← All vessels
CABO VERDE
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named CABO VERDE
CABO VERDE is a 1976 freight ship. The Coast Guard has recorded 9 inspections since 1999, most recently in June 2001, along with 33 deficiencies and 1 operational control.
Records from 1999 to 2001. Most recent: inspection, 20 June 2001.
- Built
- 1976
- Last inspected
- 20 June 2001
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 33 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7519907 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FKW9
497327
Flag
PANAMA
—
Maury page id
psix-497327
Inspections, by type
…with no type recorded9
Years with a record
3 calendar years (1999–2001)
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6305 - Dead Weight, Ton
3400 - Regulatory (Subpart C or D), Gross Ton
2240 - Regulatory (Subpart C or D), Net Ton
3400 - Regulatory (Subpart C or D), Gross Ton
2240 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 9
20 June 2001
Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 640601
10 April 2001
Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 288664
29 June 2000
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 279281
21 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 277117
25 August 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 538495
29 June 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 430154
29 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 722829
5 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 188471
3 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 429744
Deficiency record · 33
Documentation
Issued 10 April 2001
Resolved
SOLAS I/11_x001C_ ALL CERTIFICATES EXPIRED DUE TO SUSPENSION OF CLASS SOCIETY.
Construction/Loadline
Issued 10 April 2001
Resolved
ILLC 66 I/2_x001C_ ADDRESS OUTSTANDING CONDITIONS OF CLASS DUE 02FEB01._x001C_ WASTAGE STB W/O ENGINEROOM / SIDE SHELL PLATE BETWEEN FR. 24-108 GROOVED / CARGO HATCHES TO BE THICKNESS GAUGED.
Fire Fighting
Issued 10 April 2001
Resolved
VEHICLES STOWED IN CARGO SPACES WERE NOT DRAINED OF FUEL AND HAD THE BATTERIES CONNECTED. THE CARGO HOLD WAS NOT EQUIPPED WITH A FIXED FIRE FIGHTING SYSTEM.
Documentation
Issued 10 April 2001
Resolved
SOLAS I/12,14_x001C_ SAFETY EQUIPMENT CERTIFICATE WAS EXPIRED UPON ENTERING PORT.
Construction/Loadline
Issued 29 June 2000
Resolved
PROVIDE CLASS REPORT OF GAUGING WHERE THERE IS EXCESSIVE WASTEAGE IN THE HULL.
Fire Fighting
Issued 29 June 2000
Resolved
BOLTS ARE MISSING FOR THE ITERNATIONAL SHORE CONNECTION.
Construction/Loadline
Issued 29 June 2000
Resolved
EXCESSIVE OIL IN THE BILGES.
Fire Fighting
Issued 29 June 2000
Resolved
NOZZEL IS MISSING FROM THE FIRE HOSE IN THE ENGINE ROOM.
Unknown
Issued 29 June 2000
Resolved
ESTIMATED 50 OIL DRUMS ARE STORED ON DECK AND BLOCKING THE STARBOARD WALKWAY TO THE BOW.
Lifesaving
Issued 29 June 2000
Resolved
EXCESSIVE WASTAGE ON THE CRANE DECK AMIDSHIPS STARBOARD SIDE.
Fire Fighting
Issued 29 June 2000
Resolved
FIRE DRILLS WERE UNSAT.
Lifesaving
Issued 29 June 2000
Resolved
ABANDON SHIP DRILL WAS UNSAT.
Fire Fighting
Issued 29 June 2000
Resolved
ILO 147_x001C_ EXHAUST LEAKS IN THE EMERGENCY FIRE PUMP.
Lifesaving
Issued 29 June 2000
Resolved
MISSING LIGHTS AND LIGHT COVERS IN THE FOREPEAK.
Navigation
Issued 3 June 1999
Resolved
VESSEL FAILED TO HAVE ONBOARD A US COAST PILOT VOLUME 2. CORRECT PRIOR TO DEPARTING PORT OF ALBANY.
Electrical
Issued 3 June 1999
Resolved
REPAIR FUEL OIL LEAK FROM MANIFOLD ON STARBOARD GENERATOR PRIOR TO 10JUN99
Navigation
Issued 3 June 1999
Resolved
CHARTS OUTDATED AND NOT CORRECTED. MUST BE CORRECTED PRIOR TO DEPARTING PORT OF ALBANY.
Navigation
Issued 3 June 1999
Resolved
MANUEVERING FACT SHEET WITH WARNING LABEL MISSING. MUST BE CORRECTED PRIOR TO DEPARTING PORT OF ALBANY.
Electrical
Issued 3 June 1999
Resolved
INSTALL PROTECTIVE COVERS FOR VARIOUS LIGHTING THROUGHOUT VESSEL. MANY ARE MISSING AND SOME HAVE BROKEN BULBS WITH EXPOSED WIRES. INSTALL PRIOR TO 10JUN99.
Construction/Loadline
Issued 3 June 1999
Resolved
SEAL 1/4 INCH HOLES IN BULKHEAD BETWEEN ENGINE ROOM AND STEERING GEAR ROOM WHERE WIRES WERE REMOVED PRIOR TO 10JUN99.
Electrical
Issued 3 June 1999
Resolved
PROPERLY BRACE BATTERIES IN BATTERY ROOM ON BRIDGE WING PRIOR TO 10JUN99.
Lifesaving
Issued 3 June 1999
Resolved
MAKE REPAIRS TO FIBERGLASS DAMAGE TO STARBOARD LIFEBOAT WHERE DENTED AND WORN DOWN BY SUPPORT BLOCKS PRIOR TO 10JUN99.
Documentation
Issued 3 June 1999
Resolved
PROVIDE SAFE MANNING CERTIFICATE PRIOR TO DEPARTURE FROM PORT OF ALBANY
Construction/Loadline
Issued 3 June 1999
Resolved
REMOVE OILY WATER FROM ENGINE ROOM BILGE PRIOR TO DEPARTURE FROM PORT OF ALBANY.
Documentation
Issued 3 June 1999
Resolved
REWRITE DRAFT OIL TRANSFER PROCEDURES AND POST PER 33CFR155 SUBPART C PRIORTO DEPARTURE FROM THE PORT OF ALBANY.
Unknown
Issued 3 June 1999
Resolved
REMOVE PAINT FROM AFT STOREROOM AND PLACE IN APPROVED PAINT LOCKER PRIOR TODEPARTURE FROM PORT OF ALBANY.
Documentation
Issued 3 June 1999
Resolved
POST POLLUTION PLACARD IAW 33CFR155.450 PRIOR TO 10JUN99.
Lifesaving
Issued 3 June 1999
Resolved
REPAIR BRACKETS FOR PORT LIFEBOAT GRAB RAILS ON HULL WHERE BROKEN (2ND AFT ON EACH SIDE) PRIOR TO 10JUN99.
Lifesaving
Issued 3 June 1999
Resolved
PROVIDE ACCEPTANCE OF THE STORAGE OF THE REGRIGERATOR AND TWO FREEZERS IN THE PASSAGEWAY OUTSIDE THE GALLEY BY THE ADMINISTRATION PRIOR TO 10JUN99.
Lifesaving
Issued 3 June 1999
Resolved
REPAIR OR REPLACE THE GANGWAY TO VESSEL AS IT POSES A SAFTEY HAZARD TO THE CREW. REPAIR/REPLACE PRIOR TO 10JUN99.
Fire Fighting
Issued 3 June 1999
Resolved
ENSURE ITEMS LISTED ON FIRE CONTROL PLAN ARE ACCURATE AND CREW IS FAMILIAR WITH PLAN AND EQUIPMENT PRIOR TO 10JUN99. I.E. INTERNATIONAL SHORE CONNECTION IS ONBOARD BUT NOT IN DESIGNATED LOCATIONS.
Navigation
Issued 3 June 1999
Resolved
VESSEL MISSING USCG LIGHT LIST VOLUME 1. CORRECT PRIOR TO DEPARTURE.
Fire Fighting
Issued 3 June 1999
Resolved
MAKE REPAIRS TO MAIN AND EMERGENCY FIRE PUMPS TO INCREASE PRESSURE AT FAR END PRIOR TO 10JUN99. OUTPUT AT PUMPS ADEQUATE, HOWEVER HOSE AFT WAS LOW WITH HOSE OPENED FOWARD DURING DRILL.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.