TIONA is a 1999 freight ship. The Coast Guard has recorded 25 inspections since 1999, most recently in May 2012, along with 8 deficiencies and 11 operational controls, 3 with no removal date recorded.

Records from 1999 to 2012. Most recent: inspection, 5 May 2012.

Built
1999
Last inspected
5 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
3 with no removal date recorded

Identity

9193824 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D6A2052
497325
Flag
NETHERLANDS
—
Maury page id
psix-497325

Inspections, by type

…with no type recorded10
Years with a record 9 calendar years (1999–2012)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6023 - Dead Weight, Ton
8813 - Displacement, Ton
4251 - Convention (Subpart B), Gross Ton
4251 - Regulatory (Subpart C or D), Gross Ton
2189 - Convention (Subpart B), Net Ton
2189 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

5 May 2012 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4302575
19 February 2012 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4247218
8 February 2012 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4239274
24 January 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3668174
12 February 2005 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2290281
9 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2289675
4 December 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2253441
1 December 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2255636
29 November 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2253551
2 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2119161
29 June 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2115417
19 April 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2047810
10 April 2004 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2041339
6 April 2004 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2038528
5 April 2004 Periodic Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2037583
4 April 2004 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2039091
16 January 2004 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1986874
1 August 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1868179
17 July 2002 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1647784
5 July 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1641918
7 May 2002 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1613791
20 December 2001 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1473676
24 June 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 294619
19 July 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280109
24 June 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 430491

Deficiency record · 8

Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 5 May 2012 Resolved
1430 U.S. Coast Guard port state control officers attended vessel as the result of a reportable marine casualty as defined by Title 46 Code of Federal Regulations, Part 4. Vessel was unable to depart the port of Lake Charles, LA using the diesel generator used to safely maneuver in the ship channel. Vessel is to provide class society report attesting to the proper operation of the generator to
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2012
Resolution: Vessel submitted class document attesting to proper of the No. 1 auxiliary Engine.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 February 2012 Resolved
0715 Fire detection systems and fire alarm systems shall be kept in good order so as to ensure their required performance. 74 SOLAS 09 Cons. Ed. Chapter II-2 Regualtion 14.2.1.1. See Form B and narrative for further details.
Action required: 705 - Other - as specified
Due 8 February 2012
Resolved 8 February 2012
Resolution: Crew removed tape and conducted test of all smoke alarms in engine room to ensure proper operation.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 February 2012 Resolved
1230 Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks.See form B and narrative for details.
Action required: 15 - Rectify deficiencies by next port
Due 11 February 2012
Resolved 21 February 2012
Resolution: Captain provided pictures of repair to hand rail.
Construction/Loadline › Hull › Side Shell
Issued 19 April 2004 Resolved
Port side anchor pocket has approximately a five inch crack through the hull.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2004
Resolved 19 April 2004
Resolution: Class attested to the temporary repairs to the port side anchor pocket and faxed a copy of the survey to MSO Houston.
Deck/Cargo
Issued 19 April 2004 Resolved
Hazmat placards located on empty containers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2004
Resolved 19 April 2004
Resolution: Placards were removed and violation process was carried out.
Construction/Loadline › Hull
Issued 5 April 2004 Resolved
Port side anchore pocket has aproximately a five inch crack thru the hull. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2004
Resolved 7 April 2004
Resolution: Class attended vessel. Temperary repairs were made and vessel was allowed to depart.
Engineering › Freshwater System (air cooling) › Discharge Strainer
Issued 6 May 2002 Resolved
Ship lost power due to engine cooling problems.
Condition: Improper/Lack of Maintenance
Due 6 May 2002
Resolved 7 May 2002
Resolution: Ship cleaned strainer.
Navigation › Piloting/Steering
Issued 20 December 2001 Resolved
Inoperable gyro compass LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2001
Resolved 23 December 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.