Records from 1985 to 2026. Most recent: inspection, 26 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 56
26 June 2026
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8417934
30 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8353266
16 September 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8235896
20 June 2024
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7927032
29 March 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7879039
9 June 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7668627
6 June 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7419655
31 March 2022
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7419637
13 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7311107
30 September 2020
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7098452
16 September 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7060001
31 March 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6933695
14 June 2019
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6713047
17 January 2018
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6436926
17 February 2017
Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6092509
25 March 2016
Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5847783
19 May 2014
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4859137
26 September 2011
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4155084
4 January 2010
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3658210
18 June 2008
In-Service Inspection · Simplified Stability Test · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3240392
12 May 2008
Hull Examination · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3205245
28 June 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2976228
3 October 2006
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2792433
1 June 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2666956
17 March 2006
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2603712
23 August 2005
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2472181
29 June 2004
Hull Examination · COI Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2114641
4 June 1999
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 810200
3 August 1998
Examination of Repairs · Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1130664
5 June 1998
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1386277
22 July 1997
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1424458
3 June 1996
Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1454342
14 August 1995
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1183157
13 June 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 876993
24 August 1994
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 149884
9 June 1994
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1332036
24 June 1993
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1155642
10 June 1993
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1154796
29 July 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 949428
11 July 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 149218
9 April 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1262837
5 November 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1264733
17 July 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1250193
27 December 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 921182
29 July 1990
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 931253
27 July 1990
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 907646
27 July 1990
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1244585
5 September 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 933382
11 August 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1236799
20 July 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 888543
29 June 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1208592
11 May 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1031494
8 September 1987
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1308152
3 June 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 988344
18 April 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1307170
3 June 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 980982
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2026
Resolved
Auxiliary machinery of the internal combustion piston type must comply with the provisions of this part. A portable gasoline generator was found stored unsecured above the passenger deck canopy. This unauthorized installation poses stability risks by altering the vessel's lightship condition and vertical center of gravity (VCG). It additionally increases fire hazards from unapproved gasoline machinery and constitutes improperly secured equipment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2026
Resolution: Portable generator was removed from the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2026
No resolution recorded
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] decay was identified at the upper terminus of the starboard transverse frame IWO aft portion of the starboard water tank, where it meets the deck beam and clamp. Adjacent frames were intact without observed decay. The owner plans to complete extensive repairs/renewals at the next scheduled drydock for the frames and deck beams along the starboard side between the cabin to the bow, to match previous repairs completed for the remainder of the vessel.
Prior to commencing any structural work, the owner/operator must submit a written repair proposal to the cognizant OCMI for review and approval. The proposal must detail the full scope of the intended work, the repair methods and materials to be used. All repairs must be completed to the satisfaction of the attending marine inspector by the next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2028
Resolution: NLT next drydock
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 September 2025
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. MI observed wire terminal strip mounted to forward bulkhead in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 29 September 2025
Resolution: Operator moved the electrical connections to inside a junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 June 2024
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in spaces with a through-hull fitting below the deepest load waterline, machinery bilge spaces, bilge wells, shaft alley bilge, or other
spaces subject to flooding from sea water piping within the space. The vessel's forward high bilge level alarm was inoperable, and the midship high bilge level alarm's visual indicator did not illuminate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 6 September 2024
Resolution: Operator repaired alarm.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2024
Resolved
Waste receptacle must be constructed of non-combustible materials with no openings in the side or bottom. The waste receptacles on the vessel's passenger deck were found to be made of plastic.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 6 September 2024
Resolution: Operator removed plastic waste receptacles.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2024
Resolved
A vessel not required to have a power driven fire pump by 46 CFR 181.300 must have at least 3 2.5 gallon buckets, with an attached lanyard satisfactory to the cognizant [name withheld] of the vessel's three fire buckets was found to be missing a lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 6 September 2024
Resolution: Operator equiped fire bucket with lanyard.
01 - Certificates & Documentation › 013 - Documents › Fire safety operational booklet
Issued 20 June 2024
Resolved
The owner or operator must provide satisfactory evidence of the required servicing of fire extinguishers to the marine inspector. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted. At the time of inspection, the operator was not able to produce evidence of satisfactory servicing for fire extinguishers.
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
Resolution: Operator provided proof that the fire extinguisher was serviced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 September 2021
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Crew members were not included on the consortium. Members not included shall not perform duties onboard until registered in the consortium.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 September 2021
Resolution: Demonstrated full compliance with drug testing requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: A positive shutoff valve is installed at the hull penetration. Vessel did not have installed shutoff valves.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 28 September 2021
Resolution: Installed new valves.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 September 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel did not have appropriate supplies which were not expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 28 September 2021
Resolution: Provided new first aid kit
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 September 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. There are 03 lifejackets with holes in them and thus not suitable for service.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 September 2020
Resolved 16 September 2020
Resolution: Replacement lifejackets were brought onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. There is an exposed wire creating an electrical hazard on the forward edge of the canopy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
Resolution: Confirmed the wire was correctly capped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. The 02 electrical outlets in the pilot house lack protective covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2020
Resolved 30 September 2020
Resolution: Confirmed outlet covers were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2020
Resolved
Electrical equipment exposed to the weather must be watertight. The stern light cover is broken and not watertight.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
Resolution: Confirmed stern cover was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2020
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. The temporary electrical cord utilized in the pilot house does not meet the subchapter J requirements.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
Resolution: The temporary extension cord was replaced.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 September 2020
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. There is not fuel shutoff valve marking.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
Resolution: Confirmed the signw as installed.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 September 2020
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel does not have records of completed training.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 16 September 2020
Resolved 16 September 2020
Resolution: Observed the completion of a man overboard exercise and documentation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2019
Resolved
Fire extinguishers in good condition and charged, but out of inspection date by two weeks. Inspection is scheduled for 2 days from date of COI inspection. Provide properly serviced fire extinguishers by 6/21/2019.
Action required: 705 - Other - as specified
Due 14 June 2019
Resolved 17 June 2019
Resolution: Provided documentation of fire extinguisher service.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 June 2019
Resolved
Charts not updated. Provide updated charts for operational area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 17 June 2019
Resolution: Provided updated electronic and paper charts for area of operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 8 June 2018
Resolved
CO2 Cylinders must be hydor tested every 12 years. Fixed CO2 was last hydro tested in 2005.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 27 June 2018
Resolution: Fixed CO2 Hydrostatically tested.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 June 2018
Resolved
Make engine compartment gas tight to ensure effectiveness of fixed CO2. Temp arrangements are authorized for 2 weeks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 27 June 2018
Resolution: New vent closures were fabricated and installed in aft engine bulkhead making the enginroom gas tight.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 June 2018
Resolved
Make collision blkd water tight. There is a 2”x3” opening on the port side, top of blkd
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 27 June 2018
Resolution: The hole present in the collision bulkhead has been sealed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 June 2018
Resolved
Conduct annual service of 01 B-II portable fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 27 June 2018
Resolution: Portable B-II fire extigusisher has been serviced.
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 May 2017
Resolved
Reattach and label remote fuel shutoff.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2017
Resolved 15 June 2017
Resolution: Verified installation and operation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 May 2017
Resolved
Replace floating waterlight, restricted to daytime operations.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: New water light installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2017
Resolved
Masthead is inoperable, replace.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: Mast head light tested sat.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 May 2017
Resolved
Provide 60 feet of lifeline, dark in color or UV resistant.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: New line provided.
Documentation › Markings/Placards › Vessel Number (state)
Issued 24 May 2017
Resolved
Provide vessel name on port bow.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: Name on port bow.
Engineering › Bilge Water Management System › Not Installed
Issued 24 May 2017
Resolved
Provide 1 5 gpm hand bilge pump.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: hand bilge pump verified on board.
Fire Fighting › Fire Bucket › Quantity
Issued 24 May 2017
Resolved
Provide 3 2.5 gallon fire buckets, labeled "FIRE BUCKET", with lanyard able to reach waterline.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: Fire buckets on board.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 May 2017
Resolved
Missing 01 Adult life jacket, provide 01 lifejacket. Vessel total persons on board restricted to 49.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 15 June 2017
Resolution: All life jackets provided.
Construction/Loadline › Hull › Bottom Plating
Issued 25 May 2016
Resolved
Stbd quater bottom planking leaking from pin hole.
Due 8 June 2016
Resolved 10 June 2016
Resolution: Pin hole was sealed using a product called slik seal.
Engineering › Fuel Oil Service System › Hose
Issued 25 May 2016
Resolved
Fuel fill missing bonding in hose section. Install bonding strap.
Due 8 June 2016
Resolved 10 June 2016
Resolution: Bonding strap was added.
Construction/Loadline › Penetrations › Valve Flange
Issued 25 May 2016
Resolved
Provide cap for through hull fitting in fwd void centerline.
Due 8 June 2016
Resolved 10 June 2016
Resolution: Through hull fitting was capped.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 April 2016
Resolved
Vessel to complete annual inspection prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2016
Resolved 25 May 2016
Resolution: Completed annual inspection.
Operations/Management › Vessel Activity › Underway
Issued 18 April 2016
Resolved
Vessel to conduct underway sea trial in presence of marine inspector to verify watertight integrity following repairs to starboard side. Prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2016
Resolved 25 May 2016
Resolution: Completed underway trials to ensure watertight integrity of repairs.
Construction/Loadline › Hull › Transverse Frame
Issued 25 March 2016
Resolved
Due to extensive repairs identified during 2015 hull exam and subsequent repair proposals dated June 5, 2015 and March 9, 2016, vessel is required to follow and complete items listed on repair proposal dated March 9, 2016 prior to operating after October 31, 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 17 June 2019
Resolution: Item resolved prior to 2018 credit hull exam.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 May 2014
Resolved
not onboard
Action required: 705 - Other - as specified
Due 2 June 2014
Resolved 29 May 2014
Resolution: Attended VSL to see new COD onboard, cleared 01 835 for no copy of COD onboard.
Communications › Radio Communications › EPIRB
Issued 18 June 2008
Resolved
Renew hydrostatic release.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 16 July 2008
Resolution: Corrected
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 18 June 2008
Resolved
Provide valid FCC radio operators permit. Vessel reduced to 1000 feet from shore.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 30 June 2008
Resolution: Corrected
Lifesaving › Lifefloat › Painter
Issued 18 June 2008
Resolved
Cotton line used between painter and float. Properly arrange life float lines IAW 46 CFR 180.130.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 30 June 2008
Resolution: Corrected
Lifesaving › Lifefloat › Markings
Issued 18 June 2008
Resolved
Properly mark paddles with vsl name.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 30 June 2008
Resolution: Corrected
Construction/Loadline › Hull › Side Shell
Issued 18 June 2008
Resolved
Properly repair wet seam at plank located portside, aft 2 feet, first above chine log.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 30 June 2008
Resolution: Corrected
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 28 June 2007
Resolved
review guidance for cooking systems for propane and repair accordingly
Due 12 July 2007
Resolved 1 August 2007
Resolution: Complete.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 June 2007
Resolved
replace keeer chains on all water tight hatches.
Due 12 July 2007
Resolved 15 July 2007
Resolution: Keeper chains repalced sat.
Lifesaving › Hand Flares › Storage
Issued 28 June 2007
Resolved
Place signal flares in water tight storage container.
Due 12 July 2007
Resolved 1 August 2007
Resolution: Storage provided sat.
Documentation › Certificates/Documents › FCC SSL
Issued 1 June 2006
Resolved
Provide FCC operators permit.
Due 26 June 2006
Resolved 9 June 2006
Resolution: provided same.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 1 June 2006
Resolved
Provide proof of enrollment in drug and alcohol testing program.
Due 26 June 2006
Resolved 9 June 2006
Resolution: The Maritme Consortiom provided for all drug and alcohol testing.
Lifesaving › Hand Flares › Quantity
Issued 1 June 2006
Resolved
provide adequate amount of flares for route. 3 more day 3 more night time flares.
Due 26 June 2006
Resolved 9 June 2006
Resolution: additional flares provided sat.
Communications › Radio Communications › EPIRB
Issued 1 June 2006
Resolved
Register EPIRB.
Due 26 June 2006
Resolved 9 June 2006
Resolution: EPIRB Registered with NOAA sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 June 2006
Resolved
Label all life jacket storage boxes.
Due 26 June 2006
Resolved 9 June 2006
Resolution: All boxes labled sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 August 2005
Resolved
MAINTAIN RECORDS OF EMERGENCY DRILLS AND LIFESAVING EQUIPMENT CHECKS
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 1 September 2005
Resolution: DRILL/LIFESAVING EQUIPMENT CHECKS LOGGED
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 23 August 2005
Resolved
PROVIDE CURRENT CPR/1ST AID CERTIFICATION FOR 50% OF CREW
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 1 September 2005
Resolution: CPR/1ST AID CERTIFICATION PROVIDED
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 23 August 2005
Resolved
PROVIDE FIRE FIGHTING EQUIPMENT SERVICE RECORDS
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 1 September 2005
Resolution: FIRE FIGHTING SERVICE RECORDS PROVIDED
Lifesaving › Lifefloat › Float-free Link
Issued 23 August 2005
Resolved
PROPERLY RIG LIFEFLOATS TO WEAK LINKS
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 1 September 2005
Resolution: WEAK LINKS RIGGED PROPERLY
Construction/Loadline
Issued 3 August 1998
Resolved
REPAIR FWD DECK HATCH DOGS.
Condition: Unknown
Due 13 August 1998
Resolved 19 August 1998
Deck/Cargo
Issued 3 August 1998
Resolved
RIG ANCHOR SO IT IS READY TO LET GO.
Condition: Unknown
Due 13 August 1998
Resolved 19 August 1998
Engineering
Issued 3 August 1998
Resolved
RENEW ROTTED KEEL COOLER HOSE.
Condition: Unknown
Due 13 August 1998
Resolved 19 August 1998
Engineering
Issued 3 August 1998
Resolved
REPAIR CONNECTION FOR MDE TEMPERATURE SENSOR.
Condition: Unknown
Due 13 August 1998
Resolved 19 August 1998
Lifesaving
Issued 3 August 1998
Resolved
RENEW ROTTED BA 100' PAINTER AND TAG LINES.
Condition: Unknown
Due 13 August 1998
Resolved 19 August 1998
Fire Fighting
Issued 3 August 1998
Resolved
WEIGH FIRE EXTINGUISHERS.
Condition: Unknown
Due 13 August 1998
Resolved 19 August 1998
Construction/Loadline
Issued 3 August 1998
Resolved
CAULK LEAK AT DEADWOOD 4FT FWD OF LAZARETTE HATCH PORT AND STBD SIDES.
Condition: Unknown
Due 13 August 1998
Resolved 4 September 1998
Navigation
Issued 3 August 1998
Resolved
REPAIR RUDDER WHILE HAULED. MAKE ALL REPAIRS BEFORE CARRYING PASSENGERS.
Condition: Unknown
Due 13 August 1998
Resolved 19 August 1998
Navigation
Issued 22 July 1997
Resolved
REPOSITION STERN LIGHT TO PROVIDE UNOBSTRUCTED VISIBILITY.
Condition: Unknown
Due 5 August 1997
Resolved 8 August 1997
Lifesaving
Issued 22 July 1997
Resolved
STOW CHILDREN'S PFDs SEPARATELY FROM ADULTS, AND LABEL LOCATION.
Condition: Unknown
Due 5 August 1997
Resolved 8 August 1997
Lifesaving
Issued 22 July 1997
Resolved
PROVIDE BRIGHTLY COLORED, WATERTIGHT CONTAINER FOR FLARES, STENCILED TO INDICATE CONTENTS.
Condition: Unknown
Due 5 August 1997
Resolved 8 August 1997
Navigation
Issued 22 July 1997
Resolved
PROVIDE UPDATED CHARTS (W/CORRECTIONS [NOTICE TO MARINERS]) AND CURRENT NAVIGATION RULES.
Condition: Unknown
Due 5 August 1997
Resolved 8 August 1997
Documentation
Issued 22 July 1997
Resolved
REGISTER EPIRB WITH NOAA/NESDIS, AND INSTALL IN FLOAT-FREE LOCATION.
Condition: Unknown
Due 5 August 1997
Resolved 8 August 1997
Engineering
Issued 22 July 1997
Resolved
REPLACE FLAME IMPINGEMENT BOWL ON DIESEL FUEL FILTER.
Condition: Unknown
Due 5 August 1997
Resolved 8 August 1997
Lifesaving
Issued 22 July 1997
Resolved
PROVIDE 3'-6' LANYARD AND SNAP HOOK ARRANGEMENT FOR WATERLIGHT CONNECTION TO RING BUOY.
Condition: Unknown
Due 5 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 3 June 1996
Resolved
PROVE PROPER OPERATION OF BOTH THE FORE AND AFT WATERTIGHT DECK HATCHES.
Condition: Unknown
Due 10 June 1996
Resolved 17 June 1996
Electrical
Issued 3 June 1996
Resolved
PROPERLY SECURE WIRING HARNESS IN THE ENGINE COMPARTMENT AND REMOVE ALL WIRENUTS. PROVIDE PROPER WIRE CONNECTIONS.
Condition: Unknown
Due 10 June 1996
Resolved 17 June 1996
Lifesaving
Issued 3 June 1996
Resolved
PROVIDE VESSEL WITH A USCG APPROVED 24" RING BUOY, ORANGE IN COLOR.
Condition: Unknown
Due 10 June 1996
Resolved 17 June 1996
Documentation
Issued 3 June 1996
Resolved
PROVIDE DOCUMENTATION SHOWING FULL COMPLIANCE WITH THE CHEMICAL TESTING REGULATIONS OF 46 CFR PART 16.
Condition: Unknown
Due 10 June 1996
Resolved 17 June 1996
Lifesaving
Issued 13 June 1995
Resolved
LIFE RING BUOY LIGHT NOT OPERATING. REQUIRES REPLACEMENT OR FIXING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Lifesaving
Issued 13 June 1995
Resolved
EPIRB ONBOARD BUT NOT REQUIRED. VESSEL MUST STOW EPIRB PROPERLY OR REMOVE FROM VESSEL. EPIRB IS NOT STOWED FOR FLOAT FREE, IF VESSEL SINKS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Lifesaving
Issued 13 June 1995
Resolved
TWO ADULT PFD'S REQUIRE VESSEL NAME STENCIL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 15 June 1995
Lifesaving
Issued 13 June 1995
Resolved
MISSING THREE NIGHT TIME FLARES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1995
Resolved 15 June 1995
Construction/Loadline
Issued 13 June 1995
Resolved
REPAIR THREE DECK SUPPORTS UNDER MAIN DECK AFT OF COLISION BULKHEAD THAT HAVE WORKED LOOSE. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Engineering
Issued 13 June 1995
Resolved
REMOVE PET COCK ON FUEL FILTER AND REPLACE WITH PLUG._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Construction/Loadline
Issued 13 June 1995
Resolved
REMOVE ALL CHANNELS HOLDING COVERS TO THE FREEING PORTS, AND REMOVE COVERS TO ALLOW FREEPORTS TO FUNCTION AS DESIGNED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Documentation
Issued 13 June 1995
Resolved
FCC SAFETY CERTIFICATE EXPIRED, REQUIRES RENEWAL_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Documentation
Issued 10 June 1993
Resolved
PROVIDE DOCUMENTATION ON CHEMICAL TESTING AS REQUIRED BY 46 CFR PART 16.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 10 June 1993
Resolved
CONDUCT UNDERWAY LIFESAVING DRILL IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Engineering
Issued 5 November 1991
Resolved
TAILSHAFT SNAPPED INWAY OF KEYWAY. RENEW TAILSHAFT AND PROPELLER PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Construction/Loadline
Issued 27 July 1990
Resolved
DOGS SEIZED ON LAZARATTE AND FOREPEAK MAN HOLE COVERS. FREE DOGS AND PROVEPROPER OPERATION PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Lifesaving
Issued 27 July 1990
Resolved
BOUYANT APPARATUS MARKED WITH PREVIOUS VESSEL NAME. MARK CURRENT VESSEL NAME ON BOUYANT APPARATUS, IN ACCORDANCE WITH 46CFR 185.30-5.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Electrical
Issued 27 July 1990
Resolved
MASTHEAD LITE WIRING NOT IN COMPLIANCE WITH 46 CFR 183.05-50. REMOVE WIRE NUTSAND BRING INTO COMPLIANCE WITH REGULATION.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Documentation
Issued 27 July 1990
Resolved
PROVIDE VALID FCC STATION AND SAFETY CERTIFICATE.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Lifesaving
Issued 20 July 1989
Resolved
LIFELINE, PENDANTS, WATERLIGHT, AND LANYARD MISSING FROM BOUYANT APPARATUS.PROVIDE LIFELINE AROUND THE OUTSIDE, PROVIDE PENDANTS FITTED 18 IN. APART 12 FT LONG SECURED IN THE MIDDLE 46CFR180.15-5
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Lifesaving
Issued 20 July 1989
Resolved
RING BOUY MISSING WATER LITE. PROVIDE WATERLITE FOR RING BOUY. 46CFR180.30-10
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Navigation
Issued 20 July 1989
Resolved
SINGLE SCREW VESSEL IN OCEAN AND COASTWISE SERVICE DOES NOT HAVE AUXILIARY STEERING ARRANGEMENT. PROVIDE TILLER OR OTHER SUITABLE AUXILIARY STEERING ARRANGEMENT.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Construction/Loadline
Issued 20 July 1989
Resolved
FOREPEAK HATCH COVER CAPTIVE CHAIN NOT ATTACHED TO COVER. SECURE CAPTIVE CHAIN TO HATCH COVER. 46CFR171.124
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Fire Fighting
Issued 20 July 1989
Resolved
VESSEL MISSING TWO B-II FIRE EXTINGUISHER. PROVIDE TWO USCG APPROVED FIRE EXTINGUISHERS FOR A TOTAL OF ONE B-1 AND TWO B-11. 46CFR181.30-1(A)
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Engineering
Issued 20 July 1989
Resolved
BATTERIES NOT CONTAINED IN BATTERY TRAY NOR PROPERLY SECURED. PROVIDE TRAY OF LEAD OR OTHER SUITABLE MATERIAL RESISTANT TO ACID, AND PROPERLY SECRE YHE TRAY. 46CFR183.05-20
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Unknown
Issued 20 July 1989
Resolved
PROPERLY SECURE BILGE PUMPS AND BRING BILGE SYSTEM INTO COMPLIANCE WITH COPY OF REGULATION PROVIDED.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Engineering
Issued 20 July 1989
Resolved
RACOR FUEL FILTER WITH LEXON BOWL MISSING HEAT SHIELD. PROVIDE HEAT SHIELDOR PROVIDE METAL BOWL FOR FILTER. 46CFR182.20-40
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989