Records from 1985 to 2016. Most recent: inspection, 19 February 2016.
Inspection history · 62
19 February 2016
Deficiency Check
Physical examination · Activities Europe · Activity 5818022
23 June 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2400065
8 July 2003
Drydock Extension · Administrative Inspection
Administrative · Activities Europe · Activity 1812900
7 October 2002
Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 1671160
17 October 2001
Deficiency Check
Physical examination · Activities Europe · Activity 1072700
5 July 2001
Re-Inspection
Physical examination · Activities Europe · Activity 1444585
25 October 2000
Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439122
1 August 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053514
26 July 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465581
11 July 2000
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1051342
9 November 1999
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 803986
16 October 1998
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 801971
8 June 1998
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1406334
28 October 1997
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 783439
28 October 1996
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 853110
26 September 1996
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411355
11 January 1996
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1189194
24 August 1995
Excursion Permit
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 884394
16 August 1995
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 131162
14 August 1995
Initial Construction-Excluding Oversight
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 875259
9 February 1995
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 204359
9 February 1995
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 752274
4 January 1995
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 708627
22 December 1994
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 169136
1 December 1994
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1158534
2 November 1994
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1398165
9 September 1994
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 39565
17 December 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 450616
29 November 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 651267
4 November 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 103558
7 October 1993
Deadweight Survey · Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1387413
18 August 1993
Excursion Permit
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1154637
2 August 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 651263
30 July 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 32069
7 July 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 651265
28 June 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 115048
3 January 1993
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 86524
2 December 1992
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1141543
6 November 1992
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 482136
2 November 1992
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1142981
31 March 1992
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 955205
31 January 1992
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1011713
5 December 1991
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1005890
21 November 1991
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1246990
9 October 1991
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1245823
3 October 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 940032
19 September 1991
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 938838
30 July 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 932919
2 November 1990
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 930226
16 February 1990
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 921982
7 August 1989
Excursion Permit
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 896259
17 November 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1204275
2 November 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1201474
24 June 1988
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1204048
13 July 1987
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1323220
5 December 1986
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1023515
13 October 1986
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1018557
28 August 1986
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1002768
14 July 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 984902
15 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288197
18 March 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1287943
11 February 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288538
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 8 October 2002
Resolved
8 Person room on main deck, crews quarters, must comply with 46 CFR 92.20-20 - Not more than 4 persons per room, 1 locker per person, seperate quarters for deck and engine personnel. Vessel appears to have been constructed and certificated contrary to regulations. LEGACY COMPONENT DESC: People Per Room
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 8 October 2002
Resolved
Provide proper toilet facilities for personnel, and crew berthed on main deck level. Vessel to comply with 46 CFR 92.20-25 - 1 Toilet per each 8 persons, and that is conveinently located to sleeping quarters. This vessel has twelve persons berthed on main deck level, and toilet facility. LEGACY COMPONENT DESC: Toilet
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Operations/Management › Drug and Alcohol Testing › Collection Sites
Issued 8 October 2002
Resolved
Vessel / Company to comply Alcohol & Chemical Drug testing IAW 46 CFR Part 16. Currently no proof testing or proof of a random testing is being done. LEGACY COMPONENT DESC: Testing, Random
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 8 October 2002
Resolved
Provide test procedures & verification that the installed fixed Halon system in the engine room, and bow thruster room has been tested, maintained, and operates properly. Annual servicing does not show that a function test for releasing agent can or has been done. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Means of Escape › Corridors
Issued 8 October 2002
Resolved
Repair / Adjust assist spring on engine room emergency escape scuttle on starboard side. This is a water tight 36" X 18" steel hatch. LEGACY COMPONENT DESC: Doorways
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Construction/Loadline › Penetrations › Weld
Issued 8 October 2002
Resolved
Renew open cell foam gaskets with hard rubber marine type gasket on main deck engine room air intake water tight closures. LEGACY COMPONENT DESC: Gasket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Construction/Loadline › Penetrations › Gasket
Issued 8 October 2002
Resolved
Provide port light cover for captains quarters and officer's lounge.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 8 October 2002
Resolved
Provide proper mounting bracket for stations #7 & #8. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving
Issued 5 July 2001
Resolved
PROVIDE USCG APPROVAL CERTIFICATE FOR NARWHAL SV-400 RESCUE BOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Engineering
Issued 5 July 2001
Resolved
PROVIDE APPROVED COPY OF AUTOMATION TEST PROCEDURES FOR VESSEL OR SUBMIT PROCEDURES ONBOARD VESSEL THAT HAVE BEEN REVIEWED BY USCG. MAKE NOTED CHANGES TO ONBOARD PROCEDURES AND OCMI WILL STAMP APPROVED FOR PLACEMENT ONBOARD VESSEL._x001C_
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Fire Fighting
Issued 5 July 2001
Resolved
PROVIDE TO [name withheld] A WRITTEN PROPOSAL TO SERVICE/RENEW VARIOUS COMPONENTS ON INSTALLED SHIP HALON FIXED SYSTEM USING ONLY APPROVED PLANS/LETTERS FROM SYSTEM MANUFACTURER, IE. FENWAL HALON 1301. PROVIDE MANUFACTURES SERVICE MANUAL FOR SYSTEM AND MAINTAIN ONBOARD VSL AT ALL TIME
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Lifesaving
Issued 5 July 2001
Resolved
INSTALL GENERAL ALARM BELLS TO PROVIDE COVERAGE THROUGHOUT ENTIRE VESSEL; NOTED AREAS W/O BELLS ARE BOTH MAIN DECK AND O1 DECK, AREA IMMEDIATELY AFT OF HOUSE._x001C_ _x001C_
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Lifesaving
Issued 5 July 2001
Resolved
INSTALL APPROX. 1 METER X 1 METER PLATFORM AT RESCUE BOAT DAVIT FOR USE DURING LAUNCHING / RETRIEVING RESCUE BOAT. CURRENT ARRANGEMENT/ PROCEDURE ENDANGERS PERSONS TO FALLING OVERBOARD DURING THIS EVOLUTION._x001C_ _x001C_
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Accommodation/Occupational Safety
Issued 5 July 2001
Resolved
REPAIR TOILER MAIN DECK FWD HEAD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Fire Fighting
Issued 5 July 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Deck/Cargo
Issued 5 July 2001
Resolved
HYDROSTATICALLY TEST CARGO HOSES TO 1.5 X MAWP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Fire Fighting
Issued 5 July 2001
Resolved
PROVIDE METALLIC MECHANICAL CLOSURES TO PORT AND STBD EXHAUST VENTILATION DUCTS IN THE STACK LOCKERS.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Construction/Loadline
Issued 5 July 2001
Resolved
PROVIDE COVER PLATE FOR PORT HOLE IN MAIN DECK AFT GALLEY DOOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Navigation
Issued 5 July 2001
Resolved
PROVIDE COPY OF CERTIFICATE OF ALTERNATIVE COMPLIANCE FOR NAVIGATION LIGHT DEVIATION FROM RULES, FWD AND AFT MASTHEAD SEPARATION AND SIDELIGHT PLACEMENT_x001C_
Condition: Unknown
Due 6 August 2001
Resolved 8 October 2002
Documentation
Issued 5 July 2001
Resolved
UPDATE FIRE CONTROL PLAN TO REFLECT CHANGES IN SCBA LOCATION AND TO INCLUDETWO GENERAL ALARM BELLS PER #8._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Electrical
Issued 26 July 2000
Resolved
INSTALL AND TEST REVERSE POWER RELAYS TO SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 July 2000
Resolved 26 July 2000
Fire Fighting
Issued 26 July 2000
Resolved
CONDUCT SATISFACTORY INSPECTION OF VESSEL'S FIXED HALON SYSTEM TO SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 August 2000
Resolved 1 August 2000
Documentation
Issued 26 July 2000
Resolved
PROVIDE FOR APPROVAL AUTOMATION TEST PROCEDURES.
Condition: Unknown
Due 26 July 2000
Resolved 26 July 2000
Lifesaving
Issued 11 January 1996
Resolved
REPLACE OR REPAIR 3 PFD'S REJECTED BY INSPECTOR FOR FOLLOWING REASONS: 1 PFD MISSING WHISTLE, 1 MISSING RETROREFLECTIVE TAPE AND 1 REJECTED DUE TO EXCESSIVE WEAR.
Condition: Unknown
Due 11 January 1996
Resolved 1 February 1996
Lifesaving
Issued 11 January 1996
Resolved
ONE EXPOSURE SUIT REJECTED DUE TO MISSING HIGH RIDER COLLAR.
Condition: Unknown
Due 11 January 1996
Resolved 1 February 1996
Engineering
Issued 11 January 1996
Resolved
REPLACE AND PROVE PROPER OPERATION OF STBD REDUCTION GEAR OIL HIGH TEMPERATURE ALARM.
Condition: Unknown
Due 11 January 1996
Resolved 1 February 1996
Lifesaving
Issued 2 November 1994
Resolved
CONDUCT WEIGHT TEST OF DAVIT FOR RESCUE BOAT TO 110% OF TOTAL WEIGHT OF BOAT & PERSONS.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Electrical
Issued 2 November 1994
Resolved
PROVIDE AND INSTALL MANUFACTURER APPROVED GUARD FOR LIGHT FIXTURE IN MACHINERY CONEX ON MAIN DECK.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Lifesaving
Issued 2 November 1992
Resolved
REPLACE ALL "D" CELL BATTERIES IN WATERLIGHTS FOR PFDS/EXPOSURE SUITS WITH DATE STAMPED BATTERIES; ALSO PROPERLY MOUNT ALL WATER LIGHTS ON PFD'S AND EXPOSURE SUITS TO SHOLDER AREA.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Fire Fighting
Issued 2 November 1992
Resolved
REMOVE ELECTRICAL WIRE WHICH RUNS THROUGH A VENT CLOSURE TO THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Navigation
Issued 2 November 1992
Resolved
REPAIR RINGER ON PHONE IN STEERING ROOM.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Fire Fighting
Issued 2 November 1992
Resolved
HAVE SEMI-PORTABLE CO2 FIRE EXTINGUISHER LOCATED IN ENGINEROOM SERVICED.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Electrical
Issued 2 November 1992
Resolved
REMOVE OR END IN JUNCTION BOX DEAD ENDED WIRE IN OVERHEAD OF GYRO ROOM.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Electrical
Issued 2 November 1992
Resolved
INSTALL BLANK OR A CIRCUIT BREAKER IN NUMBER 8 SLOT OF ELECTRICAL PANEL PI.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Electrical
Issued 2 November 1992
Resolved
REPAIR POWER DISCONNECT SWITCH FOR CHILL ROOM EVAPORATOR LOCATED ON STBD BULKHEAD IN GALLEY PASSAGEWAY.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Accommodation/Occupational Safety
Issued 2 November 1992
Resolved
REMOVE HOSE OR INSTALL HANGING RACK FOR HOSE IN SHOWER PORT SIDE FORWARD OFGALLEY.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Fire Fighting
Issued 2 November 1992
Resolved
PROVIDE AND INSTALL FLAME SCREEN AND CLOSURE FOR VENT TO PAINT LOCKER.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Accommodation/Occupational Safety
Issued 2 November 1992
Resolved
PROPERLY LABEL ALL EMERGENCY ESCAPES ON DECK FOR ENGINE ROOM.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Fire Fighting
Issued 2 November 1992
Resolved
PROVIDE OR REPAIR KEEPER CHAINS FOR FOG TIP TO FIRE HOSE NOZZLES AT STATIONS 2,3, AND 4.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Electrical
Issued 2 November 1992
Resolved
PROPERLY MOUNT ALL OVERHEAD VERTICLE RUNS OF ELECTRICAL WIRING WITH METAL BANDS LOCATED ON MAIN DECK AFT IN AREA OF CONEX BOXES.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Accommodation/Occupational Safety
Issued 2 November 1992
Resolved
REMOVE PERMANENTLY INSTALLED AIR LINE ON SANITARY SYSTEM TANK AND REPLACE WITH A QUICK DISCONNECT AIR LINE.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Navigation
Issued 2 November 1992
Resolved
PROPERLY INSTALL WIRING FOR PORT WINDSHIELD WIPER LOCATED UNDER FORWARD WHEEL HOUSE CONTROLS.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Lifesaving
Issued 2 November 1992
Resolved
PROPERLY ATTACH ALL WATER LIGHTS AND LINES FOR RING BUOYS.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Electrical
Issued 2 November 1992
Resolved
REPAIR ELECTRICAL WIRING LOCATED ON FOCSLE DECK ON BULKHEAD AFT OF ANCHOR WINDLASS.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Electrical
Issued 2 November 1992
Resolved
INSTALL MISSING FUSE AND COVER FOR NAVIGATION LIGHT ALARM PANEL.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Documentation
Issued 21 November 1991
Resolved
VESSEL HAS NO AUTOMATION TEST PROCEDURES ON BOARD.
Condition: Unknown
Due 15 December 1991
Resolved 12 February 1992
Deck/Cargo
Issued 30 July 1991
Resolved
CRANE IS NOT TO BE OPERATED UNTIL MSO PUGET SOUND IS PROVIDED APPROVED COPIES OF CRANE INSTALLATION DRAWINGS.
Condition: Unknown
Due 30 July 1991
Resolved 30 July 1991
Documentation
Issued 30 July 1991
Resolved
VESSEL IS TO PROVIDE [name withheld] WITH A REVISED COPY OF A STABILITY LETTER PRIOR TO 30 SEP 1991 OR CEASE ALL OPERATIONS UNTIL SUCH TIME AS STABILITY LETTER IS PROVIDED. VESSEL MAY TRANSIT FROM SEATTLE TO PRINCE WILLIAM SOUND. ALL OPERATIONS RESTRICTED TO PRINCE WILLIAM SOUND.
Condition: Unknown
Due 30 July 1991
Resolved 30 July 1991
Fire Fighting
Issued 2 November 1990
Resolved
MAKE FIRE HOSES AND HYDRANTS COMPATABLE.
Condition: Unknown
Due 2 November 1990
Resolved 2 November 1990
Engineering
Issued 2 November 1990
Resolved
HYDRO P/V AS REQUIRED
Condition: Unknown
Due 2 November 1990
Resolved 2 November 1990
Construction/Loadline
Issued 2 November 1990
Resolved
MAKE W/T DOORS OPERATE PROPERLY
Condition: Unknown
Due 2 November 1990
Resolved 2 November 1990
Fire Fighting
Issued 2 November 1990
Resolved
PAINT LOCKER CO2 SYSTEM NOT OPERATIONAL
Condition: Unknown
Due 2 November 1990
Resolved 2 November 1990
Lifesaving
Issued 16 February 1990
Resolved
RENEW WATER LIGHTS ON ALL EXPOSURE SUITS.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Construction/Loadline
Issued 16 February 1990
Resolved
ER. ESCAPE HATCHS INOPERABLE.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Accommodation/Occupational Safety
Issued 16 February 1990
Resolved
MSD INOPERABLE RENEW OR REPAIR.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Lifesaving
Issued 16 February 1990
Resolved
LINE THROWING APPURATUS MISSING.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Lifesaving
Issued 16 February 1990
Resolved
WEAK LINKS MISSING ON RAFTS
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Navigation
Issued 17 November 1988
Resolved
REPAIR AND PROVE PROPER OPERATION OF STARBOARD STEERING MOTOR POWER FAILUREALARM.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Lifesaving
Issued 17 November 1988
Resolved
PROVE PROPER OPERATION OF ENGINE STOP BUTTON FOR RESCUE BOAT OUTBOARD.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Documentation
Issued 17 November 1988
Resolved
PROVIDE VESSEL WITH CURRENT CERTIFICATE OF DOCUMENTATION PRIOR TO VESSEL OPERATION.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Accommodation/Occupational Safety
Issued 17 November 1988
Resolved
TIGHTEN EXISTING MOUNTING BOLTS AND PROVIDE MISSING MOUNTING BOLTS ON SEWAGE TREATMENT PLANT AND MAIN ENGINE START AIR RECEIVERS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988
Resolved
LABEL EMERGENCY FUEL SHUT-OFFS ON MAIN DECK (PORT & STBD).
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988
Resolved
REPAIR/REPLACE BILGE PUMP SUCTION GAGE.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Electrical
Issued 17 November 1988
Resolved
REPAIR LIGHTING ABOVE MAIN SWITCHBOARD.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Accommodation/Occupational Safety
Issued 17 November 1988
Resolved
REPLACE TEMPERATURE/PRESSURE RELIEF VALVE ON HOT WATER HEATER WITH 100 PSI VALVE.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Fire Fighting
Issued 17 November 1988
Resolved
CONDUCT A FIRE AND BOAT DRILL IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988
Resolved
REPAIR AND PROVE PROPER OPERATION OF INOPERATIVE BRIDGE CONSOLE TELLTALE LIGHTS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Navigation
Issued 17 November 1988
Resolved
UPDATE ALL NAVIGATION CHARTS AND PUBLICATIONS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Fire Fighting
Issued 17 November 1988
Resolved
REPLACE FIREMAIN PRESSURE GAGE GLASS IN ENGINE CONTROL ROOM.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988
Resolved
SECURE LUBE OIL PIPING IN FORWARD ENGINE ROOM.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Electrical
Issued 17 November 1988
Resolved
REMOVE DEAD-END WIRING TO CHLORINATOR PUMP.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988
Resolved
RRPAIR AND PROVE PROPER OPERATION OF ENGINE ROOM ALARM SYSTEMS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988
Resolved
PROVIDE/INSTALL BILGE PUMP DISCHARGE PRESSURE GAGE.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Fire Fighting
Issued 13 October 1986
Resolved
REPAIR/REPLACE TIME DELAY RELAYS FOR FIXED HALON 1301 ENGINE ROOM AND BOW THRUSTER FIXED FIRE EXTINGISHING SYSTEM TO AGREE WITH SYSTEMS AS ORGINALLY APPROVED AND INSTALLED.
Condition: Unknown
Due 13 October 1986
Resolved 13 October 1986
Lifesaving
Issued 28 August 1986
Resolved
PROVIDE ONE (1) HYDRO STATIC RELEASE THAT IS CURRENTLY SERVICED FOR EACH INFLATTABLT LIFE RAFT INSTALLATION.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Fire Fighting
Issued 28 August 1986
Resolved
REINSTALL HALON 1301 BOTTLE IN ENG RM IMMEDIATELY UPON RETURN TO VESSEL FROM SERVICING FACILITY BUT NO LATER THAN 1 SEP 86 AND PROVIDE COPY OF SERVICING REPORT TO USCG MSD KENAI.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Navigation
Issued 28 August 1986
Resolved
PROVIDE SUITABLE BELL TO COMPLY WITH NAVIGATION RULES.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Deck/Cargo
Issued 28 August 1986
Resolved
HAVE THE FUEL OIL TRANSFER HOSE HYDROSTATICALLY TESTED AND MARKED WITH TESTDATES AND PRESSURES.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Fire Fighting
Issued 28 August 1986
Resolved
PROVIDE FOR A FIRE AND ABONDON SHIP DRILL IN THE PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Lifesaving
Issued 28 August 1986
Resolved
PROVIDE 1 ADDITIONAL ADULT PFD (TYPE I) MARKED WITH VESSEL'S NAME AND EQUIPPED WITH PFD LIGHT & WHISTLE. TOTAL PERSONS ALLOWED ON BOARD IS REDUCED TO 23 UNTIL SUCH TIME AS IT IS ON BOARD.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Electrical
Issued 28 August 1986
Resolved
PROVIDE COVER ON JUNCTION BOX IN WALK IN FREEZER.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Electrical
Issued 28 August 1986
Resolved
PROVIDE GLOBES TO LIGHT FIXTURES THAT ARE MISSING THE SAME IN PANTRY AND BETWEEN THE S/S GENERATOR SETS.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Unknown
Issued 28 August 1986
Resolved
REPAIR/REPLACE AIR REGULATOR AT REDUCING STATION FOR BOW THRUSTER AIR RECEIVER AND PROVIDE FOR RELIEF VALVE SETTING IN THE PRESENCE OF A CG INSPECTOR.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986
Construction/Loadline
Issued 28 August 1986
Resolved
PERMANTLY CLOSE BULKHEAD WIRE PENETRATION JUST ABOVE DECK HOUSE ENTRANCE TO MAIN DECK.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986