MAURY USCG vessel records Sign in
← All vessels

STARLIGHT

STARLIGHT is a 1978 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1985, most recently in May 2026, along with 237 deficiencies and 2 casualty investigations in 2011.

Records from 1985 to 2026. Most recent: inspection, 21 May 2026.

Built
1978
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP5951
Flag
UNITED STATES
368368060
Maury page id
psix-49685

Inspections, by type

…with no type recorded6
Years with a record 39 calendar years (1985–2026)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)68.7 ft × 22.1 ft × 6.7 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1978
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCAPE MAY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5951MMSI 368368060 · active · compulsorily equipped · granted 16 May 2024, expires 16 May 2034
WDM3724MMSI 367442940 · cancelled · compulsorily equipped · granted 20 May 2021, cancelled 20 April 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDD6424MMSI 367172790 · expired · compulsorily equipped · granted 13 March 2007, cancelled 13 May 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDC5451MMSI 367041290 · expired · compulsorily equipped · granted 11 May 2005, cancelled 11 July 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCQ7525MMSI not assigned · expired · voluntarily equipped · granted 10 April 1995, cancelled 11 June 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 86

21 May 2026 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8367211
3 September 2025 Annual Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8226219
30 October 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8026929
9 October 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8015543
16 May 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7912484
3 April 2023 Annual Inspection · In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7661549
16 March 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7652215
10 February 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7634696
15 April 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7446122
29 September 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7322355
29 April 2021 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7185852
23 March 2021 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7161401
18 June 2020 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6924631
16 October 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6820855
4 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6688792
22 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6384974
13 October 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6282091
9 May 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6199715
6 June 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5899248
20 April 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5858321
4 June 2014 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4879119
6 March 2014 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4812282
10 January 2012 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4222146
22 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4096509
25 October 2010 Inclining Experiment
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3877084
11 January 2010 Deficiency Check · COI Inspection · Administrative Inspection · Deadweight Survey · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3662589
23 September 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3331043
20 September 2008 Type not recorded
No type recorded · Station Sandy Hook · USCG Northeast District (CGD-NE) · Activity 3330011
7 July 2008 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3267538
6 May 2008 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3199796
19 April 2007 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2911031
6 June 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2672106
2 May 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2638390
3 May 2005 Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2348057
9 March 2004 Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2020778
22 December 2003 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1968105
14 April 2003 Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1773253
20 March 2002 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1495053
3 December 2001 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1407042
24 August 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073430
18 June 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1070653
12 March 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384702
19 October 2000 Type not recorded
No type recorded · Station Sandy Hook · USCG Northeast District (CGD-NE) · Activity 1514125
2 March 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1436339
28 December 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1046830
11 March 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384061
25 August 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1131875
23 July 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 795454
21 July 1998 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1129722
6 April 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1125690
14 January 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1107746
14 January 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1461008
13 March 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1095688
9 May 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085506
18 March 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077617
18 March 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1092862
17 January 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186350
21 March 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135228
12 December 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1144104
5 April 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857054
18 March 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857202
3 March 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857723
21 January 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853178
18 March 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836207
3 February 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135719
9 April 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 960904
9 April 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254453
3 July 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941194
22 May 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934153
10 April 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219631
9 January 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1240887
24 August 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219243
8 May 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226483
10 April 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218120
3 January 1990 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227254
19 April 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032136
2 March 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1196095
1 July 1988 Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340668
19 April 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039717
13 April 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343979
13 April 1988 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1344243
6 April 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329780
29 April 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000551
21 March 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1305494
9 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 980065
19 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289497

Deficiency record · 237

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 September 2025 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Provide service report for Fixed CO2 system and portable extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2025
Resolved 5 September 2025
Resolution: Summit fire report completed, all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 September 2025 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The EPIRB hydrostatic release was expired.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2025
Resolved 5 September 2025
Resolution: Hydrostatic release installed, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 September 2025 Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. For fire hydrants located on open decks or cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or cargo handling operations, respectively. Hoses so removed must be stored in nearby accessible locations. Replace fire hose.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2025
Resolved 5 September 2025
Resolution: Fire hose replaced, All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 September 2025 Resolved
The means used to attach the float-free link to the vessel must have a breaking strength of at least the breaking strength of the painter. Life floats were found fastened to the uppermost deck by means of the painter housing.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2025
Resolved 5 September 2025
Resolution: Life float line re-rigged, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2025 Resolved
Each lifejacket must be approved under approval series in subparts 160.002, 160.005, 160.055, 160.115, 160.176, or 160.255, or other standard specified by the Commandant. MI found 7 life jackets that were either not approved for small passenger vessel service or damaged to the point of being unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 5 September 2025
Resolution: Lifejackets replaced and retro tape renewed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 September 2025 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. All life float paddles were cracking and unserviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 5 September 2025
Resolution: Paddles replaced, all sat.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 3 September 2025 Resolved
Use of a Coast Guard type-approved AIS Class B device in lieu of an AIS Class A device is permissible on the following vessels if they are not subject to pilotage by other than the vessel Master or crew: Vessels identified in paragraph (b)(1)(i) of this section that are certificated to carry less than 150 passengers. Vessel does not have AIS, Owner/Operator instructed to install Class "B" AIS transponder.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2025
Resolved 8 September 2025
Resolution: Vessel provided prrof of funcional AIS onboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 September 2025 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section: Discharge hose on CO2 has wasted fitting. Fitting to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2025
Resolved 5 September 2025
Resolution: Fitting replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 September 2025 Resolved
A collision bulkhead must not be fitted with any type of penetration or opening except penetrations may be made if they are located as high and as far inboard as practicable and they have a means to make them watertight. The collision bulkhead had two vent penetrations that were not watertight in way of the most outboard locations of both the port and starboard-most reaches of the bulkhead.46 CFR 179.310(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 5 September 2025
Resolution: Penetrations closed, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 September 2025 Resolved
No person may operate a vessel to which this part applies unless they have on board in hard copy or digital form a valid certificate of number or temporary certificate for that vessel issued by the issuing authority in the State in which the vessel is principally operated. The vessel does not have a valid certificate of number for the state of Florida. 33CFR173.21(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 1 December 2025
Resolution: Certs updated, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2025 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Hydraulic lines serving the anchor windlass were cracked. 46 CFR182.720(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 1 December 2025
Resolution: Hydraulic lines replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2025 Resolved
Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose and must comply with SAE J-1475. Hose end fittings serving the hydraulic lines for the anchor windlass were unsuitably corroded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 1 December 2025
Resolution: Fittings replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2025 Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided at such locations where persons or equipment might come in contact with an exhaust pipe. The port side main engine exhaust lagging was missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 1 December 2025
Resolution: Lagging replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 September 2025 Resolved
Water for cooling the exhaust pipe, must be injected into the exhaust system as near to the engine manifold as practicable, and that water must pass through the entire length of the exhaust pipe. Center main engine lagging was leaking raw cooling water between its injection point and the exhaust terminus as evidenced by the accumulation of salt in the engine room below the exhaust pipe.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 1 December 2025
Resolution: Leak repaired, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 September 2025 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Bulkhead in lazarette to engine room has penetrations that need to be watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 5 September 2025
Resolution: Penetrations sealed, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 September 2025 Resolved
A hatch exposed to the weather must be watertight. Forward hatch for collision bulkhead needs to be fully operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 1 December 2025
Resolution: Hatch replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2025 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Piping on port engine water pump to heat exchanger has a patch. Piping must be approved type or replaced in kind.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 5 September 2025
Resolution: Pipe replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 May 2024 Resolved
For fixed gas fire extinguishing system, The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel had a custom fixed co2 system that had not been serviced since March 2023. Service the fixed C02 system to the satisfaction of the attending marine inspector. 46CFR810(b)2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
Resolution: Received report ad invioce attesting to the serviceing of the CO2 Fire Suppression system. Report Uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2024 Resolved
Fire hose shall have a nozzle that has a 1/2 inch solid stream Orifice or a combination nozzle. Vessel did not have a nozzle attached to fire hose. Install nozzle on the fire hose to the satisfaction of the attending marine inspector. 46CFR181.15-10(c)(1) (Old "T")
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
Resolution: Received video of the installation of fire nozzle onto the fire hose. Video showed adequate pressure and varying spray patterns.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 May 2024 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Vessel did not have a pressure gauge installed. Install pressure gauge at the pump outlet to the satisfaction of the attending marine inspector. 46CFR182.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2024
Resolved 30 May 2024
Resolution: Received photo of pressure guage installed on fire pump.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 16 May 2024 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Vessel did not have the anchor fitted to the vessel for use. Install anchor. 46CFR184.300
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
Resolution: Anchor on vessel was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2024 Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead. Valve was not operable. Replace valve in forward compartment to the satisfaction of the attending marine inspector. 46CFR181.10-1c (Old "T")
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
Resolution: Received video of the replacement valve on forward compartment. Video showed valve exercised.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel had 17 life jackets that needed retro reflective tape replaced and two life jackets were condemned. Repair the 17 life jackets and replace the two condemned life jackets. 46cfr176.808c
Action required: 705 - Other - as specified
Resolved 25 June 2024
Resolution: Received photographic evidence of new retro-reflective tape on life jackets and two new additional life jackets on board.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 May 2024 Resolved
Unless normal use of the radiotelephone installation demonstrates that the equipment is in proper operating condition. VHF radio did not have the MSSI number programmed in. Install MSSI number. 47CFR80.931
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2024
Resolution: Revieved Photo of MMSI # programed into VHF Radio.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2024 Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Install covers on batteries. 46CFR183.354(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received photo of battery with installed covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2024 Resolved
Receptacle outlets of the type providing a grounded pole or a specific direct current polarity must be of a configuration that will not permit improper connection. Install outlet cover on Fwd Starboard bulkhead. 183.220(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received photo of instaled outlet covers.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 16 May 2024 Resolved
Operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Blank off overboard discharge. 33CFR1597(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received photo of sewage discharge pipe capped off.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 May 2024 Resolved
Double hose clamping is required where practicable in systems and application where flexible hoses are permitted to be clamped. Install double hose clamps. 46CFR182.410d(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received photo of double hose clamps installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 April 2023 Resolved
Spaces containing propulsion machinery are required to to be equipped with a fire detection system. Heat detection system in engine room was no longer operable. 46 CFR 181.405 (disregard below)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 19 April 2023
Resolution: Conducted satisfactory test of new heat detection system; activiated detectors, actuated test mode, and operated with both power sources. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2023 Resolved
All equipment including switches shall be of a type designed for the potential involved and so identified. The generator selector switches in the engine room require the knobs designed for properly turning switches. 46 CFR 183.10-20 (OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 26 April 2023
Resolution: New switch was satisfactorily installed. Delay was caused by damaged unit being shipped to vessel initially.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2023 Resolved
All machinery must be maintained in such a manner as to afford adequate protection against failure. Spring on the STBD engine shutoff assembly was being held by a zip tie and needs to be replaced with a new part. 46 CFR 182.01-5 (OLD T)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 19 April 2023
Resolution: Spring was replaced. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2023 Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose of its intended service. Grab lines on several life floats and the basket on one were deteriorated. 46 CFR 180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 26 April 2023
Resolution: Almost all life lines were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2023 Resolved
A life preserver shall not be appreciably deteriorated. 10 life jackets on the upper deck were found to be significantly deteriorated and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 19 April 2023
Resolution: Observed new, satisfactory life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 April 2021 Resolved
46 CFR 182.20-25 Sounding gage for independent fuel tanks were not of a heat resistant material and did not have a means to automatically close. Due prior to next credit dry dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 February 2023
Resolution: Next drydock to be completed by 30SEP2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2021 Resolved
46 CFR 183.05-20 Batteries do not have covers/ protection from objects falling on terminals.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 10 May 2021
Resolution: Received photos of battery covers installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2021 Resolved
46 CFR 177.35-15 Pullies on center and port side main engines do not have guards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 10 May 2021
Resolution: Received photos of engine guards installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 June 2020 Resolved
Life-floats were left detached from weak link after rep serviced. properly re-connect.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2020
Resolved 18 June 2020
Resolution: Re-connected
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 June 2020 Resolved
Water light for one of the life floats was not properly secured repair or replace light.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2020
Resolved 18 June 2020
Resolution: Repaired water light.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 June 2019 Resolved
Replace battery and hydrostatic release prior to operating more than 3 miles from shore with passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 3 July 2019
Resolution: O/O provided proof of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2019 Resolved
replace ring buoy
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 20 June 2019
Resolved 20 June 2019
Resolution: O/O provided proof of corrected item.
Engineering › Bilge Water Management System › Pump
Issued 8 June 2016 Resolved
Repair clutch for stbd pump (for bilge piping system)
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 20 June 2016
Resolution: Replaced Belt, and operated successfully
Communications › Radio Communications › VHF Radiotelephone
Issued 8 June 2016 Resolved
Program MMSI# into VHF/DSC capable radio per MSIB.
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 20 June 2016
Documentation › Certificates/Documents › Stability Letter
Issued 8 June 2016 Resolved
Post stability letter with COI in operating station.
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 20 June 2016
Navigation › Piloting/Steering › Marine Charts
Issued 8 June 2016 Resolved
Provide updated chart for area of operation.
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 20 June 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 June 2016 Resolved
Label, and put retro on RLB's on aft and port of operating station.
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 20 June 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 June 2014 Resolved
Make line for electric Light on ring buoy 3-6 feet.
Due 4 July 2014
Resolved 1 July 2014
Resolution: Recieved emailed picture of correct amount of line.
Engineering › Bilge Water Management System › Manifold
Issued 4 June 2014 Resolved
Label Bilge Manifold.
Due 4 July 2014
Resolved 1 July 2014
Resolution: Manifold properly labeled.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 June 2014 Resolved
Replace the battery in light prior to operating greater then LBC route.
Condition: Improper/Lack of Maintenance
Due 4 July 2014
Resolved 1 July 2014
Resolution: Battery replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 June 2014 Resolved
Provide (05) adult life jackets. Passenger count reduced by 5 until provided.
Due 4 July 2014
Resolved 1 July 2014
Resolution: Life jackets provided.
Construction/Loadline › Hull › Transverse Frame
Issued 6 March 2014 Resolved
Inspect and refasten interior frames in lazarette.
Action required: 705 - Other - as specified
Resolved 7 April 2014
Resolution: Lazarette was refastened throughout. Aprox 80+ new fasteners were added to interior frames.
Stability › Watertight Integrity › General
Issued 6 March 2014 Resolved
Make all bulkheads watertight. Bulkheads throughout were not water tight.
Action required: 705 - Other - as specified
Resolved 7 April 2014
Resolution: Bulkheads in lazarette were made watertight.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 July 2008 Resolved
rovide current Coast pilots and Light List.
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 8 July 2008
Resolution: Receipt for current pubs was faxed to MI.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 7 July 2008 Resolved
Provide new strobe light for Life-float.
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 8 July 2008
Resolution: Reciept was send to MI for the purchasing of new strobe.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 May 2008 Resolved
Properly install exhaust lagging on three Main Diesel Engines.
Due 12 June 2008
Resolved 7 July 2008
Resolution: New exhaust lagging was installed on engines.
Construction/Loadline › Hull › Transverse Frame
Issued 6 May 2008 Resolved
Remove all angel hair to good wood on overhead frames located in the engine room.
Due 12 June 2008
Resolved 7 July 2008
Resolution: Angel hair in engine room was remove.
Construction/Loadline › Hull › Side Shell
Issued 6 May 2008 Resolved
Submit repair proposal to include materials for several areas of wet rot observed in the forepeak void as marked. (Deck plating IWO bays 1, 2 & 3 on the starboard side). (Frame #1 at the strake)
Due 12 June 2008
Resolved 7 July 2008
Resolution: Area of rot was remove and replaced in kind to the satisfaction of attending MI.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 May 2008 Resolved
Make repairs to cracked weld IWO rial stanchion, main deck, starboard side, just outside the forward cabin door.
Due 12 June 2008
Resolved 7 July 2008
Resolution: Rail on starboard side was re-welded to the satisfaction of attending MI.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 19 April 2007 Resolved
Place guard around belt for fire pump on stbd main engine.
Condition: Placed in Improper Service
Due 25 April 2007
Resolved 27 April 2007
Resolution: Guard placed around belt.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 April 2007 Resolved
Replace missing lagging on 03 MDE exhaust.
Condition: Placed in Improper Service
Due 25 April 2007
Resolved 27 April 2007
Resolution: Lagging installed.
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 19 April 2007 Resolved
Replace retro-replective tape on lifejackets as needed.
Condition: Improper/Lack of Maintenance
Due 25 April 2007
Resolved 27 April 2007
Resolution: Reflective tape installed.
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 19 April 2007 Resolved
Provide 15 adult lifejackets onboard vessel.
Condition: Damaged By Earlier Event
Due 25 April 2007
Resolved 27 April 2007
Resolution: 15 lifejackets provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 April 2007 Resolved
Conduct satisfactory underway drills to satisfaction of attending USCG MI.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2007
Resolution: Satisfactory drills were conducted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 June 2006 Resolved
Provide proof of fire extinguishing service (for fixed CO2 and portable CO2) prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 12 June 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2006 Resolved
Contact FCC For current station license and radio sefety crtificate. Until proof of safety certificate provided, route is limited to 1000 feet from shore.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 12 June 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 June 2006 Resolved
Provide updated first aid kit.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 22 June 2006
Construction/Loadline › Structures › Superstructure
Issued 6 June 2006 Resolved
Make repairs to stbd side bridge window with crack.
Condition: Damaged By Earlier Event
Due 21 June 2006
Resolved 22 June 2006
Lifesaving › Hand Flares › Quantity
Issued 6 June 2006 Resolved
Provide 03 orange day smokes or 03 red flares.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 22 June 2006
Engineering › Freshwater System (cylinder head cooling) › Suction Strainer
Issued 6 June 2006 Resolved
Make repairs to leaking sea strainer on center engine.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 22 June 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 June 2006 Resolved
Replace torn lagging on each exhaust as needed in engine room.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 22 June 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 6 June 2006 Resolved
Properly house wires on port-forward side of center engine.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 22 June 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 June 2006 Resolved
PRovide donning placard for yoke-type PFDs.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 22 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2006 Resolved
Conduct housekeeping on wires in pilot house console. Properly terminate loose wires.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 22 June 2006
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 June 2006 Resolved
Conduct housekeeping in engine room bilges-clean oil from bilge/floor/etc/
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 22 June 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 June 2006 Resolved
Provide proof of DAPI program.
Condition: Improper/Lack of Maintenance
Due 21 June 2006
Resolved 12 June 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 3 May 2005 Resolved
Vessel needs to add crewmembers to the drug and alcohol program contract.
Condition: Unknown
Due 10 May 2005
Resolved 22 March 2006
Resolution: Spoke with rep, and was informed that crew mbr (missing from DAPI) was no longer employed with company.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 May 2005 Resolved
Provide COD for new owner, Sundance LLC.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2005
Resolved 6 May 2005
Resolution: Owner provided valid copy of COD to inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 3 May 2005 Resolved
Vessel needs to obtain a new FCC station License.
Condition: Unknown
Due 10 May 2005
Resolved 6 May 2005
Resolution: Owner provided valid copy of FCC Station License to inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2005 Resolved
Obtain charts for areas to be operated in.
Condition: Improper/Lack of Maintenance
Due 10 May 2005
Resolved 6 May 2005
Resolution: Charts were obtained for areas to be operated in.
Communications › Radio Communications › EPIRB
Issued 3 May 2005 Resolved
Replace expired hydrostatic release for EPIRB.
Condition: Improper/Lack of Maintenance
Due 10 May 2005
Resolved 2 June 2005
Resolution: Received receipt and written statement from the operator attesting to the proper replacement of the hydrostatic release.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 May 2005 Resolved
Obtain servicing certificates for fire extinguishers.
Condition: Improper/Lack of Maintenance
Due 10 May 2005
Resolved 6 May 2005
Resolution: Owner provided valid servicing certificates to inspector.
Lifesaving › Hand Flares › Expired
Issued 3 May 2005 Resolved
Replace day/night and smoke flares.
Condition: Improper/Lack of Maintenance
Due 10 May 2005
Resolved 2 June 2005
Resolution: Received receipt and written statement from the operator attesting to the proper replacement of the flares.
Fire Fighting › Firemans Outfit › Axe
Issued 3 May 2005 Resolved
Provide fire axe.
Condition: Improper/Lack of Maintenance
Due 10 May 2005
Resolved 6 May 2005
Resolution: Owner obainted fire axe.
Documentation › Manuals/Policy Documentation
Issued 9 March 2004 Resolved
Provide a proof of purchase of new navigaional rules.
Due 17 March 2004
Resolved 15 March 2004
Resolution: Showed reciept with back order number on it.
Lifesaving
Issued 9 March 2004 Resolved
Make permanent repairs to lifefloat netting (reconnect)
Due 17 March 2004
Resolved 15 March 2004
Lifesaving › Lifejacket/PFD (General)
Issued 9 March 2004 Resolved
Replace 11 adult and 0 child life jackets, include labeling, lights & reflective tape . Vessel is restricted to carry 114 adults and 13 children until NY03 is to the satisfaction of an attending marine inspector. LEGACY COMPONENT DESC: Condition
Due 17 March 2004
Resolved 15 March 2004
Resolution: Purchased additional lifejackets.
Lifesaving › Lifebuoys
Issued 9 March 2004 Resolved
Replace one lifering buoy with lifeline attached around the body , labelled with vsl name: prior to carrying passengers.
Due 9 March 2004
Resolved 15 March 2004
Resolution: Replaced life ring buoy and attached life line.
Electrical
Issued 9 March 2004 Resolved
Properly terminate or remove dead end wires in engine room ivo port generator.
Due 17 March 2004
Resolved 15 March 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 9 March 2004 Resolved
Make proper repairs to stbd shaft log.
Due 17 March 2004
Resolved 15 March 2004
Resolution: Tightened. shaft log.
Electrical
Issued 9 March 2004 Resolved
Properly terminate or remove dead end wires in lazerette.
Due 17 March 2004
Resolved 15 March 2004
Electrical › Electrical Distribution System (service)
Issued 9 March 2004 Resolved
Properly secure wires to overhead in lazerette. LEGACY COMPONENT DESC: Wiring
Due 17 March 2004
Resolved 15 March 2004
Pollution Prevention/Response › Prevention Equipment
Issued 9 March 2004 Resolved
Properly repair bilge high level alarms in spaces #1,2 & 5: prior to carrying passengers. LEGACY COMPONENT DESC: Bilge Monitor
Due 9 March 2004
Resolved 15 March 2004
Resolution: Proved proper operation of alarms.
Fire Fighting › Fire Main
Issued 22 December 2003 Resolved
DD-03 Install 2" distribution line past last orifices (2) in lazarette, and retest CO2 system piping to at least 600 PSI (provide testing certificate).
Due 30 January 2004
Resolved 2 January 2004
Resolution: Piping tested by 100 PSI in accordance with 46 CFR 181.410(d)(7)(iii)
Electrical › Electric Supply System (service)
Issued 14 April 2003 Resolved
Properly dead end wire in junction box in engine room. LEGACY COMPONENT DESC: Cable
Due 21 April 2003
Resolved 16 April 2003
Resolution: Wires secured in a junction box
Electrical › Lighting (emergency)
Issued 14 April 2003 Resolved
Emergency lighting inoperable during inspection, prove proper operation.
Due 21 April 2003
Resolved 16 April 2003
Resolution: Captain proved proper operation of E-Lighting
Electrical › Lighting (service)
Issued 14 April 2003 Resolved
flourescent light cover missing from light aft deck between heads. LEGACY COMPONENT DESC: Lighting Fixture
Due 21 April 2003
Resolved 16 April 2003
Resolution: Cover installed on flourescent fixture
Electrical › Electric Generation Source (service)
Issued 14 April 2003 Resolved
Repair/properly wire elctrical boxes in lazarette. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Due 21 April 2003
Resolved 22 April 2003
Resolution: Boxes rewired or secured as required.
Engineering › Fuel Oil Service System
Issued 14 April 2003 Resolved
Three independent fuel tanks not grounded. LEGACY COMPONENT DESC: Tank
Due 21 April 2003
Resolved 22 April 2003
Resolution: Tanks now grounded to engine bed on common ground.
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 April 2003 Resolved
Found one inservicable child life jacket, needs to be replaced. LEGACY COMPONENT DESC: Condition
Due 14 April 2003
Resolved 16 April 2003
Resolution: 01 new child life jacket with light put in service.
Navigation › Collision/Grounding Avoidance
Issued 14 April 2003 Resolved
Inoperable anchor light. LEGACY COMPONENT DESC: Navigation Lights
Due 14 April 2003
Resolved 22 April 2003
Resolution: Anchor light working as designed.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 April 2003 Resolved
All upper deck hand rails need to be tightened. LEGACY COMPONENT DESC: Deck Rail
Due 21 April 2003
Resolved 22 April 2003
Resolution: Upper deck rails fastened refastened as required.
Lifesaving
Issued 14 April 2003 Resolved
Lifefloat stored on main deck had torn floor netting
Due 21 April 2003
Resolved 16 April 2003
Resolution: Netting was addressed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 April 2003 Resolved
Vsl rep reported blown turbocharger on the stbd MDE LEGACY COMPONENT DESC: Turbocharger
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 16 April 2003
Resolution: Turbo was replaced in kind
Fire Fighting › Fire Pumps
Issued 14 April 2003 Resolved
Due to blown turbocharger on the stbd MDE, fire pump could not be tested.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 16 April 2003
Resolution: Operator proved proper operation of fire pump.
Engineering › Bilge Water Management System
Issued 14 April 2003 Resolved
Fixed bilge pump inop due to stbd MDE turbocharger problem
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 22 April 2003
Resolution: Fixed bilge system working as designed. Operation instruction posted IWO of valve manifold.
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 April 2003 Resolved
Replace expired meds in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 21 April 2003
Resolved 16 April 2003
Resolution: Expired medication replaced.
Electrical › Electric Generation Source (service)
Issued 14 April 2003 Resolved
Remove broken12V vent fan hanging from power cord in E/R IVO port MDE. LEGACY COMPONENT DESC: Conductor
Due 21 April 2003
Resolved 22 April 2003
Resolution: Fan removed from space.
Engineering › Shafting/Propeller Arrangements
Issued 14 April 2003 Resolved
Excessive water leak on stbd MDE shaft. LEGACY COMPONENT DESC: Propeller Shaft
Due 21 April 2003
Resolved 16 April 2003
Resolution: Shaft packing tightened
Communications › Radio Communications
Issued 14 April 2003 Resolved
Hydrostatic release expired on EPIRB. LEGACY COMPONENT DESC: EPIRB
Due 14 April 2003
Resolved 22 April 2003
Resolution: New EPIRB with new hydro-release installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 14 April 2003 Resolved
Vsl was short 1 B-II fire extinguisher in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2003
Resolved 16 April 2003
Resolution: 01 B-II extinguisher added.
Construction/Loadline › Penetrations
Issued 14 April 2003 Resolved
Properly seal watertight blkd penetrations in tank void and engine room. LEGACY COMPONENT DESC: Gasket
Due 21 April 2003
Resolved 22 April 2003
Resolution: Bulkhead properly sealed as required.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 April 2003 Resolved
water leaking from main exhaust pipe at point of water injection on center MDE LEGACY COMPONENT DESC: Piping (exhaust)
Due 21 April 2003
Resolved 16 April 2003
Resolution: Leak was addressed on the center MDE exhaust system.
Fire Fighting › Fixed Fire Detection System
Issued 1 April 2002 Resolved
Either remove grill from galley or equip it with a fixed fire extinguisher system in accordance with 46CFR181.400(d). Until system is equipped w/ new a fixed fire system, grill must not be used.
Due 30 April 2002
Resolved 24 October 2003
Resolution: Based on phone conversation with vessel crew, (crewmember stated grill removed from vessel) CG-835 removed and a special note added for next examination.
Fire Fighting › Means of Escape
Issued 1 April 2002 Resolved
Ensure escape hatch to second compartment is operational.
Due 30 April 2002
Resolved 23 April 2002
Resolution: Escape hatch to second compartment operational.
Engineering › Bilge Water Management System
Issued 18 March 2002 Resolved
Install positive stop closure valves to overboard discharge hoses for rule bilge pumps. LEGACY COMPONENT DESC: Valve
Due 31 March 2002
Resolved 23 April 2002
Resolution: Observed positive stop closure valves to overboard discharge hoses.
Lifesaving › Buoyant Apparatus
Issued 18 March 2002 Resolved
Reconfigure seapainter to lifefloat. LEGACY COMPONENT DESC: lifefloat
Due 31 March 2002
Resolved 1 April 2002
Resolution: Sea painter corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 March 2002 Resolved
Ensure waterlight line to life buoy ring is 3 to 6 feet long.
Due 31 March 2002
Resolved 1 April 2002
Resolution: Corrections observed.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 March 2002 Resolved
Replace broken pilot house glass. LEGACY COMPONENT DESC: Pilot [name withheld]
Due 31 March 2002
Resolved 1 April 2002
Resolution: Glass replaced.
Lifesaving
Issued 18 March 2002 Resolved
Replace yellow line to lifefloats with U/V protective line. LEGACY COMPONENT DESC: Lifefloat
Due 31 March 2002
Resolved 1 April 2002
Resolution: Line replaced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 March 2002 Resolved
Conduct a man overboard drill.
Due 31 March 2002
Resolved 1 April 2002
Resolution: Vsl conducted satisfactory man overboard drill.
Electrical
Issued 18 June 2001 Resolved
Provide specifications of new generator upon selection to confirm suitability of existing feed cables & power distribution and to determine if significant structural changes are required prior to installation._x001C_ Replacement required due to cracked block on stbd generator prime mover.
Condition: Unknown
Due 18 June 2001
Resolved 18 June 2001
Deck/Cargo
Issued 12 March 2001 Resolved
Renew pressure vessel for horn with one constructed to ASME U or ASME UM standard.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Electrical
Issued 12 March 2001 Resolved
Remove extension cord run through operating station and provide proper electrical supply source.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Electrical
Issued 12 March 2001 Resolved
Provide proper means of power distribution for portable bilge pump in the tank room.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Lifesaving
Issued 12 March 2001 Resolved
Provide public address system to interior spaces.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Documentation
Issued 12 March 2001 Resolved
Renew FCC Safety Certificate - vessel is restricted to operating not more than 1000 ft. from land until received.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Lifesaving
Issued 12 March 2001 Resolved
Correct stowage of Life Floats as discussed.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Navigation
Issued 12 March 2001 Resolved
Provide a 12" bell in accordance with the Nav Rules.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Fire Fighting
Issued 12 March 2001 Resolved
Tie in powered ventilation for engine room to CO2 shut down.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Electrical
Issued 12 March 2001 Resolved
Prove proper operation of the port generator.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Lifesaving
Issued 12 March 2001 Resolved
Provide a rescue platform/man-over-board recovery ladder.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Electrical
Issued 12 March 2001 Resolved
Remove multiple deadended wires from beneath the operating station.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Construction/Loadline
Issued 2 March 2000 Resolved
Scrape angel hair to good wood and repair damaged chine gussets (2nd & 3rd frame from engine room aft bulkhead) under stbd battery box. Complete at next non credit drydock as discussed.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Documentation
Issued 2 March 2000 Resolved
Provide and post emergency instruction list iaw 46 CFR 185.510.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Construction/Loadline
Issued 2 March 2000 Resolved
Scrape angel hair and make repairs under port battery box in engine room. Complete at next non credit drydock.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Construction/Loadline
Issued 2 March 2000 Resolved
Scrape to good wood angel hair in way of STBD shaft log access plate.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Navigation
Issued 2 March 2000 Resolved
Provide copy of current Coast Guard Light List.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Engineering
Issued 11 March 1999 Resolved
LABLE DIRECTION OF CLOSURE FOR EMERGENCY FUEL CUT-OFF
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 11 March 1999 Resolved
ENGINE ROOM: REMOVE DEADENDED WIRES LOCATED ON FWD BULKHEAD STBD SIDE, ABOVE SALT WATER WASHDOWN PUMP, BY OUTLET
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 11 March 1999 Resolved
ENGINE ROOM: REMOVE OR INSTALL CRIMP WIRE NUTS AND PLACE IN A JUNCTION BOXTHE DEAD ENDED WIRES LOCATED IN THE STBD AFT CORNER OF ENGINE ROOM (4 WIRESTOTAL)
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Accommodation/Occupational Safety
Issued 11 March 1999 Resolved
GALLEY: CLEAN STOVE EXHAUST FAN AND INSTALL A COVER ON SWITCH LOCATED BY FAN
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Construction/Loadline
Issued 11 March 1999 Resolved
CO2/FUEL TANK VOID: INSTALL A NEW SECTION OF HOSE BETWEEN BILGE LINE STRAINER AND MAIN BILGE LINE
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 11 March 1999 Resolved
ENGINE ROOM: INSTALL A COVER ON THE JUNCION BOX LOCATED ON THE OUTBOARD SIDE OF THE PORT ENGINE (AT THE FRONT)
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Engineering
Issued 11 March 1999 Resolved
ENGINE ROOM: REPLACE HOSE COMING FROM PORT GENERATOR MUFFLER TO THE OVERBOARD DISCHARGE FITTING, AND DOUBLE CLAMP
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 11 March 1999 Resolved
CREWS QTRS: INSTALL AN OUTLET COVER ON OUTLET LOCATED ON OVERHEAD ABOVE FREEZER
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 11 March 1999 Resolved
STENCIL NAME AND CAPACITY ON BOTTOM SIDE OF LIFE FLOATS, SECURE PADDLES USING STRING OR OTHER EASILY REMOVABLE METHOD, CURRENTLY USING WIRE TIES
Condition: Unknown
Due 2 April 1999
Resolved 2 April 1999
Fire Fighting
Issued 11 March 1999 Resolved
ENGINE ROOM: DOUBLE CLAMP HOSE ON STBD ENGINE FIRE PUMP SUCTION LINES
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 11 March 1999 Resolved
LIFE JACKETS: REPLACE (9) BATTERIES FOR LIGHTS ON JACKETS, REDUCED COASTWISE ROUTE TO 112 UNTIL CORRECTED AND INSPECTED BY A MI
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 11 March 1999 Resolved
BRIDGE: REMOVE VARIOUS DEAD ENDED WIRES ABOVE WINDOWS
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 11 March 1999 Resolved
BRIDGE: HEAD; INSTALL CRIMP WIRE NUTS ON OLD LIGHT FIXTURE CONNECTION
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Electrical
Issued 11 March 1999 Resolved
BRIDGE: INSTALL A COVER OVER THE LIGHT ABOVE THE HELM CHAIR
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 23 July 1998 Resolved
Properly attach waterlights to lifefloats.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Accommodation/Occupational Safety
Issued 23 July 1998 Resolved
ReFasten loose deck stanchions on pilothouse deck.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Electrical
Issued 23 July 1998 Resolved
Replace missing globe for light fixtue on pilothouse deck.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Accommodation/Occupational Safety
Issued 23 July 1998 Resolved
Properly repair broken stanchion for lifeline/railing at bow portside.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 6 April 1998 Resolved
REPAIR/REPLACE BROKEN/SPLIT LIFE FLOAT PADDLES (3)_x001C_
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Engineering
Issued 6 April 1998 Resolved
PROVE PROPER OPERATION OF EMERGENCY SHUTDOWN FOR MDE (PULL CABLE FROM P/H)_x001C_
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Documentation
Issued 6 April 1998 Resolved
POST DRUG ASSISTANCE PHONE NUMBERS FOR EMPLOYEES
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Documentation
Issued 6 April 1998 Resolved
PROVIDE A COMPLETE WASTE MANAGEMENT PLAN FOR DISPOSAL OF TRASH.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Lifesaving
Issued 6 April 1998 Resolved
PROVIDE A COMPLETE AND APPROVED FIRST AID KIT.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Lifesaving
Issued 6 April 1998 Resolved
SHOW PROOF OF EPIRB REGISTRATION WITH NOAA
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Construction/Loadline
Issued 6 April 1998 Resolved
REPAIR/REPLACE GASKET ON FWD COMPARTMENT HATCH
Condition: Unknown
Due 11 April 1998
Resolved 11 April 1998
Engineering
Issued 6 April 1998 Resolved
PROPERLY LABEL ALL FUEL SHUT-OFF VALVES. DUE TO NUMBER OF SHUT-OFFS (7) EACH ONE SHALL BE LABELED FOR PROPER IDENTIFICATION.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Construction/Loadline
Issued 14 January 1998 Resolved
OWNER/OPERATOR TO SECURE AFT HINGE ON STBD SIDE RECOVERY DOOR ON MAIN DECK.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Fire Fighting
Issued 14 January 1998 Resolved
OWNER OPERATOR TO SHOW PROOF THAT ALL FIRE EXTINGUISHERS ONBOARD HAVE BEEN TESTED. ALL FIRE EXTINGUISHERS LAST TESTED JAN 97.
Condition: Unknown
Due 31 January 1998
Resolved 14 January 1998
Accommodation/Occupational Safety
Issued 14 January 1998 Resolved
OWNER/OPERATOR TO TIGHTEN ALL HANDRAILS ON UPPER AND LOWER DECKS.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 18 March 1996 Resolved
RENEW RETROREFLECTIVE TAPE ON ALL LIFE FLOATS
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 18 March 1996 Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP DRIVEN OFF #1 MDE AT 60 PSI ON DISCHARGE SIDE OF PUMP PRIOR TO OPERATION OF VESSEL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 March 1996
Resolved 22 March 1996
Lifesaving
Issued 18 March 1996 Resolved
RENEW 3 ADULT TYPE I LIFEJACKETS TO REPLACE 3 ADULT TYPE I LIFEJACKETS WHICH WERE REJECTED. PASSENGER ALLOWANCE IS REDUCED BY 3 UNTIL LIFEJACKETSARE PROVIDED.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Navigation
Issued 18 March 1996 Resolved
PROVE PROPER OPERATION OF NAVIGATION LIGHTS IN ACCORDANCE WITH UL STANDARD 1104 AS PER 46 CFR 183.420.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 17 January 1996 Resolved
REMOVE OIL FROM ENGINE ROOM BILGES
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Lifesaving
Issued 17 January 1996 Resolved
INSTALL BELT GUARD ON STBD MDE.
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Electrical
Issued 17 January 1996 Resolved
REMOVE OR REPLACE AND HARD WIRE CORD OVER STBD GEN.
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Electrical
Issued 17 January 1996 Resolved
PROPERLY HANG WIRES TO PORT TRIM TABS IN LAZARETTE
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Engineering
Issued 17 January 1996 Resolved
REPAIR #2 & #3 PORT EXHAUST PIPESW AT COUPLING IN LAZARETTE
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Unknown
Issued 17 January 1996 Resolved
FILL ALL HOLES IN BOTH ENGINE ROOM BLKHDS.
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Electrical
Issued 17 January 1996 Resolved
REPLACE OR INSTALL ALL MISSING LIGHT GLOBES AND GUARDS THROUGHOUT VSL.
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Engineering
Issued 17 January 1996 Resolved
REPLACE BOILER EXHAUST ELBOW IN LAZARETTE.
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Unknown
Issued 17 January 1996 Resolved
REPAIR LAZARETTE VENT ON DECK.
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Unknown
Issued 17 January 1996 Resolved
PROVE PROPER OPERATION OF STBD MDE SEA SUCTION VALVE.
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Fire Fighting
Issued 17 January 1996 Resolved
SECURELY MOUNT PORT FIRE PUMP
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Lifesaving
Issued 17 January 1996 Resolved
INSTALL BELT GUARD ON PORT GENERATOR
Condition: Unknown
Due 31 March 1996
Resolved 21 March 1996
Unknown
Issued 18 March 1994 Resolved
REMOAVE HYDRAULIC FLUID FROM FORE PEAK AND MAKE READY FOR INSPECTION.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Unknown
Issued 18 March 1994 Resolved
REMOVE WATER FROM FORWARD STORAGE COMPARTMENT & MAKE READY FOR INSPECTION.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Lifesaving
Issued 18 March 1994 Resolved
UNTIL REPLACEMENT OF 25 ADULT LIFE PRESERVERS, TOTAL COASTWISE MANNING IS REDUCED TO 100 PERSONS ON BOARD.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Engineering
Issued 21 January 1994 Resolved
TIGHTEN ENG. BREATHER CLAMPS + REPLACE EXHAUST INSULATION JACKETS ON ALL ENG. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Navigation
Issued 21 January 1994 Resolved
REPLACE PORT RUDDER SHAFT KEY IN LAZZERETTE.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Navigation
Issued 21 January 1994 Resolved
SECURE PORT HYDRAULIC RAM BAR.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Construction/Loadline
Issued 21 January 1994 Resolved
PROVIDE NYCMI WITH SUBDIVISION CALCULATIONS. UNTIL THIS REQUIREMENT IS COMPLETE, THIS VESSEL IS RESTRICTED TO LESS THAN 50 PERSONS.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Construction/Loadline
Issued 21 January 1994 Resolved
LABEL BILGE MANIFOLD.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Engineering
Issued 21 January 1994 Resolved
SECURE STARBOARD ENGINE MOUNTING BOLTS.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Construction/Loadline
Issued 21 January 1994 Resolved
DOUBLE CLAMP ALL SALT WATER LINES.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Engineering
Issued 21 January 1994 Resolved
DOUBLE CLAMP ALL EXHAUST HOSES.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Navigation
Issued 10 April 1991 Resolved
PROVIDE MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Unknown
Issued 10 April 1991 Resolved
INSTALL PROPER FUEL VENT FLAME SCREENS FOR ALL FUEL TANK VENTS.
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Navigation
Issued 10 April 1991 Resolved
MAKE REPAIRS TO AFT PILOTHOUSE WINDOW TO MAKE WEATHERTIGHT.
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Fire Fighting
Issued 10 April 1991 Resolved
INSTALL AND PROVE PROPER OPERATION OF ELECTRIC FIRE PUMP PRESSURE GAUGE.
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Engineering
Issued 10 April 1991 Resolved
PROVE PROPER OPERATION OF CENTER MAIN DIESEL ENGINE.
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Engineering
Issued 10 April 1990 Resolved
MOUNT FUEL OIL FILTER HOUSING FOR BOILER FUEL SUPPLY ON STANCHION IN LAZARETTE.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Fire Fighting
Issued 10 April 1990 Resolved
RENEW PRESSURE GAGE FOR FIRE PUMP STARBOARD FORWARD BULKHEAD IN ENGINEROOM.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Engineering
Issued 10 April 1990 Resolved
INSTALL METAL INSULATION COVERS ON HEATING BOILER (2).
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Electrical
Issued 10 April 1990 Resolved
MOUNT COVER PLATES TO ELECTRICAL JUNCTION AND SWITCH BOXES ABOVE BOILER.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Engineering
Issued 10 April 1990 Resolved
INSTALL GUARDS FOR BELT DRIVEN MACHINERY STARBOARD MAIN ENGINE (2) AND STARBOARD SHIP SERVICE GENERATOR (1).
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Construction/Loadline
Issued 10 April 1990 Resolved
INSTALL VALVE HANDLE OR RENEW VALVE FOR SALT WATER TO MSD IN LAZARETTE.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Construction/Loadline
Issued 10 April 1990 Resolved
CAULK (2) HOLES IN BULKHEAD OF ENGINE ROOM LAZARETTE STARBOARD OUTBOARD ANDONE MIDSHIPS AT OVERHEAD FOR WIRE WAY AND FUEL LINE.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Engineering
Issued 10 April 1990 Resolved
REMOVE CARPET FROM ENGINE ROOM DECK PLATES.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Construction/Loadline
Issued 3 January 1990 Resolved
INSTALL BILGE SUCTION STRAINERS WHERE MISSING.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Engineering
Issued 3 January 1990 Resolved
INSTALL FLAME SCREENS TO FUEL TANK VENTS WHERE MISSING.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Electrical
Issued 3 January 1990 Resolved
REPLACE NON-USCG APPROVED FLEXIBLE FUEL LINES ON BOTH SERVICE GENERATORS WITH USCG APPROVED TYPE.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Documentation
Issued 3 January 1990 Resolved
PROVIDE EITHER EVIDENCE OF INCLINING TEST OR STABILITY CALCULATIONS BY A NAVAL ARCHITECT TO SHOW ACCEPTABLE STABILITY PARAMETERS FOLLOWING REMOVAL OF CENTER MAIN DIESEL ENGINE.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Engineering
Issued 19 April 1989 Resolved
INSTALL BILGE SUCTION STRAINER WHERE MISSING.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Engineering
Issued 19 April 1989 Resolved
INSTALL FLAME SCREENS FUEL TANK VENTS WHERE MISSING.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Electrical
Issued 19 April 1989 Resolved
INSTALL BULB IN 32 VOC LIGHT FORWARD.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Engineering
Issued 19 April 1989 Resolved
CAP OR PLUG ENGINE EXHAUSTS FROM REMOVED CENTERLINE ENGINE WHERE THEY PASS TO STEERING COMPARTMENT.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Lifesaving
Issued 19 April 1989 Resolved
LABLE FIRE AXE AND LIFE FLOAT PADDLES WITH VESSELS NAME WHERE MISSING.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Fire Fighting
Issued 19 April 1989 Resolved
PROVIDE DISCHARGE HOSE FOR FIREFIGHTING FOR HAND FIRE AND BILGE PUMP.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Navigation
Issued 19 April 1989 Resolved
PROVIDE CURRENT TIDE TABLE AND COAST PILOT.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Documentation
Issued 19 April 1989 Resolved
POST EMERGENCY CHECKLIST.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Lifesaving
Issued 19 April 1989 Resolved
REPAIR SNAPS ON SIX ADULT AND ONE CHILD PFD REPLACE MISSING CHILD PFD.
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Lifesaving
Issued 19 April 1988 Resolved
SECURE (2) TWO PADDLES PER LIFE FLOAT TO THE INTERIOR OF LIFE FLOAT, ON ALL(3) THREE LIFE FLOATS.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Navigation
Issued 19 April 1988 Resolved
REPLACE ALL NAVIGATIONAL RUNNING LIGHTS, WITH UL MARINE APPROVED TYPE.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Electrical
Issued 19 April 1988 Resolved
PROVIDE AN OPERATIONAL UNDER LOAD TEST OF THE PORT SERVICE GENERATOR, PRESENTLY INOPERABLE.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Engineering
Issued 19 April 1988 Resolved
PROVIDE AN OPERATIONAL TEST OF THE CENTER MAIN DIESEL ENGINE, PRESENTLY INOPERABLE.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Engineering
Issued 19 April 1988 Resolved
REPLACE (1) ONE NON-CG APPROVED FLEXIBLE FUEL LINE ON SERVICE GENERATOR, WITH CG APPROVED TYPE.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Lifesaving
Issued 19 April 1988 Resolved
REPLACE ALL NETTING IN THE FLOOR OF (3) THREE LIFE FLOATS, WHERE DETERIORATED. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS FOR HIRE, UNTILTHIS ITEM IS CORRECTED.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Fire Fighting
Issued 19 April 1988 Resolved
PROVIDE AN OPERATIONAL TEST OF THE STARBOARD MAIN DIESEL ENGINE'S BELT DRIVEN FUEL PUMP, WHICH IS PRESENTLY INOPERABLE. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS FOR HIRE, UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Fire Fighting
Issued 19 April 1988 Resolved
PROVIDE (1) ONE B-II PORTABLE FIRE EXTINGUISHER WHICH WEIGHED IS (2) TWO POUNDS LIGHT. VESSEL RESTRICTED FROM CARRYING PASSENGERS FOR HIRE UNTIL ITEM IS CORRECTED.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Documentation
Issued 6 April 1987 Resolved
PROVIDE VALID STICKER FOR VESSEL'S DOCUMENT, PRESENT STICKER EXPIRED 3/86.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Engineering
Issued 6 April 1987 Resolved
REPLACE OR CONVERT PRESENT RACOR FUEL FILTERS 3 EACH, WITH COAST GUARD APPROVED FUEL FILTERS.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Engineering
Issued 6 April 1987 Resolved
REPLACE 3 NON-COAST GUARD APPROVED FLEX FUEL LINES WITH COAST GUARD APPROVED ON AUXILIARY GENERATOR.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Electrical
Issued 21 March 1986 Resolved
PROVIDE BATTERY BOX COVERS ON 3 - BATTERY BOXES IN ENGINE SPACE, WHERE MISSING.
Condition: Unknown
Due 21 March 1986
Resolved 21 March 1986
Lifesaving
Issued 21 March 1986 Resolved
REPLACE LINES ON INSIDE PLATFORMS OF 3 - BA'S, WHERE DETERIORATED.
Condition: Unknown
Due 21 March 1986
Resolved 21 March 1986
Lifesaving
Issued 21 March 1986 Resolved
REPLACE OR REPAIR GRAB LINES ON 3 - RING BUOY'S, WHERE DETERIORATED.
Condition: Unknown
Due 21 March 1986
Resolved 21 March 1986
Lifesaving
Issued 21 March 1986 Resolved
PROVIDE OPERATIONAL TEST OF 1 WATERLIGHT, PRESENTLY OOC.
Condition: Unknown
Due 21 March 1986
Resolved 21 March 1986
Engineering
Issued 19 March 1985 Resolved
PROVIDE FOR FIRESIDE EXAMINATION UNDER WORKING PRESSURE HYDROSTATIC TEST OFCARLIN OIL FIRED HEATING BOILER.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Navigation
Issued 19 March 1985 Resolved
PROVE THAT VESSEL'S WHISTLE AIR TANK MANUFACTURED BY SEARS, IS BUILT TO THEREQUIREMENTS IN SECTION VIII DIVISION 1 OF THE ASME CODE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Fire Fighting
Issued 19 March 1985 Resolved
PROVIDE FOR PROPER SERVICING OF BII DRY CHEMICAL EXTINGUISHER LOCATED STARBOARD SIDE OF ENGINE ROOM.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Fire Fighting
Issued 19 March 1985 Resolved
PROVIDE ONE FIRE AXE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985

Casualty record · 2

19 April 2011Routine · role: Involved in a Marine Casualty · activity 4137656
23 May 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 4071413
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CAPTREE STAR III (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.