Records from 2016 to 2026. Most recent: inspection, 27 April 2026.
Inspection history · 28
27 April 2026
Annual Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8328108
5 May 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8080940
6 February 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8036544
14 December 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8046346
5 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7892080
20 October 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7809485
16 August 2023
Appeal · Special Consideration
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7813763
10 August 2023
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7825432
13 April 2023
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7659986
30 March 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654625
23 February 2023
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7601395
18 November 2022
Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613902
4 November 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7580607
28 April 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7439929
27 October 2021
Deficiency Check · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7332986
29 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7185132
25 February 2021
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7145851
25 January 2021
Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7131439
16 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6923512
16 December 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6874750
7 October 2019
In-Service Inspection · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6829937
1 July 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6661447
9 January 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6604910
23 April 2018
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6417310
9 April 2018
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6367600
9 May 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129160
25 January 2017
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5999232
26 May 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5869290
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 April 2026
Resolved
A power-driven vessel underway shall exhibit: a sternlight. Marine Inspector (MI) observed the sternlight was inoperable. Vessel is restricted to operations from sunrise to sunset with no restricted visibility.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2026
Resolved 29 April 2026
Resolution: Proper operation witnessed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 April 2026
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. MI observed EPIRB battery was expired. Vessel restricted to operations within 3 miles from the coastline.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2026
Resolved 29 April 2026
Resolution: New EPIRB registered and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 April 2026
Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. MI observed the paddles weren't lashed to the life floats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2026
Resolved 29 April 2026
Resolution: Paddles secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI observed the vessel only had 48 adult life jackets. Vessel is restricted to carry 48 total persons.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2026
Resolved 29 April 2026
Resolution: Two new PFD placed into service.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2025
Resolved
A suitable marine type strainer shall be fitted in the fuel supply line in the engine compartment. The installed 'Racor' fuel filter for the port main engine has a plastic drain valve at the bottom.
46 CFR 182.20-40(B)(5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 5 May 2025
Resolution: Received photos of metal drain plug installed on fuel filter.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 June 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The 22 person and 6 person life floats are cracked and must be repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 17 June 2024
Resolution: Replaced 22 person life float and satisfactorily repaired the 6 person life float (see pictures).
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 June 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The ring life buoy is cracked and must be repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 17 June 2024
Resolution: Replaced ring buoy with new buoy (see pictures).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2022
Resolved
46 CFR 117.70; Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy..
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 19 January 2023
Resolution: Recieved picture of proper size lanyard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 October 2021
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in charge, Marine inspections, but not fewer than the minimum number required by Table 181.500(b)
02 fire extinguishers were found to require servicing and had pressure gauges in the red recharge zone. 46 CFR 176.810(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2021
Resolved 28 October 2021
Resolution: Vessel had extinguishers serviced, all satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment.
Electrical extension cord in engine room powered two additional lights. 46 CFR 183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2021
Resolved 28 October 2021
Resolution: Vessel crew removed extension cord from engine room and submitted plans to install additional electrical outlets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment.
Daisy chained electrical found in the galley, powering the freezer and coffee maker. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 October 2021
Resolved 27 October 2021
Resolution: Removed power stripe wired into outlet.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 April 2021
Resolved
Each item of survival craft equipment must be good quality, and efficient for the purpose it is intended to serve. MI discovered lifelines on 01 life float to be completely wasted. Vessel to provide lifelines of adequate strength. Vessel restricted to 25 total persons.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 19 May 2021
Resolution: Found sat repair.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 April 2021
Resolved
Each item of survival craft equipment must be good quality, and efficient for the purpose it is intended to serve. MI discovered 01 paddles were split. Vessel to provide adequate paddles.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 19 May 2021
Resolution: Sighted new paddles.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 April 2021
Resolved
The discharge ends of fuel tank vent piptes must be fitted with removable flame screens of at least 30x30 mesh. Vessel missing flame screen on starboard side. Vessel to provide proper flame screen.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 19 May 2021
Resolution: Sighted correct flame screen installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 April 2021
Resolved
All escape hatches must be marked on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR." Marking on outside of escape hatch missing. Vessel to provide marking.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 19 May 2021
Resolution: Sighted correct markings.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 June 2020
Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shutdown all power ventilation systems and all engines that draw intake air from within the space.
Number 2 generator did not shutdown during Fireboy Testing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2020
Resolved 17 June 2020
Resolution: MI visually verfied proper shutdown of all engines when Fireboy suppression system is activated. ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 October 2019
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape. Install adequate lighting in the vicinity of the FED emergency escape hatch.
46 CFR 184.30-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 15 November 2019
Resolution: Vessel installed emergency lighting.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 31 October 2019
Resolved
Master shall conduct drills and give instructions as necessary to ensure that all crewmembers are familiar with duties. Crew not available for drills.
46 CFR 185.25-10
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 15 November 2019
Resolution: Crew was available & conducted drills.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 31 October 2019
Resolved
Mattresses must comply with either 16 CFR 1632 or IMO Res. A.688(17). Mattresses onboard could not be verified for compliance.
46 CFR 177.405
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 16 June 2020
Resolution: MI Verified that all mattresses have been removed during annual inspection on 16JUN20. MISLE# 6923512.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 31 October 2019
Resolved
At each initial inspection and subsequent inspection for certification, the MI shall require that all observed unsafe practices or hazardous situations be corrected. Vessel is not authorized to carry passengers overnight until accomodations meet all appliciable standards/regulations.
46 CFR 176.25-50
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 15 November 2019
Resolution: Vessel authorized to carry 15 passengers overnight & 4 crew.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 July 2019
Resolved
SUITABLE COVERS, GUARDS, OR RAILS SHALL BE INSTALLED IN WAY OF ALL EXPOSED AND HAZARDOUS PLACES SUCH AS GEARS, MACHINERY, ETC. MI DISCOVERED EXPOSED ROTATING MACHINERY ON PORT MAIN ENGINE DUE TO REMOVAL OF PREVIOUSLY INSTALLED GUARD. PROVE PROPER REINSTALLATION.
46CFR 177.35-15(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 12 July 2019
Resolution: Deficiency rectified to satisfaction Coast Guard Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 July 2019
Resolved
EACH WATER TIGHT BULKHEAD MUST BE OF SUFFICIENT STRENGTH TO BE CAPABLE OF REMAINING WEATHERTIGHT WITH A HEAD OF WATER TO THE TOP OF THE BULKHEAD. MI DISCOVERED STUFFING TUBE IN LAZARETTE FORWARD BULKEAD UN-CAPPED / SEALED. PROVE WATERTIGHT.
46CFR 179.320(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 12 July 2019
Resolution: Deficiency rectified to satisfaction Coast Guard Marine Inspector.
Stability › Weathertight Integrity › General
Issued 9 April 2018
Resolved
Replace 03 passenger cabin windows on portside and 01 starbd head.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2018
Resolved 22 May 2018
Resolution: 03 port side cabin windows and 01 starboard side head window were replaced.
Engineering › Bilge Water Management System › Not Operational
Issued 9 April 2018
Resolved
Prove steering compartment bilge suction operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2018
Resolution: Crew resealed through bulhead penetration form ER to fish locker sealing up vacuum leak.
Fire Fighting › Fire Bucket › Availability
Issued 9 April 2018
Resolved
Provide required fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2018
Resolution: Buckets provided with labeling and lanyards.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 April 2018
Resolved
Provide flaoting light to both lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2018
Resolution: Floating light attached by lanyard to each life float.
Engineering › Sea-water System (primary cooling) › Valve
Issued 25 January 2017
Resolved
Replace port side main diesel engine valve (raw water).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 8 March 2017
Resolution: Port MDE raw water valve replaced with 2 1/2" ball valve.
Construction/Loadline › Structures › Deck Plating
Issued 25 January 2017
Resolved
Treat (superficial rot) overhead of fishhold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 8 March 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 May 2016
Resolved
Provide flame shield for port and STBD fuel shutoff valves as per 46CFR182.455(b)(4)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 26 May 2016
Resolution: Master added aluminum plate for shielding fuel shutoff valves
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 26 May 2016
Resolved
Provide closures for exhaust as per 46CFR182.465(h)
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 26 May 2016
Resolution: Master provided proper vent cover for engine exhaust
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 26 May 2016
Resolved
Replace wasted grounding wire connecting to valve in engine room as pointed out by marine inspector as per 46CFR183.372(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 26 May 2016
Resolution: Master reattached grounding wire to sea chest valve
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 May 2016
Resolved
Provide 04 adult PFD's as per 46CFR180.71(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 26 May 2016
Resolution: Vessel owner provided (04) new PFD's on the spot