← All vessels
ISLAND GIRL
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named ISLAND GIRL
ISLAND GIRL is a 1978 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1985, most recently in April 2026, along with 86 deficiencies and 1 operational control.
Records from 1985 to 2026. Most recent: inspection, 28 April 2026.
- Built
- 1978
- Last inspected
- 28 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 86 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
593584
WDG8832
49700
Flag
UNITED STATES
367581510
Maury page id
psix-49700
Inspections, by type
…with no type recorded8
Years with a record
38 calendar years (1985–2026)
The 66 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)53.2 ft × 16.8 ft × 6.4 ft
Registered tonnagegross 41 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSIBLEY'S BOAT SHOP · DELTAVILLE, VA, UNITED STATES · built 1978
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 4 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDR3084MMSI 367581510 · active · compulsorily equipped · granted 13 July 2026, expires 13 July 2036
WDG8832MMSI 367581510 · cancelled · compulsorily equipped · granted 2 June 2023, cancelled 12 February 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDC4948MMSI 367033280 · expired · compulsorily equipped · granted 13 April 2005, cancelled 13 June 2015 · licensed under a name not among this hull’s recorded names (not shown)
WAD9416MMSI not assigned · expired · compulsorily equipped · granted 10 August 1994, cancelled 9 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 66
28 April 2026
Vessel Attendance · In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8357350
22 April 2025
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8097604
23 July 2024
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7946339
12 October 2023
Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7798835
30 May 2023
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7697036
20 March 2023
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7653397
1 August 2022
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7521887
12 April 2021
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7175264
15 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7006928
22 May 2019
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6692305
16 May 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6686187
12 June 2018
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6441417
10 May 2017
Annual Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6156176
14 February 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6089432
16 January 2016
Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5829021
15 October 2015
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5743074
22 July 2015
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5192315
10 June 2014
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4884361
31 August 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4131857
22 February 2010
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3686084
27 May 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3219063
29 April 2008
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3194797
15 May 2007
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2930778
20 April 2006
Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2628913
26 April 2004
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2052834
13 June 2003
Type not recorded
No type recorded · Station Philadelphia · USCG East District (CGD-E) · Activity 1817114
21 May 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1797275
21 April 2003
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1773587
14 May 2002
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1616270
10 August 2001
Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1070801
22 May 2001
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1063454
16 April 2001
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1062312
25 May 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1049834
14 July 1999
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1096783
27 May 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 803519
30 April 1999
Plan Review "T" Boat · COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1360838
14 August 1998
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1437439
28 May 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1107876
30 August 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 938810
21 May 1996
Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1082637
30 April 1996
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1085913
26 May 1995
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 924960
13 June 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324758
12 May 1994
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1161424
12 May 1994
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1382781
1 June 1993
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1458102
2 June 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1255603
5 May 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1256930
28 May 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1319805
7 May 1991
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1215130
20 April 1990
Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1227549
18 August 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1339952
18 August 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1347819
16 May 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888363
10 April 1989
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888635
17 May 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888969
28 March 1988
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036018
21 May 1987
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1001685
21 April 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1018745
11 July 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 998895
14 May 1986
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1294014
1 April 1986
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306547
9 September 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 991451
28 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983730
17 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1291521
15 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1290578
Deficiency record · 86
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2026
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for the annual inspection. Conduct annual inspection prior to carriage of passengers.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 31 May 2024
Resolved
Each vessel in each condition of loading and operation shall comply with intact stability requirements. Due to historical cummulative weight changes, the vessel is required to complete a new simplified stability test. Temp ops authorized w/reduced passengers (29) and reduced route (protected).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2023
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. During sea trial, noted excessive vibration of both propeller shafts as well as apparent chaffing of the shafts due to alignment. Make shafts available for inspection.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 October 2023
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. During sea trials, observed fuel leak from STBD Main Engine fuel connection point.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2023
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. During sea trials, discovered hole in port MDE exhaust hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2023
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Port red gear missing vent cap. Replace cap.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 October 2023
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. Fixed CO2 operating instructions are incorrect. Update to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2023
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Cuddy Cabin portable fire extinguisher found without stock hanger. Provide proper hanger for extinguisher.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 October 2023
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. The use of plastic tie wraps must be limited to bundling. Secure wiring runs below deck with metal supports in lieu of plastic.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 October 2023
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice or extending the length of a circuit. Wire nuts found connecting a light in the cuddy cabin. Remove and remake splice to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 October 2023
Resolved
Fuel supply piping shall be of copper, nickel copper or copper nickel having a minimum wall thickness of 0.035 inch. Generator copper fuel return line is kinked. Replace to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 October 2023
Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings. Generator fuel supply hose connection found with a single hose clamp. Provide two hose clamps to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 October 2023
Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings. Generator fuel return hose connection found with single hose clamps. Renew return hose and provide two hose clamps per end to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2023
Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings. STBD Main Engine fuel supply hose connections found without hose clamps. Provide two hose clamps to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Vessel’s shaft log / packing box hoses are heavily deteriorated. Port hose is bulging with an apparent rip in the outer banding. Stbd hose rubber is failing and appears to have a pinhole leaking through the aft most band clamp. Both hose’s outer rubber layer are peeling back. Make hoses available for further inspection / replace the hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2023
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. STBD reduction gear control wire held to gear with zip ties. Repair to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
Flexible or portable cords cannot be used for permanently installed wiring. Power strip found mounted on stbd bridge bulkhead with refrigerator plugged in. Remove power strip.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Bridge power outlet found with hole drilled on left side for new cable run. Replace the outlet with a proper junction box to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
Flexible or portable cords cannot be used for permanently installed wiring. Power strips found “daisy chained” mounted in cuddy cabin overhead with various electrical devices plugged in. Remove power strips.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
Flexible or portable cords cannot be used for permanently installed wiring. Found extension cord strung through the cuddy cabin overhead to provide power to the above indicated “daisy chained” power strips. Remove extension cord.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
All commercial grade cables must be specifically approved for each installation. Found commercial portable lighting string (screw in bulb type) arranged around exterior deck, plugged into outlet. Remove lighting string.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
All commercial grade cables must be specifically approved for each installation. Found commercial portable lighting string (LED string type) arranged around interior deck, plugged into outlet. Remove lighting string.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
All cables installed where particularly liable to damage such as locations in way of doors, hatches etc. shall be specially protected by removable metal coverings, angle irons, pipe or other equivalent means. Cuddy cabin refrigerator cord runs through doorway to lower storage area and is subject to chaffing. Reroute power cable so that cable does not pass through door, to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
Electric cable for installation in a damp or wet location must be impervious sheathed. Found wire with chaffing penetrating the outer sheath just stbd and forward of the vessel’s generator on the overhead. Repair to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Found electrical “push pull” switch wired in and zip tied to deck support stbd side when accessing bilge through steering hatch. Identify and properly secure switch.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Port and Stbd main engines found with plastic trigger handles electrical taped together wired into to start system to provide local start capabilities for the engines. Start triggers dangle from the overhead by their cord. Properly secure switch.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Properly bundle and support wiring at the ends of the 6” PVC conduit leading from bilge to bridge, to prevent chaffing and excess heat generation. Remove dead end wiring.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
Batteries shall be secured against shifting with motion of the boat. Secure main engine start batteries.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Main engine start batteries found without protection to ensure a metal object cannot short across terminals. Provide protection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Copper pipe found kinked in the vicinity of the generator, on the port side of the bilge overhead. Repair to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 October 2023
Resolved
Provision shall be made by means of plugs, covers, etc to prevent the admission of air into the space protected by a fixed fire extinguishing system. Vessel is outfitted with duct tape to secure engine vents. Provide closure device to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2023
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Port main engine is leaking oil and found with diapers zip tied to the aft stbd side of the engine. Remove diapers and rectify leaks to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2023
Resolved
The manning for inspected vessel is subject to the discretion of the OCMI and the minimum qualifications of the crew on small passenger vessel not subject to STCW come from NVIC 1-91. The vessels Captain and crew could not show current proof of CPR/First Aid training, 50% of crew must be current in CPR/First Aid.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts, Coast Guard light list, and U.S. Coast Pilot, vessels charts and pubs were not up to date or on-board.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 30 May 2023
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: (1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Neither Master had their Marine Radio Operator permit available for inspection.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 30 May 2023
Resolved
Before getting underway for a voyage or soon after the master of the vessel shall ensure that a suitable public announcement are made informing passengers of safety items listed in 46CFR185.506, vessels safety announcement did not address all items list in the regulation.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 August 2022
Resolved
EACH VESSEL THAT OPERATES ON THE HIGH SEAS MUST HAVE ON BOARD A EPIRB INSTALLED TO AUTOMATICALLY FLOAT FREE AND ACTIVATE. HYDROSTATIC RELEASE ON EPIRB EXPIRED. ROUTE RESTRICTED TO 3 NM UNTIL RELEASE IS REPLACED.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2022
Resolved
EACH CHILD SIZE LIFE JACKET MUST BE STOWED IN A LOCATION THAT IS APPROPRIATELY MARKED AND SEPARATED FROM ADULT LIFE JACKETS SO THE CHILD SIZE LIFEJACKETS ARE NOT MISTAKEN FOR ADULT LIFEJACKETS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2022
Resolved
FLEXIBLE HOSE DESIGNED FOR USE WITH HOSE CLAMPS MAY BE INSTALLED WITH TWO CLAMPS. IDENTIFIED THE WASHDOWN PUMP HAD LOOSE/MISSING CLAMPS.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2022
Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION, THE MARINE INSPECTOR MAY REQUIRE THAT A MAN OVERBOARD DRILL BE HELD UNDER SIMULATED EMERGENCY CONDITIONS SPECIFIED BY THE INSPECTOR. WHILE PERFORMING MOB DRILL, [name withheld] TO COME DOWN TO THE MAIN DECK TO ASSIST IN RECOVERING THE PIW. INSPECTORS DETERMINED THIS IS A HAZARD TO NAVIGATION. SUBMIT MAN OVERBOARD PROCEDURES THAT DO NOT HAVE THE [name withheld] DECK.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 April 2021
Resolved
Managing operator shall be prepared for inspection of the hull structure and water tight bulkheads. Water ingress was observed on STBD side hull above the water line in the following locations, Engine compartment 12 frames aft between frames 12&13, 13&14, 16&17, 17&18 and outboard side of STBD MDE muffler. Please submit repair proposal and advise unit when next U/W trial is desired.
46CFR176.802 (a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2019
Resolved
Life rings do not have correct retroreflective tape. Cite: 46CFR160.050
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 May 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 May 2019
Resolved
Does not have record of monthly check for portable fire extinguishers. Cite: 46CFR176.810
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 May 2019
Resolved
Has one extension cord on bridge that is not boat cable. Cite: 46CFR183.340
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 May 2019
Resolved
Has one power strip on Bridge that is not marine type. Cite: 46CFR183.340
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2019
Resolved
Set of portable stairs on Bridge impeding life ring. Cite: 46CFR180.70
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2019
Resolved
Does not have pre-employment drug testing record for employees, record of random drug testing. Cite: 46CFR16
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 22 May 2019
Resolved
There is no MARPOL Placard. Cite: 33CFR151.59
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 May 2019
Resolved
Ambiance lighting impedes effectiveness of navigation lights.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2019
Resolved
Vessel has 3 of 5 wasted/cracked blocks (4x6) between tank and bottom frame under the aft portion of the port fuel tank that need to be replaced, must complete in the next 30 days.
Lifesaving › Lifefloat › Serviceable
Issued 12 June 2018
Resolved
Survival craft must be inspected monthly IAW manufacturer's instructions to ensure it is in complete and good order. Vessel's 15 person lifefloat must be repaired in accordance with manufacturer's recommendations.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 June 2018
Resolved
Each Type I PFD must have appropriate reflective material approved under 46 CFR 164.018. Retroreflective material on all PFD's is deteriorated and must be replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 June 2018
Resolved
In the event of a marine casualty, vessel's testing facility must be available within two hours or vessel must have alcohol testing capabilities onboard. Vessel's facility is not available within two hours, and does not have means to test for alcohol in the event of a marine casualty.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 12 June 2018
Resolved
Captain must provide marine radio operator permit.
Fire Fighting › Fire Bucket › Quantity
Issued 12 June 2018
Resolved
Vessels not required to have a fire pump must have three 2.5 gal fire buckets. Vessel only has two fire buckets and must provide a third.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 June 2018
Resolved
Vessel must carry a first aid kit in compliance with 46 CFR 160.041. Vessel must replace all expired items.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 July 2015
Resolved
AM01: Properly wire joints and splices in junction boxes. Old T 46CFR183.05-50(b)
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 June 2014
Resolved
JC01: Secure portable container on top deck (open) so securely fastened.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 June 2014
Resolved
JC05: Vessel must keep on board updated Lightlists.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 June 2014
Resolved
JC06: Vessel must properly fasten electrical wiring in E/R with metal clips.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 June 2014
Resolved
JC02: Vessel must provide a valid FCC Radiotelephony Certificate.
Documentation › Certificates/Documents › Stability Letter
Issued 9 June 2014
Resolved
JC03: Vessel must provide/post valid Stability Letter.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 June 2014
Resolved
JC04: Vessel must post COI visible to passengers.
Documentation › Logs/Records › Logbook (official)
Issued 9 June 2014
Resolved
JC07: Master must log monthly test of EPIRB operation.
Lifesaving › Buoyant Apparatus › Painter
Issued 15 May 2007
Resolved
Painter connecting two Buoyant Apparatus was wasted and of a non-UV resistant material.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 May 2007
Resolved
Due to weather conditions not able to complete Man Overboard Recovery drill.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 15 May 2007
Resolved
Replace Starboard side forward strut backing block.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 May 2006
Resolved
Properly mark the bilge High lvl alrams on the bridge.
Electrical › Electric Generation Source (service) › Panelboard
Issued 11 May 2006
Resolved
Properly repair/replace the voltmeter on the generator
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 11 May 2006
Resolved
Properly replace the hose from the thru hull to the faucet.
Lifesaving
Issued 16 April 2001
Resolved
DUE TO NEW LIFESAVING REGULATIONS EFFECTIVE 11 MARCH 2001, YOU VESSEL IS LIMITED TO 22 PASSENGERS (24 TOTAL PERSONS) ON A LIMITED COASTWISE ROUTE NOT MORE THAN 3 MILES FROM LAND AND 22 PASSENGERS (24 TOTAL PERSONS) ON THEDELAWARE BY. THIS RESTRICTION REMAINS IN EFFECT UNTIL 31MAY01.
Construction/Loadline
Issued 27 May 1999
Resolved
INSTALL A BILGE HIGH LEVEL ALARM IN THE COMPARTMENT FORWARD OF THE COLLISION BULKHEAD.
Lifesaving
Issued 21 May 1996
Resolved
PRIOR TO CARRYING PASSENGERS CONDUCT AN UNDERWAY EXAM.
Engineering
Issued 26 May 1995
Resolved
SUBMIT A PROPOSAL FOR INSTALLING A LOW ENGINEROOM VENT, AS REQUIRED BY 46 CFR 182.20-45, AND INSTALL THE VENT WITH THE DETAILS APPROVED BY THE COGNIZANT OCMI.
Documentation
Issued 26 May 1995
Resolved
PROVIDE DOCUMENTATION THAT THE REQUIRED "USCG DRUG AND ALCOHOL TESTING MIS DATA COLLECTION FORM" FOR THE YEAR 1994 HAS BEEN SUBMITTED TO USCG HEADQUARTERS (G-MMI).
Construction/Loadline
Issued 12 May 1994
Resolved
PROVIDE MANUFACTURER SUPPORTING DOCUMENTATION THAT DAVIS SLICK SEAM CAN BE USED AS PERMANENT REPAIR FOR INGRESS OF WATER THROUGH HULL.
Lifesaving
Issued 2 June 1992
Resolved
REPLACE ONE CHILDS LIFEJACKET FOUND TORN WITH APPROVED/EXCEPTABLE LIFE-_x001C_ JACKET IN KIND.
Accommodation/Occupational Safety
Issued 2 June 1992
Resolved
MAKE NECESSARY REPAIRS TO WOMENS MSD TO MAKE OPERATIONAL.
Fire Fighting
Issued 2 June 1992
Resolved
HAVE THREE (03) DRY CHEMICAL FIRE EXTINGUIHERS ONBOARD SERVICED OR REPLACEDIN KIND WITH SERVICED EXTINGUISHERS.
Navigation
Issued 2 June 1992
Resolved
PROVIDE ONBOARD CURRENT EDITIONS OF ALL REQUIRED NAVIGATION CHARTS FOR _x001C_ CERTIFICATED ROUTE.
Navigation
Issued 2 June 1992
Resolved
REPLACE NAVIGATION RULES OF THE ROAD PUBLICATION WITH CURRENT EDITION.
Navigation
Issued 14 May 1986
Resolved
PROVIDE ON BOARD THE CURRENT EDITION OF COAST PILOT.
Construction/Loadline
Issued 1 April 1986
Resolved
PLUG HOLES IN COLLISION BULKHEAD.
Electrical
Issued 1 April 1986
Resolved
REMOVE TWIST ELECTRICAL CONNECTIONS AND PROPERLY CONNECT.
Navigation
Issued 17 May 1985
Resolved
PROVIDE UP TO DATE CHARTS TO COVER ENTIRE ROUTE OF OPERATION.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.