Records from 1981 to 2008. Most recent: inspection, 2 December 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 57
2 December 2008
Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3372938
28 October 2008
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3463843
11 October 2007
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3082287
12 April 2007
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2930871
26 March 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2893539
21 March 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2886428
23 May 2005
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2365654
17 March 2005
Internal Structural Exam · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2297179
31 January 2005
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2283564
18 March 2004
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2033537
25 November 2003
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1958280
4 February 2003
Internal Structural Exam · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1739254
27 August 2002
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1667532
6 August 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437960
2 July 2001
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1068495
11 June 2001
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1065292
20 February 2001
Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1379309
30 August 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821925
12 July 1999
Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 731702
10 June 1999
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445514
12 May 1999
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1497067
16 July 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1454573
15 April 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1124779
12 June 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1407996
29 May 1997
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1407995
9 July 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1089555
11 June 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402260
8 November 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 884162
8 August 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 881045
6 July 1995
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1353765
21 June 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1175513
9 August 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1157584
21 July 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 842813
16 June 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 845566
8 June 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142021
7 April 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1138147
22 April 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1260924
2 October 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 948065
24 September 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 942223
24 September 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1258192
1 May 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1212394
17 April 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1221958
25 April 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 909263
28 February 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 920808
26 April 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1348557
12 April 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895175
7 September 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1351928
6 April 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 889063
24 June 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1314458
28 April 1987
COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1316741
29 April 1986
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 986835
28 August 1985
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 988508
29 August 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280579
28 August 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280578
10 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 964067
1 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969848
1 September 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967828
Construction/Loadline › Hull › Side Shell
Issued 2 December 2008
Resolved
Repair rotted wood on starboard bow near chine 7.5 feet from stem.
Action required: 705 - Other - as specified
Due 2 January 2009
Resolved 23 December 2008
Resolution: Planking replaced
Construction/Loadline › Hull › Transverse Frame
Issued 2 December 2008
Resolved
Repair or renew rotted floor in lazarette approximately 3 feet from transom.
Action required: 705 - Other - as specified
Due 2 January 2009
Resolved 23 December 2008
Resolution: Floor frame replaced
Construction/Loadline › Hull › Side Shell
Issued 2 December 2008
Resolved
Repair or replace wasted planking directly outboard of both port and starboard engines approximately 8 planks up from chine.
Action required: 705 - Other - as specified
Due 2 January 2009
Resolved 23 December 2008
Resolution: Wasted planking replaced.
Construction/Loadline › Hull › Longitudinal Frame
Issued 2 December 2008
Resolved
Replace longitudinal deck beam located outboard of aft of starboard engine.
Action required: 705 - Other - as specified
Due 2 January 2009
Resolved 23 December 2008
Resolution: Replaced beam
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 2 December 2008
Resolved
Replace starboard cutlass bearing.
Action required: 705 - Other - as specified
Due 2 January 2009
Resolved 23 December 2008
Resolution: Bearing replaced.
Construction/Loadline › Hull › Side Shell
Issued 2 December 2008
Resolved
Re-plug all exposed fasteners.
Action required: 705 - Other - as specified
Due 2 January 2009
Resolved 23 December 2008
Resolution: Fasteners covered
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 2 December 2008
Resolved
Remove all fluids form bilge in engine room and vee berth.
Action required: 705 - Other - as specified
Due 2 January 2009
Resolved 23 December 2008
Resolution: Fluids have been removed
Construction/Loadline › Hull › Keel
Issued 2 December 2008
Resolved
Replace aft section of worm shoe.
Action required: 705 - Other - as specified
Due 2 January 2009
Resolved 23 December 2008
Resolution: Worm shoe replaced
Construction/Loadline › Hull › Side Shell
Issued 2 December 2008
Resolved
Repair all marked section of hull.
Action required: 705 - Other - as specified
Due 2 January 2009
Resolved 23 December 2008
Resolution: All areas discussed with operator have been repaired or replaced.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 October 2007
Resolved
Repair bilge high level alarms, noted lights to be non-operational. 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2007
Documentation › Certificates/Documents › FCC SSL
Issued 12 April 2007
Resolved
Renew expired FCC Station License and Safety Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2007
Communications › Radio Communications › EPIRB
Issued 12 April 2007
Resolved
Renew expired EPIRB registration. 46CFR180
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 April 2007
Resolved
Service portable and fixed fire fighting systems. 46CFR181
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 12 April 2007
Resolved
Repair main engine clutch assembly. 46CFR176
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2007
Engineering › Thrusters › Bearing
Issued 21 March 2007
Resolved
Replace starboard cutlass bearing in accordance with 46 CFR 176.630.
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 26 March 2007
Resolution: Cutlass bearing replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 21 March 2007
Resolved
Make proper repairs to worm shoe in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 26 March 2007
Resolution: Worm shoe replaced
Construction/Loadline › Penetrations › Gasket
Issued 21 March 2007
Resolved
Make lazarette hatch watertight in accordance with 46 CFR 176.16.
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 26 March 2007
Resolution: Lazarette hatch gasket replaced
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 May 2005
Resolved
Make proper repairs to forward deck rail fasteners. Make permanent repairs to forward deck rail anchor points to as built specifications not later than 30 OCT 2005 (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 30 October 2005
Resolution: Rail fastners repaired.
Construction/Loadline › Structures › Deck Plating
Issued 23 May 2005
Resolved
Make proper repairs to fore deck where rotted and weakened as noted by the inspector. Make permanent repairs prior to 30 OCT 2005.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 30 October 2005
Resolution: Deck repaired.
Construction/Loadline › Hull › Hull Plating
Issued 4 April 2005
Resolved
Renew or replace rotted plank near bow just below waterline on starboard bow as per NVIC 7-95.
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 5 May 2005
Resolution: Rotted plank was replaced IAW NVIC 7-95.
Construction/Loadline › Hull › Bottom Plating
Issued 17 March 2005
Resolved
Countersink and bung 4 fastener heads on port side aft planking near chine as per NVIC 7-95.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Fasteners were pulled, counter sunk and bunged as per NVIC 7-95.
Construction/Loadline › Hull › Bottom Plating
Issued 17 March 2005
Resolved
Renew plank on port side aft, 1 strake inboard from chine using NVIC 7-95 as a guide
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Plank was replaced IAW NVIC 7-95.
Construction/Loadline › Hull › Bottom Plating
Issued 17 March 2005
Resolved
Renew or replace 2 wet rotted planks on starboard side near bow as per NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Replaced both planks in kind IAW NVIC 7-95.
Construction/Loadline › Hull › Bottom Plating
Issued 17 March 2005
Resolved
Countersink and bung exposed nail on bow planking as per NVIC 7-95
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Fastener was removed, countersunk and bunged IAW NVIC 7-95.
Construction/Loadline › Hull › Bottom Plating
Issued 17 March 2005
Resolved
Renew or replace holed plank forward near keel on starboard side as per NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Plank was replaced IAW NVIC 7-95.
Construction/Loadline › Hull › Side Shell
Issued 17 March 2005
Resolved
Renew or replace starboard plank with a dutchman located forward adjacent to chine as per NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Plank was replaced IAW NVIC 7-95.
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2005
Resolved
Repair or replace two rotted planks located amidships on starboard side as per NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Rotted planks were replaced IAW NVIC 7-95.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 17 March 2005
Resolved
Remove oil from engine room bilges in order to view bottom planking as per 46 CFR 176-830.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Oil was removed from bilges.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 31 January 2005
Resolved
Replace or retest/re-condition forward B-II. Certify annual test on pilothouse B-I 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2005
Resolved 23 May 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 31 January 2005
Resolved
Provide tide and current table for 2005 for areas transited 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2005
Resolved 23 May 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 January 2005
Resolved
Refasten bow deck rail 46 CFR 177.900.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 23 May 2005
Resolution: Rails refastened as a temporary repair. Rail anchor points will require permanent repair not later than 30 OCT 2005.
Documentation › Markings/Placards › Capacity Marking
Issued 31 January 2005
Resolved
Mark upper deck "Crew Only" 46 CFR 185.602(g)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2005
Resolved 23 May 2005
Lifesaving › Lifefloat › Painter
Issued 31 January 2005
Resolved
Replace life float painter 46 CFR 180.137.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 23 May 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 31 January 2005
Resolved
Post legible life jacket donning placard in main passenger space 46 CFR 185.516.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 23 May 2005
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 31 January 2005
Resolved
Remove oil from bilges 33 CFR 155.770.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 23 May 2005
Engineering › Bilge Water Management System › Pump
Issued 31 January 2005
Resolved
Repair bilge pump and bilge alarm system 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2005
Resolved 23 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 January 2005
Resolved
Provide proper first aid kit 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2005
Resolved 23 May 2005
Communications › Audible Communications
Issued 25 November 2003
Resolved
Provide properly working horn/sound device IAW 33 CFR 86. LEGACY COMPONENT DESC: Horn/Whistle
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 18 March 2004
Resolution: Owner provided proper horn.
Personnel › Training
Issued 25 November 2003
Resolved
Provide proof of 50% of crew current first aid/CPR training IAW NVIC 1-91. LEGACY COMPONENT DESC: First Aid/CPR
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 18 March 2004
Resolution: Owner provided proof of first aid training.
Communications › Radio Communications
Issued 25 November 2003
Resolved
Vessel not to carry passengers until EPIRB battery has been serviced/in date IAW 46 CFR 185.728. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 18 March 2004
Resolution: Owner provided new battery for EPIRB.
Communications › Internal Communications System
Issued 25 November 2003
Resolved
Provide public address system IAW 46 CFR 184.610. LEGACY COMPONENT DESC: Public Address System
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 18 March 2004
Resolution: Owner provided public address system.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 25 November 2003
Resolved
Make proper repairs to both main engine exhaust cooling system @ water injection fitting. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 18 March 2004
Resolution: Owner repaired cooling system for exhaust.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2003
Resolved
Install machinery guard on port main engine alternator IAW 46 CFR 177.960. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 18 March 2004
Resolution: Owner installed machinery guard.
Communications › Alarms/Indicators
Issued 25 November 2003
Resolved
Provide visual alarms for bilge pumps IAW 46 CFR 182.530. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 18 March 2004
Resolution: Owner provided visual alarms for bilge pumps.
Electrical › Lighting (service)
Issued 25 November 2003
Resolved
Provide proper engine room light fixtures IAW 46 CFR 183.410. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 18 March 2004
Resolution: Owner provided proper light fixtures.
Documentation › Certificates/Documents
Issued 25 November 2003
Resolved
Provide proper FCC documentation as required by 47 CFR 80. LEGACY COMPONENT DESC: FCC Certificates
Action required: 705 - Other - as specified
Due 25 December 2003
Resolved 18 March 2004
Resolution: Owner provided proper FCC documentation.
Construction/Loadline › Hull
Issued 4 February 2003
Resolved
Remove and treat excessive angel hair (decay) in engine room. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 4 March 2003
Resolved 11 March 2003
Resolution: Examined, found satisfactory
Pollution Prevention/Response
Issued 4 February 2003
Resolved
Remove oil from bilges LEGACY COMPONENT DESC: Bilges
Action required: 705 - Other - as specified
Due 4 March 2003
Resolved 11 March 2003
Resolution: Examined, found satisfactory
Fire Fighting › Ventilation Systems
Issued 4 February 2003
Resolved
Provide coaming on vent openings both port and starboard side. LEGACY COMPONENT DESC: Natural ventilation
Condition: Improper Installation
Due 4 March 2003
Resolved 11 March 2003
Resolution: Examined, found satisfactory
Stability › Watertight Integrity
Issued 4 February 2003
Resolved
Replace forward hatch cover and make watertight. LEGACY COMPONENT DESC: Hatch cover
Condition: Unknown
Due 4 March 2003
Resolved 11 March 2003
Resolution: Examined, found satisfactory
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 February 2003
Resolved
Replace port engine exhaust hose and connections. LEGACY COMPONENT DESC: Piping (exhaust)
Due 4 March 2003
Resolved 11 March 2003
Resolution: Examined, found satisfactory
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 February 2003
Resolved
Replace stern tube clamps on both main engine shafts. LEGACY COMPONENT DESC: Stern tube clamps
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 11 March 2003
Resolution: Examined, found satisfactory
Engineering › Fuel Oil Service System
Issued 4 February 2003
Resolved
Provide vent for both main fuel oil tanks currently venting through return connections. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper Installation
Due 4 March 2003
Resolved 11 March 2003
Resolution: Examined, found satisfactory
Electrical
Issued 30 August 2000
Resolved
PROVIDE PROPER LIGHT COVERS AS REQUIRED BY 46 CFR 183.410
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Engineering
Issued 30 August 2000
Resolved
PROVIDE MACHINERY GUARDS ON ALL ENGINES AS REQUIRED BY 46 CFR 177.960
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Navigation
Issued 30 August 2000
Resolved
PROVIDE CURRENT CHARTS AND PUBS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Navigation
Issued 30 August 2000
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD AS REQUIRED BY 46 CFR 185.410
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Lifesaving
Issued 12 June 1997
Resolved
CONDUCT UNDERWAY CREW TRAINING DRILLS AND DEMONSTRATE PROFICIENCY FOR ALL CREW MEMBERS.
Condition: Unknown
Due 12 July 1997
Resolved 10 November 1997
Electrical
Issued 12 June 1997
Resolved
PROVIDE 110 VAC BREAKER PANEL WITH APPROPRIATE COVER.
Condition: Unknown
Due 12 July 1997
Resolved 10 November 1997
Lifesaving
Issued 12 June 1997
Resolved
REGISTER NEW 406MHZ EMERGENCY POSITION INDICATING RADIO BEACON WITH NOAA, ONCE DECAL IS RECEIVED PLACE DECAL ON EPRIB.
Condition: Unknown
Due 12 July 1997
Resolved 10 November 1997
Engineering
Issued 11 June 1996
Resolved
REPAIR WATER LEAK ON PORT EXHAUST PIPE IN ENGINE ROOM.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Navigation
Issued 11 June 1996
Resolved
REPACK/REPAIR BOTH THE PORT AND STBD RUDDER SHAFT STUFFING BOXES DUE TO EXCESSIVE LEAKAGE.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Documentation
Issued 11 June 1996
Resolved
PROVIDE PROOF OF A VALID FCC RADIO STATION LICENSE FOR VESSEL.
Condition: Unknown
Due 11 July 1996
Resolved 18 June 1996
Construction/Loadline
Issued 11 June 1996
Resolved
REPAIR HULL WATER LEAK ON BOTH THE PORT AND STBD BOW STEM IN THE FOREPEAK.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Accommodation/Occupational Safety
Issued 8 August 1995
Resolved
RENEW BROKEN WINDHIELD ON PORT SIDE OF PILOTHOUSE.
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Engineering
Issued 6 July 1995
Resolved
REPAIR FRACTURED EXHAUST PIPE ON STBD ENGINE.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Construction/Loadline
Issued 6 July 1995
Resolved
FOR COMPLETE DETAILS OF HULL REPAIRS COMLETED DURING THIS DRYDOCK EXAM, SEEMINS FOR CASE# MI95024366
Condition: Unknown
Due 6 July 1995
Resolved 12 July 1995
Accommodation/Occupational Safety
Issued 6 July 1995
Resolved
PROPERLY RE-LABLE EXTERIOR OF EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Navigation
Issued 6 July 1995
Resolved
PROVIDE PROPER SIZE BELL IAW 72 COLREGS ANNEX III (7.9IN/200MM).
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Documentation
Issued 6 July 1995
Resolved
PROVIDE VALID FCC RADIO STATION LICENSE AND RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Construction/Loadline
Issued 6 July 1995
Resolved
MAKE AFT DECK HATCH WEATHERTIGHT AND PROVIDE MEANS FOR OPENING ACCESS.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Navigation
Issued 6 July 1995
Resolved
RAISE ANCHOR LIGHT SO THAT ARC OF VISIBILITY MEETS 360 DEGREE REQUIREMENT IAW 72 COLREGS RULE 23.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Navigation
Issued 6 July 1995
Resolved
PROVE PROPER OPERATION OF VESSELS SOUND PRODUCING DEVICE.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Electrical
Issued 21 June 1994
Resolved
PROPERLY CONNECT ELECTRICAL WIRING ON MSD PUMP (REMOVE WIRE NUTS).
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Electrical
Issued 21 June 1994
Resolved
PROPERLY MOUNT HEAD LIGHT SWITCH.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Accommodation/Occupational Safety
Issued 21 June 1994
Resolved
REFASTEN PORT AND STARBOARD BOW/AFT HANDRAIL STANTIONS.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Engineering
Issued 21 June 1994
Resolved
REPAIR PORT FUEL TANK EMERGENCY FUEL SHUT OFF VALVE
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Navigation
Issued 21 June 1994
Resolved
DOUBLE NUT ALL STEERING BOLTS.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Engineering
Issued 21 June 1994
Resolved
TIGHTEN STARBOARD SHAFT PACKING.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Engineering
Issued 21 June 1994
Resolved
REPAIR LUBE OIL LEAK ON PILOT HOUSE OIL GAUGE LINBES.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Electrical
Issued 21 June 1994
Resolved
PROPERLY INSTALL 110 VOLT SHORETIE USING MARINE TYPE BOX AND CONNECTIONS.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Construction/Loadline
Issued 21 June 1994
Resolved
REPAIR EMERGENCY ESCAPE HATCH HINGES.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Electrical
Issued 21 June 1994
Resolved
INSTALL MACHINERY GUARDS ON PORT ENGINE ALTINATOR AND WASH DOWN PUMP.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Engineering
Issued 21 June 1994
Resolved
PROPERLY MOUNT LUBE OIL FILTERS FOR BOTH MAIN ENGINES.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Electrical
Issued 21 June 1994
Resolved
PROVE PROPER OPERATION OF GENERATOR.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Electrical
Issued 21 June 1994
Resolved
INSTALL COVER ON LAMP FIXTURE LOCATED IN HEAD.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Electrical
Issued 16 June 1993
Resolved
PROVE OPERATION OF GENERATOR VOLT METER AND AMMMETER.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Fire Fighting
Issued 16 June 1993
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Documentation
Issued 16 June 1993
Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Electrical
Issued 16 June 1993
Resolved
PROPERLY SECURE BATTERY BOXES TO PREVENT SHIFTING.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Electrical
Issued 16 June 1993
Resolved
INSTALL COVERS OVER BATTERY TERMINALS TO PREVENT ACCIDENTAL SHORTING OF BATTERIES.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Lifesaving
Issued 16 June 1993
Resolved
INSTALL ADDITIONAL RETRO REFLECTIVE MATERIAL TO ALL LIFE PRESERVERS.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Engineering
Issued 16 June 1993
Resolved
PROVE OPERATION OF GENERATOR DIESEL ENGINE TEMPERATURE GAGE.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Documentation
Issued 16 June 1993
Resolved
PROVIDE AND POST LEGIBLE OIL POLLUTION PLACARD.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Documentation
Issued 16 June 1993
Resolved
PROVIDE EVIDENCE OF CHEMICAL TESTING OF ALL MARINE EMPLOYEES IN ACCORDANCE WITH 46 CFR 16.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Engineering
Issued 24 September 1991
Resolved
RENEW FLAME SCREENS ON FUEL TANK VENTS.
Condition: Unknown
Due 2 October 1991
Resolved 12 March 1992
Construction/Loadline
Issued 24 September 1991
Resolved
RENEW NUTS AND BOLTS FOR TRANSOM BLOCK.
Condition: Unknown
Due 2 October 1991
Resolved 12 March 1992
Engineering
Issued 24 September 1991
Resolved
DOUBLE HOSE CLAMP HOSE, EXHAUST FLEX COUPLING STARBOARD SIDE.
Condition: Unknown
Due 2 October 1991
Resolved 12 March 1992
Construction/Loadline
Issued 24 September 1991
Resolved
RENEW KEEL BOLTS AND NUTS IN FORWARD BILGE AREA.
Condition: Unknown
Due 2 October 1991
Resolved 12 March 1992
Engineering
Issued 24 September 1991
Resolved
REMOVE PVC PIPE FROM EXHAUST SYSTEM.
Condition: Unknown
Due 2 October 1991
Resolved 12 March 1992
Construction/Loadline
Issued 24 September 1991
Resolved
RENEW BUTT BLOCK STARBOARD SIDE ENGINE COMPARTMENT.
Condition: Unknown
Due 2 October 1991
Resolved 12 March 1992
Engineering
Issued 17 April 1991
Resolved
PROVIDE A SUITABLE WARNING DEVICE TO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM OF BOTH MDE'S AND GENERATOR, SUCH WARNING SHALL BE VISIBLE OR AUDIBLE AT THE ENGINE OPERATION STATION.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Fire Fighting
Issued 17 April 1991
Resolved
INSTALL APPROVED FIRE EXTINGUISHERS BRACKETS FOR MARINE USE FOR ALL FIRE EXTINGUISHER
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Engineering
Issued 17 April 1991
Resolved
RENEW FUEL LINES FROM FUEL FILTERS AND FUEL TANKS WITH FUEL LINE WITH FACTORY FITTINGS
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Lifesaving
Issued 17 April 1991
Resolved
RENEW WATER LIGHT LINE ON BOUYANT APPARATUS WITH AT LEAST 18 FEET OF LINE
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Engineering
Issued 17 April 1991
Resolved
RENEW FLAME SCREENS TO FUEL TANK VENTS OF AT LEAST 20X20 MESH
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Navigation
Issued 17 April 1991
Resolved
TIGHTEN STBD SIDE RUDDER BARREL NUT_x001C_
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Construction/Loadline
Issued 17 April 1991
Resolved
STENCIL EMERGENCY EXITS WITH "EMERGENCY EXIT, KEEP CLEAR" IN AT LEAST 1" LETTERS.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Electrical
Issued 17 April 1991
Resolved
PROVE OPERATION OF GENERATOR
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Electrical
Issued 17 April 1991
Resolved
INSTALL BATTERY BOX FOR GENERATOR STARTING BATTERY
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Electrical
Issued 17 April 1991
Resolved
INSTALL TERMINAL BLOCK FOR ELECTRICAL BILGE PUMP CONNECTION FWD.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Navigation
Issued 17 April 1991
Resolved
RENEW HYDRAULIC LINES TO STEERING HYDRAULIC RAM AND SUPPORT LINES WITH PROPER TYPE HANGERS
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Navigation
Issued 17 April 1991
Resolved
RENEW NAVIGATION LIGHTS WITH PROPER SIZE FIXTURES
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Lifesaving
Issued 17 April 1991
Resolved
RENEW PENDANTS ON BOUYANT APPARATUS WITH AT LEAST 12 FT OF LINE
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Construction/Loadline
Issued 12 April 1989
Resolved
MAKE PERMANANT REPAIRS TO RAILING IN-WAY-OF BOW. 46CFR 72.40-5
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Construction/Loadline
Issued 12 April 1989
Resolved
MAKE PERMANANT REPAIRS TO #1,2,3 PORT LOADING RAMPS AND PROVE PROPER OPERATION OF SAME. 46CFR 72.40-15
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Construction/Loadline
Issued 28 August 1984
Resolved
PROVIDE A 36" HAND RAIL WITH COURSES NOT GREATER THAN 12" APART ON THE PERIPHERY OF THE PILOT HOUSE AND BOW.
Condition: Unknown
Due 28 August 1984
Resolved 28 August 1984