Records from 2004 to 2025. Most recent: inspection, 18 September 2025.
Inspection history · 21
18 September 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8237009
3 October 2024
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7979932
3 September 2024
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7995700
31 August 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7781456
10 August 2022
Deadweight Survey · Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7542034
4 August 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7524290
13 April 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7430635
23 March 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7416946
23 December 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7395086
31 August 2021
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7300811
13 May 2021
Deficiency Check · Plan Review "T" Boat · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7194875
15 September 2020
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7058179
2 March 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6926275
22 November 2019
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6862524
11 October 2019
Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6832966
24 September 2019
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6820907
21 November 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6585163
19 November 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6583855
8 November 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6304774
10 October 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6285210
12 September 2016
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5999139
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 August 2022
Resolved
Each vessel must be equipped with portable lights at the operating station and each machinery space. Portable lights missing. Provide portable lights.
46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 22 December 2022
Resolution: The required portable lights were provided.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 August 2022
Resolved
A vessel must be fitted with a radar if it carries more than 49 passengers. Vessel does not have a radar. Provide an operational radar.
46 CFR 184.404
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 14 October 2022
Resolution: Regulation cited not applicable per OCMI, using 46 CFR 184.115.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 August 2022
Resolved
A vessel shall have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, man overboard, and abandon ship. Emergency instructions not posted. Post emergency instructions.
46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 22 December 2022
Resolution: Emergency instructions were posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 August 2022
Resolved
Each life jacket and ring buoy shall have working retro reflective material. 01 life jacket and ring buoy have wasted retro tape. Provide working retro tape.
46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 10 August 2022
Resolution: Ring and life jacket provided with new retro tape.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 August 2022
Resolved
Each life float must be secured to the vessel by a painter with a float-free link (weak Link) permanently attached to the vessel. Weak link shall be correct for the size of the life float. Current weak link does not have tag. Provide proper weak link.
46 CFR 180.130
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 10 August 2022
Resolution: New weak link provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 August 2022
Resolved
Hatch cover must have a captive chain. Aft hatch missing captive chain. Provide captive chain.
46 CFR 179.360(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 22 December 2022
Resolution: All hatch covers were provided with captive chains.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2022
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Starboard side hydraulic fittings corroded. Provide new fittings.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 22 December 2022
Resolution: All steering hose and fittings were renewed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 August 2022
Resolved
All vessels must have navigation lights that are in compliance with the navigation rules. Stern light is obstructed by piping. Raise stern light to prevent obstruction.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 22 December 2022
Resolution: The stern light was mounted in a postition that did not obstruct the visibility of the light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2022
Resolved
Piping used in a vital system must be composed of ferrous materials. Currently hose being used from fuel tank to engine room through bulkheads. Provide hard piped fuel system to engine room.
46 CFR 182.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 22 December 2022
Resolution: Fuel piping was provided with metallic fittings penetrating the watertight bulkheads.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 August 2022
Resolved
Boundaries that separate machinery space from accommodation space must be lined with noncombustible panels or approved insulation. Engine room ceiling was missing approved insulation. Provide panels or approved insulation.
46 CFR 177.4109(c)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2022
Resolved 14 October 2022
Resolution: Vessel is "Old T" and had not undergone a major modification, regulation cited is not applicable. Regulations in effect at the time do not require non-combustible insulation.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 13 April 2022
Resolved
In accordance with Marine Safety Center letter H1-2200695 Stability and Lightship Characteristics - Weight Changes dated March 25, 2022, the vessel must undergo a deadweight survey or new stability test NO LATER THAN next dry dock due date (May 31, 2023).
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 22 December 2022
Resolution: A deadweight survey was conducted and witnessed by a CG Marine Inspector.
14 - Pollution Prevention › 145 - MARPOL Annex V › Other (MARPOL Annex V)
Issued 31 August 2021
Resolved
(02) sewage valves were missing lock. Secure both overboard sewage valves in accordance with regulations. (i.e. closing each valve leading to an overboard discharge and removing the handle; padlocking each valve leading to an overboard discharge in the closed position; or using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 31 August 2021
Resolution: Vessel crew installed locks on port/stbd sewage valves prior to completion of inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2021
Resolved
Alcohol testing devices must be used according to the procedures specified by the manufacturer of the testing device and by this part. Obtain documentation for Alcosensor Breathalyzer to confirm calibration requirements in accordance with manufacturer specifications.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 22 September 2021
Resolution: Provided proof of Alcohol Test Strips onboard vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 31 August 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date nautical publications. US Coast Pilot/Light List was out of date. Recommend downloading or printing from Google latest edition (53rd/2021 edition).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 14 September 2021
Resolution: Pubs provided.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 May 2021
Resolved
Starboard side Laz hatch frame rotted. Replace hatch frame.
Drydock Worklist Item - Complete prior to splashing.
Action required: 705 - Other - as specified
Resolved 17 May 2021
Resolution: Frame replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 May 2021
Resolved
Port side mid space frame hatch rotted on upper aft portion. Replace rotted area.
Drydock Worklist Item - Complete prior to splashing.
Action required: 705 - Other - as specified
Resolved 17 May 2021
Resolution: Frame replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 September 2020
Resolved
Pre-engineered fire extinguishing system must have an audible alarm upon discharge in accordance with 46 CFR 181.420. Pre-engineered fire extinguishing system audible alarm failed. Install audible alarm for fireboy system at the operating station.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2020
Resolved 19 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 September 2020
Resolved
A vessel must be equipped with operating bilge pumps in accordance with 182.520. The bilge pumps failed to operate in port bow, starboard #4 void, and starboard #5 lazarette space. Owner must repair auto/manual switch for bilge pumps in the port bow, starboard #4 void and starboard #5 lazarette spaces.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2020
Resolved 19 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 September 2020
Resolved
A visual and audible indicator must be provided at operating station to indicate a high water level in accordance with 46 CFR 182.530. Starboard void #4 space did not have a working visual indicator and Starboard Lazarette #5 space did not have a working visual or audible indicator at the operating station. Owner must repair high water level alarm audible and visual indicators for the aforementioned spaces at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2020
Resolved 19 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended in accordance with 46 CFR 182.100. Low oil pressure alarm on the starboard side engine did not alarm. Owner must repair low oil pressure alarm on starboard side propulsion engine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 19 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 November 2019
Resolved
Provide 25gpm engine driven bilge pumps in port and stbd engine compartments per approved drawings on file in accordance with 46 CFR 176.500. Due by completion of 2021 drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 June 2021
Resolution: New 25GPM bilge pump and piping installed. New plans submitted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2019
Resolved
Stbd engine was vibrating excessively and made metallic noise while mooring after sea trial. Prove correct operation of engine in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2019
Resolution: Attended vessel. Chris stated idle screw was not adjusted correctly. Engine ran smoothly in forward/reverse and metallic noise was not present.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 November 2018
Resolved
Lifefloat was in unsatisfactory condition in accordance with 46 CFR 176.808. Renew lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 November 2018
Resolution: Lifefloat renewed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 September 2016
Resolved
6 adult lifejackets were not in serviceable condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2016
Resolution: Vessel replaced lifejackets with new ones.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2016
Resolved
Stern light was cover was worn and couldn't meet required standards.
Due 21 September 2016
Resolved 15 September 2016
Resolution: Vessel replaced stern light with new one.