← All vessels
STARLIGHT
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named STARLIGHT
STARLIGHT is a 1978 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1985, most recently in May 2026, along with 237 deficiencies and 2 casualty investigations in 2011.
Records from 1985 to 2026. Most recent: inspection, 21 May 2026.
- Built
- 1978
- Last inspected
- 21 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 237 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2011
Identity
593373
WDP5951
49685
Flag
UNITED STATES
368368060
Maury page id
psix-49685
Inspections, by type
…with no type recorded6
Years with a record
39 calendar years (1985–2026)
The 86 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)68.7 ft × 22.1 ft × 6.7 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1978
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCAPE MAY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP5951MMSI 368368060 · active · compulsorily equipped · granted 16 May 2024, expires 16 May 2034
WDM3724MMSI 367442940 · cancelled · compulsorily equipped · granted 20 May 2021, cancelled 20 April 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDD6424MMSI 367172790 · expired · compulsorily equipped · granted 13 March 2007, cancelled 13 May 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDC5451MMSI 367041290 · expired · compulsorily equipped · granted 11 May 2005, cancelled 11 July 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCQ7525MMSI not assigned · expired · voluntarily equipped · granted 10 April 1995, cancelled 11 June 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 86
21 May 2026
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8367211
3 September 2025
Annual Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8226219
30 October 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8026929
9 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8015543
16 May 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7912484
3 April 2023
Annual Inspection · In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7661549
16 March 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7652215
10 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7634696
15 April 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7446122
29 September 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7322355
29 April 2021
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7185852
23 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7161401
18 June 2020
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6924631
16 October 2019
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6820855
4 June 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6688792
22 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6384974
13 October 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6282091
9 May 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6199715
6 June 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5899248
20 April 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5858321
4 June 2014
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4879119
6 March 2014
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4812282
10 January 2012
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4222146
22 July 2011
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4096509
25 October 2010
Inclining Experiment
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3877084
11 January 2010
Deficiency Check · COI Inspection · Administrative Inspection · Deadweight Survey · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3662589
23 September 2008
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3331043
20 September 2008
Type not recorded
No type recorded · Station Sandy Hook · USCG Northeast District (CGD-NE) · Activity 3330011
7 July 2008
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3267538
6 May 2008
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3199796
19 April 2007
MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2911031
6 June 2006
Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2672106
2 May 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2638390
3 May 2005
Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2348057
9 March 2004
Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2020778
22 December 2003
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1968105
14 April 2003
Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1773253
20 March 2002
MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1495053
3 December 2001
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1407042
24 August 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073430
18 June 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1070653
12 March 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384702
19 October 2000
Type not recorded
No type recorded · Station Sandy Hook · USCG Northeast District (CGD-NE) · Activity 1514125
2 March 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1436339
28 December 1999
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1046830
11 March 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384061
25 August 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1131875
23 July 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 795454
21 July 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1129722
6 April 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1125690
14 January 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1107746
14 January 1998
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1461008
13 March 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1095688
9 May 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085506
18 March 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077617
18 March 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1092862
17 January 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186350
21 March 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135228
12 December 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1144104
5 April 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857054
18 March 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857202
3 March 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857723
21 January 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853178
18 March 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836207
3 February 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135719
9 April 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 960904
9 April 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254453
3 July 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941194
22 May 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934153
10 April 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219631
9 January 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1240887
24 August 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219243
8 May 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226483
10 April 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218120
3 January 1990
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227254
19 April 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032136
2 March 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1196095
1 July 1988
Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340668
19 April 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039717
13 April 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343979
13 April 1988
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1344243
6 April 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329780
29 April 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000551
21 March 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1305494
9 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 980065
19 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289497
Deficiency record · 237
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 September 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests.
Provide service report for Fixed CO2 system and portable extinguishers.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 September 2025
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
The EPIRB hydrostatic release was expired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 September 2025
Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. For fire hydrants located on open decks or cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or cargo handling operations, respectively. Hoses so removed must be stored in nearby accessible locations.
Replace fire hose.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 September 2025
Resolved
The means used to attach the float-free link to the vessel must have a breaking strength of at least the breaking strength of the painter.
Life floats were found fastened to the uppermost deck by means of the painter housing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2025
Resolved
Each lifejacket must be approved under approval series in subparts 160.002, 160.005, 160.055, 160.115, 160.176, or 160.255, or other standard specified by the Commandant.
MI found 7 life jackets that were either not approved for small passenger vessel service or damaged to the point of being unserviceable.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 September 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light.
All life float paddles were cracking and unserviceable.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 3 September 2025
Resolved
Use of a Coast Guard type-approved AIS Class B device in lieu of an AIS Class A device is permissible on the following vessels if they are not subject to pilotage by other than the vessel Master or crew: Vessels identified in paragraph (b)(1)(i) of this section that are certificated to carry less than 150 passengers.
Vessel does not have AIS, Owner/Operator instructed to install Class "B" AIS transponder.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 September 2025
Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section:
Discharge hose on CO2 has wasted fitting. Fitting to be replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 September 2025
Resolved
A collision bulkhead must not be fitted with any type of penetration or opening except penetrations may be made if they are located as high and as far inboard as practicable and they have a means to make them watertight.
The collision bulkhead had two vent penetrations that were not watertight in way of the most outboard locations of both the port and starboard-most reaches of the bulkhead.46 CFR 179.310(a)(2)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 September 2025
Resolved
No person may operate a vessel to which this part applies unless they have on board in hard copy or digital form a valid certificate of number or temporary certificate for that vessel issued by the issuing authority in the State in which the vessel is principally operated.
The vessel does not have a valid certificate of number for the state of Florida. 33CFR173.21(a)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Hydraulic lines serving the anchor windlass were cracked. 46 CFR182.720(e)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2025
Resolved
Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose and must comply with SAE J-1475. Hose end fittings serving the hydraulic lines for the anchor windlass were unsuitably corroded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2025
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided at such locations where persons or equipment might come in contact with an exhaust pipe.
The port side main engine exhaust lagging was missing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 September 2025
Resolved
Water for cooling the exhaust pipe, must be injected into the exhaust system as near to the engine manifold as practicable, and that water must pass through the entire length of the exhaust pipe.
Center main engine lagging was leaking raw cooling water between its injection point and the exhaust terminus as evidenced by the accumulation of salt in the engine room below the exhaust pipe.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 September 2025
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead.
Bulkhead in lazarette to engine room has penetrations that need to be watertight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 September 2025
Resolved
A hatch exposed to the weather must be watertight.
Forward hatch for collision bulkhead needs to be fully operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 September 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942.
Piping on port engine water pump to heat exchanger has a patch. Piping must be approved type or replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 May 2024
Resolved
For fixed gas fire extinguishing system, The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel had a custom fixed co2 system that had not been serviced since March 2023. Service the fixed C02 system to the satisfaction of the attending marine inspector. 46CFR810(b)2
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2024
Resolved
Fire hose shall have a nozzle that has a 1/2 inch solid stream Orifice or a combination nozzle. Vessel did not have a nozzle attached to fire hose. Install nozzle on the fire hose to the satisfaction of the attending marine inspector. 46CFR181.15-10(c)(1) (Old "T")
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 May 2024
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Vessel did not have a pressure gauge installed. Install pressure gauge at the pump outlet to the satisfaction of the attending marine inspector. 46CFR182.520
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 16 May 2024
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Vessel did not have the anchor fitted to the vessel for use. Install anchor. 46CFR184.300
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2024
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead. Valve was not operable. Replace valve in forward compartment to the satisfaction of the attending marine inspector. 46CFR181.10-1c (Old "T")
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel had 17 life jackets that needed retro reflective tape replaced and two life jackets were condemned. Repair the 17 life jackets and replace the two condemned life jackets. 46cfr176.808c
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 May 2024
Resolved
Unless normal use of the radiotelephone installation demonstrates that the equipment is in proper operating condition. VHF radio did not have the MSSI number programmed in. Install MSSI number. 47CFR80.931
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2024
Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Install covers on batteries. 46CFR183.354(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2024
Resolved
Receptacle outlets of the type providing a grounded pole or a specific direct current polarity must be of a configuration that will not permit improper connection. Install outlet cover on Fwd Starboard bulkhead. 183.220(c)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 16 May 2024
Resolved
Operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Blank off overboard discharge. 33CFR1597(b)
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 May 2024
Resolved
Double hose clamping is required where practicable in systems and application where flexible hoses are permitted to be clamped. Install double hose clamps. 46CFR182.410d(1)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 April 2023
Resolved
Spaces containing propulsion machinery are required to to be equipped with a fire detection system. Heat detection system in engine room was no longer operable.
46 CFR 181.405 (disregard below)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2023
Resolved
All equipment including switches shall be of a type designed for the potential involved and so identified. The generator selector switches in the engine room require the knobs designed for properly turning switches.
46 CFR 183.10-20
(OLD T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2023
Resolved
All machinery must be maintained in such a manner as to afford adequate protection against failure. Spring on the STBD engine shutoff assembly was being held by a zip tie and needs to be replaced with a new part.
46 CFR 182.01-5
(OLD T)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2023
Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose of its intended service. Grab lines on several life floats and the basket on one were deteriorated.
46 CFR 180.175
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2023
Resolved
A life preserver shall not be appreciably deteriorated. 10 life jackets on the upper deck were found to be significantly deteriorated and must be replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 April 2021
Resolved
46 CFR 182.20-25
Sounding gage for independent fuel tanks were not of a heat resistant material and did not have a means to automatically close.
Due prior to next credit dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2021
Resolved
46 CFR 183.05-20 Batteries do not have covers/ protection from objects falling on terminals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2021
Resolved
46 CFR 177.35-15 Pullies on center and port side main engines do not have guards.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 June 2020
Resolved
Life-floats were left detached from weak link after rep serviced. properly re-connect.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 June 2020
Resolved
Water light for one of the life floats was not properly secured repair or replace light.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 June 2019
Resolved
Replace battery and hydrostatic release prior to operating more than 3 miles from shore with passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2019
Resolved
replace ring buoy
Engineering › Bilge Water Management System › Pump
Issued 8 June 2016
Resolved
Repair clutch for stbd pump (for bilge piping system)
Communications › Radio Communications › VHF Radiotelephone
Issued 8 June 2016
Resolved
Program MMSI# into VHF/DSC capable radio per MSIB.
Documentation › Certificates/Documents › Stability Letter
Issued 8 June 2016
Resolved
Post stability letter with COI in operating station.
Navigation › Piloting/Steering › Marine Charts
Issued 8 June 2016
Resolved
Provide updated chart for area of operation.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 June 2016
Resolved
Label, and put retro on RLB's on aft and port of operating station.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 June 2014
Resolved
Make line for electric Light on ring buoy 3-6 feet.
Engineering › Bilge Water Management System › Manifold
Issued 4 June 2014
Resolved
Label Bilge Manifold.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 June 2014
Resolved
Replace the battery in light prior to operating greater then LBC route.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 June 2014
Resolved
Provide (05) adult life jackets. Passenger count reduced by 5 until provided.
Construction/Loadline › Hull › Transverse Frame
Issued 6 March 2014
Resolved
Inspect and refasten interior frames in lazarette.
Stability › Watertight Integrity › General
Issued 6 March 2014
Resolved
Make all bulkheads watertight. Bulkheads throughout were not water tight.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 July 2008
Resolved
rovide current Coast pilots and Light List.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 7 July 2008
Resolved
Provide new strobe light for Life-float.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 May 2008
Resolved
Properly install exhaust lagging on three Main Diesel Engines.
Construction/Loadline › Hull › Transverse Frame
Issued 6 May 2008
Resolved
Remove all angel hair to good wood on overhead frames located in the engine room.
Construction/Loadline › Hull › Side Shell
Issued 6 May 2008
Resolved
Submit repair proposal to include materials for several areas of wet rot observed in the forepeak void as marked.
(Deck plating IWO bays 1, 2 & 3 on the starboard side).
(Frame #1 at the strake)
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 May 2008
Resolved
Make repairs to cracked weld IWO rial stanchion, main deck, starboard side, just outside the forward cabin door.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 19 April 2007
Resolved
Place guard around belt for fire pump on stbd main engine.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 April 2007
Resolved
Replace missing lagging on 03 MDE exhaust.
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 19 April 2007
Resolved
Replace retro-replective tape on lifejackets as needed.
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 19 April 2007
Resolved
Provide 15 adult lifejackets onboard vessel.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 April 2007
Resolved
Conduct satisfactory underway drills to satisfaction of attending USCG MI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 June 2006
Resolved
Provide proof of fire extinguishing service (for fixed CO2 and portable CO2) prior to carrying passengers.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2006
Resolved
Contact FCC For current station license and radio sefety crtificate. Until proof of safety certificate provided, route is limited to 1000 feet from shore.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 June 2006
Resolved
Provide updated first aid kit.
Construction/Loadline › Structures › Superstructure
Issued 6 June 2006
Resolved
Make repairs to stbd side bridge window with crack.
Lifesaving › Hand Flares › Quantity
Issued 6 June 2006
Resolved
Provide 03 orange day smokes or 03 red flares.
Engineering › Freshwater System (cylinder head cooling) › Suction Strainer
Issued 6 June 2006
Resolved
Make repairs to leaking sea strainer on center engine.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 June 2006
Resolved
Replace torn lagging on each exhaust as needed in engine room.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 6 June 2006
Resolved
Properly house wires on port-forward side of center engine.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 June 2006
Resolved
PRovide donning placard for yoke-type PFDs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2006
Resolved
Conduct housekeeping on wires in pilot house console. Properly terminate loose wires.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 June 2006
Resolved
Conduct housekeeping in engine room bilges-clean oil from bilge/floor/etc/
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 June 2006
Resolved
Provide proof of DAPI program.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 3 May 2005
Resolved
Vessel needs to add crewmembers to the drug and alcohol program contract.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 May 2005
Resolved
Provide COD for new owner, Sundance LLC.
Documentation › Certificates/Documents › FCC SSL
Issued 3 May 2005
Resolved
Vessel needs to obtain a new FCC station License.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2005
Resolved
Obtain charts for areas to be operated in.
Communications › Radio Communications › EPIRB
Issued 3 May 2005
Resolved
Replace expired hydrostatic release for EPIRB.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 May 2005
Resolved
Obtain servicing certificates for fire extinguishers.
Lifesaving › Hand Flares › Expired
Issued 3 May 2005
Resolved
Replace day/night and smoke flares.
Fire Fighting › Firemans Outfit › Axe
Issued 3 May 2005
Resolved
Provide fire axe.
Documentation › Manuals/Policy Documentation
Issued 9 March 2004
Resolved
Provide a proof of purchase of new navigaional rules.
Lifesaving
Issued 9 March 2004
Resolved
Make permanent repairs to lifefloat netting (reconnect)
Lifesaving › Lifejacket/PFD (General)
Issued 9 March 2004
Resolved
Replace 11 adult and 0 child life jackets, include labeling, lights & reflective tape . Vessel is restricted to carry 114 adults and 13 children until NY03 is to the satisfaction of an attending marine inspector. LEGACY COMPONENT DESC: Condition
Lifesaving › Lifebuoys
Issued 9 March 2004
Resolved
Replace one lifering buoy with lifeline attached around the body , labelled with vsl name: prior to carrying passengers.
Electrical
Issued 9 March 2004
Resolved
Properly terminate or remove dead end wires in engine room ivo port generator.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 9 March 2004
Resolved
Make proper repairs to stbd shaft log.
Electrical
Issued 9 March 2004
Resolved
Properly terminate or remove dead end wires in lazerette.
Electrical › Electrical Distribution System (service)
Issued 9 March 2004
Resolved
Properly secure wires to overhead in lazerette. LEGACY COMPONENT DESC: Wiring
Pollution Prevention/Response › Prevention Equipment
Issued 9 March 2004
Resolved
Properly repair bilge high level alarms in spaces #1,2 & 5: prior to carrying passengers. LEGACY COMPONENT DESC: Bilge Monitor
Fire Fighting › Fire Main
Issued 22 December 2003
Resolved
DD-03 Install 2" distribution line past last orifices (2) in lazarette, and retest CO2 system piping to at least 600 PSI (provide testing certificate).
Electrical › Electric Supply System (service)
Issued 14 April 2003
Resolved
Properly dead end wire in junction box in engine room. LEGACY COMPONENT DESC: Cable
Electrical › Lighting (emergency)
Issued 14 April 2003
Resolved
Emergency lighting inoperable during inspection, prove proper operation.
Electrical › Lighting (service)
Issued 14 April 2003
Resolved
flourescent light cover missing from light aft deck between heads. LEGACY COMPONENT DESC: Lighting Fixture
Electrical › Electric Generation Source (service)
Issued 14 April 2003
Resolved
Repair/properly wire elctrical boxes in lazarette. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Engineering › Fuel Oil Service System
Issued 14 April 2003
Resolved
Three independent fuel tanks not grounded. LEGACY COMPONENT DESC: Tank
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 April 2003
Resolved
Found one inservicable child life jacket, needs to be replaced. LEGACY COMPONENT DESC: Condition
Navigation › Collision/Grounding Avoidance
Issued 14 April 2003
Resolved
Inoperable anchor light. LEGACY COMPONENT DESC: Navigation Lights
Accommodation/Occupational Safety › Occupational Safety
Issued 14 April 2003
Resolved
All upper deck hand rails need to be tightened. LEGACY COMPONENT DESC: Deck Rail
Lifesaving
Issued 14 April 2003
Resolved
Lifefloat stored on main deck had torn floor netting
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 April 2003
Resolved
Vsl rep reported blown turbocharger on the stbd MDE LEGACY COMPONENT DESC: Turbocharger
Fire Fighting › Fire Pumps
Issued 14 April 2003
Resolved
Due to blown turbocharger on the stbd MDE, fire pump could not be tested.
Engineering › Bilge Water Management System
Issued 14 April 2003
Resolved
Fixed bilge pump inop due to stbd MDE turbocharger problem
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 April 2003
Resolved
Replace expired meds in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Electrical › Electric Generation Source (service)
Issued 14 April 2003
Resolved
Remove broken12V vent fan hanging from power cord in E/R IVO port MDE. LEGACY COMPONENT DESC: Conductor
Engineering › Shafting/Propeller Arrangements
Issued 14 April 2003
Resolved
Excessive water leak on stbd MDE shaft. LEGACY COMPONENT DESC: Propeller Shaft
Communications › Radio Communications
Issued 14 April 2003
Resolved
Hydrostatic release expired on EPIRB. LEGACY COMPONENT DESC: EPIRB
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 14 April 2003
Resolved
Vsl was short 1 B-II fire extinguisher in engine room.
Construction/Loadline › Penetrations
Issued 14 April 2003
Resolved
Properly seal watertight blkd penetrations in tank void and engine room. LEGACY COMPONENT DESC: Gasket
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 April 2003
Resolved
water leaking from main exhaust pipe at point of water injection on center MDE LEGACY COMPONENT DESC: Piping (exhaust)
Fire Fighting › Fixed Fire Detection System
Issued 1 April 2002
Resolved
Either remove grill from galley or equip it with a fixed fire extinguisher system in accordance with 46CFR181.400(d). Until system is equipped w/ new a fixed fire system, grill must not be used.
Fire Fighting › Means of Escape
Issued 1 April 2002
Resolved
Ensure escape hatch to second compartment is operational.
Engineering › Bilge Water Management System
Issued 18 March 2002
Resolved
Install positive stop closure valves to overboard discharge hoses for rule bilge pumps. LEGACY COMPONENT DESC: Valve
Lifesaving › Buoyant Apparatus
Issued 18 March 2002
Resolved
Reconfigure seapainter to lifefloat. LEGACY COMPONENT DESC: lifefloat
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 March 2002
Resolved
Ensure waterlight line to life buoy ring is 3 to 6 feet long.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 March 2002
Resolved
Replace broken pilot house glass. LEGACY COMPONENT DESC: Pilot [name withheld]
Lifesaving
Issued 18 March 2002
Resolved
Replace yellow line to lifefloats with U/V protective line. LEGACY COMPONENT DESC: Lifefloat
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 March 2002
Resolved
Conduct a man overboard drill.
Electrical
Issued 18 June 2001
Resolved
Provide specifications of new generator upon selection to confirm suitability of existing feed cables & power distribution and to determine if significant structural changes are required prior to installation._x001C_ Replacement required due to cracked block on stbd generator prime mover.
Deck/Cargo
Issued 12 March 2001
Resolved
Renew pressure vessel for horn with one constructed to ASME U or ASME UM standard.
Electrical
Issued 12 March 2001
Resolved
Remove extension cord run through operating station and provide proper electrical supply source.
Electrical
Issued 12 March 2001
Resolved
Provide proper means of power distribution for portable bilge pump in the tank room.
Lifesaving
Issued 12 March 2001
Resolved
Provide public address system to interior spaces.
Documentation
Issued 12 March 2001
Resolved
Renew FCC Safety Certificate - vessel is restricted to operating not more than 1000 ft. from land until received.
Lifesaving
Issued 12 March 2001
Resolved
Correct stowage of Life Floats as discussed.
Navigation
Issued 12 March 2001
Resolved
Provide a 12" bell in accordance with the Nav Rules.
Fire Fighting
Issued 12 March 2001
Resolved
Tie in powered ventilation for engine room to CO2 shut down.
Electrical
Issued 12 March 2001
Resolved
Prove proper operation of the port generator.
Lifesaving
Issued 12 March 2001
Resolved
Provide a rescue platform/man-over-board recovery ladder.
Electrical
Issued 12 March 2001
Resolved
Remove multiple deadended wires from beneath the operating station.
Construction/Loadline
Issued 2 March 2000
Resolved
Scrape angel hair to good wood and repair damaged chine gussets (2nd & 3rd frame from engine room aft bulkhead) under stbd battery box. Complete at next non credit drydock as discussed.
Documentation
Issued 2 March 2000
Resolved
Provide and post emergency instruction list iaw 46 CFR 185.510.
Construction/Loadline
Issued 2 March 2000
Resolved
Scrape angel hair and make repairs under port battery box in engine room. Complete at next non credit drydock.
Construction/Loadline
Issued 2 March 2000
Resolved
Scrape to good wood angel hair in way of STBD shaft log access plate.
Navigation
Issued 2 March 2000
Resolved
Provide copy of current Coast Guard Light List.
Engineering
Issued 11 March 1999
Resolved
LABLE DIRECTION OF CLOSURE FOR EMERGENCY FUEL CUT-OFF
Electrical
Issued 11 March 1999
Resolved
ENGINE ROOM: REMOVE DEADENDED WIRES LOCATED ON FWD BULKHEAD STBD SIDE, ABOVE SALT WATER WASHDOWN PUMP, BY OUTLET
Electrical
Issued 11 March 1999
Resolved
ENGINE ROOM: REMOVE OR INSTALL CRIMP WIRE NUTS AND PLACE IN A JUNCTION BOXTHE DEAD ENDED WIRES LOCATED IN THE STBD AFT CORNER OF ENGINE ROOM (4 WIRESTOTAL)
Accommodation/Occupational Safety
Issued 11 March 1999
Resolved
GALLEY: CLEAN STOVE EXHAUST FAN AND INSTALL A COVER ON SWITCH LOCATED BY FAN
Construction/Loadline
Issued 11 March 1999
Resolved
CO2/FUEL TANK VOID: INSTALL A NEW SECTION OF HOSE BETWEEN BILGE LINE STRAINER AND MAIN BILGE LINE
Electrical
Issued 11 March 1999
Resolved
ENGINE ROOM: INSTALL A COVER ON THE JUNCION BOX LOCATED ON THE OUTBOARD SIDE OF THE PORT ENGINE (AT THE FRONT)
Engineering
Issued 11 March 1999
Resolved
ENGINE ROOM: REPLACE HOSE COMING FROM PORT GENERATOR MUFFLER TO THE OVERBOARD DISCHARGE FITTING, AND DOUBLE CLAMP
Electrical
Issued 11 March 1999
Resolved
CREWS QTRS: INSTALL AN OUTLET COVER ON OUTLET LOCATED ON OVERHEAD ABOVE FREEZER
Lifesaving
Issued 11 March 1999
Resolved
STENCIL NAME AND CAPACITY ON BOTTOM SIDE OF LIFE FLOATS, SECURE PADDLES USING STRING OR OTHER EASILY REMOVABLE METHOD, CURRENTLY USING WIRE TIES
Fire Fighting
Issued 11 March 1999
Resolved
ENGINE ROOM: DOUBLE CLAMP HOSE ON STBD ENGINE FIRE PUMP SUCTION LINES
Lifesaving
Issued 11 March 1999
Resolved
LIFE JACKETS: REPLACE (9) BATTERIES FOR LIGHTS ON JACKETS, REDUCED COASTWISE ROUTE TO 112 UNTIL CORRECTED AND INSPECTED BY A MI
Electrical
Issued 11 March 1999
Resolved
BRIDGE: REMOVE VARIOUS DEAD ENDED WIRES ABOVE WINDOWS
Electrical
Issued 11 March 1999
Resolved
BRIDGE: HEAD; INSTALL CRIMP WIRE NUTS ON OLD LIGHT FIXTURE CONNECTION
Electrical
Issued 11 March 1999
Resolved
BRIDGE: INSTALL A COVER OVER THE LIGHT ABOVE THE HELM CHAIR
Lifesaving
Issued 23 July 1998
Resolved
Properly attach waterlights to lifefloats.
Accommodation/Occupational Safety
Issued 23 July 1998
Resolved
ReFasten loose deck stanchions on pilothouse deck.
Electrical
Issued 23 July 1998
Resolved
Replace missing globe for light fixtue on pilothouse deck.
Accommodation/Occupational Safety
Issued 23 July 1998
Resolved
Properly repair broken stanchion for lifeline/railing at bow portside.
Lifesaving
Issued 6 April 1998
Resolved
REPAIR/REPLACE BROKEN/SPLIT LIFE FLOAT PADDLES (3)_x001C_
Engineering
Issued 6 April 1998
Resolved
PROVE PROPER OPERATION OF EMERGENCY SHUTDOWN FOR MDE (PULL CABLE FROM P/H)_x001C_
Documentation
Issued 6 April 1998
Resolved
POST DRUG ASSISTANCE PHONE NUMBERS FOR EMPLOYEES
Documentation
Issued 6 April 1998
Resolved
PROVIDE A COMPLETE WASTE MANAGEMENT PLAN FOR DISPOSAL OF TRASH.
Lifesaving
Issued 6 April 1998
Resolved
PROVIDE A COMPLETE AND APPROVED FIRST AID KIT.
Lifesaving
Issued 6 April 1998
Resolved
SHOW PROOF OF EPIRB REGISTRATION WITH NOAA
Construction/Loadline
Issued 6 April 1998
Resolved
REPAIR/REPLACE GASKET ON FWD COMPARTMENT HATCH
Engineering
Issued 6 April 1998
Resolved
PROPERLY LABEL ALL FUEL SHUT-OFF VALVES. DUE TO NUMBER OF SHUT-OFFS (7) EACH ONE SHALL BE LABELED FOR PROPER IDENTIFICATION.
Construction/Loadline
Issued 14 January 1998
Resolved
OWNER/OPERATOR TO SECURE AFT HINGE ON STBD SIDE RECOVERY DOOR ON MAIN DECK.
Fire Fighting
Issued 14 January 1998
Resolved
OWNER OPERATOR TO SHOW PROOF THAT ALL FIRE EXTINGUISHERS ONBOARD HAVE BEEN TESTED. ALL FIRE EXTINGUISHERS LAST TESTED JAN 97.
Accommodation/Occupational Safety
Issued 14 January 1998
Resolved
OWNER/OPERATOR TO TIGHTEN ALL HANDRAILS ON UPPER AND LOWER DECKS.
Lifesaving
Issued 18 March 1996
Resolved
RENEW RETROREFLECTIVE TAPE ON ALL LIFE FLOATS
Fire Fighting
Issued 18 March 1996
Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP DRIVEN OFF #1 MDE AT 60 PSI ON DISCHARGE SIDE OF PUMP PRIOR TO OPERATION OF VESSEL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Lifesaving
Issued 18 March 1996
Resolved
RENEW 3 ADULT TYPE I LIFEJACKETS TO REPLACE 3 ADULT TYPE I LIFEJACKETS WHICH WERE REJECTED. PASSENGER ALLOWANCE IS REDUCED BY 3 UNTIL LIFEJACKETSARE PROVIDED.
Navigation
Issued 18 March 1996
Resolved
PROVE PROPER OPERATION OF NAVIGATION LIGHTS IN ACCORDANCE WITH UL STANDARD 1104 AS PER 46 CFR 183.420.
Lifesaving
Issued 17 January 1996
Resolved
REMOVE OIL FROM ENGINE ROOM BILGES
Lifesaving
Issued 17 January 1996
Resolved
INSTALL BELT GUARD ON STBD MDE.
Electrical
Issued 17 January 1996
Resolved
REMOVE OR REPLACE AND HARD WIRE CORD OVER STBD GEN.
Electrical
Issued 17 January 1996
Resolved
PROPERLY HANG WIRES TO PORT TRIM TABS IN LAZARETTE
Engineering
Issued 17 January 1996
Resolved
REPAIR #2 & #3 PORT EXHAUST PIPESW AT COUPLING IN LAZARETTE
Unknown
Issued 17 January 1996
Resolved
FILL ALL HOLES IN BOTH ENGINE ROOM BLKHDS.
Electrical
Issued 17 January 1996
Resolved
REPLACE OR INSTALL ALL MISSING LIGHT GLOBES AND GUARDS THROUGHOUT VSL.
Engineering
Issued 17 January 1996
Resolved
REPLACE BOILER EXHAUST ELBOW IN LAZARETTE.
Unknown
Issued 17 January 1996
Resolved
REPAIR LAZARETTE VENT ON DECK.
Unknown
Issued 17 January 1996
Resolved
PROVE PROPER OPERATION OF STBD MDE SEA SUCTION VALVE.
Fire Fighting
Issued 17 January 1996
Resolved
SECURELY MOUNT PORT FIRE PUMP
Lifesaving
Issued 17 January 1996
Resolved
INSTALL BELT GUARD ON PORT GENERATOR
Unknown
Issued 18 March 1994
Resolved
REMOAVE HYDRAULIC FLUID FROM FORE PEAK AND MAKE READY FOR INSPECTION.
Unknown
Issued 18 March 1994
Resolved
REMOVE WATER FROM FORWARD STORAGE COMPARTMENT & MAKE READY FOR INSPECTION.
Lifesaving
Issued 18 March 1994
Resolved
UNTIL REPLACEMENT OF 25 ADULT LIFE PRESERVERS, TOTAL COASTWISE MANNING IS REDUCED TO 100 PERSONS ON BOARD.
Engineering
Issued 21 January 1994
Resolved
TIGHTEN ENG. BREATHER CLAMPS + REPLACE EXHAUST INSULATION JACKETS ON ALL ENG. _x001C_ _x001C_ _x001C_
Navigation
Issued 21 January 1994
Resolved
REPLACE PORT RUDDER SHAFT KEY IN LAZZERETTE.
Navigation
Issued 21 January 1994
Resolved
SECURE PORT HYDRAULIC RAM BAR.
Construction/Loadline
Issued 21 January 1994
Resolved
PROVIDE NYCMI WITH SUBDIVISION CALCULATIONS. UNTIL THIS REQUIREMENT IS COMPLETE, THIS VESSEL IS RESTRICTED TO LESS THAN 50 PERSONS.
Construction/Loadline
Issued 21 January 1994
Resolved
LABEL BILGE MANIFOLD.
Engineering
Issued 21 January 1994
Resolved
SECURE STARBOARD ENGINE MOUNTING BOLTS.
Construction/Loadline
Issued 21 January 1994
Resolved
DOUBLE CLAMP ALL SALT WATER LINES.
Engineering
Issued 21 January 1994
Resolved
DOUBLE CLAMP ALL EXHAUST HOSES.
Navigation
Issued 10 April 1991
Resolved
PROVIDE MAGNETIC COMPASS DEVIATION TABLE.
Unknown
Issued 10 April 1991
Resolved
INSTALL PROPER FUEL VENT FLAME SCREENS FOR ALL FUEL TANK VENTS.
Navigation
Issued 10 April 1991
Resolved
MAKE REPAIRS TO AFT PILOTHOUSE WINDOW TO MAKE WEATHERTIGHT.
Fire Fighting
Issued 10 April 1991
Resolved
INSTALL AND PROVE PROPER OPERATION OF ELECTRIC FIRE PUMP PRESSURE GAUGE.
Engineering
Issued 10 April 1991
Resolved
PROVE PROPER OPERATION OF CENTER MAIN DIESEL ENGINE.
Engineering
Issued 10 April 1990
Resolved
MOUNT FUEL OIL FILTER HOUSING FOR BOILER FUEL SUPPLY ON STANCHION IN LAZARETTE.
Fire Fighting
Issued 10 April 1990
Resolved
RENEW PRESSURE GAGE FOR FIRE PUMP STARBOARD FORWARD BULKHEAD IN ENGINEROOM.
Engineering
Issued 10 April 1990
Resolved
INSTALL METAL INSULATION COVERS ON HEATING BOILER (2).
Electrical
Issued 10 April 1990
Resolved
MOUNT COVER PLATES TO ELECTRICAL JUNCTION AND SWITCH BOXES ABOVE BOILER.
Engineering
Issued 10 April 1990
Resolved
INSTALL GUARDS FOR BELT DRIVEN MACHINERY STARBOARD MAIN ENGINE (2) AND STARBOARD SHIP SERVICE GENERATOR (1).
Construction/Loadline
Issued 10 April 1990
Resolved
INSTALL VALVE HANDLE OR RENEW VALVE FOR SALT WATER TO MSD IN LAZARETTE.
Construction/Loadline
Issued 10 April 1990
Resolved
CAULK (2) HOLES IN BULKHEAD OF ENGINE ROOM LAZARETTE STARBOARD OUTBOARD ANDONE MIDSHIPS AT OVERHEAD FOR WIRE WAY AND FUEL LINE.
Engineering
Issued 10 April 1990
Resolved
REMOVE CARPET FROM ENGINE ROOM DECK PLATES.
Construction/Loadline
Issued 3 January 1990
Resolved
INSTALL BILGE SUCTION STRAINERS WHERE MISSING.
Engineering
Issued 3 January 1990
Resolved
INSTALL FLAME SCREENS TO FUEL TANK VENTS WHERE MISSING.
Electrical
Issued 3 January 1990
Resolved
REPLACE NON-USCG APPROVED FLEXIBLE FUEL LINES ON BOTH SERVICE GENERATORS WITH USCG APPROVED TYPE.
Documentation
Issued 3 January 1990
Resolved
PROVIDE EITHER EVIDENCE OF INCLINING TEST OR STABILITY CALCULATIONS BY A NAVAL ARCHITECT TO SHOW ACCEPTABLE STABILITY PARAMETERS FOLLOWING REMOVAL OF CENTER MAIN DIESEL ENGINE.
Engineering
Issued 19 April 1989
Resolved
INSTALL BILGE SUCTION STRAINER WHERE MISSING.
Engineering
Issued 19 April 1989
Resolved
INSTALL FLAME SCREENS FUEL TANK VENTS WHERE MISSING.
Electrical
Issued 19 April 1989
Resolved
INSTALL BULB IN 32 VOC LIGHT FORWARD.
Engineering
Issued 19 April 1989
Resolved
CAP OR PLUG ENGINE EXHAUSTS FROM REMOVED CENTERLINE ENGINE WHERE THEY PASS TO STEERING COMPARTMENT.
Lifesaving
Issued 19 April 1989
Resolved
LABLE FIRE AXE AND LIFE FLOAT PADDLES WITH VESSELS NAME WHERE MISSING.
Fire Fighting
Issued 19 April 1989
Resolved
PROVIDE DISCHARGE HOSE FOR FIREFIGHTING FOR HAND FIRE AND BILGE PUMP.
Navigation
Issued 19 April 1989
Resolved
PROVIDE CURRENT TIDE TABLE AND COAST PILOT.
Documentation
Issued 19 April 1989
Resolved
POST EMERGENCY CHECKLIST.
Lifesaving
Issued 19 April 1989
Resolved
REPAIR SNAPS ON SIX ADULT AND ONE CHILD PFD REPLACE MISSING CHILD PFD.
Lifesaving
Issued 19 April 1988
Resolved
SECURE (2) TWO PADDLES PER LIFE FLOAT TO THE INTERIOR OF LIFE FLOAT, ON ALL(3) THREE LIFE FLOATS.
Navigation
Issued 19 April 1988
Resolved
REPLACE ALL NAVIGATIONAL RUNNING LIGHTS, WITH UL MARINE APPROVED TYPE.
Electrical
Issued 19 April 1988
Resolved
PROVIDE AN OPERATIONAL UNDER LOAD TEST OF THE PORT SERVICE GENERATOR, PRESENTLY INOPERABLE.
Engineering
Issued 19 April 1988
Resolved
PROVIDE AN OPERATIONAL TEST OF THE CENTER MAIN DIESEL ENGINE, PRESENTLY INOPERABLE.
Engineering
Issued 19 April 1988
Resolved
REPLACE (1) ONE NON-CG APPROVED FLEXIBLE FUEL LINE ON SERVICE GENERATOR, WITH CG APPROVED TYPE.
Lifesaving
Issued 19 April 1988
Resolved
REPLACE ALL NETTING IN THE FLOOR OF (3) THREE LIFE FLOATS, WHERE DETERIORATED. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS FOR HIRE, UNTILTHIS ITEM IS CORRECTED.
Fire Fighting
Issued 19 April 1988
Resolved
PROVIDE AN OPERATIONAL TEST OF THE STARBOARD MAIN DIESEL ENGINE'S BELT DRIVEN FUEL PUMP, WHICH IS PRESENTLY INOPERABLE. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS FOR HIRE, UNTIL THIS ITEM IS CORRECTED.
Fire Fighting
Issued 19 April 1988
Resolved
PROVIDE (1) ONE B-II PORTABLE FIRE EXTINGUISHER WHICH WEIGHED IS (2) TWO POUNDS LIGHT. VESSEL RESTRICTED FROM CARRYING PASSENGERS FOR HIRE UNTIL ITEM IS CORRECTED.
Documentation
Issued 6 April 1987
Resolved
PROVIDE VALID STICKER FOR VESSEL'S DOCUMENT, PRESENT STICKER EXPIRED 3/86.
Engineering
Issued 6 April 1987
Resolved
REPLACE OR CONVERT PRESENT RACOR FUEL FILTERS 3 EACH, WITH COAST GUARD APPROVED FUEL FILTERS.
Engineering
Issued 6 April 1987
Resolved
REPLACE 3 NON-COAST GUARD APPROVED FLEX FUEL LINES WITH COAST GUARD APPROVED ON AUXILIARY GENERATOR.
Electrical
Issued 21 March 1986
Resolved
PROVIDE BATTERY BOX COVERS ON 3 - BATTERY BOXES IN ENGINE SPACE, WHERE MISSING.
Lifesaving
Issued 21 March 1986
Resolved
REPLACE LINES ON INSIDE PLATFORMS OF 3 - BA'S, WHERE DETERIORATED.
Lifesaving
Issued 21 March 1986
Resolved
REPLACE OR REPAIR GRAB LINES ON 3 - RING BUOY'S, WHERE DETERIORATED.
Lifesaving
Issued 21 March 1986
Resolved
PROVIDE OPERATIONAL TEST OF 1 WATERLIGHT, PRESENTLY OOC.
Engineering
Issued 19 March 1985
Resolved
PROVIDE FOR FIRESIDE EXAMINATION UNDER WORKING PRESSURE HYDROSTATIC TEST OFCARLIN OIL FIRED HEATING BOILER.
Navigation
Issued 19 March 1985
Resolved
PROVE THAT VESSEL'S WHISTLE AIR TANK MANUFACTURED BY SEARS, IS BUILT TO THEREQUIREMENTS IN SECTION VIII DIVISION 1 OF THE ASME CODE.
Fire Fighting
Issued 19 March 1985
Resolved
PROVIDE FOR PROPER SERVICING OF BII DRY CHEMICAL EXTINGUISHER LOCATED STARBOARD SIDE OF ENGINE ROOM.
Fire Fighting
Issued 19 March 1985
Resolved
PROVIDE ONE FIRE AXE.
Casualty record · 2
19 April 2011Routine · role: Involved in a Marine Casualty · activity 4137656
23 May 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 4071413
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
CAPTREE STAR III (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.