Inspection history · 72
12 May 2025
Periodic Inspection · MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8133181
29 April 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7904778
11 April 2024
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7891595
11 March 2024
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7877296
15 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7689296
10 May 2022
MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7438846
20 May 2021
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7202982
21 January 2021
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7128625
23 December 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7115384
18 May 2020
MARPOL Annex VI Survey · Periodic Inspection · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6955656
9 May 2019
MTSA Verification · Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6680678
8 May 2018
MTSA Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6409788
11 May 2017
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6142635
27 April 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5864259
25 March 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5842120
12 May 2015
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5122887
26 February 2015
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5119614
28 April 2014
Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4846138
10 May 2012
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4299543
27 April 2010
Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3725673
14 May 2009
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3477939
12 April 2009
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3453474
2 June 2008
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3225233
14 May 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3206233
11 May 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2928034
25 May 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2658983
11 May 2005
Annual Inspection · Hull Examination · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2355119
12 April 2004
Periodic Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2059252
2 February 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2004575
9 June 2003
In-Service Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1813503
14 April 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1771154
4 April 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1601244
3 April 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1387016
12 March 2001
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1064521
3 April 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403097
18 May 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1131857
5 April 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1436197
12 March 1999
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1375662
6 April 1998
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1428932
4 November 1997
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1438660
24 July 1997
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 63727
14 April 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1459306
22 March 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1456452
5 November 1996
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371637
20 May 1996
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1083831
22 April 1996
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363605
12 March 1996
Damage Survey · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1367699
25 May 1995
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 871918
10 April 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1154741
22 March 1995
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1430015
23 February 1995
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1401982
29 April 1994
Examination of Repairs · COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1362972
19 May 1993
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1366848
19 May 1992
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1259876
4 October 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 944028
9 August 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 933083
21 June 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 899984
11 June 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1210761
3 May 1991
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1226490
15 June 1990
Initial Construction-Excluding Oversight · COI Inspection · Construction Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1222663
18 October 1989
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1353039
17 October 1989
Hull Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1040454
2 December 1988
Drydock Extension · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1208307
4 January 1988
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1315713
25 November 1987
COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1005010
12 June 1987
Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1028861
27 June 1986
Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1305755
9 January 1986
Examination of Repairs · Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301868
10 May 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1291053
5 April 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278785
13 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273631
10 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276235
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2025
Resolved
Each lifejacket must have a lifejacket light.
Batteries for lifejacket lights are marked as expired in 2021. Replace lights for the 6 lifejackets with the proper 3V lithium ion batteries to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 27 May 2025
Resolution: Attending Marine Inspector confirmed that all new lifejackets lights had been purchased and provided onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 May 2025
Resolved
Each immersion suit must be marked in such a way as to identify the person or vessel to which it belongs.
Mark/stencil the 6 immersion suits with the vessel’s name to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 27 May 2025
Resolution: Attending Marine Inspector confirmed that vessel name had been stencilled on all immersion suits.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 May 2025
Resolved
At each periodic inspection, all watertight doors shall be operated.
Dogs on "bow door" WTD leading into the hopper are seized and very difficult to move. Grease/free up and demonstrate proper operation to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 27 May 2025
Resolution: Attending Marine Inspector confirmed that all dogs had been greased/overhauled and operate smoothly and freely at this time.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2025
Resolved
Lighting fixtures: no fixture may be used as a connection box for a circuit other than the branch circuit supplying the fixture.
Lighting fixtures are being used as a connection box to power a camera in the starboard conveyor belt room, and heat tape for a water tank level indicator in the port side tunnel. Properly wire to the satisfaction of the attending Marine Inspector by next scheduled dry dock.
Action required: 705 - Other - as specified
Due 30 April 2026
Resolved 3 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 May 2025
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practical.
Several sections of structural fire protection insulation in the overhead of the generator room were removed for welding attachments for a container on the deck above. Additionally, a section of structural fire protection insulation is missing near the door between the generator room and electrical room. Replace all missing structural fire protection insulation to the satisfaction of the attending Marine Inspector by the
next scheduled dry dock.
Action required: 705 - Other - as specified
Due 30 April 2026
Resolved 3 June 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 May 2025
Resolved
The Oil Record Book Part I shall be completed on each occasion, on a tank-to-tank basis if appropriate, whenever any of the following machinery space operations takes place in a ship…
An ORB is not being maintained onboard. Start maintaining an ORB with all pertinent entries (example: bunkering of fuel oil) and present to the attending Marine Inspector at the upcoming dry dock.
Action required: 705 - Other - as specified
Due 30 April 2026
Resolved 3 June 2026
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 12 May 2025
Resolved
Bunker delivery notes shall be kept on board for a period of 3 years after the fuel oil has been delivered on board. The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered. The sample shall be retained under the ship’s control until the fuel oil is substantially consumed, but in any case for a period of not less than 12 months from the time of delivery.
Start maintaining BDNs and fuel samples onboard, and present to the attending Marine Inspector at the upcoming dry dock.
Action required: 705 - Other - as specified
Due 30 April 2026
Resolved 3 June 2026
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 April 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 160.041. Vessel has expired items in first aid kit. Vessel must replace all expired items in first aid kit.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 13 May 2024
Resolution: Tylenol receipt received.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 April 2024
Resolved
Each vessel operating three miles from shore must carry a category-1 406MHZ satellite EPIRB meeting the requirements of 47CFR80. EPIRB registration expired March 21, 2024. Vessel must provide updated registration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2024
Resolved 3 May 2024
Resolution: Updated EPIRB certificate sent. ALSAT.
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 29 April 2024
Resolved
All ships of 400 gross tonage and above carry an approved Shipboard Oil Pollution Emergency Plan. SOPEP Expired November 2023
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2024
Resolved 13 May 2024
Resolution: Copy of updated SOPEP sent.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2022
Resolved
Lights missing protective covers. Lighting needs to meet 46 CFR 111.75-20(a) as well as the guard required in 46 CFR 111.75-20 (b) for machinery/electrical spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 27 May 2022
Resolution: Installed light covers
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 May 2022
Resolved
Structural Fire Protection insulation removed from bulkhead/overhead. Replace with appropriate insulation.
46 CFR 92.05-15(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 27 May 2022
Resolution: Replaced missing SFP insulation
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 10 May 2022
Resolved
STBD Fuel oil vent found with rag as closure for containment. Containment needs a mechanical means of closing drain/scupper.
33 CFR 155.320
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 27 May 2022
Resolution: Installed mechanical containment plug
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 May 2019
Resolved
Current COD was not available onboard as required by 46 CFR 67.7. Vessel must obtain a current COD prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2019
Resolved 31 May 2019
Resolution: Received picture of COD onboard barge
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 12 May 2015
Resolved
Heat detecting sensors were not tested per annual requirement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2015
Resolution: Received satisfactory report indicating all heat sensors were operationally tested.
Engineering › Fuel Oil Service System › Filter
Issued 11 May 2007
Resolved
Metallic fuel oil filter shielding not in place for Diesel generators.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 May 2007
Resolution: Installed Metallic fuel oil filter shielding
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 11 May 2007
Resolved
Portable CO2 Fire Extinguishers need to be properly mounted or secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2007
Resolution: Properly mounted portable CO2 fire extinguishers.
Construction/Loadline
Issued 12 March 1999
Resolved
Issued requirement for vessel to provide a long term plan to address extensive grooving within the welds (Specificaly at stanchion to TWF and TWF stiffeners.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Construction/Loadline
Issued 23 February 1995
Resolved
COMPLETE REPAIRS TO #2,3 AND 4 PORT & STARBOARD VOIDS IN WAY OF CENTERLINE BULKHEAD. REPAIRS TO BE COMPLETED PRIOR TO LOADING CARGO BUT NO LATER THAN31MAR95.
Condition: Unknown
Due 23 February 1995
Resolved 23 February 1995
Construction/Loadline
Issued 4 October 1991
Resolved
CONDUCT PERMANENT REPAIRS TO FRACTURES AT CARGO BINWALL EXPANSION JOINTS ATNEXT DRYDOCK.
Condition: Unknown
Due 4 October 1991
Resolved 4 October 1991
Construction/Loadline
Issued 11 June 1991
Resolved
SUBMIT PROPOSAL FOR PERMANENT REPAIRS TO FRACTURES AT CARGO BIN EXPANSION JOINTS.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Construction/Loadline
Issued 11 June 1991
Resolved
CONDUCT VISUAL INSPECTION OF SAFE-ENDED FRACTURES AT CARGO BIN EXPANSION JOINTS. RESULTS OF INSPECTION TO BE DOCUMENTED AN PROVIDED VIA LETTER TO [name withheld].
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Deck/Cargo
Issued 25 November 1987
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF PUMP GENERATOR AND ALL ITS SAFETY DEVICES SUCH AS OVERSPEED TRIP, LOW LUBE OIL SHUT-DOWN, ETC.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Navigation
Issued 25 November 1987
Resolved
OPEN PORT RUNNING LIGHT BATTERY BOX FOR INSPECTION.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Construction/Loadline
Issued 25 November 1987
Resolved
LOWER RAMP TO STEEPEST DOWNWARD SLOPE USED, MAKING CABLE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Navigation
Issued 25 November 1987
Resolved
WIRE PINS IN SHACKLES AND STAKE, WIRE, PIN, LOCK OR WELD AND BOLT/NUT COMBINATIONS NOT ALREADY SO SECURED THROUGHOUT RAMP HANDLING TACKLE.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Fire Fighting
Issued 25 November 1987
Resolved
SERVICE PORTABLE AND SEMIPORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Construction/Loadline
Issued 25 November 1987
Resolved
VEE OUT AND RE-WELD CRACKED FILLET WELDS IN WAY OF DENT INSIDE SHELL NO.3 STARBOARD TANK.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Navigation
Issued 25 November 1987
Resolved
STRAIGHTEN PORT RUNNING LIGHT SHIELD.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Construction/Loadline
Issued 12 June 1987
Resolved
INVESTIGATE SOURCE OF FRESH WATER IN STBD COMPARTMENTS FWD AND AFT OF FRESH WATER CARGO TANK.
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Fire Fighting
Issued 12 June 1987
Resolved
SERVICE PORTABLE FIRE EXTINGUISHER
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Construction/Loadline
Issued 9 January 1986
Resolved
MAKE PERMANENT REPAIRS TO BOW IN WAY OF PORT SIDE FROM FRAME 1 TO 2 1/2. REPAIRS ARE TO BE ACCOMPLISHED PRIOR TO END OF NEXT DRYDOCK INSPECTION.
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986