MAURY USCG vessel records Sign in
← All vessels

FISH 'N FUN

FISH 'N FUN is a 1960 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 1985, most recently in January 1999, along with 65 deficiencies.

Records from 1985 to 1999. Most recent: inspection, 15 January 1999.

Built
1960
Last inspected
15 January 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WM9771
Flag
UNITED STATES
—
Maury page id
psix-49679

Inspections, by type

…with no type recorded1
Years with a record 13 calendar years (1985–1999)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Net Ton
15 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCS9389MMSI not assigned · expired · compulsorily equipped · granted 29 June 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

15 January 1999 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 809568
27 May 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792904
8 April 1998 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792910
17 April 1997 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1368182
18 April 1996 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1416287
3 April 1996 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1416286
2 May 1995 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1358745
3 June 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1178116
12 May 1994 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 865413
26 April 1993 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1436771
25 March 1993 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1410794
27 April 1992 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1435317
24 October 1991 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 934506
22 August 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 940951
6 June 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 931843
20 December 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 931893
3 May 1990 COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 924577
11 April 1990 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 901282
6 May 1988 Re-Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1204079
7 May 1987 Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1027459
1 May 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 987640

Deficiency record · 65

Lifesaving
Issued 27 May 1998 Resolved
Provide Distress Signal Box of a bright color stenciled "Distress Signals"
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 27 May 1998 Resolved
Install new Buoyant Apparatus weak link and properly attach to vessel.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 27 May 1998 Resolved
Provide 1 new adult PFD and retape shoulders of all others.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Navigation
Issued 27 May 1998 Resolved
Prove operation of stern light.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 27 May 1998 Resolved
Seperate Child PFDs.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Construction/Loadline › Hull › Bottom Plating
Issued 8 April 1998 Resolved
Remove all bottom plywood and refasten boat by 31 dec 98.
Condition: Unknown
Due 31 December 1998
Resolved 17 November 2005
Resolution: Admin - COI Deactivated
Documentation
Issued 17 April 1997 Resolved
OBTAIN CURRENT TABLES.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Documentation
Issued 17 April 1997 Resolved
OBTAIN CURRENT CERTIFICATE OF DOCUMENTATION STICKER.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 17 April 1997 Resolved
OBTAIN BASIC FIRST AID INSTRUCTION BOOKLET.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Construction/Loadline
Issued 18 April 1996 Resolved
REPAIR HOLE IN DECK IN FWD CABIN.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996 Resolved
BA HAD INSUFFICIENT RETROFLECTIVE TAPE APPLIED. NEED FOUR STRIPS NO LESS THAN 2" WIDE ON ALL SIDES CIRCLING BA.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996 Resolved
INSUFFICIENT RETROFLECTIVE TAPE ON RING BUOY. NEED MINIMUM 2" WIDTH RETRO TAPE ON FOUR SIDES CIRCLING RING BUOY.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Fire Fighting
Issued 18 April 1996 Resolved
B-I WAS REMOVED FROM WHEELHOUSE, IT HAD LOST IT'S CHARGE. NEED TO REPLACE/RECHARGE B-I PORT FIRE EXT.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996 Resolved
OWNER WAS SHORT ONE ADULT PFD. NEED TO ATTAIN ONE MORE ADULT PFD.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
REPAIR MANUAL SWITCH FOR FWD BILGE PUMP IN CABIN INOP.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Electrical
Issued 18 April 1996 Resolved
CONNECT FUEL TANK TO THE COMMON GROUND.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996 Resolved
PROVIDE & PROPERLY LABEL STORAGE FOR SEVEN ADULT PFD'S.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Unknown
Issued 18 April 1996 Resolved
ASSEMBLE/PROVIDE FIRST AID KIT WITH SUFFICIENT SUPPLIES.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996 Resolved
PROVIDE LIFE JACKET DONNING INSTRUCTION PLACARD FOR "HORSE COLLAR" TYPE PFD.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Engineering
Issued 18 April 1996 Resolved
REPAIR LEAK IN PORT EXHAUST LINE NEAR ENGINE CONNECTION.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Electrical
Issued 2 May 1995 Resolved
Remove dead end wiring no longer in use throughout wheelhouse._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Electrical
Issued 2 May 1995 Resolved
Batteries not properly secured to prevent shifting. Terminal leads were wing nut type, need to change out to lug type._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Electrical
Issued 2 May 1995 Resolved
Remount wiring to fuse pannel under steering console._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Engineering
Issued 2 May 1995 Resolved
Flame screens holed, replace._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Electrical
Issued 2 May 1995 Resolved
Compass light not operational. Need to connect wiring._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Construction/Loadline
Issued 2 May 1995 Resolved
Aft bilge pump auto float switch inop. Pump works on manual._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Lifesaving
Issued 2 May 1995 Resolved
Replace 04 lifejackets and restencil all jackets with vessel name._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Lifesaving
Issued 2 May 1995 Resolved
Re-install weak link for bouyant apparatus.
Condition: Unknown
Due 2 May 1995
Resolved 1 April 1996
Construction/Loadline
Issued 25 March 1993 Resolved
Crop and renew topside plank starboard side in way of cooling water discharge.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Engineering
Issued 25 March 1993 Resolved
Replace fuel tank due to soft patch repairs to tank.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Construction/Loadline
Issued 25 March 1993 Resolved
Crop and renew topside plank port side in way of bilge pump discharge midships.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Construction/Loadline
Issued 25 March 1993 Resolved
Rebed raw water intake for main engine.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Electrical
Issued 27 April 1992 Resolved
REPLACE UNAPPROVED LIGHT FIXTURES WITH PROPER MARINE GRADE
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Electrical
Issued 27 April 1992 Resolved
REMOVE CRACKED 8D BATTERY FROM VESSEL
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 27 April 1992 Resolved
INSTALL RETROREFLECTIVE TAPE ON B/A
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Electrical
Issued 27 April 1992 Resolved
REMOVE ELECTRICAL WIRES FROM BILGES
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 27 April 1992 Resolved
REPAIR #4 FLOOR TIMBER_x001C_ _x001C_
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Engineering
Issued 27 April 1992 Resolved
MAKE FUEL TANK ACCESSIBLE TO HAVE A STATIC HEAD TEST CONDUCTED
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Engineering
Issued 27 April 1992 Resolved
INSTALL APPROVED TYPE OF EXHAUST PIPE AND REMOVE PVC PIPE
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Engineering
Issued 27 April 1992 Resolved
REMOVE PVC PIPE FROM ENGINE COOLING SYSTEM. DISCHARGE SIDE
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 6 June 1991 Resolved
INSTALL 18' LINES TO BOTH FLOATLIGHTS
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Lifesaving
Issued 6 June 1991 Resolved
FASTEN BA LIFE LINES IN LIGHTS NOT LONGER THAN 3 FT
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Navigation
Issued 6 June 1991 Resolved
REPLACE TORN EMERGENCY CHECK OFF LIST
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Lifesaving
Issued 6 June 1991 Resolved
TRICE PENDANTS ON BA
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Construction/Loadline
Issued 6 June 1991 Resolved
DRYDOCK VESSEL NO LATER THAN 1DEC91 FOR EXMINATION BY COAST GUARD MARINE INSPECTOR
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Fire Fighting
Issued 6 June 1991 Resolved
PROVIDE B-II FIRE EXTINGUISHER BRACKETS #809
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Lifesaving
Issued 6 June 1991 Resolved
PROVIDE ADDITIONAL 4 ADULT TYPE I PFD'S. UNTIL THIS REQUIREMENTS IS COMPLETED, 12 HR OPERATIONS-PASSENGERS LIMITED TO 20 AND WHEN OPERATING MORE THAN 12 HOURS IN ANY 24 HOUR PERIOD, PASSENGERS LIMITED TO 18
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Electrical
Issued 6 June 1991 Resolved
SECURE BATTERIES IN BATTERY BOX TO KEEP FROM MOVING/SLIDING
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Engineering
Issued 6 June 1991 Resolved
CLEAN F/O VENT FLAME SCREEN
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Engineering
Issued 6 June 1991 Resolved
REPAIR/REPLACE/REMOVE ENGINE TACHOMETER
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Navigation
Issued 3 May 1990 Resolved
PLACE COPY OF LIGHT LIST ON VESSEL
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Documentation
Issued 3 May 1990 Resolved
PROVIDE DRUG TESTING CERTIFICATION LETTER TO MARINE SAFETY OFFICE
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Navigation
Issued 3 May 1990 Resolved
REPLACE U-BOLTS ON STEERING GEAR CABLE
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Lifesaving
Issued 3 May 1990 Resolved
PLACE WEAK LING ON BUOYANT APPARATUS PAINTER. PAINTER TO BE SHORTENED TO 100' ONCE WEAK LINK IS ATTACHED. OPERATIONG LIMITED TO ABOVE SMITH POINT UNTIL THIS IS ACCOMPLISHED
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Unknown
Issued 7 May 1987 Resolved
PROVIDE PROPER PLASTIC LINES OR LEAD LINED BATTERY BOX.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
PROVIDE OPERABLE ANCHOR LIGHT.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
PROVIDE/RENEW GRABLINES ON (2) TWO RING BUOYS.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
PROVIDE EMERGENCY FUEL SHUTOFF VALVE HANDLES.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
PROVE SATISFACTORY OPERATION OF HORN.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
PROPERLY LABEL PERSONAL FLOTATION DEVICE STORAGE LOCKERS.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
PROVIDE OPERABLE WATERLIGHT FOR BOUYANT APPARATUS.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
POST ALL VESSEL FCC CERTIFICATES AND CERTIFICATE ON INSPECTION.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
CLEAN BILGE OF ALL DIRT AND OILY RESIDUE.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
PROVIDE DOUBLE HOSE CLAMPS ON ENTIRE ENGINE EXHAUST SYSTEM.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987 Resolved
REMOVE FROM VESSEL OR STOW ALL MISCELLANEOUS NON-REQUIRED EQUIPMENT AND BUILDING MATERIAL.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.