MAURY USCG vessel records Sign in
← All vessels

ISLAND GIRL

ISLAND GIRL is a 1978 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1985, most recently in April 2026, along with 86 deficiencies and 1 operational control.

Records from 1985 to 2026. Most recent: inspection, 28 April 2026.

Built
1978
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG8832
Flag
UNITED STATES
367581510
Maury page id
psix-49700

Inspections, by type

…with no type recorded8
Years with a record 38 calendar years (1985–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.2 ft × 16.8 ft × 6.4 ft
Registered tonnagegross 41 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSIBLEY'S BOAT SHOP · DELTAVILLE, VA, UNITED STATES · built 1978
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 4 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR3084MMSI 367581510 · active · compulsorily equipped · granted 13 July 2026, expires 13 July 2036
WDG8832MMSI 367581510 · cancelled · compulsorily equipped · granted 2 June 2023, cancelled 12 February 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDC4948MMSI 367033280 · expired · compulsorily equipped · granted 13 April 2005, cancelled 13 June 2015 · licensed under a name not among this hull’s recorded names (not shown)
WAD9416MMSI not assigned · expired · compulsorily equipped · granted 10 August 1994, cancelled 9 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

28 April 2026 Vessel Attendance · In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8357350
22 April 2025 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8097604
23 July 2024 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7946339
12 October 2023 Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7798835
30 May 2023 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7697036
20 March 2023 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7653397
1 August 2022 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7521887
12 April 2021 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7175264
15 July 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7006928
22 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6692305
16 May 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6686187
12 June 2018 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6441417
10 May 2017 Annual Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6156176
14 February 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6089432
16 January 2016 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5829021
15 October 2015 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5743074
22 July 2015 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5192315
10 June 2014 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4884361
31 August 2011 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4131857
22 February 2010 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3686084
27 May 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3219063
29 April 2008 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3194797
15 May 2007 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2930778
20 April 2006 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2628913
26 April 2004 Annual Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2052834
13 June 2003 Type not recorded
No type recorded · Station Philadelphia · USCG East District (CGD-E) · Activity 1817114
21 May 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1797275
21 April 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1773587
14 May 2002 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1616270
10 August 2001 Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1070801
22 May 2001 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1063454
16 April 2001 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1062312
25 May 2000 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1049834
14 July 1999 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1096783
27 May 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 803519
30 April 1999 Plan Review "T" Boat · COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1360838
14 August 1998 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1437439
28 May 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1107876
30 August 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 938810
21 May 1996 Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1082637
30 April 1996 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1085913
26 May 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 924960
13 June 1994 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324758
12 May 1994 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1161424
12 May 1994 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1382781
1 June 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1458102
2 June 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1255603
5 May 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1256930
28 May 1991 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1319805
7 May 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1215130
20 April 1990 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1227549
18 August 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1339952
18 August 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1347819
16 May 1989 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888363
10 April 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888635
17 May 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888969
28 March 1988 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036018
21 May 1987 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1001685
21 April 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1018745
11 July 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 998895
14 May 1986 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1294014
1 April 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306547
9 September 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 991451
28 May 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983730
17 May 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1291521
15 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1290578

Deficiency record · 86

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2026 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for the annual inspection. Conduct annual inspection prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2026
Resolved 12 June 2026
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 31 May 2024 Resolved
Each vessel in each condition of loading and operation shall comply with intact stability requirements. Due to historical cummulative weight changes, the vessel is required to complete a new simplified stability test. Temp ops authorized w/reduced passengers (29) and reduced route (protected).
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 12 June 2026
Resolution: Pax count reduced on COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. During sea trial, noted excessive vibration of both propeller shafts as well as apparent chaffing of the shafts due to alignment. Make shafts available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2023
Resolved 7 June 2024
Resolution: Shafts replaced in kind to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 October 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. During sea trials, observed fuel leak from STBD Main Engine fuel connection point.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2023
Resolved 7 June 2024
Resolution: Cracked fuel pump replaced to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. During sea trials, discovered hole in port MDE exhaust hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2023
Resolved 7 June 2024
Resolution: Exhaust hose replaced to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Port red gear missing vent cap. Replace cap.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2023
Resolved 4 June 2024
Resolution: Cap replaced to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 October 2023 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. Fixed CO2 operating instructions are incorrect. Update to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2023
Resolved 7 June 2024
Resolution: CO2 instructions updated to the satisfaction of the reviewing Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2023 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Cuddy Cabin portable fire extinguisher found without stock hanger. Provide proper hanger for extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2023
Resolved 4 June 2024
Resolution: Extinguisher replaced to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 October 2023 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. The use of plastic tie wraps must be limited to bundling. Secure wiring runs below deck with metal supports in lieu of plastic.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2023
Resolved 4 June 2024
Resolution: Wires supported with metal retainers to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 October 2023 Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice or extending the length of a circuit. Wire nuts found connecting a light in the cuddy cabin. Remove and remake splice to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2023
Resolved 4 June 2024
Resolution: Rectified to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 October 2023 Resolved
Fuel supply piping shall be of copper, nickel copper or copper nickel having a minimum wall thickness of 0.035 inch. Generator copper fuel return line is kinked. Replace to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2023
Resolved 26 October 2023
Resolution: Vessel rep replaced copper pipe and fittings to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 October 2023 Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings. Generator fuel supply hose connection found with a single hose clamp. Provide two hose clamps to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2023
Resolved 7 June 2024
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 October 2023 Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings. Generator fuel return hose connection found with single hose clamps. Renew return hose and provide two hose clamps per end to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2023
Resolved 26 October 2023
Resolution: Vessel rep replaced hose to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2023 Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings. STBD Main Engine fuel supply hose connections found without hose clamps. Provide two hose clamps to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2023
Resolved 26 October 2023
Resolution: Vessel rep replaced hoses to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Vessel’s shaft log / packing box hoses are heavily deteriorated. Port hose is bulging with an apparent rip in the outer banding. Stbd hose rubber is failing and appears to have a pinhole leaking through the aft most band clamp. Both hose’s outer rubber layer are peeling back. Make hoses available for further inspection / replace the hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 7 June 2024
Resolution: Both hoses replaced, stbd log replaced, to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. STBD reduction gear control wire held to gear with zip ties. Repair to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2023
Resolved 26 October 2023
Resolution: Vessel rep replaced connection point and removed zip ties to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
Flexible or portable cords cannot be used for permanently installed wiring. Power strip found mounted on stbd bridge bulkhead with refrigerator plugged in. Remove power strip.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 4 June 2024
Resolution: Removed to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Bridge power outlet found with hole drilled on left side for new cable run. Replace the outlet with a proper junction box to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 4 June 2024
Resolution: Chaffing/clamping device installed to prevent chaff and movement to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
Flexible or portable cords cannot be used for permanently installed wiring. Power strips found “daisy chained” mounted in cuddy cabin overhead with various electrical devices plugged in. Remove power strips.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 26 October 2023
Resolution: Vessel rep removed power strips.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
Flexible or portable cords cannot be used for permanently installed wiring. Found extension cord strung through the cuddy cabin overhead to provide power to the above indicated “daisy chained” power strips. Remove extension cord.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 26 October 2023
Resolution: Vessel rep removed extension cords.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
All commercial grade cables must be specifically approved for each installation. Found commercial portable lighting string (screw in bulb type) arranged around exterior deck, plugged into outlet. Remove lighting string.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 26 October 2023
Resolution: Vessel rep removed lighting string.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
All commercial grade cables must be specifically approved for each installation. Found commercial portable lighting string (LED string type) arranged around interior deck, plugged into outlet. Remove lighting string.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 26 October 2023
Resolution: Vessel rep removed lighting string.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
All cables installed where particularly liable to damage such as locations in way of doors, hatches etc. shall be specially protected by removable metal coverings, angle irons, pipe or other equivalent means. Cuddy cabin refrigerator cord runs through doorway to lower storage area and is subject to chaffing. Reroute power cable so that cable does not pass through door, to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 4 June 2024
Resolution: Cord re-routed to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
Electric cable for installation in a damp or wet location must be impervious sheathed. Found wire with chaffing penetrating the outer sheath just stbd and forward of the vessel’s generator on the overhead. Repair to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 4 June 2024
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Found electrical “push pull” switch wired in and zip tied to deck support stbd side when accessing bilge through steering hatch. Identify and properly secure switch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 4 June 2024
Resolution: Switch is for remote fresh water pump. Replaced and properly secured to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Port and Stbd main engines found with plastic trigger handles electrical taped together wired into to start system to provide local start capabilities for the engines. Start triggers dangle from the overhead by their cord. Properly secure switch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 4 June 2024
Resolution: Switches properly secured to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Properly bundle and support wiring at the ends of the 6” PVC conduit leading from bilge to bridge, to prevent chaffing and excess heat generation. Remove dead end wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 4 June 2024
Resolution: Dead end wires removed, remaining wires bundled to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
Batteries shall be secured against shifting with motion of the boat. Secure main engine start batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 26 October 2023
Resolution: Batteries have been secured with wooden blocks.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Main engine start batteries found without protection to ensure a metal object cannot short across terminals. Provide protection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 4 June 2024
Resolution: Batteries secured in boxes to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Copper pipe found kinked in the vicinity of the generator, on the port side of the bilge overhead. Repair to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 4 June 2024
Resolution: Copper pipe is steering hydraulics. Pipe was repaired by service technician to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 October 2023 Resolved
Provision shall be made by means of plugs, covers, etc to prevent the admission of air into the space protected by a fixed fire extinguishing system. Vessel is outfitted with duct tape to secure engine vents. Provide closure device to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 7 June 2024
Resolution: Plywood blanks installed over vents to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2023 Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Port main engine is leaking oil and found with diapers zip tied to the aft stbd side of the engine. Remove diapers and rectify leaks to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2023
Resolved 26 October 2023
Resolution: Diapers have been removed, no apparent leaks at the time of re-inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2023 Resolved
The manning for inspected vessel is subject to the discretion of the OCMI and the minimum qualifications of the crew on small passenger vessel not subject to STCW come from NVIC 1-91. The vessels Captain and crew could not show current proof of CPR/First Aid training, 50% of crew must be current in CPR/First Aid.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 12 July 2023
Resolution: Master provided proof of CPR/First Aid training.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 May 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts, Coast Guard light list, and U.S. Coast Pilot, vessels charts and pubs were not up to date or on-board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 12 July 2023
Resolution: Vessel purchased new charts, List List, and US Coast Pilot.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 30 May 2023 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: (1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Neither Master had their Marine Radio Operator permit available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 12 July 2023
Resolution: Master provided Marine Radio Operator permit.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 30 May 2023 Resolved
Before getting underway for a voyage or soon after the master of the vessel shall ensure that a suitable public announcement are made informing passengers of safety items listed in 46CFR185.506, vessels safety announcement did not address all items list in the regulation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 12 July 2023
Resolution: Vessel has an updated safety announcement.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 August 2022 Resolved
EACH VESSEL THAT OPERATES ON THE HIGH SEAS MUST HAVE ON BOARD A EPIRB INSTALLED TO AUTOMATICALLY FLOAT FREE AND ACTIVATE. HYDROSTATIC RELEASE ON EPIRB EXPIRED. ROUTE RESTRICTED TO 3 NM UNTIL RELEASE IS REPLACED.
Action required: 705 - Other - as specified
Due 16 August 2022
Resolved 8 September 2022
Resolution: Recieved satisfactory photographic evidence. See deficiencies documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2022 Resolved
EACH CHILD SIZE LIFE JACKET MUST BE STOWED IN A LOCATION THAT IS APPROPRIATELY MARKED AND SEPARATED FROM ADULT LIFE JACKETS SO THE CHILD SIZE LIFEJACKETS ARE NOT MISTAKEN FOR ADULT LIFEJACKETS.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 August 2022
Resolved 16 August 2022
Resolution: Recieved satisfactory photographic evidence. See deficiencies documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2022 Resolved
FLEXIBLE HOSE DESIGNED FOR USE WITH HOSE CLAMPS MAY BE INSTALLED WITH TWO CLAMPS. IDENTIFIED THE WASHDOWN PUMP HAD LOOSE/MISSING CLAMPS.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2022
Resolved 16 August 2022
Resolution: Recieved satisfactory photographic evidence. See deficiencies documents tab.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2022 Resolved
AT EACH INITIAL AND SUBSEQUENT INSPECTION FOR CERTIFICATION, THE MARINE INSPECTOR MAY REQUIRE THAT A MAN OVERBOARD DRILL BE HELD UNDER SIMULATED EMERGENCY CONDITIONS SPECIFIED BY THE INSPECTOR. WHILE PERFORMING MOB DRILL, [name withheld] TO COME DOWN TO THE MAIN DECK TO ASSIST IN RECOVERING THE PIW. INSPECTORS DETERMINED THIS IS A HAZARD TO NAVIGATION. SUBMIT MAN OVERBOARD PROCEDURES THAT DO NOT HAVE THE [name withheld] DECK.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2022
Resolved 16 August 2022
Resolution: Recieved satisfactory photographic evidence. See deficiencies documents tab.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 April 2021 Resolved
Managing operator shall be prepared for inspection of the hull structure and water tight bulkheads. Water ingress was observed on STBD side hull above the water line in the following locations, Engine compartment 12 frames aft between frames 12&13, 13&14, 16&17, 17&18 and outboard side of STBD MDE muffler. Please submit repair proposal and advise unit when next U/W trial is desired. 46CFR176.802 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2021
Resolved 19 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2019 Resolved
Life rings do not have correct retroreflective tape. Cite: 46CFR160.050
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 2 July 2019
Resolution: Retro tape applied.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 May 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 2 July 2019
Resolution: All pubs aquired.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 May 2019 Resolved
Does not have record of monthly check for portable fire extinguishers. Cite: 46CFR176.810
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 28 May 2019
Resolution: Successfully checked and logged.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 May 2019 Resolved
Has one extension cord on bridge that is not boat cable. Cite: 46CFR183.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 2 July 2019
Resolution: Extension cord removed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 May 2019 Resolved
Has one power strip on Bridge that is not marine type. Cite: 46CFR183.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 2 July 2019
Resolution: Removed pwr strip
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2019 Resolved
Set of portable stairs on Bridge impeding life ring. Cite: 46CFR180.70
Action required: 10 - Deficiency Rectified
Due 22 May 2019
Resolved 22 May 2019
Resolution: Safely relocated portable stairs to appropriate storage location.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2019 Resolved
Does not have pre-employment drug testing record for employees, record of random drug testing. Cite: 46CFR16
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 28 May 2019
Resolution: Provided pre-employment and random drug test paperwork.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 22 May 2019 Resolved
There is no MARPOL Placard. Cite: 33CFR151.59
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 2 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 May 2019 Resolved
Ambiance lighting impedes effectiveness of navigation lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 2 July 2019
Resolution: Lights were removed and any remaining will not be used during underway operations.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2019 Resolved
Vessel has 3 of 5 wasted/cracked blocks (4x6) between tank and bottom frame under the aft portion of the port fuel tank that need to be replaced, must complete in the next 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 22 May 2019
Resolution: Replaced in kind
Lifesaving › Lifefloat › Serviceable
Issued 12 June 2018 Resolved
Survival craft must be inspected monthly IAW manufacturer's instructions to ensure it is in complete and good order. Vessel's 15 person lifefloat must be repaired in accordance with manufacturer's recommendations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2018
Resolution: Operator made proper repairs to life float.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 June 2018 Resolved
Each Type I PFD must have appropriate reflective material approved under 46 CFR 164.018. Retroreflective material on all PFD's is deteriorated and must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2018
Resolution: Deteriorated retro-reflective materials replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 June 2018 Resolved
In the event of a marine casualty, vessel's testing facility must be available within two hours or vessel must have alcohol testing capabilities onboard. Vessel's facility is not available within two hours, and does not have means to test for alcohol in the event of a marine casualty.
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 20 June 2018
Resolution: Vessel provided test kits.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 12 June 2018 Resolved
Captain must provide marine radio operator permit.
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 18 June 2018
Resolution: Captain provided marine radio operator permit dated 11/23/09 with no expiration.
Fire Fighting › Fire Bucket › Quantity
Issued 12 June 2018 Resolved
Vessels not required to have a fire pump must have three 2.5 gal fire buckets. Vessel only has two fire buckets and must provide a third.
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 20 June 2018
Resolution: Vessel provided third bucket.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 June 2018 Resolved
Vessel must carry a first aid kit in compliance with 46 CFR 160.041. Vessel must replace all expired items.
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 20 June 2018
Resolution: Vessel provided new first aid kit.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 July 2015 Resolved
AM01: Properly wire joints and splices in junction boxes. Old T 46CFR183.05-50(b)
Due 17 August 2015
Resolved 21 August 2015
Resolution: Wire joints properly secured in junction boxes.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 June 2014 Resolved
JC01: Secure portable container on top deck (open) so securely fastened.
Due 24 June 2014
Resolved 17 July 2014
Resolution: JC01: Dock box moved to inboard the wheel house "wings." In this location the dock box will not be able slide off the top deck in any rough sea condition.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 June 2014 Resolved
JC05: Vessel must keep on board updated Lightlists.
Due 24 June 2014
Resolved 17 July 2014
Resolution: Vessel Rep. downloaded latest light list for sector and printed out the pages relevant to the MARINERS cruising area. The light list will be kept in the wheel house with the charts.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 June 2014 Resolved
JC06: Vessel must properly fasten electrical wiring in E/R with metal clips.
Due 24 June 2014
Resolved 17 July 2014
Resolution: Vessel Rep installed 4 new insulated wire hangers in the area forward of the port engine.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 June 2014 Resolved
JC02: Vessel must provide a valid FCC Radiotelephony Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2014
Resolution: JC02: Vessel retrieved valid FCC Radiotelephony Certificate.
Documentation › Certificates/Documents › Stability Letter
Issued 9 June 2014 Resolved
JC03: Vessel must provide/post valid Stability Letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2014
Resolution: JC03: Vessel Rep. found old Stability Letter. Issued Addendum to Stability Letter to reflect passenger count on COI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 June 2014 Resolved
JC04: Vessel must post COI visible to passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2014
Resolution: JC04: Vessel Rep. posted valid COI
Documentation › Logs/Records › Logbook (official)
Issued 9 June 2014 Resolved
JC07: Master must log monthly test of EPIRB operation.
Action required: 15 - Rectify deficiencies by next port
Resolved 10 June 2014
Resolution: JC07: Deficiency corrected on the spot. Master notified.
Lifesaving › Buoyant Apparatus › Painter
Issued 15 May 2007 Resolved
Painter connecting two Buoyant Apparatus was wasted and of a non-UV resistant material.
Condition: Improper/Lack of Maintenance
Due 15 June 2007
Resolved 31 May 2007
Resolution: Installed appropriate UV resistant line connecting Buoyant Apparatus.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 May 2007 Resolved
Due to weather conditions not able to complete Man Overboard Recovery drill.
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 6 June 2007
Resolution: Completed satisfactory Manoverboard and fire drill.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 15 May 2007 Resolved
Replace Starboard side forward strut backing block.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2007
Resolution: Replaced Starboard side forward strut backing block.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 May 2006 Resolved
Properly mark the bilge High lvl alrams on the bridge.
Due 25 May 2006
Resolved 23 May 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 11 May 2006 Resolved
Properly repair/replace the voltmeter on the generator
Due 25 May 2006
Resolved 23 May 2006
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 11 May 2006 Resolved
Properly replace the hose from the thru hull to the faucet.
Due 25 May 2006
Resolved 23 May 2006
Lifesaving
Issued 16 April 2001 Resolved
DUE TO NEW LIFESAVING REGULATIONS EFFECTIVE 11 MARCH 2001, YOU VESSEL IS LIMITED TO 22 PASSENGERS (24 TOTAL PERSONS) ON A LIMITED COASTWISE ROUTE NOT MORE THAN 3 MILES FROM LAND AND 22 PASSENGERS (24 TOTAL PERSONS) ON THEDELAWARE BY. THIS RESTRICTION REMAINS IN EFFECT UNTIL 31MAY01.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 27 May 1999 Resolved
INSTALL A BILGE HIGH LEVEL ALARM IN THE COMPARTMENT FORWARD OF THE COLLISION BULKHEAD.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Lifesaving
Issued 21 May 1996 Resolved
PRIOR TO CARRYING PASSENGERS CONDUCT AN UNDERWAY EXAM.
Condition: Unknown
Due 30 May 1996
Resolved 24 May 1996
Engineering
Issued 26 May 1995 Resolved
SUBMIT A PROPOSAL FOR INSTALLING A LOW ENGINEROOM VENT, AS REQUIRED BY 46 CFR 182.20-45, AND INSTALL THE VENT WITH THE DETAILS APPROVED BY THE COGNIZANT OCMI.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Documentation
Issued 26 May 1995 Resolved
PROVIDE DOCUMENTATION THAT THE REQUIRED "USCG DRUG AND ALCOHOL TESTING MIS DATA COLLECTION FORM" FOR THE YEAR 1994 HAS BEEN SUBMITTED TO USCG HEADQUARTERS (G-MMI).
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Construction/Loadline
Issued 12 May 1994 Resolved
PROVIDE MANUFACTURER SUPPORTING DOCUMENTATION THAT DAVIS SLICK SEAM CAN BE USED AS PERMANENT REPAIR FOR INGRESS OF WATER THROUGH HULL.
Condition: Unknown
Due 27 May 1994
Resolved 31 May 1994
Lifesaving
Issued 2 June 1992 Resolved
REPLACE ONE CHILDS LIFEJACKET FOUND TORN WITH APPROVED/EXCEPTABLE LIFE-_x001C_ JACKET IN KIND.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Accommodation/Occupational Safety
Issued 2 June 1992 Resolved
MAKE NECESSARY REPAIRS TO WOMENS MSD TO MAKE OPERATIONAL.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Fire Fighting
Issued 2 June 1992 Resolved
HAVE THREE (03) DRY CHEMICAL FIRE EXTINGUIHERS ONBOARD SERVICED OR REPLACEDIN KIND WITH SERVICED EXTINGUISHERS.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Navigation
Issued 2 June 1992 Resolved
PROVIDE ONBOARD CURRENT EDITIONS OF ALL REQUIRED NAVIGATION CHARTS FOR _x001C_ CERTIFICATED ROUTE.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Navigation
Issued 2 June 1992 Resolved
REPLACE NAVIGATION RULES OF THE ROAD PUBLICATION WITH CURRENT EDITION.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Navigation
Issued 14 May 1986 Resolved
PROVIDE ON BOARD THE CURRENT EDITION OF COAST PILOT.
Condition: Unknown
Due 14 May 1986
Resolved 14 May 1986
Construction/Loadline
Issued 1 April 1986 Resolved
PLUG HOLES IN COLLISION BULKHEAD.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Electrical
Issued 1 April 1986 Resolved
REMOVE TWIST ELECTRICAL CONNECTIONS AND PROPERLY CONNECT.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Navigation
Issued 17 May 1985 Resolved
PROVIDE UP TO DATE CHARTS TO COVER ENTIRE ROUTE OF OPERATION.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.