AGGRESSOR

AGGRESSOR is a 1978 passenger vessel (inspected). The Coast Guard has recorded 93 inspections since 1986, most recently in April 2026, along with 92 deficiencies, 4 operational controls and 1 casualty investigation in 2023.

Records from 1986 to 2026. Most recent: inspection, 27 April 2026.

Built
1978
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB4379
Flag
UNITED STATES
366897770
Maury page id
psix-49656

Inspections, by type

…with no type recorded11
Years with a record 37 calendar years (1986–2026)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)57.4 ft × 15.1 ft × 6.1 ft
Registered tonnagegross 38 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB4379MMSI 366897770 · active · compulsorily equipped · granted 11 April 2023, expires 13 June 2033
WCW9783MMSI not assigned · expired · compulsorily equipped · granted 17 December 1996, cancelled 17 February 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 93

27 April 2026 Annual Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8328108
5 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8080940
6 February 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8036544
14 December 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8046346
5 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7892080
20 October 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7809485
16 August 2023 Appeal · Special Consideration
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7813763
10 August 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7825432
13 April 2023 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7659986
30 March 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654625
23 February 2023 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7601395
18 November 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613902
4 November 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7580607
28 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7439929
27 October 2021 Deficiency Check · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7332986
29 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7185132
25 February 2021 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7145851
25 January 2021 Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7131439
16 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6923512
16 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6874750
7 October 2019 In-Service Inspection · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6829937
1 July 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6661447
9 January 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6604910
23 April 2018 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6417310
9 April 2018 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6367600
9 May 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129160
25 January 2017 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5999232
26 May 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5869290
29 May 2012 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4293528
2 December 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3898373
12 May 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3472447
5 November 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3344382
15 April 2008 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3156922
13 July 2007 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2993842
2 May 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2989498
1 May 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2606162
2 June 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2384234
3 May 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2337772
14 October 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2221001
10 May 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2059989
29 April 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2055201
22 March 2004 Drydock Extension · Internal Structural Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2026276
16 March 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2025730
28 April 2003 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1779374
7 May 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1613529
9 April 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1602951
6 March 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1491343
30 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 772599
27 February 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1062324
27 February 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1397586
18 August 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1449364
25 April 2000 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1048510
3 April 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1369602
18 February 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378961
26 January 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 814553
6 April 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 787585
29 March 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 779960
1 March 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 799717
22 January 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 804767
2 March 1998 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 774294
16 December 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1117576
19 July 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 63237
11 July 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1117022
24 June 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 777682
16 April 1997 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1104381
24 March 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1106496
8 October 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1360643
13 June 1996 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1446370
12 October 1995 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1446264
20 September 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1183628
13 September 1994 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1465168
14 October 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1470653
25 March 1993 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1428195
14 October 1992 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1253387
31 October 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 933183
10 October 1991 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 932236
10 October 1991 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1254241
22 May 1991 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 910435
21 March 1991 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 929810
18 April 1990 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 929569
2 April 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1220553
20 February 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 929825
29 January 1990 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1226039
25 January 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1225699
9 May 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1201523
24 April 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1044935
10 April 1989 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1034222
11 February 1988 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1334425
9 June 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1017332
6 April 1987 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1003854
25 March 1987 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1331174
2 July 1986 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1306701
27 March 1986 Credit Drydock · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 998800

Deficiency record · 92

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 April 2026 Resolved
A power-driven vessel underway shall exhibit: a sternlight. Marine Inspector (MI) observed the sternlight was inoperable. Vessel is restricted to operations from sunrise to sunset with no restricted visibility.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2026
Resolved 29 April 2026
Resolution: Proper operation witnessed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 April 2026 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. MI observed EPIRB battery was expired. Vessel restricted to operations within 3 miles from the coastline.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2026
Resolved 29 April 2026
Resolution: New EPIRB registered and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 April 2026 Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. MI observed the paddles weren't lashed to the life floats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2026
Resolved 29 April 2026
Resolution: Paddles secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2026 Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI observed the vessel only had 48 adult life jackets. Vessel is restricted to carry 48 total persons.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2026
Resolved 29 April 2026
Resolution: Two new PFD placed into service.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2025 Resolved
A suitable marine type strainer shall be fitted in the fuel supply line in the engine compartment. The installed 'Racor' fuel filter for the port main engine has a plastic drain valve at the bottom. 46 CFR 182.20-40(B)(5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 5 May 2025
Resolution: Received photos of metal drain plug installed on fuel filter.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 June 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The 22 person and 6 person life floats are cracked and must be repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 17 June 2024
Resolution: Replaced 22 person life float and satisfactorily repaired the 6 person life float (see pictures).
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 June 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The ring life buoy is cracked and must be repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 17 June 2024
Resolution: Replaced ring buoy with new buoy (see pictures).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2022 Resolved
46 CFR 117.70; Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy..
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 19 January 2023
Resolution: Recieved picture of proper size lanyard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 October 2021 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in charge, Marine inspections, but not fewer than the minimum number required by Table 181.500(b) 02 fire extinguishers were found to require servicing and had pressure gauges in the red recharge zone. 46 CFR 176.810(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2021
Resolved 28 October 2021
Resolution: Vessel had extinguishers serviced, all satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. Electrical extension cord in engine room powered two additional lights. 46 CFR 183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2021
Resolved 28 October 2021
Resolution: Vessel crew removed extension cord from engine room and submitted plans to install additional electrical outlets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. Daisy chained electrical found in the galley, powering the freezer and coffee maker. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 October 2021
Resolved 27 October 2021
Resolution: Removed power stripe wired into outlet.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2021 Resolved
Each item of survival craft equipment must be good quality, and efficient for the purpose it is intended to serve. MI discovered lifelines on 01 life float to be completely wasted. Vessel to provide lifelines of adequate strength. Vessel restricted to 25 total persons.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 19 May 2021
Resolution: Found sat repair.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 April 2021 Resolved
Each item of survival craft equipment must be good quality, and efficient for the purpose it is intended to serve. MI discovered 01 paddles were split. Vessel to provide adequate paddles.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 19 May 2021
Resolution: Sighted new paddles.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 April 2021 Resolved
The discharge ends of fuel tank vent piptes must be fitted with removable flame screens of at least 30x30 mesh. Vessel missing flame screen on starboard side. Vessel to provide proper flame screen.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 19 May 2021
Resolution: Sighted correct flame screen installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 April 2021 Resolved
All escape hatches must be marked on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR." Marking on outside of escape hatch missing. Vessel to provide marking.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 19 May 2021
Resolution: Sighted correct markings.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 June 2020 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shutdown all power ventilation systems and all engines that draw intake air from within the space. Number 2 generator did not shutdown during Fireboy Testing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2020
Resolved 17 June 2020
Resolution: MI visually verfied proper shutdown of all engines when Fireboy suppression system is activated. ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 October 2019 Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape. Install adequate lighting in the vicinity of the FED emergency escape hatch. 46 CFR 184.30-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 15 November 2019
Resolution: Vessel installed emergency lighting.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 31 October 2019 Resolved
Master shall conduct drills and give instructions as necessary to ensure that all crewmembers are familiar with duties. Crew not available for drills. 46 CFR 185.25-10
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 15 November 2019
Resolution: Crew was available & conducted drills.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 31 October 2019 Resolved
Mattresses must comply with either 16 CFR 1632 or IMO Res. A.688(17). Mattresses onboard could not be verified for compliance. 46 CFR 177.405
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 16 June 2020
Resolution: MI Verified that all mattresses have been removed during annual inspection on 16JUN20. MISLE# 6923512.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 31 October 2019 Resolved
At each initial inspection and subsequent inspection for certification, the MI shall require that all observed unsafe practices or hazardous situations be corrected. Vessel is not authorized to carry passengers overnight until accomodations meet all appliciable standards/regulations. 46 CFR 176.25-50
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 15 November 2019
Resolution: Vessel authorized to carry 15 passengers overnight & 4 crew.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 July 2019 Resolved
SUITABLE COVERS, GUARDS, OR RAILS SHALL BE INSTALLED IN WAY OF ALL EXPOSED AND HAZARDOUS PLACES SUCH AS GEARS, MACHINERY, ETC. MI DISCOVERED EXPOSED ROTATING MACHINERY ON PORT MAIN ENGINE DUE TO REMOVAL OF PREVIOUSLY INSTALLED GUARD. PROVE PROPER REINSTALLATION. 46CFR 177.35-15(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 12 July 2019
Resolution: Deficiency rectified to satisfaction Coast Guard Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 July 2019 Resolved
EACH WATER TIGHT BULKHEAD MUST BE OF SUFFICIENT STRENGTH TO BE CAPABLE OF REMAINING WEATHERTIGHT WITH A HEAD OF WATER TO THE TOP OF THE BULKHEAD. MI DISCOVERED STUFFING TUBE IN LAZARETTE FORWARD BULKEAD UN-CAPPED / SEALED. PROVE WATERTIGHT. 46CFR 179.320(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 12 July 2019
Resolution: Deficiency rectified to satisfaction Coast Guard Marine Inspector.
Stability › Weathertight Integrity › General
Issued 9 April 2018 Resolved
Replace 03 passenger cabin windows on portside and 01 starbd head.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2018
Resolved 22 May 2018
Resolution: 03 port side cabin windows and 01 starboard side head window were replaced.
Engineering › Bilge Water Management System › Not Operational
Issued 9 April 2018 Resolved
Prove steering compartment bilge suction operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2018
Resolution: Crew resealed through bulhead penetration form ER to fish locker sealing up vacuum leak.
Fire Fighting › Fire Bucket › Availability
Issued 9 April 2018 Resolved
Provide required fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2018
Resolution: Buckets provided with labeling and lanyards.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 April 2018 Resolved
Provide flaoting light to both lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2018
Resolution: Floating light attached by lanyard to each life float.
Engineering › Sea-water System (primary cooling) › Valve
Issued 25 January 2017 Resolved
Replace port side main diesel engine valve (raw water).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 8 March 2017
Resolution: Port MDE raw water valve replaced with 2 1/2" ball valve.
Construction/Loadline › Structures › Deck Plating
Issued 25 January 2017 Resolved
Treat (superficial rot) overhead of fishhold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 8 March 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 May 2016 Resolved
Provide flame shield for port and STBD fuel shutoff valves as per 46CFR182.455(b)(4)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 26 May 2016
Resolution: Master added aluminum plate for shielding fuel shutoff valves
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 26 May 2016 Resolved
Provide closures for exhaust as per 46CFR182.465(h)
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 26 May 2016
Resolution: Master provided proper vent cover for engine exhaust
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 26 May 2016 Resolved
Replace wasted grounding wire connecting to valve in engine room as pointed out by marine inspector as per 46CFR183.372(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 26 May 2016
Resolution: Master reattached grounding wire to sea chest valve
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 May 2016 Resolved
Provide 04 adult PFD's as per 46CFR180.71(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 26 May 2016
Resolution: Vessel owner provided (04) new PFD's on the spot
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 November 2008 Resolved
Starboard main engine exhaust pipe missing insulation.
Due 5 November 2008
Resolved 5 November 2008
Resolution: Crew installed insulation on the spot to the satisfaction of the attending marine inspector.
Construction/Loadline › Hull › Hull Plating
Issued 5 November 2008 Resolved
Quarter-sized pit on exterior port-side lazarette bulkhead frame. Required crew to provide photo to the Coast Guard of the affected repair prior to painting the area.
Due 7 November 2008
Resolved 6 November 2008
Resolution: Ground out surrounding area around pit and affected fiberglass patch repair to the satisfaction of the attending marine inspector.
Stability › Weathertight Integrity › General
Issued 5 November 2008 Resolved
Missing bolt on aft deck starboard corner allows water to leak into lazarette. Replace bolt and ensure watertightness.
Due 5 November 2008
Resolved 5 November 2008
Resolution: Crew replaced bolt, on the spot correction.
Construction/Loadline › Structures › End Bulkhead
Issued 5 November 2008 Resolved
Missing bolts in bulkhead between lazarette and fish holding tank causing the tank not to be watertight. Replace bolts to ensure watertightness of bulkhead.
Due 5 November 2008
Resolved 5 November 2008
Resolution: Crew replaced the bolts in the bulkhead, on the spot correction.
Fire Fighting › Fire Bucket › Availability
Issued 13 July 2007 Resolved
Provide fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 13 July 2007
Resolution: Provided fire buckets
Lifesaving › Lifefloat › Lifeline
Issued 13 July 2007 Resolved
Provide lifelines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 13 July 2007
Resolution: Provided lifelines.
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 July 2007 Resolved
Make engine room hatch operable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 13 July 2007
Resolution: Engine room hatch operable.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 13 July 2007 Resolved
Provide a lock to sewage discharge valve prevent discharge o f sewage within 3 nautical miles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 13 July 2007
Resolution: Lock provided for sewage discharge valve.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 13 July 2007 Resolved
Provide operable batteries for PFD lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 13 July 2007
Resolution: Batteries provided for PFD lights
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 May 2007 Resolved
Provide cover for exposed curcuit board (for Fire Boy) located under helm console IAW 46CFR183.200(c) within 30 days to the satisfaction of attending USCG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 19 June 2007
Resolution: [name withheld] cleared 835.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 2 May 2007 Resolved
It was determined that the vessels arrangement is such that an unconscious person cannot be recovered from the water without additional equipment. Provide rescue boat or platform or other suitable arrangement IAW 46CFR180.210 within 30 days to the safisfaction of attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 19 June 2007
Resolution: Received digital photos of suitable arrangement. Def cleared. -Rendon
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 1 May 2006 Resolved
Ensure fixed firefighting system in the engine room is properly serviced and inspected as per 46 CFR 176.810 and provide completed servicing certificate to the attending Marine inspector. This requirements must be met prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 3 May 2006
Resolution: Fixed firefighting system was serviced and performed to the satisfaction of the attending Marine Inspector.
Engineering › Bilge Water Management System › Piping
Issued 3 May 2005 Resolved
Renew PVC (plastic) piping in all vital piping systems in way of the engine room.
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 2 June 2005
Resolution: Renewed piping in vital systems in way of the engine room.
Construction/Loadline › Structures › Trunk
Issued 10 May 2004 Resolved
Provide proper watertight trunk as per 46 CFR 179.360 (a) (1).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2004
Resolution: Increased truck height from 6" to 12" to meet watertight/weathertight standards.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 May 2004 Resolved
Provide proper collision bulkhead as per 46 CFR
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2004
Resolution: Repaired hole in collision bulkhead to the satisfaction of the attending Marine Inspector.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 March 2004 Resolved
Shafts have considerable leakage.
Due 31 March 2004
Resolved 30 March 2004
Construction/Loadline › Penetrations
Issued 22 March 2004 Resolved
Make bulkheads leading into berthing area watertight
Due 7 April 2004
Resolved 30 March 2004
Engineering
Issued 22 March 2004 Resolved
Starboard rudder post leaks
Due 31 March 2004
Resolved 30 March 2004
Documentation › Logs/Records
Issued 28 April 2003 Resolved
Provide current training log book and life saving equipment maintenance books. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Due 15 May 2003
Resolved 29 April 2004
Resolution: Provided training log book and life saving maintenance book w/in main log.
Electrical › Electrical Distribution System (service)
Issued 28 April 2003 Resolved
Provide "block out" on electrical panel. LEGACY COMPONENT DESC: Fuse
Condition: Unknown
Due 15 May 2003
Resolved 29 April 2004
Resolution: Provided block out on electrical panel.
Communications › Radio Communications
Issued 28 April 2003 Resolved
Provide new Hydrostatic release for the EPIRB. LEGACY COMPONENT DESC: EPIRB
Due 15 May 2003
Resolved 29 April 2004
Resolution: Found hydrostatic release on EPIRB to be within expiration date.
Engineering › Steering Gear System
Issued 28 April 2003 Resolved
Provide stop on steering gear pin. LEGACY COMPONENT DESC: Pin
Due 15 May 2003
Resolved 29 April 2004
Resolution: Provided steering gear pin stop.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 April 2002 Resolved
Provide smoke detection and alarm unit for passenger accomodations IAW 46 CFR 181.400. LEGACY COMPONENT DESC: Smoke Detection System
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2002
Resolution: Independent smoke detectors installed in galley & overnight accomodations area.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 April 2002 Resolved
Install public address system operable from operating station in overnight accomodation space IAW 184.610. LEGACY COMPONENT DESC: Public Address System
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2002
Resolution: Additional speaker installed in accom area, tested sat.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 April 2002 Resolved
Install emergency lighting in overnight accomodations IAW 46 CFR 184.30-5. LEGACY COMPONENT DESC: Emergency Lighting
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2002
Resolution: New e-lights tested sat in accom areas.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 10 April 2002 Resolved
Tie in generator to shutdown from engineroom fixed firefighting.
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 7 May 2002
Resolution: Tested generator & both MDE shutdown from fixed FF system sat.
Engineering › Bilge Water Management System
Issued 10 April 2002 Resolved
Install metallic shutoff valves for PVC piping piercing collision bulkhead IAW 46 CFR 182.40-1. LEGACY COMPONENT DESC: Piping
Due 31 March 2004
Resolved 7 May 2002
Resolution: Proper shutoff valves installed in bilge piping, just aft of collision bulkhead.
Electrical › Lighting (service)
Issued 10 April 2002 Resolved
Remove 110 Volt lighting in passenger accomodations and ensure all electrical installations are IAW 46 CFR 183.340. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 7 May 2002
Resolution: Ungrounded lights removed, and grounded fluorescent lights installed sat.
Electrical › Electrical Distribution System (service)
Issued 10 April 2002 Resolved
Remove dead end wiring in E/R. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 7 May 2002
Resolution: Removed sat.
Engineering › Fuel Oil Service System
Issued 10 April 2002 Resolved
Mark starboard remote fuel oil shutoff valve on main deck. LEGACY COMPONENT DESC: Remote Shutoff
Due 10 April 2002
Resolved 10 April 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 April 2002 Resolved
Put vessel name on two PFD's, not properly marked. LEGACY COMPONENT DESC: Marking
Due 10 April 2002
Resolved 10 April 2002
Documentation › Logs/Records
Issued 10 April 2002 Resolved
Maintain a written log of monthly EPIRB tests. LEGACY COMPONENT DESC: EPIRB Test Log
Due 10 April 2002
Resolved 10 April 2002
Stability › Watertight Integrity
Issued 10 April 2002 Resolved
Make E/R hatch watertight. LEGACY COMPONENT DESC: E/R Hatch
Due 10 April 2002
Resolved 10 April 2002
Resolution: Cleaned E/R hatch gasket.
Lifesaving › Lifebuoys
Issued 9 April 2002 Resolved
Fix or replace ring buoy waterlight. LEGACY COMPONENT DESC: Waterlight
Due 10 April 2002
Resolved 10 April 2002
Resolution: Waterlight was fixed.
Fire Fighting › Grease Extraction Hood
Issued 9 April 2002 Resolved
Submit plans to provide a Grease Extraction Hood for griddle in galley IAW 46 CFR 181.400(d) or for an equivalent level of safety acceptable to the Officer in Charge of Marine Inspection.
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 7 May 2002
Resolution: Maintenance log for grease extraction hood started; smoke detector installed in vicinity of hood; 2 B-II extinguishers very nearby. Sat.
Electrical › Electric Supply System (service)
Issued 6 March 2002 Resolved
Remove dead end wires below main console. LEGACY COMPONENT DESC: Cable
Due 6 March 2002
Resolved 6 March 2002
Resolution: Corrected on the spot.
Deck/Cargo › Mooring/Anchoring
Issued 6 March 2002 Resolved
Five feet anchor chain closest to anchor attachment point excessively worn. LEGACY COMPONENT DESC: Anchor Chain (general)
Due 6 March 2002
Resolved 6 March 2002
Resolution: Corrected on the spot.
Construction/Loadline › Structures
Issued 5 March 2002 Resolved
Stbd aft window broken in cabin. Replace window as original. LEGACY COMPONENT DESC: Superstructure
Due 5 March 2002
Resolved 5 March 2002
Resolution: O/O was in process of replacing window at time of examination. Corrected on the spot.
Construction/Loadline
Issued 26 January 2000 Resolved
VESSEL MUST BE SATISFACTORILY DRYDOCKED PRIOR TO THE CARRIAGE OF PASSENGERSFOR HIRE.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Fire Fighting
Issued 29 March 1999 Resolved
Submit plans for approval of fixed firefighting system. Upon approval of_x001C_ plans, complete installation of system and make available for inspection.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Engineering
Issued 2 March 1998 Resolved
INSTALL 30X30 MESH ON FUEL TANK VENTS
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Documentation
Issued 16 December 1997 Resolved
PRIOR TO THE CARRYING OF PASSENGERS, A COAST GUARD REINSPECTION IS TO BE CONDUCTED.
Condition: Unknown
Due 16 January 1998
Resolved 6 March 1998
Documentation
Issued 24 June 1997 Resolved
PROVIDE PROOF/COPY OF NEW VESSEL CERTIFICATE OF DOCUMENTATION REFLECTING NEW OWNERSHIP AND OPERATOR.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Lifesaving
Issued 24 March 1997 Resolved
CONDUCT MAN OVERBOARD DRILL IN THE PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Navigation
Issued 8 October 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE PROOF OF PURCHASE OF 3 ORANGE DISTRESS SIGNALS.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Lifesaving
Issued 8 October 1996 Resolved
CONDUCT MAN OVERBOARD DRILL IN THE PRESENCE OF MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Navigation
Issued 8 October 1996 Resolved
PAINT DISTRESS SIGNALS CONTAINER BRIGHT COLOR.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Navigation
Issued 8 October 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS REINSTALL AND PROVIDE PROOF OF SERVICINGOF EPIRB.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Construction/Loadline
Issued 13 September 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVE PROPER OPERATION OF ALL BILGE PUMPS.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Engineering
Issued 13 September 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVE PROPER OPERATION OF MAIN PROPULSION ENGINES.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Navigation
Issued 13 September 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF ALL RADIO EQUIPMENT.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Electrical
Issued 13 September 1994 Resolved
MAKE REPAIRS TO ALL INTERIOR LIGHTING AND PROVE PROPER OPERATION OF LIGHTS.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Engineering
Issued 10 October 1991 Resolved
ENCLOSE REMOTE FUEL LINE SHUTOFF VALVE HANDLES WITH FIRE RETARDANT PROTECTIVE HOUSINGS TO ISOLATE HANDLES FROM COMPARTMENT IN CASE OF ENGINEROOM FIRE/EMERGENCY.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Engineering
Issued 10 October 1991 Resolved
REPLACE FLEXIBLE HOSE FUEL LINES BETWEEN THE TWO PORT FUEL TANKS AND BETWEEN THE TWO STBD FUEL TANKS WITH COAST GUARD APPROVED FLEXIBLE HOSE FUEL LINES.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Engineering
Issued 10 October 1991 Resolved
EFFECTIVELY INSULATE EXHAUST PIPING BETWEEN ENGINE MANIFOLD AND POINT_x001C_ OF COOLING WATER INJECTION IN ACCORDANCE WITH 46 CFR 182.15-15(B)(3).
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Engineering
Issued 29 January 1990 Resolved
PRESENT VESSEL TO COAST GUARD INSPECTOR ONCE BACK IN WATER TO TEST MAIN ENGINES, EXHAUST COOLING SYSTEM AND FLOW ALARM, GENERATOR, AND NEW THRU HULL FITTINGS.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Fire Fighting
Issued 10 April 1989 Resolved
PROVIDE DOCUMENTATION VERIFYING THAT ALL PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS WERE HYDROSTATICALLY TESTED, OR REPLACE EXTINGUISHERS WITH NEW ONES.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Engineering
Issued 25 March 1987 Resolved
REPLACE RELIEF VALVES ON AIR RECEIVERS WITH VALVES WHICH RELIEVE BELOW THE MAWP OF THE PRESSURE VESSEL ON WHICH IT IS INSTALLED.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Lifesaving
Issued 25 March 1987 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE TWO PADDLES FOR THE WASTED LIFE FLOAT PADDLES.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.
Lifesaving
Issued 25 March 1987 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE A NEW LIFELINE FOR THE RING LIFE BUOY.
Condition: Unknown
Due 18 March 2002
Resolved 18 March 2002
Resolution: MISLE maintenance, cleared all outstanding requirements more than six months old.

Casualty record · 1

10 August 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7825432
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.