MAURY USCG vessel records
← All vessels

CHANDALAR

CHANDALAR is a 1978 passenger vessel (uninspected). The Coast Guard has recorded 12 inspections since 2016, most recently in May 2021, along with 36 deficiencies — 9 with no resolution recorded — and 3 operational controls.

Records from 2016 to 2021. Most recent: inspection, 24 May 2021.

Built
1978
Last inspected
24 May 2021
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 May 2021
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WSX5036
Flag
UNITED STATES
Maury page id
psix-49673

Documentation record

Registered dimensions (L × B × D)59.7 ft × 18.5 ft × 7.1 ft
Registered tonnagegross 65 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKELLY ENTERPRISES · WESTPORT, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portTACOMA, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 9 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

24 May 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7205424
20 July 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7048503
2 March 2020 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6907425
7 August 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6773995
9 November 2018 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6578408
1 April 2018 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6382866
30 March 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6378745
30 March 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6457097
28 October 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6296794
2 March 2017 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6097282
28 April 2016 Internal Structural Exam · Drydock Extension · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5881590
1 February 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5807347

Deficiency record · 36

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 24 May 2021 Resolved
Any vessel of at least 5 net tons which engages in the fisheries on navigable waters of the US or EEZ, or coastwise trade, must have a certificate of documentation bearing a valid endorsement. Vessel does not have a valid COD onboard. COD onboard expired September 2020. CITE; 46CFR67.7
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2021
Resolution: Vessel submitted new COD.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 May 2021 No resolution recorded
Every vesel shall be fitted with a suitable compass. At time of inspection, vessel did not have a compass onboard. CITE: 46CFR184.20-1
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2021 No resolution recorded
Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in a serious marine incident. Vessel did not posses alcohol testing strips. 46CFR4.06-3(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021 No resolution recorded
Each floating electric waterlight shall meet the requirements of ANSI/UL 1196. Vessels waterlight did not contain the correct battery. 46CFR161.010-2
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 May 2021 No resolution recorded
A pre-engineered fixed gas fire extinguishing system must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Fixed Halon system did not shut down diesel engines within space (mains/gen). 46CFR181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 24 May 2021 No resolution recorded
Except as noted in paragraphs (d) and (e) below, each vessel must be equipped with a public address system. Due to main service generator inoperable vessel did not have a public address system.
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2021 No resolution recorded
A vessels owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, at least two copies of plans for new generator installations. Portable gas powered generator on board was never reviewed by the Coast Guard and does not meet applicable requirements. 46CFR177.202
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2021 No resolution recorded
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel owner must provide proof of drug testing for all crew members. 46CFR16.210
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 24 May 2021 No resolution recorded
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years. The technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel needs to obtain a valid Communications Act Safety Radiotelephony Certificate. 47CFR80.903
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2021 No resolution recorded
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel must enclose exposed wires in galley and on the sundeck. 46CFR183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 November 2018 Resolved
Life jackets locked with zip-ties in forward closets. Each stowage container for life jackets must not be capable of being locked. you must provide arrangements to the satisfaction of the marine inspector.
Action required: 30 - Ship detained
Resolved 9 November 2018
Resolution: All life jackets out and labled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 November 2018 Resolved
Life jackets were stowed in vessel void and unmarked locations. Life jackets must be distributed throughout accomodation spaces and be readily available.
Action required: 30 - Ship detained
Resolved 9 November 2018
Resolution: Life jackets are distributed throught accomodation spaces and are readily available.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 November 2018 Resolved
Fire extinguishers not properly serviced. Portable fire extinguishers require monthly inspections in accordance to NFPA 10. Fire fighting must be serviced to satisfaction of marine inspectors.
Action required: 30 - Ship detained
Resolved 9 November 2018
Resolution: Fire extinguishers have been serviced.
Personnel › Training › Passenger Safety
Issued 29 May 2018 Resolved
Complete drills to ensure all crew members are familiar with assigned duties. During on board observation of man overboard drills vessel personnel were not familiar with assigned duties and failed to take assigned emergency actions. Perform training and complete drills to satisfaction of Marine Inspector 46CFR185.25-10
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2018
Resolution: Crew performed drills to satisfaction of Coast Guard Marine Inspectors
Communications › Radio Communications › VHF Radiotelephone
Issued 29 May 2018 Resolved
Provide emergency communication placard for VHF radios. A placard is required to be posted with emergency broadcast instructions and information specific to the vessel. You must provide emergency communication placard for VHF radios.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 4 June 2018
Resolution: Vessel representative added emergency broadcast radio placards
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 29 May 2018 Resolved
All electrical circuits must be clearly marked. Replace missing labels on engine room breaker panel. 46CFR183.222(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 4 June 2018
Resolution: Vessel representaive relabled all circut breakers
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 29 May 2018 Resolved
No logs were provided documenting drills. Logs shall be logged or documented for review by the Coast Guard. 46CFR185.520(f)(1)(2) 46CFR185 524(d)(1)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 4 June 2018
Resolution: Vessel representative reminded to document drills in the log for Coast Guard view upon request.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 29 May 2018 Resolved
Provide required amount of life jackets to each person carried on board. Only 64 serviceable life jackets were on board. Passenger count reduced to 64 until more life jacket are provided. 46CFR180.25-5(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2018
Resolved 4 June 2018
Resolution: Vessel representative replaced life jackets taken out of service
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 May 2018 Resolved
Life jacket instruction placard did not cover all types of life jackets on board. You must provide a placard for all life jacket types on board and must demonstrate compliance to the satisfaction of the Marine Inspector. 46CFR184.506
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2018
Resolved 4 June 2018
Resolution: Vessel representative added placards for all life jacket types on board.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 April 2018 Resolved
Vessel must undergo an annual inspection with 3 months before or after each anniversary date. Vessel inspection was over 2 months past the 3 months after COI anniversary. Inspection expanded to COI Inspection due to expiration of annual inspection date. 46CFR176.500(b)(1)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Deficiency rectified by conducting COI inspection due to expiration of anniversary date for annual.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 October 2017 Resolved
When passengers on board the vessel must be in compliance with COI. Vessel carying 128 passengers COI allows 72. 46 CFR 176.100B
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 November 2017
Resolved 28 October 2017
Personnel › Certificates/Documents/Licenses › License, Master
Issued 28 October 2017 Resolved
When passengers on board the vessel must be in compliance with COI. Vessel carying 128 passengers COI allows 72. 46 CFR 176.100B
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 28 October 2017
Resolution: Vessel did not operate over COI limit.
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 March 2017 Resolved
Conduct satisfactory fire and abandon ship drills with Coast Guard Marine Inspector present. 46 CFR 176.500(a)(ii) and 46 CFR 176.404(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2017
Resolution: Re-attended vessel, master conducted drills.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 2 March 2017 Resolved
Provide Coast Guard letter detailing MMC backup and proof of MMC application. 46 CFR 10.205
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2017
Resolution: Re-attended vessel, master provided proof of application.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 March 2017 Resolved
Repair bilge high level alarms; (1) engine room: light and (2)tank room: audible and light. 46 CFR 182.530(a)
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 14 March 2017
Resolution: Re-attended vessel, master properly operated bilge high level alarms.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 March 2017 Resolved
Provide first aid kit with new (not expired) medical supplies. 46 CFR 184.710
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 14 March 2017
Resolution: Re-attended vessel, master provided new medication.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 March 2017 Resolved
Provide fire servicing certificate to prove test of pre-engineered fire extinguishing system (including override). 46 CFR 176.810(a)
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 14 March 2017
Resolution: Re-attended vessel, provided proof of completed servicing.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2017 Resolved
Remove portable extension cord. 46 CFR 183.340(r)
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 14 March 2017
Resolution: Re-attended vessel, master removed extension cord.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2017 Resolved
Replace zip ties with metal supports (attach cable to vessel itself not to other cables). 46 CFR 183.340(b)(4)
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 14 March 2017
Resolution: Re-attended vessel, new metal supports installed.
Engineering › Sea-water System (primary cooling) › Valve
Issued 4 May 2016 Resolved
Replace 02 gate valves for raw water cooling system.
Action required: 705 - Other - as specified
Resolved 4 May 2016
Resolution: Owner purchased 02 new gate valves to be installed by Yard.
Engineering › Bilge Water Management System › Not Operational
Issued 9 February 2016 Resolved
Audible alarms not operating for the bilge system. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2016
Resolution: Returned to vessel and tested all bilge high level alarms. All working-vessel operator had accidently cut wires mistaking them for unused wiring.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 February 2016 Resolved
Provide documentation of successful override function of fire extinguishing system in Engine room. 46 CFR 181.420 (b)(3)
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 12 February 2016
Resolution: Fire servicing technician provided report of all tests conducted during annual servicing in November.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 February 2016 Resolved
Secure both battery boxes in Engine Room. 46 CFR 183.05-20 (b)
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 12 February 2016
Resolution: Both batteries were secured using new straps.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 9 February 2016 Resolved
Tighten packing on both shafts. 46 CFR 182.100
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 12 February 2016
Resolution: Shafts were tightened. There is no longer a continuous drip on system.
Documentation › Markings/Placards › Capacity Marking
Issued 9 February 2016 Resolved
Change upper deck marking to 17 as per current Stability Letter dated, 25 Apr 12. 46 CFR 178.230
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 12 February 2016
Resolution: Upper deck marked with 17 as per stability letter.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 February 2016 Resolved
Show proper operation of forward masthead light. 46 CFR 183.420 Prior to operating at night/restricted visibility.
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 12 February 2016
Resolution: Fwd masthead light working properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.