MAURY USCG vessel records Sign in
← All vessels

YONG AN CHENG

YONG AN CHENG is a 1992 freight ship. The Coast Guard has recorded 23 inspections since 2000, most recently in January 2010, along with 9 deficiencies and 7 operational controls, 1 with no removal date recorded.

Records from 2000 to 2010. Most recent: operational control imposed, 7 January 2010.

Built
1992
Last inspected
7 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8919532 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
496675
Flag
CHINA
—
Maury page id
psix-496675

Inspections, by type

…with no type recorded11
Years with a record 9 calendar years (2000–2010)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it22778 - Dead Weight, Ton
31022 - Displacement, Ton
16703 - Convention (Subpart B), Gross Ton
8748 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

7 January 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3660316
15 August 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3299061
1 September 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2766415
1 September 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2769650
25 April 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2632982
13 January 2006 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2566545
4 January 2006 PII Safety Exam · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2560490
18 August 2005 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2466614
20 December 2004 STCW 95 Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ILO-147 Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2262310
9 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2256671
22 August 2004 ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2172639
18 August 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2169620
17 August 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2168345
17 August 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2168737
19 March 2004 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2027455
5 December 2003 Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1959659
21 August 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1882632
22 April 2003 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1778633
29 December 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1723956
29 December 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1836449
8 May 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1614317
6 February 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 286769
9 June 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 278555

Deficiency record · 9

Communications › Alarms/Indicators › Bilge Alarm
Issued 7 January 2010 Resolved
Vessel's engine control room alarm panel is inoperative, rendering the alarm system unable to sound an audible alarm in the engine room. Vessel must make appropriate repairs to the satisfaction of the certificate issuing authority.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2010
Resolution: Received class report attesting to the appropriate repairs and operation of the engine control room alarm panel.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 December 2004 Resolved
ELECTRICAL CABLES BROKEN OFF AT OVERHEAD
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 22 December 2004
Resolved 18 August 2005
Resolution: CLEARED
Fire Fighting › Ventilation Systems › Operating Controls
Issued 20 December 2004 Resolved
SMOKE DAMPER IN P-WAY OUTSIDE ENGINE ROOM. HANDLE IS MISSING AND DAMPER IS NOT OPERATING PROPERLY
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 22 December 2004
Resolved 18 August 2005
Resolution: CORRECTED
Fire Fighting › Structural - A Class Divisions
Issued 5 December 2003 Resolved
IAW Fire Control Plan, the bulk head inbetween the Wheelhouse and Radio Room does not meet requirements of SOLAS. Have Class attest to proper boundary NLT 04JAN04. LEGACY COMPONENT DESC: Bulkheads - Control Stations
Due 4 January 2004
Resolved 6 December 2003
Resolution: Rerceived class report attesting to proper boundaries
Fire Fighting › Structural - A Class Divisions
Issued 5 December 2003 Resolved
IAW Fire Control Plan, fire door in stairwell on Poop deck is not equivalent to the division to which it is fitted. Have Class attest to proper boundary, NLT 04Jan04 LEGACY COMPONENT DESC: Bulkheads - Stairways
Due 4 January 2004
Resolved 19 March 2004
Resolution: RECEIVED CLASS REPORT. DEFICIENCY IS CLEARED.
Lifesaving › Launching Appliances
Issued 5 December 2003 Resolved
Repair winch for port lifeboat davit as per satisfaction of Class/Flag administration, prior to departure. LEGACY COMPONENT DESC: Winch
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2003
Resolved 6 December 2003
Resolution: Received class report attesting to proper repairs of winch clutch.
Deck/Cargo › Holds/Tanks
Issued 5 December 2003 Resolved
Properly secure Cargo hatch #1 & #2 as per satisfaction of Class/Flag administration, prior to departure. LEGACY COMPONENT DESC: Hatch
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2003
Resolved 6 December 2003
Deck/Cargo › Holds/Tanks
Issued 5 December 2003 Resolved
Repair piping on hydraulic line on cargo hold #2, as per satisfaction of Class/Flag Administration, prior to departure. LEGACY COMPONENT DESC: Hatch
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2003
Resolved 6 December 2003
Resolution: Received class report attesting to proper repair.
Lifesaving
Issued 9 June 2000 Resolved
PORT LIFEBOAT MISSING PORT HATCH.HATCH LOST DURING ABANDON SHIP DRILL ON THE 09JUN00. CORRECT TO THE SATISFACTION OF CLASS BY 09JUL00.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.