conduct underway sea trial in presence of marine inspector to verify watertight integrity following repairs to starboard side. Prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2016
Resolved 25 May 2016
Resolution: Completed underway trials to ensure watertight integrity of repairs.
Construction/Loadline › Hull › Transverse Frame
Issued 25 March 2016
Resolved
Due to extensive repairs identified during 2015 hull exam and subsequent repair proposals dated June 5, 2015 and March 9, 2016, vessel is required to follow and complete items listed on repair proposal dated March 9, 2016 prior to operating after October 31, 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 17 June 2019
Resolution: Item resolved prior to 2018 credit hull exam.