Records from 1985 to 1999. Most recent: inspection, 15 January 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
15 January 1999
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 809568
27 May 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792904
8 April 1998
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792910
17 April 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1368182
18 April 1996
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1416287
3 April 1996
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1416286
2 May 1995
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1358745
3 June 1994
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1178116
12 May 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 865413
26 April 1993
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1436771
25 March 1993
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1410794
27 April 1992
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1435317
24 October 1991
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 934506
22 August 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 940951
6 June 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 931843
20 December 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 931893
3 May 1990
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 924577
11 April 1990
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 901282
6 May 1988
Re-Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1204079
7 May 1987
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1027459
1 May 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 987640
Lifesaving
Issued 27 May 1998
Resolved
Provide Distress Signal Box of a bright color stenciled "Distress Signals"
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 27 May 1998
Resolved
Install new Buoyant Apparatus weak link and properly attach to vessel.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 27 May 1998
Resolved
Provide 1 new adult PFD and retape shoulders of all others.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Navigation
Issued 27 May 1998
Resolved
Prove operation of stern light.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 27 May 1998
Resolved
Seperate Child PFDs.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Construction/Loadline › Hull › Bottom Plating
Issued 8 April 1998
Resolved
Remove all bottom plywood and refasten boat by 31 dec 98.
Condition: Unknown
Due 31 December 1998
Resolved 17 November 2005
Resolution: Admin - COI Deactivated
Documentation
Issued 17 April 1997
Resolved
OBTAIN CURRENT TABLES.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Documentation
Issued 17 April 1997
Resolved
OBTAIN CURRENT CERTIFICATE OF DOCUMENTATION STICKER.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 17 April 1997
Resolved
OBTAIN BASIC FIRST AID INSTRUCTION BOOKLET.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Construction/Loadline
Issued 18 April 1996
Resolved
REPAIR HOLE IN DECK IN FWD CABIN.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996
Resolved
BA HAD INSUFFICIENT RETROFLECTIVE TAPE APPLIED. NEED FOUR STRIPS NO LESS THAN 2" WIDE ON ALL SIDES CIRCLING BA.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996
Resolved
INSUFFICIENT RETROFLECTIVE TAPE ON RING BUOY. NEED MINIMUM 2" WIDTH RETRO TAPE ON FOUR SIDES CIRCLING RING BUOY.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
B-I WAS REMOVED FROM WHEELHOUSE, IT HAD LOST IT'S CHARGE. NEED TO REPLACE/RECHARGE B-I PORT FIRE EXT.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996
Resolved
OWNER WAS SHORT ONE ADULT PFD. NEED TO ATTAIN ONE MORE ADULT PFD.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Construction/Loadline
Issued 18 April 1996
Resolved
REPAIR MANUAL SWITCH FOR FWD BILGE PUMP IN CABIN INOP.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Electrical
Issued 18 April 1996
Resolved
CONNECT FUEL TANK TO THE COMMON GROUND.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996
Resolved
PROVIDE & PROPERLY LABEL STORAGE FOR SEVEN ADULT PFD'S.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Unknown
Issued 18 April 1996
Resolved
ASSEMBLE/PROVIDE FIRST AID KIT WITH SUFFICIENT SUPPLIES.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Lifesaving
Issued 18 April 1996
Resolved
PROVIDE LIFE JACKET DONNING INSTRUCTION PLACARD FOR "HORSE COLLAR" TYPE PFD.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Engineering
Issued 18 April 1996
Resolved
REPAIR LEAK IN PORT EXHAUST LINE NEAR ENGINE CONNECTION.
Condition: Unknown
Due 26 April 1996
Resolved 25 April 1996
Electrical
Issued 2 May 1995
Resolved
Remove dead end wiring no longer in use throughout wheelhouse._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Electrical
Issued 2 May 1995
Resolved
Batteries not properly secured to prevent shifting. Terminal leads were wing nut type, need to change out to lug type._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Electrical
Issued 2 May 1995
Resolved
Remount wiring to fuse pannel under steering console._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Engineering
Issued 2 May 1995
Resolved
Flame screens holed, replace._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Electrical
Issued 2 May 1995
Resolved
Compass light not operational. Need to connect wiring._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Construction/Loadline
Issued 2 May 1995
Resolved
Aft bilge pump auto float switch inop. Pump works on manual._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Lifesaving
Issued 2 May 1995
Resolved
Replace 04 lifejackets and restencil all jackets with vessel name._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 1 April 1996
Lifesaving
Issued 2 May 1995
Resolved
Re-install weak link for bouyant apparatus.
Condition: Unknown
Due 2 May 1995
Resolved 1 April 1996
Construction/Loadline
Issued 25 March 1993
Resolved
Crop and renew topside plank starboard side in way of cooling water discharge.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Engineering
Issued 25 March 1993
Resolved
Replace fuel tank due to soft patch repairs to tank.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Construction/Loadline
Issued 25 March 1993
Resolved
Crop and renew topside plank port side in way of bilge pump discharge midships.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Construction/Loadline
Issued 25 March 1993
Resolved
Rebed raw water intake for main engine.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Electrical
Issued 27 April 1992
Resolved
REPLACE UNAPPROVED LIGHT FIXTURES WITH PROPER MARINE GRADE
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Electrical
Issued 27 April 1992
Resolved
REMOVE CRACKED 8D BATTERY FROM VESSEL
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 27 April 1992
Resolved
INSTALL RETROREFLECTIVE TAPE ON B/A
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Electrical
Issued 27 April 1992
Resolved
REMOVE ELECTRICAL WIRES FROM BILGES
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 27 April 1992
Resolved
REPAIR #4 FLOOR TIMBER_x001C_ _x001C_
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Engineering
Issued 27 April 1992
Resolved
MAKE FUEL TANK ACCESSIBLE TO HAVE A STATIC HEAD TEST CONDUCTED
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Engineering
Issued 27 April 1992
Resolved
INSTALL APPROVED TYPE OF EXHAUST PIPE AND REMOVE PVC PIPE
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Engineering
Issued 27 April 1992
Resolved
REMOVE PVC PIPE FROM ENGINE COOLING SYSTEM. DISCHARGE SIDE
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 6 June 1991
Resolved
INSTALL 18' LINES TO BOTH FLOATLIGHTS
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Lifesaving
Issued 6 June 1991
Resolved
FASTEN BA LIFE LINES IN LIGHTS NOT LONGER THAN 3 FT
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Navigation
Issued 6 June 1991
Resolved
REPLACE TORN EMERGENCY CHECK OFF LIST
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Lifesaving
Issued 6 June 1991
Resolved
TRICE PENDANTS ON BA
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Construction/Loadline
Issued 6 June 1991
Resolved
DRYDOCK VESSEL NO LATER THAN 1DEC91 FOR EXMINATION BY COAST GUARD MARINE INSPECTOR
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Fire Fighting
Issued 6 June 1991
Resolved
PROVIDE B-II FIRE EXTINGUISHER BRACKETS #809
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Lifesaving
Issued 6 June 1991
Resolved
PROVIDE ADDITIONAL 4 ADULT TYPE I PFD'S. UNTIL THIS REQUIREMENTS IS COMPLETED, 12 HR OPERATIONS-PASSENGERS LIMITED TO 20 AND WHEN OPERATING MORE THAN 12 HOURS IN ANY 24 HOUR PERIOD, PASSENGERS LIMITED TO 18
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Electrical
Issued 6 June 1991
Resolved
SECURE BATTERIES IN BATTERY BOX TO KEEP FROM MOVING/SLIDING
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Engineering
Issued 6 June 1991
Resolved
CLEAN F/O VENT FLAME SCREEN
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Engineering
Issued 6 June 1991
Resolved
REPAIR/REPLACE/REMOVE ENGINE TACHOMETER
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Navigation
Issued 3 May 1990
Resolved
PLACE COPY OF LIGHT LIST ON VESSEL
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Documentation
Issued 3 May 1990
Resolved
PROVIDE DRUG TESTING CERTIFICATION LETTER TO MARINE SAFETY OFFICE
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Navigation
Issued 3 May 1990
Resolved
REPLACE U-BOLTS ON STEERING GEAR CABLE
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Lifesaving
Issued 3 May 1990
Resolved
PLACE WEAK LING ON BUOYANT APPARATUS PAINTER. PAINTER TO BE SHORTENED TO 100' ONCE WEAK LINK IS ATTACHED. OPERATIONG LIMITED TO ABOVE SMITH POINT UNTIL THIS IS ACCOMPLISHED
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Unknown
Issued 7 May 1987
Resolved
PROVIDE PROPER PLASTIC LINES OR LEAD LINED BATTERY BOX.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
PROVIDE OPERABLE ANCHOR LIGHT.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
PROVIDE/RENEW GRABLINES ON (2) TWO RING BUOYS.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
PROVIDE EMERGENCY FUEL SHUTOFF VALVE HANDLES.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
PROVE SATISFACTORY OPERATION OF HORN.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
PROPERLY LABEL PERSONAL FLOTATION DEVICE STORAGE LOCKERS.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
PROVIDE OPERABLE WATERLIGHT FOR BOUYANT APPARATUS.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
POST ALL VESSEL FCC CERTIFICATES AND CERTIFICATE ON INSPECTION.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
CLEAN BILGE OF ALL DIRT AND OILY RESIDUE.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
PROVIDE DOUBLE HOSE CLAMPS ON ENTIRE ENGINE EXHAUST SYSTEM.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Unknown
Issued 7 May 1987
Resolved
REMOVE FROM VESSEL OR STOW ALL MISCELLANEOUS NON-REQUIRED EQUIPMENT AND BUILDING MATERIAL.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987